Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1044822

RESUMEN

Abnormalities on breast ultrasound (US) images which do not meet the criteria for masses are referred to as nonmass lesions.These features and outcomes have been investigated in several studies conducted by Asian researchers. However, the term “nonmass” is not included in the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) 5th edition for US. According to the Japan Association of Breast and Thyroid Sonology guidelines, breast lesions are divided into mass and nonmass. US findings of nonmass abnormalities are classified into five subtypes: abnormalities of the ducts, hypoechoic areas in the mammary glands, architectural distortion, multiple small cysts, and echogenic foci without a hypoechoic area. These findings can be benign or malignant; however, focal or segmental distributions and presence of calcifications suggest malignancy. Intraductal, invasive ductal, and lobular carcinomas can present as nonmass abnormalities. For the nonmass concept to be included in the next BI-RADS and be widely accepted in clinical practice, standardized terminologies, an interpretation algorithm, and outcome-based evidence are required for both screening and diagnostic US.

2.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1044827

RESUMEN

Objective@#We aimed to evaluate the clinical and imaging factors associated with hemorrhagic complications and patient discomfort following ultrasound (US)-guided breast biopsy. @*Materials and Methods@#We prospectively enrolled 94 patients who were referred to our hospital between June 2022 and December 2022 for US-guided breast biopsy. After obtaining informed consent, two breast radiologists independently performed US-guided breast biopsy and evaluated the imaging findings. A hemorrhagic complication was defined as the presence of bleeding or hematoma on US. The patients rated symptoms of pain, febrile sensation, swelling at the biopsy site, and dyspnea immediately, 20 minutes, and 2 weeks after the procedure on a visual analog scale, with 0 for none and 10 for the most severe symptoms. Additional details recorded included those of nausea, vomiting, bleeding, bruising, and overall satisfaction score. We compared the clinical symptoms, imaging characteristics, and procedural features between patients with and those without hemorrhagic complications. @*Results@#Of 94 patients, 7 (7%) developed hemorrhagic complications, while 87 (93%) did not. The complication resolved with 20 minutes of manual compression, and no further intervention was required. Vascularity on Doppler examination (P = 0.008), needle type (P = 0.043), and lesion location (P < 0.001) were significantly different between the groups. Patients with hemorrhagic complications reported more frequent nausea or vomiting than those without hemorrhagic complications (29% [2/7] vs. 2% [2/87], respectively; P= 0.027). The overall satisfaction scores did not differ between the two groups (P= 0.396). After 2 weeks, all symptoms subsided, except bruising (50% 2/4 in the complication group and 25% [16/65] in the no-complication group). @*Conclusion@#US-guided breast biopsy is a safe procedure with a low complication rate. Radiologists should be aware of hemorrhagic complications, patient discomfort, and overall satisfaction related to this procedure.

3.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1044840

RESUMEN

Objective@#To investigate whether reader training improves the performance and agreement of radiologists in interpreting unenhanced breast magnetic resonance imaging (MRI) scans using diffusion-weighted imaging (DWI). @*Materials and Methods@#A study of 96 breasts (35 cancers, 24 benign, and 37 negative) in 48 asymptomatic women was performed between June 2019 and October 2020. High-resolution DWI with b-values of 0, 800, and 1200 sec/mm 2 was performed using a 3.0-T system. Sixteen breast radiologists independently reviewed the DWI, apparent diffusion coefficient maps, and T1-weighted MRI scans and recorded the Breast Imaging Reporting and Data System (BI-RADS) category for each breast. After a 2-h training session and a 5-month washout period, they re-evaluated the BI-RADS categories. A BI-RADS category of 4 (lesions with at least two suspicious criteria) or 5 (more than two suspicious criteria) was considered positive.The per-breast diagnostic performance of each reader was compared between the first and second reviews. Inter-reader agreement was evaluated using a multi-rater κ analysis and intraclass correlation coefficient (ICC). @*Results@#Before training, the mean sensitivity, specificity, and accuracy of the 16 readers were 70.7% (95% confidence interval [CI]: 59.4–79.9), 90.8% (95% CI: 85.6–94.2), and 83.5% (95% CI: 78.6–87.4), respectively. After training, significant improvements in specificity (95.2%; 95% CI: 90.8–97.5; P = 0.001) and accuracy (85.9%; 95% CI: 80.9–89.8; P = 0.01) were observed, but no difference in sensitivity (69.8%; 95% CI: 58.1–79.4; P = 0.58) was observed. Regarding inter-reader agreement, the κ values were 0.57 (95% CI: 0.52–0.63) before training and 0.68 (95% CI: 0.62–0.74) after training, with a difference of 0.11 (95% CI: 0.02–0.18; P = 0.01). The ICC was 0.73 (95% CI: 0.69–0.74) before training and 0.79 (95% CI: 0.76–0.80) after training (P = 0.002). @*Conclusion@#Brief reader training improved the performance and agreement of interpretations by breast radiologists using unenhanced MRI with DWI.

4.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1044869

RESUMEN

Objective@#To prospectively investigate the influence of the menstrual cycle on the background parenchymal signal (BPS) and apparent diffusion coefficient (ADC) of the breast on diffusion-weighted MRI (DW-MRI) in healthy premenopausal women. @*Materials and Methods@#Seven healthy premenopausal women (median age, 37 years; range, 33–49 years) with regular menstrual cycles participated in this study. DW-MRI was performed during each of the four phases of the menstrual cycle (four examinations in total). Three radiologists independently assessed the BPS visual grade on images with b-values of 800 sec/mm2 (b800), 1200 sec/mm2 (b1200), and a synthetic 1500 sec/mm2 (sb1500). Additionally, one radiologist conducted a quantitative analysis to measure the BPS volume (%) and ADC values of the BPS (ADCBPS) and fibroglandular tissue (ADCFGT). Changes in the visual grade, BPS volume (%), ADCBPS, and ADCFGT during the menstrual cycle were descriptively analyzed. @*Results@#The visual grade of BPS in seven women varied from mild to marked on b800 and from minimal to moderate on b1200 and sb1500. As the b-value increased, the visual grade of BPS decreased. On b800 and sb1500, two of the seven volunteers showed the highest visual grade in the early follicular phase (EFP). On b1200, three of the seven volunteers showed the highest visual grades in EFP. The BPS volume (%) on b800 and b1200 showed the highest value in three of the six volunteers with dense breasts in EFP. Three of the seven volunteers showed the lowest ADCBPS in the EFP. Four of the seven volunteers showed the highest ADCBPS in the early luteal phase (ELP) and the lowest ADCFGT in the late follicular phase (LFP). @*Conclusion@#Most volunteers did not exhibit specific BPS patterns during their menstrual cycles. However, the highest BPS and lowest ADCBPS were more frequently observed in EFP than in the other menstrual cycle phases, whereas the highest ADCBPS was more common in ELP. The lowest ADCFGT was more frequent in LFP.

5.
Journal of Breast Cancer ; : 292-301, 2023.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-1000782

RESUMEN

Purpose@#Detection of multifocal, multicentric, and contralateral breast cancers in patients affects surgical management. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can identify additional foci that were initially undetected by conventional imaging. However, its use is limited owing to low specificity and high false-positive rate. Multiparametric MRI (DCE-MRI + diffusion-weighted [DW] MRI) can increase the specificity. We aimed to describe the protocols of our prospective, multicenter, observational cohort studies designed to compare the diagnostic performance of DCE-MRI and multiparametric MRI for the diagnosis of multifocal, multicentric cancer and contralateral breast cancer in patients with newly diagnosed breast cancer. @*Methods@#Two studies comparing the performance of DCE-MRI and multiparametric MRI for the diagnosis of multifocal, multicentric cancer (NCT04656639) and contralateral breast cancer (NCT05307757) will be conducted. For trial NCT04656639, 580 females with invasive breast cancer candidates for breast conservation surgery whose DCE-MRI showed additional suspicious lesions (breast imaging reporting and data system [BI-RADS] category ≥ 4) on DCE-MRI in the ipsilateral breast will be enrolled. For trial NCT05307757, 1098 females with invasive breast cancer whose DCE-MRI showed contralateral lesions (BI-RADS category ≥ 3 or higher on DCE-MRI) will be enrolled. Participants will undergo 3.0-T DCE-MRI and DWMRI. The diagnostic performance of DCE-MRI and multiparametric MRI will be compared.The receiver operating characteristic curve, sensitivity, specificity, positive predictive value, and characteristics of the detected cancers will be analyzed. The primary outcome is the difference in the receiver operating characteristic curve between DCE-MRI and multiparametric MRI interpretation. Enrollment completion is expected in 2024, and study results are expected to be presented in 2026.Discussion: This prospective, multicenter study will compare the performance of DCE-MRI versus multiparametric MRI for the preoperative evaluation of multifocal, multicentric, and contralateral breast cancer and is currently in the patient enrollment phase.

6.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-968240

RESUMEN

Objective@#To compare the outcomes of digital breast tomosynthesis (DBT) screening combined with ultrasound (US) with those of digital mammography (DM) combined with US in women with dense breasts. @*Materials and Methods@#A retrospective database search identified consecutive asymptomatic women with dense breasts who underwent breast cancer screening with DBT or DM and whole-breast US simultaneously between June 2016 and July 2019. Women who underwent DBT + US (DBT cohort) and DM + US (DM cohort) were matched using 1:2 ratio according to mammographic density, age, menopausal status, hormone replacement therapy, and a family history of breast cancer. The cancer detection rate (CDR) per 1000 screening examinations, abnormal interpretation rate (AIR), sensitivity, and specificity were compared. @*Results@#A total of 863 women in the DBT cohort were matched with 1726 women in the DM cohort (median age, 53 years; interquartile range, 40–78 years) and 26 breast cancers (9 in the DBT cohort and 17 in the DM cohort) were identified. The DBT and DM cohorts showed comparable CDR (10.4 [9 of 863; 95% confidence interval {CI}: 4.8–19.7] vs. 9.8 [17 of 1726;95% CI: 5.7–15.7] per 1000 examinations, respectively; P = 0.889). DBT cohort showed a higher AIR than the DM cohort (31.6% [273 of 863; 95% CI: 28.5%–34.9%] vs. 22.4% [387 of 1726; 95% CI: 20.5%–24.5%]; P < 0.001). The sensitivity for both cohorts was 100%. In women with negative findings on DBT or DM, supplemental US yielded similar CDRs in both DBT and DM cohorts (4.0 vs. 3.3 per 1000 examinations, respectively; P = 0.803) and higher AIR in the DBT cohort (24.8% [188 of 758; 95% CI: 21.8%–28.0%] vs. 16.9% [257 of 1516; 95% CI: 15.1%–18.9%; P < 0.001). @*Conclusion@#DBT screening combined with US showed comparable CDR but lower specificity than DM screening combined with US in women with dense breasts.

7.
Journal of Breast Cancer ; : 131-139, 2022.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-925165

RESUMEN

This study aimed to evaluate the imaging and pathological findings in axillary lymph nodes in patients with breast cancer who received concurrent ipsilateral coronavirus disease 2019 (COVID-19) vaccination. Of the 19 women with breast cancer who received concurrent COVID-19 vaccination shot in the arm ipsilateral to breast cancer, axillary lymphadenopathy was observed in 84.2% (16 of 19) of patients on ultrasound (US) and 71.4% (10 of 14) of patients on magnetic resonance imaging (MRI), and 21.0% (4 of 19) of patients were diagnosed with metastasis. Abnormal US and MRI findings of cortical thickening, effacement of the fatty hilum, round shape, and asymmetry in the number or size relative to the contralateral side were noted in more than half of the non-metastatic and metastatic lymph nodes; however, statistical significance was not noted. Axillary lymphadenopathy is commonly observed in patients with breast cancer who receive concurrent ipsilateral COVID-19 vaccination without specific differential imaging features. Thus, understanding the limitations of axillary imaging and cautious interpretation is necessary to avoid overestimation or underestimation of the axillary disease burden.

8.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-925173

RESUMEN

Purpose@#To evaluate the axillary recurrence rate and usefulness of axillary ultrasound (AUS) during supplementary whole-breast ultrasound (US) screening in women with a personal history of breast cancer (PHBC). @*Methods@#A retrospective database search identified consecutive asymptomatic women who underwent postoperative supplemental whole-breast US screening, including that of the bilateral axillae, after negative findings on mammography between January and June 2017. Using the pathologic data or at least 1-year follow-up data as reference standards, the axillary recurrence rate, cancer detection rate (CDR), interval axillary recurrence rate per 1,000 screenings, sensitivity, specificity, and abnormal interpretation rate (AIR) were estimated. @*Results@#From the data of 4,430 women (mean age, 55.0 ± 10.1 years) analyzed in this study, there were five axillary recurrence cases (1.1/1,000) in the median follow-up period of 57.2 months. AUS showed a CDR of 0.2 (1/4,430; 95% confidence interval [CI], 0.01–1.3) and an interval axillary recurrence rate of 0.9 (4/4,402; 95% CI, 0.2–2.3) per 1,000 examinations. The sensitivity and specificity were 20.0% (1/5; 95% CI, 0.5–71.6), and 99.4% (4,398/4,425; 95% CI, 99.1–99.6), respectively, while the AIR was 0.6% (28/4,430; 95% CI, 0.4–0.9%). @*Conclusion@#In asymptomatic women with a PHBC and negative findings on mammography, axillary recurrence after breast cancer and axillary treatment was uncommon, and the supplemental AUS screening yielded 0.2 cancers per 1,000 examinations.

9.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-938777

RESUMEN

Objective@#The optimal imaging approach for evaluating pathological nipple discharge remains unclear. We investigated the value of adding ductography to ultrasound (US) for evaluating pathologic nipple discharge in patients with negative mammography findings. @*Materials and Methods@#From July 2003 to December 2018, 101 women (mean age, 46.3 ± 12.2 years; range, 23–75 years) with pathologic nipple discharge were evaluated using pre-ductography (initial) US, ductography, and post-ductography US. The imaging findings were reviewed retrospectively. The standard reference was surgery (70 patients) or > 2 years of followup with US (31 patients). The diagnostic performances of initial US, ductography, and post-ductography US for detecting malignancy were compared using the McNemar’s test or a generalized estimating equation. @*Results@#In total, 47 papillomas, 30 other benign lesions, seven high-risk lesions, and 17 malignant lesions were identified as underlying causes of pathologic nipple discharge. Only eight of the 17 malignancies were detected on the initial US, while the remaining nine malignancies were detected by ductography. Among the nine malignancies detected by ductography, eight were detected on post-ductography US and could be localized for US-guided intervention. The sensitivities of ductography (94.1% [16/17]) and post-ductography US (94.1% [16/17]) were significantly higher than those of initial US (47.1% [8/17]; p = 0.027 and 0.013, respectively). The negative predictive value of post-ductography US (96.9% [31/32]) was significantly higher than that of the initial US (83.3% [45/54]; p = 0.006). Specificity was significantly higher for initial US than for ductography and post-ductography US (p = 0.001 for all). @*Conclusion@#The combined use of ductography and US has a high sensitivity for detecting malignancy in patients with pathologic nipple discharge and negative mammography. Ductography findings enable lesion localization on second-look post-ductography US, thus facilitating the selection of optimal treatment plans.

10.
Journal of Breast Cancer ; : 554-560, 2021.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-914826

RESUMEN

Axillary ultrasonography (US) is the most commonly used imaging modality for nodal evaluation in patients with breast cancer. No Axillary Surgical Treatment in Clinically Lymph Node-Negative Patients after Ultrasonography (NAUTILUS) is a prospective, multicenter, randomized controlled trial investigating whether sentinel lymph node biopsy (SLNB) can be safely omitted in patients with clinically and sonographically node-negative T1–2 breast cancer treated with breast-conserving therapy. In this trial, a standardized imaging protocol and criteria were established for the evaluation of axillary lymph nodes. Women lacking palpable lymph nodes underwent axillary US to dismiss suspicious nodal involvement.Patients with a round hypoechoic node with effaced hilum or indistinct margins were excluded. Patients with T1 tumors and a single node with a cortical thickness ≥ 3 mm underwent US-guided biopsy. Finally, patients with negative axillary US findings were included. The NAUTILUS axillary US nodal assessment criteria facilitate the proper selection of candidates who can omit SLNB.

11.
Journal of Breast Cancer ; : 455-462, 2021.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-914829

RESUMEN

Purpose@#The breast cancer susceptibility gene, BRCA1, is involved in normal development and carcinogenesis of mammary glands. Here, we aimed to evaluate the relationship between histological findings of mammary gland development and breast cancer risk in BRCA1 mutant mice. @*Methods@#Five BRCA1 mutant mice and five non-mutant FVB/NJ mice were used for each group of 1-month-old (pubertal), 3-month-old (fertile), and 8-month-old (menopausal) mice.In another experiment, 15 BRCA1 mutant mice were followed up to 8 months after birth and classified into tumor-bearing (11 mice) and tumor-free (4 mice) groups. Excised mammary gland tissues were stained with Carmine Alum, and the number of terminal end buds (or alveolar buds), branching density, and duct elongation were measured using image analysis programs. Differences between the two groups were assessed using paired t-test. @*Results@#One-month-old BRCA1 mutant mice showed a higher number of terminal end buds (23.8 ± 1.0 vs. 15.6 ± 0.8, p = 0.0002), branching density (11.7 ± 0.4 vs. 9.6 ± 0.5%, p = 0.0082), and duct elongation (9.7 ± 0.7 vs. 7.3 ± 0.4 mm, p= 0.0186) than controls. However, there was no difference between the 3- and 8-month-old groups. In BRCA1 mutant mice, the tumor-bearing group showed a significantly higher number of alveolar buds (142.7 ± 5.5 vs. 105.5 ± 5.4, p = 0.0008) and branching density (30.0 ± 1.0 vs. 24.1 ± 1.1%, p = 0.008) than the tumor-free group; however, duct elongation was not different (23.9 ± 0.6 vs. 23.6 ± 0.6 mm, p = 0.8099) between the groups. @*Conclusion@#BRCA1 mutant mice exhibited early pubertal mammary gland development and delayed age-related mammary gland involution was associated with breast cancer. Our results may have clinical implications for predicting breast cancer risk and developing prevention strategies for BRCA1 mutation carriers.

12.
Journal of Breast Cancer ; : 218-228, 2021.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-898979

RESUMEN

Purpose@#Interest in unenhanced magnetic resonance imaging (MRI) screening for breast cancer is growing due to concerns about gadolinium deposition in the brain and the high cost of contrast-enhanced MRI. The purpose of this report is to describe the protocol of the Diffusion-Weighted Magnetic Resonance Imaging Screening Trial (DWIST), which is a prospective, multicenter, intraindividual comparative cohort study designed to compare the performance of mammography, ultrasonography, dynamic contrast-enhanced (DCE) MRI, and diffusion-weighted (DW) MRI screening in women at high risk of developing breast cancer. @*Methods@#A total of 890 women with BRCA mutation or family history of breast cancer and lifetime risk ≥ 20% are enrolled. The participants undergo 2 annual breast screenings with digital mammography, ultrasonography, DCE MRI, and DW MRI at 3.0 T. Images are independently interpreted by trained radiologists. The reference standard is a combination of pathology and 12-month follow-up. Each image modality and their combination will be compared in terms of sensitivity, specificity, accuracy, positive predictive value, rate of invasive cancer detection, abnormal interpretation rate, and characteristics of detected cancers. The first participant was enrolled in April 2019. At the time of manuscript submission, 5 academic medical centers in South Korea are actively enrolling eligible women and a total of 235 women have undergone the first round of screening. Completion of enrollment is expected in 2022 and the results of the study are expected to be published in 2026.Discussion: DWIST is the first prospective multicenter study to compare the performance of DW MRI and conventional imaging modalities for breast cancer screening in high-risk women. DWIST is currently in the patient enrollment phase.

13.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-902452

RESUMEN

Objective@#To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. @*Materials and Methods@#Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. @*Results@#Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). @*Conclusion@#In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

14.
Journal of Breast Cancer ; : 218-228, 2021.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-891275

RESUMEN

Purpose@#Interest in unenhanced magnetic resonance imaging (MRI) screening for breast cancer is growing due to concerns about gadolinium deposition in the brain and the high cost of contrast-enhanced MRI. The purpose of this report is to describe the protocol of the Diffusion-Weighted Magnetic Resonance Imaging Screening Trial (DWIST), which is a prospective, multicenter, intraindividual comparative cohort study designed to compare the performance of mammography, ultrasonography, dynamic contrast-enhanced (DCE) MRI, and diffusion-weighted (DW) MRI screening in women at high risk of developing breast cancer. @*Methods@#A total of 890 women with BRCA mutation or family history of breast cancer and lifetime risk ≥ 20% are enrolled. The participants undergo 2 annual breast screenings with digital mammography, ultrasonography, DCE MRI, and DW MRI at 3.0 T. Images are independently interpreted by trained radiologists. The reference standard is a combination of pathology and 12-month follow-up. Each image modality and their combination will be compared in terms of sensitivity, specificity, accuracy, positive predictive value, rate of invasive cancer detection, abnormal interpretation rate, and characteristics of detected cancers. The first participant was enrolled in April 2019. At the time of manuscript submission, 5 academic medical centers in South Korea are actively enrolling eligible women and a total of 235 women have undergone the first round of screening. Completion of enrollment is expected in 2022 and the results of the study are expected to be published in 2026.Discussion: DWIST is the first prospective multicenter study to compare the performance of DW MRI and conventional imaging modalities for breast cancer screening in high-risk women. DWIST is currently in the patient enrollment phase.

15.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-894748

RESUMEN

Objective@#To compare the screening performance of diffusion-weighted (DW) MRI and combined mammography and ultrasound (US) in detecting clinically occult contralateral breast cancer in women with newly diagnosed breast cancer. @*Materials and Methods@#Between January 2017 and July 2018, 1148 women (mean age ± standard deviation, 53.2 ± 10.8 years) with unilateral breast cancer and no clinical abnormalities in the contralateral breast underwent 3T MRI, digital mammography, and radiologist-performed whole-breast US. In this retrospective study, three radiologists independently and blindly reviewed all DW MR images (b = 1000 s/mm2 and apparent diffusion coefficient map) of the contralateral breast and assigned a Breast Imaging Reporting and Data System category. For combined mammography and US evaluation, prospectively assessed results were used. Using histopathology or 1-year follow-up as the reference standard, cancer detection rate and the patient percentage with cancers detected among all women recommended for tissue diagnosis (positive predictive value; PPV2) were compared. @*Results@#Of the 30 cases of clinically occult contralateral cancers (13 invasive and 17 ductal carcinoma in situ [DCIS]), DW MRI detected 23 (76.7%) cases (11 invasive and 12 DCIS), whereas combined mammography and US detected 12 (40.0%, five invasive and seven DCIS) cases. All cancers detected by combined mammography and US, except two DCIS cases, were detected by DW MRI. The cancer detection rate of DW MRI (2.0%; 95% confidence interval [CI]: 1.3%, 3.0%) was higher than that of combined mammography and US (1.0%; 95% CI: 0.5%, 1.8%; p = 0.009). DW MRI showed higher PPV2 (42.1%; 95% CI: 26.3%, 59.2%) than combined mammography and US (18.5%; 95% CI: 9.9%, 30.0%; p = 0.001). @*Conclusion@#In women with newly diagnosed breast cancer, DW MRI detected significantly more contralateral breast cancers with fewer biopsy recommendations than combined mammography and US.

16.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-875138

RESUMEN

Diffusion-weighted magnetic resonance imaging (DW MRI) is a fast unenhanced technique that shows promise as a stand-alone modality for cancer screening and characterization. Currently, DW MRI may have lower sensitivity than that of dynamic contrast-enhanced MRI as a standalone modality for breast cancer detection but superior to that of mammography, which may provide a useful alternative for supplemental screening. Standardized acquisition and interpretation of DW MRI can improve the image quality and reduce the variability of the results. Furthermore, high-resolution DW MRI, with advanced techniques and postprocessing, will facilitate better detection and characterization of subcentimeter cancers and reduce false-negatives and false-positives. Future results from ongoing prospective multicenter clinical trials using standardized and optimized protocols will facilitate the use of DW MRI as a stand-alone modality.

17.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-875273

RESUMEN

Diffusion-weighted (DW) magnetic resonance imaging (MRI) is a rapid, unenhanced imaging technique that measures the motion of water molecules within tissues and provides information regarding the cell density and tissue microstructure. DW MRI has demonstrated the potential to improve the specificity of breast MRI, facilitate the evaluation of tumor response to neoadjuvant chemotherapy and can be employed in unenhanced MRI screening. However, standardization of the acquisition and interpretation of DW MRI is challenging. Recently, the European Society of Breast Radiology issued a consensus statement, which described the acquisition parameters and interpretation of DW MRI. The current article describes the basic principles, standardized acquisition protocols and interpretation guidelines, and the clinical applications of DW MRI in breast imaging.

18.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-875283

RESUMEN

Objective@#To compare the performance of simulated abbreviated breast MRI (AB-MRI) and full diagnostic (FD)-MRI in distinguishing between benign and malignant lesions detected by MRI and investigate the features of discrepant lesions of the two protocols. @*Materials and Methods@#An AB-MRI set with single first postcontrast images was retrospectively obtained from an FD-MRI cohort of 111 lesions (34 malignant, 77 benign) detected by contralateral breast MRI in 111 women (mean age, 49.8. ± 9.8;range, 28–75 years) with recently diagnosed breast cancer. Five blinded readers independently classified the likelihood of malignancy using Breast Imaging Reporting and Data System assessments. McNemar tests and area under the receiver operating characteristic curve (AUC) analyses were performed. The imaging and pathologic features of the discrepant lesions of the two protocols were analyzed. @*Results@#The sensitivity of AB-MRI for lesion characterization tended to be lower than that of FD-MRI for all readers (58.8– 82.4% vs. 79.4–100%), although the findings of only two readers were significantly different (p 0.05). Fifteen percent (5/34) of the cancers were false-negatives on AB-MRI. More suspicious margins or internal enhancement on the delayed phase images were related to the discrepancies. @*Conclusion@#The overall performance of AB-MRI was similar to that of FD-MRI in distinguishing between benign and malignant lesions. AB-MRI showed lower sensitivity and higher specificity than FD-MRI, as 15% of the cancers were misclassified compared to FD-MRI.

19.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-782172

RESUMEN

0.05).CONCLUSION: 2-VST of ABUS achieved comparable scan coverage and diagnostic performance to that of conventional 3-VST in women with small breasts.


Asunto(s)
Femenino , Humanos , Neoplasias de la Mama , Mama , Sensibilidad y Especificidad , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA