Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Cardiovasc Magn Reson ; 15: 61, 2013 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-23870697

RESUMEN

BACKGROUND: Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS: We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture needles, which were exchanged for pericardial catheters. To test the value of CMR needle pericardiocentesis, we also created intentional pericardial effusions of a range of volumes, via a separate transvenous-transatrial catheter. We performed these procedures in 12 animals. CONCLUSIONS: CMR guided pericardiocentesis is attractive because the large field of view and soft tissue imaging depict global anatomic context in arbitrary planes, and allow the operator to plan trajectories that limit inadvertent bystander tissue injury. More important, CMR provides continuous visualization of the needle and target throughout the procedure. Using even passive needle devices, CMR enabled rapid pericardial needle access and drainage. We believe this experience supports clinical testing of real-time CMR guided needle access or drainage of the pericardial space. We suspect this would be especially helpful in "difficult" pericardial access, for example, in distorted thoracic anatomy or loculated effusion.


Asunto(s)
Catéteres , Imagen por Resonancia Magnética Intervencional , Derrame Pericárdico/terapia , Pericardiocentesis/instrumentación , Pericardiocentesis/métodos , Animales , Modelos Animales de Enfermedad , Diseño de Equipo , Hemodinámica , Agujas , Derrame Pericárdico/fisiopatología , Pericardiocentesis/efectos adversos , Punciones , Porcinos , Factores de Tiempo
2.
J Cardiovasc Magn Reson ; 15: 10, 2013 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-23331459

RESUMEN

BACKGROUND: We aim to deliver large appliances into the left ventricle through the right ventricle and across the interventricular septum. This transthoracic access route exploits immediate recoil of the septum, and lower transmyocardial pressure gradient across the right versus left ventricular free wall. The route may enhance safety and allow subxiphoid rather than intercostal traversal. METHODS: The entire procedure was performed under real-time CMR guidance. An "active" CMR needle crossed the chest, right ventricular free wall, and then the interventricular septum to deliver a guidewire then used to deliver an 18Fr introducer. Afterwards, the right ventricular free wall was closed with a nitinol occluder. Immediate closure and late healing of the unrepaired septum and free wall were assessed by oximetry, angiography, CMR, and necropsy up to four weeks afterwards. RESULTS: The procedure was successful in 9 of 11 pigs. One failed because of refractory ventricular fibrillation upon needle entry, and the other because of inadequate guidewire support. In all ten attempts, the right ventricular free wall was closed without hemopericardium. There was neither immediate nor late shunt on oximetry, X-ray angiography, or CMR. The interventricular septal tract fibrosed completely. Transventricular trajectories planned on human CT scans suggest comparable intracavitary working space and less acute entry angles than a conventional atrial transseptal approach. CONCLUSION: Large closed-chest access ports can be introduced across the right ventricular free wall and interventricular septum into the left ventricle. The septum recoils immediately and heals completely without repair. A nitinol occluder immediately seals the right ventricular wall. The entry angle is more favorable to introduce, for example, prosthetic mitral valves than a conventional atrial transseptal approach.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Ventrículos Cardíacos/patología , Imagen por Resonancia Magnética Intervencional , Dispositivo Oclusor Septal , Tabique Interventricular/patología , Anciano , Aleaciones , Animales , Catéteres Cardíacos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/terapia , Estudios de Factibilidad , Femenino , Fibrosis , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Modelos Animales , Diseño de Prótesis , Punciones , Porcinos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Función Ventricular , Tabique Interventricular/diagnóstico por imagen , Tabique Interventricular/fisiopatología , Cicatrización de Heridas
3.
Eur Heart J ; 34(5): 380-9, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22855740

RESUMEN

AIMS: Real-time MRI creates images with superb tissue contrast that may enable radiation-free catheterization. Simple procedures are the first step towards novel interventional procedures. We aim to perform comprehensive transfemoral diagnostic right heart catheterization in an unselected cohort of patients entirely using MRI guidance. METHODS AND RESULTS: We performed X-ray and MRI-guided transfemoral right heart catheterization in consecutive patients undergoing clinical cardiac catheterization. We sampled both cavae and both pulmonary arteries. We compared success rate, time to perform key steps, and catheter visibility among X-ray and MRI procedures using air-filled or gadolinium-filled balloon-tipped catheters. Sixteen subjects (four with shunt, nine with coronary artery disease, three with other) underwent paired X-ray and MRI catheterization. Complete guidewire-free catheterization was possible in 15 of 16 under both. MRI using gadolinium-filled balloons was at least as successful as X-ray in all procedure steps, more successful than MRI using air-filled balloons, and better than both in entering the left pulmonary artery. Total catheterization time and individual procedure steps required approximately the same amount of time irrespective of image guidance modality. Catheter conspicuity was best under X-ray and next-best using gadolinium-filled MRI balloons. CONCLUSION: In this early experience, comprehensive transfemoral right heart catheterization appears feasible using only MRI for imaging guidance. Gadolinium-filled balloon catheters were more conspicuous than air-filled ones. Further workflow and device enhancement are necessary for clinical adoption.


Asunto(s)
Cateterismo Cardíaco/métodos , Cardiopatías/diagnóstico , Medios de Contraste , Estudios de Factibilidad , Femenino , Gadolinio , Humanos , Angiografía por Resonancia Magnética/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Radiografía Intervencional/métodos
4.
JACC Cardiovasc Interv ; 4(12): 1326-34, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22192373

RESUMEN

OBJECTIVES: The aim of this study was to close ventricular septal defects (VSDs) directly through the chest wall using magnetic resonance imaging (MRI) guidance, without cardiopulmonary bypass, sternotomy, or radiation exposure. BACKGROUND: Surgical, percutaneous, and hybrid management of VSD each have limitations and known morbidity. METHODS: Percutaneous muscular VSDs were created in 10 naive Yorkshire swine using a transjugular laser catheter. Under real-time MRI guidance, a direct transthoracic vascular access sheath was introduced through the chest into the heart along a trajectory suitable for VSD access and closure. Through this transthoracic sheath, muscular VSDs were occluded using a commercial nitinol device. Finally, the right ventricular free wall was closed using a commercial collagen plug intended for arterial closure. RESULTS: Anterior, posterior, and mid-muscular VSDs (6.8 ± 1.8 mm) were created. VSDs were closed successfully in all animals. The transthoracic access sheath was displaced in 2, both fatal. Thereafter, we tested an intracameral retention sheath to prevent this complication. Right ventricular access ports were closed successfully in all, and after as many as 30 days, healed successfully. CONCLUSIONS: Real-time MRI guidance allowed closed-chest transthoracic perventricular muscular VSD closure in a clinically meaningful animal model. Once applied to patients, this approach may avoid traditional surgical, percutaneous, or open-chest transcatheter ("hybrid") risks.


Asunto(s)
Cateterismo Cardíaco , Defectos del Tabique Interventricular/terapia , Imagen por Resonancia Magnética Intervencional , Animales , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Modelos Animales de Enfermedad , Defectos del Tabique Interventricular/patología , Diseño de Prótesis , Dispositivo Oclusor Septal , Porcinos , Factores de Tiempo
5.
J Am Coll Cardiol ; 54(7): 638-51, 2009 Aug 11.
Artículo en Inglés | MEDLINE | ID: mdl-19660696

RESUMEN

OBJECTIVES: We developed and tested a novel transcatheter circumferential annuloplasty technique to reduce mitral regurgitation in porcine ischemic cardiomyopathy. BACKGROUND: Catheter-based annuloplasty for secondary mitral regurgitation exploits the proximity of the coronary sinus to the mitral annulus, but is limited by anatomic variants and coronary artery entrapment. METHODS: The procedure, "cerclage annuloplasty," is guided by magnetic resonance imaging (MRI) roadmaps fused with live X-ray. A coronary sinus guidewire traverses a short segment of the basal septal myocardium to re-enter the right heart where it is exchanged for a suture. Tension is applied interactively during imaging and secured with a locking device. RESULTS: We found 2 feasible suture pathways from the great cardiac vein across the interventricular septum to create cerclage. Right ventricular septal re-entry required shorter fluoroscopy times than right atrial re-entry, which entailed a longer intramyocardial traversal but did not cross the tricuspid valve. Graded tension progressively reduced septal-lateral annular diameter, but not end-systolic elastance or regional myocardial function. A simple arch-like device protected entrapped coronary arteries from compression even during supratherapeutic tension. Cerclage reduced mitral regurgitation fraction (from 22.8 +/- 12.7% to 7.2 +/- 4.4%, p = 0.04) by slice tracking velocity-encoded MRI. Flexible cerclage reduced annular size but preserved annular motion. Cerclage also displaced the posterior annulus toward the papillary muscles. Cerclage introduced reciprocal constraint to the left ventricular outflow tract and mitral annulus that enhanced leaflet coaptation. A sample of human coronary venograms and computed tomography angiograms suggested that most have suitable venous anatomy for cerclage. CONCLUSIONS: Transcatheter mitral cerclage annuloplasty acutely reduces mitral regurgitation in porcine ischemic cardiomyopathy. Entrapped coronary arteries can be protected. MRI provided insight into the mechanism of cerclage action.


Asunto(s)
Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Animales , Vasos Coronarios/anatomía & histología , Fluoroscopía , Tabiques Cardíacos/anatomía & histología , Imagen por Resonancia Magnética , Válvula Mitral/anatomía & histología , Insuficiencia de la Válvula Mitral/etiología , Isquemia Miocárdica/complicaciones , Cirugía Asistida por Computador , Técnicas de Sutura , Porcinos , Procedimientos Quirúrgicos Vasculares/métodos
6.
J Vasc Interv Radiol ; 19(9): 1347-53, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-18725098

RESUMEN

PURPOSE: The authors performed this study to report their initial preclinical experience with real-time magnetic resonance (MR) imaging-guided atrial septal puncture by using a MR imaging-conspicuous blunt laser catheter that perforates only when energized. MATERIALS AND METHODS: The authors customized a 0.9-mm clinical excimer laser catheter with a receiver coil to impart MR imaging visibility at 1.5 T. Seven swine underwent laser transseptal puncture under real-time MR imaging. MR imaging signal-to-noise ratio profiles of the device were obtained in vitro. Tissue traversal force was tested with a calibrated meter. Position was corroborated with pressure measurements, oximetry, angiography, and necropsy. Intentional non-target perforation simulated serious complication. RESULTS: Embedded MR imaging antennae accurately reflected the position of the laser catheter tip and profile in vitro and in vivo. Despite having an increased profile from the microcoil, the 0.9-mm laser catheter traversed in vitro targets with similar force (0.22 N +/- 0.03) compared with the unmodified laser. Laser puncture of the atrial septum was successful and accurate in all animals. The laser was activated an average of 3.8 seconds +/- 0.4 before traversal. There were no sequelae after 6 hours of observation. Necropsy revealed 0.9-mm holes in the fossa ovalis in all animals. Intentional perforation of the aorta and atrial free wall was evident immediately. CONCLUSIONS: MR imaging-guided laser puncture of the interatrial septum is feasible in swine and offers controlled delivery of perforation energy by using an otherwise blunt catheter. Instantaneous soft tissue imaging provides immediate feedback on safety.


Asunto(s)
Tabique Interatrial/cirugía , Terapia por Láser/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Cirugía Asistida por Computador/métodos , Animales , Porcinos
7.
Catheter Cardiovasc Interv ; 67(4): 637-43, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16532499

RESUMEN

Cardiac perforation during atrial septal puncture (ASP) might be avoided by improved image guidance. X-ray fluoroscopy (XRF), which guides ASP, visualizes tissue poorly and does not convey depth information. Ultrasound is limited by device shadows and constrained imaging windows. Alternatively, real-time MRI (rtMRI) provides excellent tissue contrast in any orientation and may enable ASP and balloon atrial septostomy (BAS) in swine. Custom MRI catheters incorporated "active" (receiver antenna) and "passive" (iron or gadolinium) elements. Wholly rtMRI-guided transfemoral ASP and BAS were performed in 10 swine in a 1.5T interventional suite. Hemodynamic results were measured with catheters and velocity encoded MRI. Successful ASP was performed in all 10 animals. Necropsy confirmed septostomy confined within the fossa ovalis in all. BAS was successful in 9/10 animals. Antenna failure in a re-used needle led to inadvertent vena cava tear prior to BAS in 1 animal. ASP in the same animal was easily performed using a new needle. rtMRI illustrated clear device-tissue-lumen relationships in multiple orientations, and facilitated simple ASP and BAS. The mean procedure time was 19 +/- 10 minutes. Septostomy achieved a mean left to right shunt ratio of 1.3:1 in these healthy animals. Interactive rtMRI permits rapid transcatheter ASP and BAS in swine. Further technical development may enable novel applications.


Asunto(s)
Angioplastia Coronaria con Balón , Atrios Cardíacos/cirugía , Tabiques Cardíacos/cirugía , Imagen por Resonancia Magnética/métodos , Punciones/métodos , Cirugía Asistida por Computador , Animales , Cateterismo Cardíaco , Porcinos
8.
Circulation ; 113(8): 1101-7, 2006 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-16490819

RESUMEN

BACKGROUND: Endovascular recanalization (guidewire traversal) of peripheral artery chronic total occlusion (CTO) can be challenging. X-ray angiography resolves CTO poorly. Virtually "blind" device advancement during x-ray-guided interventions can lead to procedure failure, perforation, and hemorrhage. Alternatively, MRI may delineate the artery within the occluded segment to enhance procedural safety and success. We hypothesized that real-time MRI (rtMRI)-guided CTO recanalization can be accomplished in an animal model. METHODS AND RESULTS: Carotid artery CTO was created by balloon injury in 19 lipid-overfed swine. After 6 to 8 weeks, 2 underwent direct necropsy analysis for histology, 3 underwent primary x-ray-guided CTO recanalization attempts, and the remaining 14 underwent rtMRI-guided recanalization attempts in a 1.5-T interventional MRI system. Real-time MRI intervention used custom CTO catheters and guidewires that incorporated MRI receiver antennae to enhance device visibility. The mean length of the occluded segments was 13.3+/-1.6 cm. The rtMRI-guided CTO recanalization was successful in 11 of 14 swine and in only 1 of 3 swine with the use of x-ray alone. After unsuccessful rtMRI (n=3), x-ray-guided attempts were also unsuccessful. CONCLUSIONS: Recanalization of long CTO is entirely feasible with the use of rtMRI guidance. Low-profile clinical-grade devices will be required to translate this experience to humans.


Asunto(s)
Arteriopatías Oclusivas/terapia , Cateterismo/métodos , Imagen por Resonancia Magnética , Angioplastia/instrumentación , Angioplastia/métodos , Animales , Arteriopatías Oclusivas/patología , Enfermedades de las Arterias Carótidas/patología , Enfermedades de las Arterias Carótidas/terapia , Cateterismo/instrumentación , Enfermedad Crónica , Modelos Animales de Enfermedad , Diseño de Equipo , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Enfermedades Vasculares Periféricas/patología , Enfermedades Vasculares Periféricas/terapia , Porcinos , Resultado del Tratamiento
9.
Circulation ; 112(5): 699-706, 2005 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-16043639

RESUMEN

BACKGROUND: Real-time MR imaging (rtMRI) is now technically capable of guiding catheter-based cardiovascular interventions. Compared with x-ray, rtMRI offers superior tissue imaging in any orientation without ionizing radiation. Translation to clinical trials has awaited the availability of clinical-grade catheter devices that are both MRI visible and safe. We report a preclinical safety and feasibility study of rtMRI-guided stenting in a porcine model of aortic coarctation using only commercially available catheter devices. METHOD AND RESULTS: Coarctation stenting was performed wholly under rtMRI guidance in 13 swine. rtMRI permitted procedure planning, device tracking, and accurate stent deployment. "Active" guidewires, incorporating MRI antennas, improved device visualization compared with unmodified "passive" nitinol guidewires and shortened procedure time (26+/-11 versus 106+/-42 minutes; P=0.008). Follow-up catheterization and necropsy showed accurate stent deployment, durable gradient reduction, and appropriate neointimal formation. MRI immediately identified aortic rupture when oversized devices were tested. CONCLUSIONS: This experience demonstrates preclinical safety and feasibility of rtMRI-guided aortic coarctation stenting using commercially available catheter devices. Patients may benefit from rtMRI in the future because of combined device and tissue imaging, freedom from ionizing radiation, and the ability to identify serious complications promptly.


Asunto(s)
Coartación Aórtica/cirugía , Imagen por Resonancia Magnética/métodos , Stents , Animales , Coartación Aórtica/diagnóstico por imagen , Cateterismo , Sistemas de Computación , Diseño de Equipo , Modelos Animales , Radiografía , Porcinos
10.
Catheter Cardiovasc Interv ; 64(3): 265-74, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15736247

RESUMEN

We tested the feasibility and safety of invasive magnetic resonance imaging (MRI) during peripheral angioplasty. Real-time MRI can image soft tissue and may potentially guide therapeutic procedures without ionizing radiation or nephrotoxic contrast. MRI-guided diagnostic catheterization has been described recently, but safe and conspicuous catheter devices are not widely available. An active guidewire, which serves as an MRI receiver antenna, might be useful to guide catheterization or even to image atheroma. We describe a combined interventional suite offering both X-ray fluoroscopy and real-time MRI. We used a 0.030'' active guidewire receiver coil for invasive MRI after X-ray lesion traversal in patients undergoing percutaneous iliofemoral artery revascularization. Intravascular MRI was compared with noninvasive MRI, X-ray angiography, and intravascular ultrasound (IVUS). Seven eligible patients consented to participate, but three were excluded because of lengthy revascularization procedures. Four remaining patients safely underwent combined X-ray fluoroscopy and real-time magnetic resonance imaging (XMR) transport, continuous monitoring, and all imaging modalities. There was no device dislodgment, contamination or evidence of heating. The intravascular MRI coil was well visualized except at the tip, but did not provide superior mural imaging compared with IVUS. Therefore, because an adequate safety and workflow experience was obtained, enrollment was terminated after only four subjects. Invasive MRI is feasible and apparently safe during peripheral angioplasty. Patients can safely be transported and monitored in an XMR interventional suite. An active quarter-wavelength guidewire coil does not provide superior imaging compared with IVUS, but provides satisfactory guidewire visualization. These tools may prove useful for advanced therapeutic procedures in the future.


Asunto(s)
Angioplastia de Balón , Claudicación Intermitente/diagnóstico , Angiografía por Resonancia Magnética , Quirófanos , Servicio de Radiología en Hospital , Anciano , Angiografía , Seguridad de Equipos , Estudios de Factibilidad , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/patología , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Claudicación Intermitente/terapia , Periodo Intraoperatorio , Angiografía por Resonancia Magnética/instrumentación , Angiografía por Resonancia Magnética/normas , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...