Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
2.
World J Urol ; 42(1): 302, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38720010

RESUMEN

PURPOSE: To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ-CEUS) by comparing with contrast-enhanced computed tomography (CE-CT) and contrast-enhanced magnetic resonance imaging (CE-MRI) for differentiating benign and malignant renal masses. MATERIALS AND METHODS: 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ-CEUS, CE-CT or CE-MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar's test. RESULTS: In the head-to-head comparison, SNZ-CEUS and CE-MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ-CEUS and CE-CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ-CEUS had relatively lower than specificity than CE-CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE-MRI demonstrated higher specificity than SNZ-CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. CONCLUSIONS: SNZ-CEUS, CE-CT, and CE-MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ-CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.


Asunto(s)
Medios de Contraste , Compuestos Férricos , Hierro , Neoplasias Renales , Imagen por Resonancia Magnética , Óxidos , Tomografía Computarizada por Rayos X , Ultrasonografía , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Ultrasonografía/métodos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética/métodos , Anciano , Diagnóstico Diferencial , Adulto , Anciano de 80 o más Años
4.
Radiology ; 307(5): e221408, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37367448

RESUMEN

Background Current guidelines recommend the use of conventional US for risk stratification and management of thyroid nodules. However, fine-needle aspiration (FNA) is often recommended in benign nodules. Purpose To compare the diagnostic performance of multimodality US (including conventional US, strain elastography, and contrast-enhanced US [CEUS]) with the American College of Radiology Thyroid Imaging Reporting and Data System (TI-RADS) in the recommendation of FNA for thyroid nodules to reduce unnecessary biopsies. Materials and Methods In this prospective study, 445 consecutive participants with thyroid nodules from nine tertiary referral hospitals were recruited between October 2020 and May 2021. With univariable and multivariable logistic regression, the prediction models incorporating sonographic features, evaluated with interobserver agreement, were constructed and internally validated with bootstrap resampling technique. In addition, discrimination, calibration, and decision curve analysis were performed. Results A total of 434 thyroid nodules confirmed at pathologic analysis (259 malignant thyroid nodules) in 434 participants (mean age, 45 years ± 12 [SD]; 307 female participants) were included. Four multivariable models incorporated participant age, nodule features at US (proportion of cystic components, echogenicity, margin, shape, punctate echogenic foci), elastography features (stiffness), and CEUS features (blood volume). In recommending FNA in thyroid nodules, the highest area under the receiver operating characteristic curve (AUC) was 0.85 (95% CI: 0.81, 0.89) for the multimodality US model, and the lowest AUC was 0.63 (95% CI: 0.59, 0.68) for TI-RADS (P < .001). At the 50% risk threshold, 31% (95% CI: 26, 38) of FNA procedures could be avoided with multimodality US compared with 15% (95% CI: 12, 19) with TI-RADS (P < .001). Conclusion Multimodality US had better performance in recommending FNA to avoid unnecessary biopsies than the TI-RADS. Clinical trial registration no. NCT04574258 © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
Nódulo Tiroideo , Adulto , Femenino , Humanos , Persona de Mediana Edad , Biopsia con Aguja Fina , Imagen Multimodal , Estudios Prospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos
5.
J Clin Ultrasound ; 50(7): 953-954, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35900308

RESUMEN

Cavernous hemangioma is a rare, benign tumor and usually uncommon in adults. It is often difficult to diagnose in time because conventional medical imaging examinations usually fail to provide valid information. Clinicians should attach importance to the value of contrast-enhanced ultrasound as an adjunct to rapidly diagnose cavernous hemangioma.


Asunto(s)
Hemangioma Cavernoso , Adulto , Hemangioma Cavernoso/diagnóstico por imagen , Hemangioma Cavernoso/patología , Humanos , Tomografía Computarizada por Rayos X , Ultrasonografía
6.
Curr Med Sci ; 42(3): 642-649, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35583588

RESUMEN

OBJECTIVE: The influence of the coronary artery anatomy on the prognosis of patients receiving an arterial switch operation (ASO) is currently controversial, and the risk factors for this operation may change in more complicated patients. This study aimed to investigate the influence of coronary artery anomalies on the in-hospital and post-discharge outcomes of ASO in patients with transposition of the great arteries (TGA) and Taussig-Bing anomaly (TBA). METHODS: We retrospectively reviewed 206 patients who underwent ASO from January 2007 to December 2019. The median age at operation was 33 [interquartile range (IQR): 20-71] days. Median follow-up time was 7.2 years (IQR: 4.0-10.3 years). RESULTS: Coronary anomalies were present in 86 patients (41.7%), with 9 (4.4%) of them having a single coronary artery. Additional coronary features included intramural courses in 5 (2.4%) patients, ostial stenosis in 1 (0.5%) patient, and accessory coronary artery orifices in 5 (2.4%) patients. There were 32 (15.5%) in-hospital deaths and 8 (4.6%) post-discharge deaths, yielding an overall survival of 81.3%, 80.7% and 79.9% at 1, 5 and 10 years, respectively. Mortality due to ASO has been drastically decreased since 2013. Patients with a single coronary artery had higher rate of in-hospital mortality, but this finding was not statistically significant. The earlier surgical era (OR: 2.756) and a longer cardiopulmonary bypass time (OR: 2.336) were significantly associated with in-hospital mortality, while coronary patterns were not. An intramural coronary artery (HR: 10.034) and a patient age of older than 1 year at the time of ASO (HR: 9.706) were independent predictors of post-discharge mortality. CONCLUSION: ASO remains the procedure of choice for TGA with coronary anomalies with acceptable in-hospital and post-discharge outcomes in terms of overall survival and freedom of reoperation. However, intramural coronary artery is an independent risk factor for post-discharge mortality. Timely surgery within the 1st year of life helps improve overall midterm survival of ASO.


Asunto(s)
Operación de Switch Arterial , Transposición de los Grandes Vasos , Cuidados Posteriores , Operación de Switch Arterial/efectos adversos , Operación de Switch Arterial/métodos , Vasos Coronarios/cirugía , Hospitales , Humanos , Alta del Paciente , Estudios Retrospectivos , Transposición de los Grandes Vasos/etiología , Transposición de los Grandes Vasos/cirugía
8.
J Dermatol ; 46(2): 154-157, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30565282

RESUMEN

Vohwinkel syndrome (VS) is a rare autosomal dominant condition, also known as mutilating palmoplantar keratoderma accompanied by sensorineural deafness. The LOR and GJB2 genes are reported to be responsible for VS. The GJB2 gene encodes connexin 26, a component of intercellular gap junctions expressed in various tissues. We report the case of a 31-year-old Chinese woman with classic VS characterized by sensorineural deafness and mutilating palmoplantar keratoderma. Further genetic studies demonstrated a nucleotide change (c.175G>A) in the GJB2 gene, leading to an amino acid alteration (G59S). This identical missense mutation (G59S) has also been reported in a patient with Bart-Pumphrey syndrome. Together with our findings and previous studies, we conclude that the identical mutation (G59S) in the GJB2 gene contributes to various manifestations.


Asunto(s)
Anomalías Múltiples/genética , Conexinas/genética , Deformidades Congénitas de la Mano/genética , Pérdida Auditiva Sensorineural/genética , Queratodermia Palmoplantar/genética , Adulto , Pueblo Asiatico , Conexina 26 , Femenino , Humanos , Mutación Missense
9.
J Mol Cell Cardiol ; 123: 139-149, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-30227118

RESUMEN

Disruption of carotid vulnerable atherosclerotic plaque is responsible for acute ischemic stroke (AIS) and the early detection and intervention approach are greatly limited. Undertaking a microarray of microRNAs (miRNAs) in the plasma of AIS patients with carotid vulnerable plaques, miR-23a-5p was markedly elevated and was positively correlated with the plaque progression and vulnerability. Correspondingly, we found that miR-23a-5p expression was significantly increased in both plasma and macrophages from atherosclerosis mice. Bioinformatics analysis and in vitro knockdown experiments identified that ATP-binding cassette transporter A1/G1 as a novel target of miR-23a-5p. Luciferase reporter assays showed that miR-23a-5p repressed the 3' untranslated regions (UTR) activity of ABCA1/G1. Moreover, functional analyses demonstrated that transfection of miR-23a-5p inhibitor enhanced cholesterol efflux and decreased foam cell formation through upregulating ABCA1/G1 expression levels. Furthermore, long term in vivo systemically delivered miR-23a-5p antagomir significantly increased ABCA1/G1 expression in the aorta of ApoE-/- mice. Importantly, the miR-23a-5p antagomir therapy significantly reduced atherosclerosis progression and promoted plaque stability. Our observations indicate that miR-23a-5p promotes macrophage-derived foam cell formation and might be a key regulator contributing to atherosclerotic plaque progression and vulnerability.


Asunto(s)
Transportador 1 de Casete de Unión a ATP/genética , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 1/genética , Macrófagos/metabolismo , MicroARNs/genética , Placa Aterosclerótica/genética , Placa Aterosclerótica/metabolismo , Regiones no Traducidas 3' , Transportador 1 de Casete de Unión a ATP/metabolismo , Transportador de Casetes de Unión a ATP, Subfamilia G, Miembro 1/metabolismo , Animales , Modelos Animales de Enfermedad , Progresión de la Enfermedad , Perfilación de la Expresión Génica , Regulación de la Expresión Génica , Humanos , Masculino , Ratones , Ratones Noqueados , Modelos Biológicos , Placa Aterosclerótica/patología , Células RAW 264.7 , Interferencia de ARN
10.
J Huazhong Univ Sci Technolog Med Sci ; 37(5): 782-786, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29058296

RESUMEN

The intubation of conventional transesophageal echocardiography (TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit (ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect (ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment.


Asunto(s)
Cateterismo Cardíaco/métodos , Ecocardiografía/instrumentación , Defectos del Tabique Interatrial/diagnóstico por imagen , Intubación Gastrointestinal/instrumentación , Ecocardiografía Transesofágica , Femenino , Humanos , Masculino , Proyectos de Investigación , Ultrasonografía Intervencional
11.
J Huazhong Univ Sci Technolog Med Sci ; 37(4): 596-604, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28786055

RESUMEN

Accurate prenatal diagnosis of complex congenital cardiovascular anomalies, vascular ones in particular, is still challenging. A fetal cardiovascular cast model can provide a copy of the cardiac chambers and great vessels with normal or pathological structures. This study was aimed to demonstrate three-dimensional anatomy of complex congenital cardiovascular anomalies in fetuses by means of corrosion casting. Twenty fetuses with prenatal-ultrasound-diagnosed complex cardiovascular anomalies were enrolled in this study (19 to 35 gestational weeks). Fetal cardiovascular cast models were made by a corrosion casting technique. The specimens were injected with casting material via the umbilical vein, and then immersed in strong acid after casting fluid was solidified, to disclose the geometries of cardiovascular cavities. Nineteen cast models were successfully made from 20 specimens. The casts distinctly showed the morphological malformations and spatial relationship between cardiac chambers and great vessels. One hundred and eleven abnormalities were revealed by casting in the 19 specimens, including 34 abnormalities located in the cardiac chambers (3, 4 and 27 anomalies in the atria, atrioventricular valves and ventricles, respectively), and 77 in the great vessels (28, 20, 24 and 5 anomalies in the aorta and its branches, the pulmonary artery, the ductus arteriosus and the major veins, respectively). Corrosion casting can display three-dimensional anatomy of fetal complex cardiovascular anomalies. This improves our understanding of related pathomorphology and prenatal diagnosis.


Asunto(s)
Molde por Corrosión , Corazón Fetal/patología , Cardiopatías Congénitas/patología , Adulto , Femenino , Corazón Fetal/anomalías , Ventrículos Cardíacos/anomalías , Ventrículos Cardíacos/patología , Humanos , Masculino , Adulto Joven
12.
Medicine (Baltimore) ; 96(17): e6711, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28445281

RESUMEN

Intraventricular hydrodynamics plays an important role in evaluating cardiac function. Relationship between diastolic vortex and left ventricular (LV) filling is still rarely elucidated. The aim of this study was to evaluate the evolution of vortex during diastole in hyperthyroidism (HT) and explore the alteration of hydromechanics characteristics with sensitive indexes.Forty-three patients diagnosed with HT were classified into 2 groups according to whether myocardial damage existed: simple hyperthyroid group (HT1, n = 21) and thyrotoxic cardiomyopathy (HT2, n = 22). Twenty-seven age- and gender-matched healthy volunteers were enrolled as the control group. Offline vector flow mapping (VFM model) was used to analyze the LV diastolic blood flow patterns and fluid dynamics. Hemodynamic parameters, vortex area (A), circulation (C), and intraventricular pressure gradient (ΔP), in different diastolic phases (early, mid, and late) were calculated and analyzed.HT2, with a lower E/A ratio and left ventricular ejection fraction (LVEF), had a larger left atrium diameter (LAD) compared with those of the control group and HT1 (P < .05). Compared with the control group, the vortex size and strength, intraventricular pressure gradient during early and mid-diastole were higher in HT1 and lower in HT2 (P < .05). And in late diastole, the vortex size and strength, intraventricular pressure gradient of HT2 became higher than those of the control group (P < .05). Good correlation could be found between CE and E/A (P < .05), CM and ΔPM (P < .01), CL and FT3 (P < .05).VFM is proven practical for detecting the relationship between the changes of left ventricular diastolic vortex and the abnormal left ventricular filling.


Asunto(s)
Diástole/fisiología , Hipertiroidismo/complicaciones , Hipertiroidismo/fisiopatología , Disfunción Ventricular Izquierda/complicaciones , Disfunción Ventricular Izquierda/fisiopatología , Adolescente , Adulto , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ecocardiografía , Femenino , Hemodinámica , Humanos , Hipertiroidismo/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto Joven
13.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-333467

RESUMEN

Accurate prenatal diagnosis of complex congenital cardiovascular anomalies,vascular ones in particular,is still challenging.A fetal cardiovascular cast model can provide a copy of the cardiac chambers and great vessels with normal or pathological structures.This study was aimed to demonstrate three-dimensional anatomy of complex congenital cardiovascular anomalies in fetuses by means of corrosion casting.Twenty fetuses with prenatal-ultrasound-diagnosed complex cardiovascular anomalies were enrolled in this study (19 to 35 gestational weeks).Fetal cardiovascular cast models were made by a corrosion casting technique.The specimens were injected with casting material via the umbilical vein,and then immersed in strong acid after casting fluid was solidified,to disclose the geometries of cardiovascular cavities.Nineteen cast models were successfully made from 20 specimens.The casts distinctly showed the morphological malformations and spatial relationship between cardiac chambers and great vessels.One hundred and eleven abnormalities were revealed by casting in the 19 specimens,including 34 abnormalities located in the cardiac chambers (3,4 and 27 anomalies in the atria,atrioventricular valves and ventricles,respectively),and 77 in the great vessels (28,20,24 and 5 anomalies in the aorta and its branches,the pulmonary artery,the ductus arteriosus and the major veins,respectively).Corrosion casting can display three-dimensional anatomy of fetal complex cardiovascular anomalies.This improves our understanding of related pathomorphology and prenatal diagnosis.

14.
Artículo en Chino | WPRIM (Pacífico Occidental) | ID: wpr-333426

RESUMEN

The intubation of conventional transesophageal echocardiography (TEE) probes into patients causes serious esophagus irritation,and thus the use of TEE probes in pediatric practice is limited.In this study,we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience.During the examination,the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit (ICU),resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment.Two years ago,Prof.Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space.Later,Prof.Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect (ASD) patients and proved the safety and reliability of this method,which could become a new way for clinical diagnosis and treatment.

15.
J Huazhong Univ Sci Technolog Med Sci ; 36(3): 434-441, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27376817

RESUMEN

The present study investigated the application of echocardiography to evaluation of cardiac dyssynchrony in patients with congestive heart failure (CHF). A total of 348 consecutive CHF patients who were admitted for cardiac resynchronization (CRT) and presented with low ejection fraction (EF) and wide QRS duration were enrolled in this study, along with 388 healthy individuals. Dyssynchrony was assessed based on filling time ratio (FT/RR), left ventricular pre-ejection delay (PED), interventricular mechanical delay (IVMD), longitudinal opposing wall delay (LOWD) and radial septal to posterior wall delay (RSPWD). Response to CRT was defined as a ≥15% increase in EF. The results showed that FT/RR was decreased while PED, IVMD, LOWD and RSPWD were increased in the CHF group compared with the control group (P<0.01). In the CHF group, FT/RR was negatively correlated with the QRS duration, LV end-diastolic diameter (LVESd), LV end-diastolic volume (LVEDV) and LV end-systolic volume (LVESV) (P<0.01), but positively with the LVEF (P<0.01). Additionally, PED, IVMD, LOWD and RSPWD were positively correlated with the QRS duration, LVESd, LVEDV and LVESV (P<0.01), but negatively with the LVEF (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of LVEF. FT/RR decreased successively from the LVEF-1 group to the LVEF-2 group to the LVEF-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). The CHF group was divided into three subgroups according to the varying degrees of QRS duration, and FT/RR decreased successively in a sequence from the QRS-1 group to the QRS-2 group to the QRS-3 group, while the PED, IVMD, LOWD and RSPWD successively increased in the same order (P<0.01). Speckle tracking radial dyssynchrony ≥130 ms was predictive of an EF response in patients in QRS-1 group (78% sensitivity, 83% specificity), those in QRS-2 group (83% sensitivity, 77% specificity) and in QRS-3 group (89% sensitivity, 79% specificity). In conclusion, echocardiography is a convenient and sensitive method for evaluating cardiac dyssynchrony in patients with CHF.


Asunto(s)
Arritmias Cardíacas/diagnóstico por imagen , Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Corazón/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico por imagen , Adulto , Anciano , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Estudios de Casos y Controles , Diástole , Ecocardiografía , Femenino , Corazón/fisiopatología , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Sístole , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Remodelación Ventricular
16.
J Huazhong Univ Sci Technolog Med Sci ; 36(2): 259-264, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27072973

RESUMEN

To investigate the application and effectiveness of vascular corrosion technique in preparing fetal cardiovascular cast models, 10 normal fetal heart specimens with other congenital disease (control group) and 18 specimens with severe congenital heart disease (case group) from induced abortions were enrolled in this study from March 2013 to June 2015 in our hospital. Cast models were prepared by injecting casting material into vascular lumen to demonstrate real geometries of fetal cardiovascular system. Casting effectiveness was analyzed in terms of local anatomic structures and different anatomical levels (including overall level, atrioventricular and great vascular system, left-sided and right-sided heart), as well as different trimesters of pregnancy. In our study, all specimens were successfully casted. Casting effectiveness analysis of local anatomic structures showed a mean score from 1.90±1.45 to 3.60±0.52, without significant differences between case and control groups in most local anatomic structures except left ventricle, which had a higher score in control group (P=0.027). Inter-group comparison of casting effectiveness in different anatomical levels showed no significant differences between the two groups. Intra-group comparison also revealed undifferentiated casting effectiveness between atrioventricular and great vascular system, or left-sided and right-sided heart in corresponding group. Third-trimester group had a significantly higher perfusion score in great vascular system than second-trimester group (P=0.046), while the other anatomical levels displayed no such difference. Vascular corrosion technique can be successfully used in fabrication of fetal cardiovascular cast model. It is also a reliable method to demonstrate three-dimensional anatomy of severe congenital heart disease and normal heart in fetus.


Asunto(s)
Molde por Corrosión/métodos , Corazón Fetal/patología , Cardiopatías Congénitas/patología , Modelos Anatómicos , Humanos
17.
J Huazhong Univ Sci Technolog Med Sci ; 35(4): 574-578, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26223930

RESUMEN

Intraventricular hydrodynamics is considered an important component of cardiac function assessment. Vector flow mapping (VFM) is a novel flow visualization method to describe cardiac pathophysiological condition. This study examined use of new VFM and flow field for assessment of left ventricular (LV) systolic hemodynamics in patients with simple hyperthyroidism (HT). Thirty-seven simple HT patients were enrolled as HT group, and 38 gender- and age-matched healthy volunteers as control group. VFM model was used to analyze LV flow field at LV apical long-axis view. The following flow parameters were measured, including peak systolic velocity (Vs), peak systolic flow (Fs), total systolic negative flow (SQ) in LV basal, middle and apical level, velocity gradient from the apex to the aortic valve (ΔV), and velocity according to half distance (V1/2). The velocity vector in the LV cavity, stream line and vortex distribution in the two groups were observed. The results showed that there were no significant differences in the conventional parameters such as left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD) and left atrium diameter (LAD) between HT group and control group (P>0.05). Compared with the control group, a brighter flow and more vortexes were detected in HT group. Non-uniform distribution occurred in the LV flow field, and the stream lines were discontinuous in HT group. The values of Vs and Fs in three levels, SQ in middle and basal levels, ΔV and V1/2 were higher in HT group than in control group (P<0.01). ΔV was positively correlated with serum free thyroxin (FT4) (r=0.48, P<0.01). Stepwise multiple regression analysis showed that LVEDD, FT4, and body surface area (BSA) were the influence factors of ΔV. The unstable left ventricular systolic hydrodynamics increased in a compensatory manner in simple HT patients. The present study indicated that VFM may be used for early detection of abnormal ventricle contraction in clinical settings.


Asunto(s)
Ecocardiografía Doppler en Color/métodos , Hipertiroidismo/diagnóstico por imagen , Disfunción Ventricular Izquierda/diagnóstico , Adulto , Femenino , Humanos , Hipertiroidismo/complicaciones , Hipertiroidismo/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Disfunción Ventricular Izquierda/fisiopatología , Función Ventricular Izquierda , Adulto Joven
18.
J Huazhong Univ Sci Technolog Med Sci ; 35(4): 579-584, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26223931

RESUMEN

This study aimed to examine the optimal conditions of laser-induced interstitial thermotherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultrasonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2-4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 min, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation crater/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy revealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and congestion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effectively guide and assess the treatment.


Asunto(s)
Neoplasias Óseas/terapia , Terapia por Láser/instrumentación , Hepatopatías/terapia , Terapia por Ultrasonido/métodos , Animales , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/patología , Bovinos , Miembro Posterior/patología , Terapia por Láser/métodos , Hepatopatías/diagnóstico por imagen , Conejos , Resultado del Tratamiento , Terapia por Ultrasonido/instrumentación , Ultrasonografía
19.
Echocardiography ; 31(7): E218-21, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24814222

RESUMEN

Conjoined twins (CT) are rare with possible serious malformations in which soft tissue, bone, or some organs are joined in utero. The extent of cardiac fusion and intracardiac anatomy of CT determine the viability, natural history, and outcome of potential surgical intervention. Early prenatal diagnosis and assessment may provide a window of opportunity to counsel the family for their informed decision on the pregnancy and to plan for prenatal and perinatal care. In this report, we describe a case of thoracopagus twins diagnosed by fetal echocardiography at 23-week gestation. The 2 hearts fused at the atrial and ventricular levels. The outcome and review of literature on fetal echocardiographic characteristics of this malformation are discussed.


Asunto(s)
Corazón Fetal/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Gemelos Siameses , Ultrasonografía Prenatal/métodos , Aborto Eugénico , Adulto , Femenino , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Embarazo
20.
Int J Cardiol ; 173(1): 33-9, 2014 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-24594256

RESUMEN

OBJECTIVE: To evaluate the value of echocardiography in the diagnosis of different pathological patterns of sinus of Valsalva aneurysms (SVAs). METHODS: Echocardiographic features and surgical findings of 212 consecutive patients with SVAs treated in the last 17 years (1995-2012) at the Union Hospital of Huazhong University of Science and Technology were compared and analyzed retrospectively. RESULTS: 212 Chinese patients with SVAs underwent surgical repairs from January 1995 to May 2012 in our hospital. The aneurysms originated from the right, non-, multiple and left coronary sinus in 77.8%, 19.3%, 2.4% and 0.5%, respectively. 71.7% were ruptured, most commonly into the right ventricle (67.9%) followed by the right atrium (27.4%). Other rare entry sites of rupture included the left atrium, the left ventricle, the interatrial septum, the interventricular septum and the pulmonary artery (0.5%-1.9%). 164 SVAs arising from the right coronary sinus were classified by the Sakakibara method: 47.6% type I, 33.5% type II, 6.1% type IIIv and 12.8% type IIIa. 41 aneurysms of the non-coronary sinus were classified by the Guo method: 61.0% type I, 34.1% type IIa and 4.9% type IIv. The three most common associated cardiovascular lesions were ventricular septal defect (VSD) (53.3%), stenosis of right ventricular outflow tract (RVOTS) (7.5%) and aortic valvular malformations (5.2%). Compared with surgical results, the sensitivity, specificity and accuracy of echocardiographic diagnosis of SVAs were 93.9%, 99.9% and 99.8%, respectively. Of the 13 SVAs that were missed on echocardiography, 77% were small aneurysms of the right coronary sinus extending into the right ventricle across a VSD. Of the 199 cases diagnosed by echocardiography prior to surgery, the diagnostic accuracy of aneurismal origination, termination and whether ruptured or not was 99.0%, 99.0% and 97.5%, respectively. Echocardiography also diagnosed accurately all of the complications of the SVAs with the exception of aneurismal vegetations. The sensitivity, specificity and accuracy of echocardiography in diagnosing the associated cardiovascular lesions were 89.2%, 99.9% and 99.0%, respectively. The most common misdiagnosis and misdiagnosed associated lesions were the RVOTS and the types of VSD, respectively. CONCLUSIONS: Echocardiography has a specific value in the diagnosis of different pathological patterns of the SVAs with distinguishing ultrasonic features. To the best of our knowledge, this is the largest series of patients with SVAs surgically treated in a single medical center.


Asunto(s)
Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/cirugía , Seno Aórtico/diagnóstico por imagen , Seno Aórtico/cirugía , Adolescente , Adulto , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/epidemiología , Aneurisma de la Aorta/cirugía , Rotura de la Aorta/epidemiología , Niño , Preescolar , China/epidemiología , Ecocardiografía/métodos , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...