Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
ACS Appl Bio Mater ; 6(12): 5252-5263, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37955977

RESUMEN

The surface modification of biologically active factors on tissue-engineering vascular scaffold fails to fulfill the mechanical property and bioactive compounds' sustained release in vivo and results in the inhibition of tissue regeneration of small-diameter vascular grafts in vascular replacement therapies. In this study, biodegradable poly(ε-caprolactone) (PCL) was applied for scaffold preparation, and poly(ethylene glycol) (PG) hydrogel was used to load heparin and hepatocyte growth factor (HGF). In vitro analysis demonstrated that the PCL scaffold could inhibit the heparin release from the PG hydrogel, and the PG hydrogel could inhibit heparin release during the process of PCL degradation. Finally, it results in sustained release of HGF and heparin from the PCL-PG-HGF scaffold. The mechanical property of this hybrid scaffold improved after being coated with the PG hydrogel. In addition, the PCL-PG-HGF scaffold illustrated no inflammatory lesions, organ damage, or biological toxicity in all primary organs, with rapid organization of the endothelial cell layer, smooth muscle regeneration, and extracellular matrix formation. These results indicated that the PCL-PG-HGF scaffold is biocompatible and provides a microenvironment in which a tissue-engineered vascular graft with anticoagulant properties allows regeneration of vascular tissue (Scheme 1). Such findings confirm the feasibility of creating hydrogel scaffolds coated with bioactive factors to prepare novel vascular grafts.


Asunto(s)
Materiales Biocompatibles , Factor de Crecimiento de Hepatocito , Factor de Crecimiento de Hepatocito/farmacología , Preparaciones de Acción Retardada/farmacología , Materiales Biocompatibles/farmacología , Polietilenglicoles/farmacología , Hidrogeles/farmacología , Heparina/farmacología
2.
Biomater Adv ; 142: 213138, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36219919

RESUMEN

Tissue engineering is thought to the most promising strategy to develop successful small diameter vascular grafts (SDVG) to meet clinical demand. The introduction of natural substances into the SDVG made from synthetic biomaterials can improve the biocompatibility to promote the regeneration of SDVG in vivo. Due to that natural materials from different sources may have property deviation, it is vital to determine the source of natural materials to optimize SDVG fabrication for tissue engineering applications. In this study, bioactive SDVGs were prepared via coating of heparin-modified poly-(ε-caprolactone) scaffolds with a precursor solution containing vascular extracellular matrix (VECM) components and subsequent in situ gelation. The mechanical properties, degradation behaviors, and morphologies of the SDVGs were thoroughly characterized and evaluated. Cell experiments demonstrated the in vitro tissue specificity of the VECM that could promote the proliferation of endothelial cells better than skin-derived collagen. Furthermore, three types of SDVGs, SDVGs with blank hydrogel, SDVGs with skin-derived collagen, and SDVGs with vascular extracellular matrix (VECM-SDVGs), were implanted into the abdominal aorta of rats for one month. The explanted SDVGs were then comprehensively evaluated using hematoxylin and eosin, Masson, von Kossa staining, and immunohistochemical staining for CD31, α-SMA, and MHC. The results showed that the VECM-SDVGs showed the best endothelium regeneration, appropriate intima regeneration, and no calcification, indicating the in vivo specificity of the fabricated VECM-SDVGs. Thus, long-term implantation of VECM-SDVGs was performed. The results showed that a complete endothelial layer formed after 6 months of implantation, and the amount of contractile SMCs in the regenerative smooth muscle layer approached the amount of native aorta at the 12th month. Consequently, relying on vascular tissue specificity, VECM-SDVGs can modulate the regenerative behavior of the implanted SDVGs in vivo to achieve satisfactory vascular regeneration both in short- and long-term implantation.


Asunto(s)
Hidrogeles , Ingeniería de Tejidos , Ratas , Animales , Ingeniería de Tejidos/métodos , Células Endoteliales , Poliésteres/química , Matriz Extracelular , Colágeno
3.
J Mater Sci Mater Med ; 33(10): 67, 2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-36178545

RESUMEN

There are no suitable methods to develop the small-calibre tissue-engineered blood vessels (TEBVs) that can be widely used in the clinic. In this study, we developed a new method that combines electrospinning and in-body tissue architecture(iBTA) to develop small-calibre TEBVs. Electrospinning imparted mechanical properties to the TEBVs, and the iBTA imparted biological properties to the TEBVs. The hybrid fibres of PLCL (poly(L-lactic-co-ε-caprolactone) and PU (Polyurethane) were obtained by electrospinning, and the fibre scaffolds were then implanted subcutaneously in the abdominal area of the rabbit (as an in vivo bioreactor). The biotubes were harvested after four weeks. The mechanical properties of the biotubes were most similar to those of the native rabbit aorta. Biotubes and the PLCL/PU vascular scaffolds were implanted into the rabbit carotid artery. The biotube exhibited a better patency rate and certain remodelling ability in the rabbit model, which indicated the potential use of this hybridization method to develop small-calibre TEBVs. Sketch map of developing the biotube. The vascular scaffolds were prepared by electrospinning (A). Silicone tube was used as the core, and the vascular scaffold was used as the shell (B). The vascular scaffold and silicone tube were implanted subcutaneously in the abdominal area of the rabbit (C). The biotube was extruded from the silicone tube after 4 weeks ofembedding (D). The biotube was implanted for the rabbit carotid artery (E).


Asunto(s)
Poliuretanos , Ingeniería de Tejidos , Animales , Autoinjertos , Prótesis Vascular , Prótesis e Implantes , Conejos , Siliconas , Ingeniería de Tejidos/métodos , Andamios del Tejido
4.
Biomater Sci ; 10(15): 4257-4270, 2022 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-35766246

RESUMEN

As thermoplastic polyurethane (TPU) elastomers possess good biocompatibility and mechanical properties similar to those of native vascular tissues, they were intended to be co-electrospun with poly(ε-caprolactone) (PCL) onto the outer surface of PCL electrospun small-diameter single-layer vascular grafts (SLVGs) in this study, combining with surface heparinization. In this work, a kind of structurally reinforced TPU+PCL/PCL small-diameter bilayer vascular graft (BLVG) was fabricated via layer-by-layer electrospinning followed by the heparinization of PCL via EDC/NHS chemistry. The resulting (TPU+PCL/PCL)-Hep BLVGs presented excellent mechanical strength and higher compliance, and sustainably released heparin exhibited enhanced anti-coagulation activity. During 6-month implantation in 18 rat abdominal aortas, these vascular prostheses induced the remodeling and regeneration of neovascular tissues, and promoted ECM deposition. Compared to heparinized PCL (PCL-Hep) SLVGs, the formation of aneurysm was completely inhibited and the onset of calcification was significantly delayed in (TPU+PCL/PCL)-Hep BLVGs. Not only vascular cell makers co-expressed by CD206+ cells were identified, but also a high content of elastin was evidenced due to the improvement of mechanical strength and compliance. These results indicated the feasibility and efficacy of inhibiting the aneurysm formation and boosting the vascular remodeling by incorporating TPU into PCL-Hep small-diameter artificial vascular grafts.


Asunto(s)
Prótesis Vascular , Poliuretanos , Animales , Aorta Abdominal/cirugía , Poliésteres/química , Poliuretanos/química , Ratas , Andamios del Tejido/química
5.
Biomater Adv ; 133: 112628, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35527159

RESUMEN

Increasingly growing problems in vascular access for long-term hemodialysis lead to a considerable demand for synthetic small diameter vascular prostheses, which usually suffer from some drawbacks and are associated to high failure rates. Incorporating the concept of in situ tissue engineering (TE) into synthetic small diameter blood vessels, for example, thermoplastic poly(ether urethane) (TPU) ones, could provide an alternative approach for vascular access that profits from the advantages of excellent mechanical properties of synthetic polymer materials (early cannulation) and unique biointegration regeneration of autologous neovascular tissues (long-term fistulae). In this study, a kind of heparinized small diameter (d = 2.5 mm) TPU/poly(ε-caprolactone) (TPU/PCL-Hep) bi-layered blood vessels was electrospun with an inner layer of PCL and an outer layer of TPU. Afterward, the inner surface heparinization was conducted by coupling H2N-PEG-NH2 to the corroded PCL layer and then heparin to the attached H2N-PEG-NH2 via the EDCI/NHS chemistry. Herein a heparinized PCL inner layer could not only inhibit thrombosis, but also provide sufficient space for the neotissue regeneration via biodegradation with time. Meanwhile, a TPU outer layer could confer the vascular access the good mechanical properties, such as flexibility, viability and fitness of elasticity between the grafts and host blood vessels as evidenced by the adequate mechanical properties, such as compliance (4.43 ± 0.07%/ 100 mmHg), burst pressure (1447 ± 127 mmHg) and suture retention strength (1.26 ± 0.07 N) without blood seepage after implantation. Furthermore, a rabbit carotid aortic replacement model for 5 months was demonstrated 100% animal survival and 86% graft patency. Puncture assay also revealed the puncture resistance and self-sealing (hemostatic time < 2 min). Histological analysis highlighted neotissue regeneration, host cell infiltration and graft remodeling in terms of extracellular matrix turnover. Altogether, these results showed promising aspects of small diameter TPU/PCL-Hep bi-layered grafts for hemodialytic vascular access applications.


Asunto(s)
Sustitutos Sanguíneos , Andamios del Tejido , Animales , Arterias Carótidas/cirugía , Poliésteres/química , Conejos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
6.
Bioengineered ; 13(3): 7925-7938, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35358008

RESUMEN

A completely confluent endothelial cell (EC) monolayer is required to maintain proper vascular function in small diameter tissue-engineered vascular graft (TEVG). However, the most effective method for EC attachment to the luminal surface and formation of an entire endothelium layer that works in vitro remains a complicated challenge that requires urgent resolution. Although pulsatile flow has been shown to be better suited for the generation of functional endothelium, the optimal frequency setting is unknown. Several pulsatile flow frequencies were used to implant rat bone mesenchymal stem cells (MSC) into the lumen of decellularized porcine carotid arteries. The endothelium's integrity and cell activity were investigated in order to determine the best pulse frequency settings. The results showed that MSC were maximally preserved and exhibited maximal morphological changes with improved endothelialization performance in response to increased pulse stimulation frequency. Increased pulse frequency stimulation stimulates the expression of mechanoreceptor markers, cytoskeleton reorganization in the direction of blood flow, denser skeletal proteins fibronectin, and stronger intercellular connections when compared to constant pulse frequency stimulation. MSC eventually develops an intact endothelial layer with anti-thrombotic properties on the inner wall of the decellularized tubular lumen. Conclusion: The decellularized vessels retain the three-dimensional structure of the vasculature, have a surface topography suitable for MSC growth, and have good mechanical properties. By increasing the frequency of pulsed stimulation, MSC endothelialize the lumen of the decellularized vasculature. It is expected to have anti-thrombotic and anti-neointimal hyperplasia properties after implantation, ultimately improving the patency of TEVG.


Asunto(s)
Prótesis Vascular , Células Madre Mesenquimatosas , Animales , Reactores Biológicos , Células Endoteliales , Ratas , Estrés Mecánico , Porcinos , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
7.
J Biomater Sci Polym Ed ; 32(9): 1161-1181, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33830866

RESUMEN

Rapid endothelialization is crucial for in situ tissue engineering vascular grafts to prevent graft failure in the long-term. Gelatin is a promising nature material that can promote endothelial cells (ECs) adhesion, proliferation, and migration. In this study, the internal surface of electrospun polycaprolactone (PCL) vascular grafts was coated with gelatin. Endothelialization and vascular wall remolding were investigated by imaging and histological studies in the rat abdominal aorta replacement model. The endothelialization of heparinized gelatin-coated PCL (GP-H) vascular grafts was more rapid and complete than heparinized PCL (P-H) grafts. Intimal hyperplasia was milder in the GP-H vascular grafts than the P-H vascular grafts in the long-term. Meanwhile, smooth muscle cells (SMCs) and extracellular matrix (ECM) regeneration were better in the GP-H vascular grafts. By comparison, an aneurysm was observed in the P-H group in 6 months. Calcification was observed in both groups. All vascular grafts were patient after implantation in both groups. Our results showed that gelatin coating on the internal surface of PCL grafts is a simple and effective way to promote endothelialization. A more rapid endothelialization and complete endothelium can inhibit intimal hyperplasia in the long-term.


Asunto(s)
Células Endoteliales , Gelatina , Animales , Prótesis Vascular , Humanos , Poliésteres , Ratas
8.
Int J Artif Organs ; 44(7): 497-508, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33222583

RESUMEN

BACKGROUND: The decellularized scaffold is a promising material for producing tissue-engineered vascular grafts (TEVGs) because of its complex, native-like three-dimensional structure and mechanical properties. Sodium dodecyl sulfate (SDS), one of the most commonly used decellularization reagents, appears to be more effective than other detergents for removing cells from dense tissues. The concentrations of SDS used in previous studies and their effects on decellularization are not consistent. METHODS: In this study, porcine carotid arteries were decellularized using detergent-based protocols using Triton X-100 followed by SDS at different concentrations and exposing time. Cell removal efficiency and composition were evaluated by histological analysis, and DNA and collagen quantification. Ultrastructure, mechanical properties, pore size distribution, and in vivo biocompatibility of decellularized arteries were also evaluated. RESULTS: The DNA content of decellularized scaffolds treated with 0.3% SDS for 72 h or 0.5% SDS for 48 h was significantly less than that treated with 1% SDS for 30 h. There was a significant loss of soluble collagen after treatment with 1% SDS relative to native arteries. The extensive loss of elastin and glycosaminoglycans was observed in decellularized arteries treated with 0.5% SDS or 1% SDS. The basement membrane and biomechanics were also damaged by these two protocols. Moreover, decellularized scaffolds became more porous with many large pores after treatment with 0.3% SDS. CONCLUSION: Low-concentration SDS could be a suitable choice for artery decellularization. Decellularized porcine carotid arteries, prepared using Triton X-100 followed by 0.3% SDS, may be a promising biological scaffold for TEVGs.


Asunto(s)
Matriz Extracelular , Ingeniería de Tejidos , Animales , Arterias Carótidas , Detergentes , Dodecil Sulfato de Sodio , Porcinos , Andamios del Tejido
9.
Int J Cardiol ; 318: 39-42, 2020 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-32598994

RESUMEN

OBJECTIVE: The purpose of this study was to determine the trends in patient numbers, procedures numbers, amputation rate, length of stay (LOS) and hospitalization expenses in a National Clinical Research Center for Geriatric Disorders over 17 years (2002-2018). METHODS: The data of inpatients with chronic lower extremity ischemia caused by atherosclerosis in Xuanwu Hospital from 2002 to 2018 was reviewed. RESULTS: 5137 patients were reviewed, of whom 58% (2976/5137) were diabetic. The numbers of annual inpatients, endovascular treatment cases, and mean hospitalization expenses increased over time, and the mean LOS progressively decreased. The amputation rate decreased from 8.12% in 2002 to 2007 to 0.87% in 2008 to 2018 (P < .0001). The mean LOS decreased from 28.20 days in 2002 to 2007 to 11.12 days in 2008 to 2018 (P < .0001). The mean hospitalization expenses rose from 54,466.94 yuan in 2002 to 2007 to 76,469.40 yuan in 2008-2018 (p = .0013). There were no significant differences in mean LOS and mean hospitalization expenses between the diabetic and the non-diabetic groups. In the diabetic subgroup, the amputation rate decreased from 8.83% in 2002 to 2007 into 0.99% in 2008 to 2018 (P < .0001). CONCLUSION: From 2002 to 2018, the number of inpatients with atherosclerotic chronic lower limb ischemia increased gradually, and the number of endovascular treatments increased significantly; concomitantly, the amputation rate and mean LOS decreased, and the mean hospitalization expenses increased. The decreased amputation rate may be related to increased implementation of endovascular treatment or angiogenesis therapy.


Asunto(s)
Procedimientos Endovasculares , Recuperación del Miembro , Anciano , Amputación Quirúrgica , China/epidemiología , Humanos , Isquemia/diagnóstico , Isquemia/epidemiología , Isquemia/cirugía , Extremidad Inferior/cirugía , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
10.
Cell Tissue Bank ; 20(4): 569-578, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31606766

RESUMEN

Tissue engineering vascular grafts (TEVGs) have the potential to replace small-diameter grafts in bypass surgery which is good news for patients with cardiovascular disease. Decellularized arteries can be ideal TEVGs because their natural three-dimensional structures support the migration of host cells and vascular remodeling. There are many methods for decellularization without a standard protocol. In this study, a combination of Triton X-100 and sodium dodecyl sulfate (SDS) were used to prepare decellularized arteries. However, decellularization may damage the biochemical and mechanical properties to some degree. We used the cross-linking agents N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to improve mechanical properties and immobilize heparin to inhibit thrombogenesis. Histological analysis, scanning electron microscopy, biomechanical properties test, determination of immobilized heparin, active partial thrombin time assay, and subcutaneous embedding experiment were used to evaluate the efficiency of decellularization and the efficacy of heparinized cross-linked vascular scaffold. Results showed 1% Triton X-100 combined with 0.3% SDS can decellularize successfully. EDC and NHS cross-linking can improve the mechanical properties, reduce the inflammatory reaction and slow the degradation time. Heparin immobilized on the scaffolds can inhibit thrombogenesis effectively. This study indicated the heparinized cross-linked vascular scaffolds may be ideal scaffolds for TEVGs.


Asunto(s)
Anticoagulantes/química , Prótesis Vascular , Arterias Carótidas/ultraestructura , Heparina/química , Andamios del Tejido/química , Animales , Arterias Carótidas/química , Arterias Carótidas/citología , Reactivos de Enlaces Cruzados/química , Ratas Wistar , Succinimidas/química , Porcinos , Ingeniería de Tejidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...