1.
Chemphyschem ; 24(21): e202300438, 2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37665230

RESUMEN

We defined four major deterioration factors (electrolyte loss (EL), lithium loss (LL), lithium precipitation (LP), and compound deterioration (CD)). Then, we derived eleven key performance indicators (KPIs) for comparative analysis. After that, we fabricated three deteriorated cells for each of three deterioration factors (EL, LL, and LP) and one cell with CD (for verification) with four individual (dis)charging experiment manuals. The two major contributions of this study are the performance of 1) trend analysis to determine a suitable diagnostic metric by inspecting the eleven KPIs and 2) comparison analysis of V o c v , t ' ' ${{V}_{ocv,t}^{{ {^\prime} {^\prime}}}}$ and V o c v , t , s i m ' ' ${{V}_{ocv,t,sim}^{{ {^\prime} {^\prime}}}}$ to verify the effectiveness of utilizing V o c v , t ' ' ${{V}_{ocv,t}^{{ {^\prime} {^\prime}}}}$ as a real-time deterioration diagnostic factor using a concept of model-in-the-loop simulation. The results show that 1) V o c v , t ' ' ${{V}_{ocv,t}^{{ {^\prime} {^\prime}}}}$ has the most conspicuous trendline tendency among the eleven comparison targets for all four major deterioration factors, and 2) the angle difference between the two trends of V o c v , t ' ' ${{V}_{ocv,t}^{{ {^\prime} {^\prime}}}}$ and V o c v , t , s i m ' ' ${{V}_{ocv,t,sim}^{{ {^\prime} {^\prime}}}}$ lies within a minimum of 9° and a maximum of 43° (with a 10 4 ${{10}^{4}}$ sscale on the x-axis and a 10 - 7 ${{10}^{-7}}$ scale on the y-axis for a clear trend line analysis). From this, we can conclude that the trendline-based real-time deterioration analysis employing V o c v , t ' ' ${{V}_{ocv,t}^{{ {^\prime} {^\prime}}}}$ may be practically applicable to a limited extent.

2.
Small ; 19(22): e2207966, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36861366

RESUMEN

Herein, a novel combination of Mg- and Ga-co-doped ZnO (MGZO)/Li-doped graphene oxide (LGO) transparent electrode (TE)/electron-transporting layer (ETL) has been applied for the first time in Cu2 ZnSn(S,Se)4 (CZTSSe) thin-film solar cells (TFSCs). MGZO has a wide optical spectrum with high transmittance compared to that with conventional Al-doped ZnO (AZO), enabling additional photon harvesting, and has a low electrical resistance that increases electron collection rate. These excellent optoelectronic properties significantly improved the short-circuit current density and fill factor of the TFSCs. Additionally, the solution-processable alternative LGO ETL prevented plasma-induced damage to chemical bath deposited cadmium sulfide (CdS) buffer, thereby enabling the maintenance of high-quality junctions using a thin CdS buffer layer (≈30 nm). Interfacial engineering with LGO improved the Voc of the CZTSSe TFSCs from 466 to 502 mV. Furthermore, the tunable work function obtained through Li doping generated a more favorable band offset in CdS/LGO/MGZO interfaces, thereby, improving the electron collection. The MGZO/LGO TE/ETL combination achieved a power conversion efficiency of 10.67%, which is considerably higher than that of conventional AZO/intrinsic ZnO (8.33%).

3.
ACS Appl Mater Interfaces ; 9(50): 44161-44172, 2017 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-29182242

RESUMEN

The roles of a partially fluorinated ether (PFE) based on a mixture of 1,1,1,2,2,3,3,4,4-nonafluoro-4-methoxybutane and 2-(difluoro(methoxy)methyl)-1,1,1,2,3,3,3-heptafluoropropane on the oxidative durability of an electrolyte under high-voltage conditions, the rate capability of the graphite and 5 V-class LiNi0.4Mn1.6O4 (LNMO) electrodes, and the cycling performance of graphite/LNMO full cells are examined. Our findings indicate that the use of PFE as a cosolvent in the electrolyte yields thermally stable electrolytes with self-extinguishing ability. Electrochemical tests confirm that the PFE combined with fluoroethylene carbonate (FEC) effectively alleviates the oxidative decomposition of the electrolyte at the high-voltage LNMO cathode and enables reversible electrochemical reactions of the graphite anodes and LNMO cathodes at high rates. Moreover, the combination of PFE, which mitigates electrolyte decomposition at high voltages, and FEC, which stabilizes the anode-electrolyte interface, enables the reversible cycling of high-voltage full cells (graphite/LNMO) with a capacity retention of 70.3% and a high Coulombic efficiency of 99.7% after 100 cycles at 1C rate at 30 °C.

4.
Biosens Bioelectron ; 26(7): 3266-71, 2011 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-21255993

RESUMEN

The interface resistances between an anion exchange membrane (AEM) and the solution electrolyte were measured for low buffer (or ionic strength) of electrolytes typical of microbial fuel cells (MFCs). Three AEMs (AFN, AM-1, and ACS) having different properties were tested in a flat-plate MFC to which 5-mM acetate was fed to the anode and an air-saturated phosphate buffer (PB) solution was fed to the cathode. Current density achieved in the MFCs was correlated inversely with independently measured membrane-only resistances. However, the total interfacial resistances measured by current-voltage plots were approximately two orders higher than those of the membrane-only resistances, although membranes had the same order as with the membrane-only resistance. EIS spectra showed that the resistances from electric-double layer and diffusion boundary layer were the main resistances not the membrane's resistance. The electric-double layer and diffusion boundary layer resistances of the AEMs were much larger in the 10 mM PB electrolyte, compared to 100 mM PB. EIS study also showed that the resistance of diffusion boundary layer decreased due to mechanical stirring. Therefore, the interface resistance that originates from the interaction between the membrane and the catholyte solution should be considered when designing and operating MFC processes with an AEM. The AEMs allowed transport of uncharged O(2) and acetate, but the current losses for both were low during normal MFC operation.


Asunto(s)
Aniones/química , Fuentes de Energía Bioeléctrica , Membranas Artificiales , Acetatos/química , Espectroscopía Dieléctrica , Intercambio Iónico , Concentración Osmolar , Oxígeno/química
5.
Phys Chem Chem Phys ; 12(46): 15291-300, 2010 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-20953477

RESUMEN

Interfacial resistances between the polymer electrolyte membrane (PEM) and catalyst layer (CL) in membrane-electrode assemblies (MEAs) have yet to be systematically examined in spite of its great importance on the fuel cell performance. In order to investigate ionic transport through the PEM/CL interface, the symmetrical impedance mode (SIM) was employed in which the same type of gas was injected (H(2)/H(2)). In this study, the ionic transport resistance at the interface was controlled by the additionally sprayed outer ionomer on the surface of each CL. Effectiveness of the outer ionomer on ionic transport at the interface was quantitatively explained by the reduced contact, proton hydration, and charge transport resistances in the SIM. To characterize the ionic transport resistance, the concept of total resistance (R(tot)) in the SIM was introduced, representing the overall ohmic loss due to proton transport in an MEA. This concept was successfully supported via an agreement of the interpretation and the linear correlation that was obtained between the admittance (1/R(tot)) and the performance of a fuel cell in the ohmic loss region. This correlation will enable researchers to predict the performance of a fuel cell under the influence of proton transport by examining the R(tot) in the SIM.

6.
J Phys Chem B ; 114(41): 13121-7, 2010 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-20873845

RESUMEN

For development of proton conductive membranes, it is a difficult dilemma to balance proton conductivity and methanol permeability; however, this research proposes a simple strategy to solve this problem, i.e., embedding a proton conductive "barrier" into the perflorosulfonated matrix. The strategy is exemplified by embedding the amphoteric sulfonated poly(phthalazinone ether sulfone kentone) (SPPESK) into a semicrystalline perflorosulfonic acid polymer matrix (FSP). After being annealed, the domain of SPPESK is converted to the barrier. Two acid-base interactions constitute the barrier for both the transfer of protons and the blockage of methanol, respectively. On one hand, poorly hydrophilic ionic acid-base interactions (-SO(3)(-)...NH(+)-) are formed between sulfonic acid group and phthalazinone group through annealing and are useful for methanol blocking. On the other hand, more hydrophilic hydrogen-bonded acid-base interaction (-SO(3)H...(H(2)O)(n)...N-, n ≤ 3) can also be formed under hydrated condition and facilitate proton transport according to the Grotthuss-type mechanism. As a result, the final membrane exhibits an extremely low methanol permeability (30% of that of Nafion-112) and an excellent fuel cell performance (as compared with Nafion-112 at 80 °C).

7.
J Phys Chem B ; 113(36): 12265-70, 2009 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-19685918

RESUMEN

Different from H(3)O(+) transport as in the vehicle mechanism, protons find another channel to transfer through the poorly hydrophilic interlayers in a hydrated multiphase membrane. This membrane was prepared from poly(phthalazinone ether sulfone kentone) (SPPESK) and H(+)-form perfluorosulfonic resin (FSP), and poorly hydrophilic electrostatically interacted acid-base pairs constitute the interlayer between two hydrophilic phases (FSP and SPPESK). By hydrogen bonds forming and breaking between acid-base pairs and water molecules, protons transport directly through these poorly hydrophilic zones. The multiphase membrane, due to this unique transfer mechanism, exhibits better electrochemical performances during fuel cell tests than those of pure FSP and Nafion-112 membranes: 0.09-0.12 S cm(-1) of proton conductivity at 25 degrees C and 990 mW cm(-2) of the maximum power density at a current density of 2600 mA cm(-2) and a cell voltage of 0.38 V.

8.
Talanta ; 71(1): 129-35, 2007 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19071278

RESUMEN

A poly(vinyl alcohol) film cross-linked with glutaraldehyde (PVA-GA) was introduced to the surface of a tyrosinase-based carbon paste electrode. The coated PVA-GA film was beneficial in terms of increasing the stability and reproducibility of the enzyme electrode. The electrode showed a sensitive current response to the reduction of the o-quinone, which was the oxidation product of phenol, by the tyrosinase, in the presence of oxygen. The effects of the PVA and PVA-GA coating, the pH, and the GA:PVA ratio on the current response were investigated. The sensitivity of the PVA-GA-Tyr electrode was 130.56microA/mM (1.8microA/microM cm(2)) and the linear range of phenol was 0.5-100microM. At a higher concentration of phenol (>100microM), the current response showed the Michaelis-Menten behavior. Using the PVA-GA-Tyr electrode, a two-electrode system was tested as a prototype sensor for portable applications.

9.
J Colloid Interface Sci ; 300(2): 655-62, 2006 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-16730020

RESUMEN

This study aimed at investigating ion-exchange membrane systems using impedance spectroscopy. Nyquist plots showed that the impedance obtained in this study described the ion-exchange membrane system well, as consisting of (i) an ion-exchange membrane immersed in solution, (ii) electrical double layers at the membrane surface, and (iii) diffusion boundary layers arising from the interface between the ion-exchange membrane and the electrolyte solutions. Taking into account the physical and electrochemical understanding of the ion-exchange membrane system, an equivalent circuit was suggested to quantitatively analyze each component of the ion-exchange membrane system. To confirm the reliability of the proposed equivalent circuit, the resistance and capacitance were estimated from the impedance data and the values were compared with other experimental results (e.g., I-V curves). The comparison showed good agreement and validated the equivalent circuit. Moreover, the impedance measurements made it possible to confirm the electroconvective effects in the over LCD region.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA