Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 32(1): 551-575, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38175082

RESUMEN

Silicon photonic ring resonator thermometers have been shown to provide temperature measurements with a 10 mK accuracy. In this work we identify and quantify the intrinsic on-chip impairments that may limit further improvement in temperature measurement accuracy. The impairments arise from optically induced changes in the waveguide effective index, and from back-reflections and scattering at defects and interfaces inside the ring cavity and along the path between light source and detector. These impairments are characterized for 220 × 500 nm Si waveguide rings by experimental measurement in a calibrated temperature bath and by phenomenological models of ring response. At different optical power levels both positive and negative light induced resonance shifts are observed. For a ring with L = 100 µm cavity length, the self-heating induced resonance red shift can alter the temperature reading by 200 mK at 1 mW incident power, while a small blue shift is observed below 100 µW. The effect of self-heating is shown to be effectively suppressed by choosing longer ring cavities. Scattering and back-reflections often produce split and distorted resonance line shapes. Although these distortions can vary with resonance order, they are almost completely invariant with temperature for a given resonance and do not lead to measurement errors in themselves. The effect of line shape distortions can largely be mitigated by tracking only selected resonance orders with negligible shape distortion, and by measuring the resonance minimum wavelength directly, rather than attempting to fit the entire resonance line shape. The results demonstrate the temperature error due to these impairments can be limited to below the 3 mK level through appropriate design choices and measurement procedures.

2.
Opt Lett ; 48(23): 6236-6239, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38039235

RESUMEN

Silicon photonic wavefront phase-tilt sensors for wavefront monitoring using surface coupling grating arrays are demonstrated. The first design employs the intrinsic angle dependence of the grating coupling efficiency to determine local wavefront tilt, with a measured sensitivity of 7 dB/°. The second design connects four gratings in an interferometric waveguide circuit to determine incident wavefront phase variation across the sensor area. In this device, one fringe spacing corresponds to 2° wavefront tilt change. These sensor elements sample a wavefront incident on the chip surface without the use of bulk optic elements, fiber arrays, or imaging arrays. Both sensor elements are less than 60 µm across and are potential unit cell sensor elements for large arrays that monitor wavefront shape across an image or pupil plane in adaptive optics systems for free-space optical communications, astronomy, and beam pointing applications.

3.
Zhonghua Yi Xue Za Zhi ; 103(8): 578-584, 2023 Feb 28.
Artículo en Chino | MEDLINE | ID: mdl-36822869

RESUMEN

Objective: To investigate the knowledge, use and barriers when prescribing GLP-1RA and SGLT2i among cardiologists, endocrinologists and general practitioners, and explore the influencing factors that hinder the use of these medications. Methods: A questionnaire was conducted among physicians in the above departments in Peking University Third Hospital and health service institutions at all levels in its medical consortium. A total of 342 physicians were involved. Among them, 40.6% (139) were cardiologists, 28.9% (99) were endocrinologists and 30.4% (104) were general practitioners; 66.7% (270) came from Beijing while 33.3% (72) from other provinces. The survey included clinicians' knowledge and current use of GLP-1RA and SGLT2i, and the possible reasons that influenced the prescription of these medications. Medical therapies of physicians were investigated by simulating different clinical scenarios. The difference of measures among physicians in different departments was compared. Results: A total of 342 physicians were involved, with the average age of 40 (35, 46) years old and the average working time of 13 (7, 20) years. Among them, 40.6% (139) were male. 77.5% (265) physicians had comprehensive knowledge of SGLT2i and prescribed it, which was higher than that for GLP-1RA (70.5%, 241) (P<0.001). 21.1% (72) physicians prescribed SGLT2i more than 20 times per month, which was higher than that for GLP-1RA (8.2%, 28) (P<0.001). Endocrinologists had more knowledge and prescribed more GLP-1RA and SGLT2i compared with other physicians (both P values<0.001). 38.1% (53) cardiologists, 22.2% (22) endocrinologists, and 30.8% (32) general practitioners believed patients needed an endocrinologist to evaluate and adjust GLP-1RA, which was the primary barrier for the use of medications (P=0.042). 27.4% (38) cardiologists, 14.1% (14) endocrinologists, and 30.8% (32) general practitioners believed patients needed an endocrinologist to evaluate and adjust SGLT2i, which was the primary barrier for the use of medications (P=0.018). 21.6% (30) cardiologists, 45.5% (45) endocrinologists, and 31.7% (33) general practitioners believed side effects of SGLT2i was the primary barrier for the use of medications (P<0.001). For patients with unqualified glycemic control and cardiovascular complications, 65.4% (75) cardiologists, 69.7% (69) endocrinologists, and 43.3% (45) general practitioners chose the above medications (P<0.001). For patients with qualified glycemic control, combined with cardiovascular complications and diabetic organ damage, 35.3% (49) cardiologists, 52.5% (52) endocrinologists, and 25.0% (26) general practitioners chose the above medications (P<0.001). Conclusions: Physicians had more knowledge and prescription of SGLT2i than that of GLP-1RA. Endocrinologists had more knowledge and prescription of the above medications than other physicians. The side effect of medications was potential primary barrier for the use of the novel hypoglycemic agent with cardiovascular benefits. In clinical practice, most of physicians considered that high-risk patients with cardiovascular comorbidities need to be referred to cardiologist or endocrinologist to adjust clinical therapies.


Asunto(s)
Sistema Cardiovascular , Diabetes Mellitus Tipo 2 , Cardiopatías , Médicos , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Hipoglucemiantes/uso terapéutico , Diabetes Mellitus Tipo 2/complicaciones , Mediastino , Cardiopatías/complicaciones
4.
Zhonghua Yi Xue Za Zhi ; 102(46): 3698-3703, 2022 Dec 13.
Artículo en Chino | MEDLINE | ID: mdl-36509542

RESUMEN

Objective: To explore the effect of "one-stop" outpatient management on the therapeutic schedule and control rate of patients with metabolic disorders. Methods: A total of 332 patients who met the inclusion criteria were enrolled and treated regularly in the "one-stop" outpatient department of the Department of Cardiology of the Third Hospital of Peking University from November 1, 2020 to April 30, 2022. The general information, personal history, family history, drug treatment plan, blood pressure, height, weight, waist circumference, and hip circumference of patients were collected through the outpatient electronic medical record system, and patients were followed up through conducting "one-stop" comprehensive management. The baseline clinical characteristics were analyzed, and the changes of metabolic indexes, treatment conditions and control rate of patients with different metabolic disorders before and after the "one-stop" outpatient management were compared. Results: The time interval between the first visit and the last visit was 44 (26, 60) weeks in 332 patients, whose age was (57.2±13.2) years, including 219 males (66.0%). After the "one-stop" outpatient management, fasting blood glucose (FBG) [ 6.6 (5.6, 7.9) mmol/L vs 6.3 (5.6, 6.9) mmol/L], glycosylated hemoglobin A1c (HbA1c) [ (7.2±1.5) % vs (6.6±0.8) %], low density lipoprotein cholesterol (LDL-C) [ 2.70 (1.97, 3.55) mmol/L vs 2.04 (1.66, 2.63) mmol/L] and blood uric acid (UA) [ (383.7±107.1) µmol/L vs (341.2±90.6) µmol/L] all decreased significantly (all P values<0.05). The control rates of hypertension (19.8% vs 28.2%), diabetes (45.2% vs 66.5%), hyperlipidemia (54.9% vs 87.6%) and hyperuricemia (16.7% vs 49.0%) were significantly improved after the "one-stop" outpatient management (all P values<0.05). Conclusion: The "one-stop" outpatient management of cardiovascular department can significantly improve the metabolic condition and the control rate of patients with multiple metabolic disorders.


Asunto(s)
Diabetes Mellitus , Hipertensión , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Hemoglobina Glucada , Circunferencia de la Cintura , Presión Sanguínea , Glucemia
5.
Zhonghua Yi Xue Za Zhi ; 101(17): 1210-1213, 2021 May 11.
Artículo en Chino | MEDLINE | ID: mdl-34865390

RESUMEN

Sepsis is a life-threatening multiple organ dysfunction syndrome caused by infection, and kidney is one of the most organs susceptible to injury in sepsis. Critical ill patients with sepsis often suffer from acute kidney injury (AKI) of varying degrees with a high mortality. There are more and more researches on the early identification, pathogenesis, diagnosis and treatment of acute kidney injury in sepsis. In order to improve the understanding and reduce the mortality of acute kidney injury, this review briefly discussed the early identification, physio-pathologic mechanism, treatment, prognosis and follow up.


Asunto(s)
Lesión Renal Aguda , Sepsis , Lesión Renal Aguda/etiología , Humanos , Riñón , Insuficiencia Multiorgánica , Pronóstico
6.
Eur Rev Med Pharmacol Sci ; 22(16): 5230-5239, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30178846

RESUMEN

OBJECTIVE: This study is designed to investigate the role of miR-363-3p in the cancer development of glioma. PATIENTS AND METHODS: The expression of miR-363-3p in glioma and adjacent noncancerous tissue was measured using quantitative RT-PCR. The expression of a target gene of miR-363-3p, pyruvate dehydrogenase B (PDHB), was determined by Western blot. The level of miR-363-3p was increased or decreased by transfected with miR-363-3p mimic or miR-363-3p inhibitor, respectively. The impact of miR-363-3p on cell growth, apoptosis and invasion was determined by CCK-8 (Cell Counting Kit) assay, flow cytometry, and transwell assay. The role of PDHB in mediating the oncogenic activities was demonstrated by co-transfected PDHB vector and miR-363-3p mimic. RESULTS: Our results have shown that miR-3663-3p level was significantly higher in glioma tissue. Furthermore, miR-363-3p functions as onco-miRNA, promotes cell proliferation, protects against apoptosis, and enhances invasion by directly targeting PDHB. CONCLUSIONS: MiR-363-3p is an onco-miRNA, which can be considered as a potential therapeutic target in glioma.


Asunto(s)
Neoplasias Encefálicas/metabolismo , Proliferación Celular/fisiología , Glioma/metabolismo , MicroARNs/biosíntesis , Complejo Piruvato Deshidrogenasa/metabolismo , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patología , Línea Celular Tumoral , Femenino , Glioma/genética , Glioma/patología , Humanos , MicroARNs/genética , Invasividad Neoplásica/genética , Invasividad Neoplásica/patología
7.
Opt Lett ; 39(18): 5351-4, 2014 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-26466269

RESUMEN

We propose a fiber-chip grating coupler that interleaves the standard full and shallow etch trenches in a 220 nm thick silicon layer to provide a directionality upward exceeding 95%. By adjusting the separation between the two sets of trenches, constructive interference is achieved in the upward direction independent of the bottom oxide thickness and without any bottom reflectors, overlays, or customized etch depths. We implement a transverse subwavelength structure in the first two grating periods to minimize back-reflections. The grating coupler has a calculated coupling efficiency of CE~-1.05 dB with a 1 dB bandwidth of 30 nm and minimum feature size of 100 nm, compatible with deep-UV lithography.

8.
Genet Mol Res ; 12(4): 5321-34, 2013 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-24301793

RESUMEN

Many developmental genes play important roles in regeneration. Here, we cloned the two developmental genes, Wnt6 and Hox6, from Apostichopus japonicus by rapid amplification of cDNA ends (RACE) polymerase chain reaction (PCR). The Wnt6 full-length cDNA is 1140 bp long with a 1029-bp open reading frame encoding 342 amino acids. The deduced Wnt6 protein contained a 22-amino acid signal peptide and a 274-amino acid mature peptide. The Hox6 (AjHBOX6) full-length cDNA contained 1312 bp with a 966-bp open reading frame encoding 321 amino acids. Its deduced amino acid sequence included one homeodomain (60 amino acids) and three domains with low compositional complexity. Comparison and phylogenetic analysis revealed that Wnt6 and Hox6 in A. japonicus had the nearest relationship to those in sea urchins. Further expression analysis by real-time PCR showed that Wnt6 and Hox6 were apparently upregulated during intestine regeneration, which suggested that they were involved in the intestinal regeneration of sea cucumbers.


Asunto(s)
Clonación Molecular , Expresión Génica , Proteínas de Homeodominio/genética , Intestinos/fisiología , Regeneración/genética , Pepinos de Mar/genética , Pepinos de Mar/metabolismo , Proteínas Wnt/genética , Secuencia de Aminoácidos , Animales , Secuencia de Bases , ADN Complementario/genética , Perfilación de la Expresión Génica , Datos de Secuencia Molecular , Filogenia , Alineación de Secuencia
9.
Opt Express ; 21(4): 4623-37, 2013 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-23481995

RESUMEN

A complete photonic wire molecular biosensor microarray chip architecture and supporting instrumentation is described. Chip layouts with 16 and 128 independent sensors have been fabricated and tested, where each sensor can provide an independent molecular binding curve. Each sensor is 50 µm in diameter, and consists of a millimeter long silicon photonic wire waveguide folded into a spiral ring resonator. An array of 128 sensors occupies a 2 × 2 mm2 area on a 6 × 9 mm2 chip. Microfluidic sample delivery channels are fabricated monolithically on the chip. The size and layout of the sensor array is fully compatible with commercial spotting tools designed to independently functionalize fluorescence based biochips. The sensor chips are interrogated using an instrument that delivers sample fluid to the chip and is capable of acquiring up to 128 optical sensor outputs simultaneously and in real time. Coupling light from the sensor chip is accomplished through arrays of sub-wavelength surface grating couplers, and the signals are collected by a fixed two-dimensional detector array. The chip and instrument are designed so that connection of the fluid delivery system and optical alignment are automated, and can be completed in a few seconds with no active user input. This microarray system is used to demonstrate a multiplexed assay for serotyping E. coli bacteria using serospecific polyclonal antibody probe molecules.


Asunto(s)
Técnicas Biosensibles/instrumentación , Escherichia coli/aislamiento & purificación , Fotometría/instrumentación , Serotipificación/instrumentación , Análisis de Matrices Tisulares/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo
10.
Opt Lett ; 37(17): 3534-6, 2012 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22940940

RESUMEN

Integrated polarization rotators are known to exhibit stringent fabrication tolerances, which severely handicap their practical application. Here we present a general polarization rotator scheme that enables both the compensation of fabrication errors and wavelength tunability. The scheme is described analytically, and a condition for perfect polarization conversion is established. Simulations of a silicon-on-insulator polarization rotator show polarization extinction ratios in excess of 40 dB even in the presence of large fabrication errors that in a conventional rotator configuration degrade the extinction ratio to below 5 dB. Additionally, wavelength tuning over ±30 nm is shown.

11.
Opt Express ; 20(12): 13470-7, 2012 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-22714374

RESUMEN

Directional couplers are extensively used devices in integrated optics, but suffer from limited operational wavelength range. Here we use, for the first time, the dispersive properties of sub-wavelength gratings to achieve a fivefold enhancement in the operation bandwidth of a silicon-on-insulator directional coupler. This approach does not compromise the size or the phase response of the device. The sub-wavelength grating based directional coupler we propose covers a 100 nm bandwidth with an imbalance of ≤ 0.6 dB between its outputs, as supported by full 3D FDTD simulations.

12.
Opt Express ; 19(23): 22410-6, 2011 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-22109117

RESUMEN

We demonstrate all-optical wavelength conversion at 10 Gb/s for differential phase-shift keyed (DPSK) data signals in the C-band, based on four-wave mixing (FWM) in a silicon ring resonator. Error-free operation with a system penalty of ~4.1 dB at 10⁻9 BER is achieved.

13.
Opt Express ; 19(21): 20364-71, 2011 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-21997046

RESUMEN

We demonstrate an all-optical XOR logic function for 40Gb/s differential phase-shift keyed (DPSK) data signals in the C-band, based on four-wave mixing (FWM) in a silicon nanowire. Error-free operation with a system penalty of ~3.0dB and ~4.3dB at 10⁻9 BER is achieved.

14.
Opt Lett ; 36(14): 2647-9, 2011 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-21765496

RESUMEN

Grating couplers are widely used as an efficient and versatile fiber-chip coupling structure in nanometric silicon wire waveguides. The implementation of efficient grating couplers in micrometric silicon-on-insulator (SOI) rib waveguides is, however, challenging, since the coupler waveguide region is multimode. Here we experimentally demonstrate grating couplers in 1.5 µm-thick SOI rib waveguides with a coupling efficiency of -2.2 dB and a 3 dB bandwidth of 40 nm. An inverse taper is used to adiabatically transform the interconnection waveguide mode to the optimum grating coupler excitation field with negligible higher order Bloch mode excitation. Couplers are fabricated in the same etch step as the waveguides using i-line stepper lithography. The benefits of wafer-scale testing and device characterization without facet preparation are thus attained at no additional cost.

15.
Opt Lett ; 36(11): 2110-2, 2011 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-21633465

RESUMEN

We demonstrate, by experiment and numerical calculations, temperature-independent subwavelength grating waveguides with a periodic composite core composed of alternating regions of silicon and SU-8 polymer. The polymer has a negative thermo-optic (TO) material coefficient that cancels the large positive TO effect of the silicon. Measurements and Bloch mode calculations were carried out over a range of silicon-polymer duty ratios. The lowest measured TO coefficient at a wavelength of 1550 nm is 1.8×10(-6) K(-1); 2 orders of magnitude smaller than a conventional silicon photonic wire waveguide. Calculations predict the possibility of complete cancellation of the silicon waveguide temperature dependence.

16.
Opt Express ; 18(22): 22867-79, 2010 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-21164626

RESUMEN

A comprehensive investigation of real-time temperature-induced resonance shift cancellation for silicon wire based biosensor arrays is reported for the first time. A reference resonator, protected by either a SU8 or SiO(2) cladding layer, is used to track temperature changes. The temperature dependence of resonators in aqueous solutions, pertinent to biosensing applications, is measured under steady-state conditions and the operating parameters influencing these properties are discussed. Real-time measurements show that the reference resonator resonances reflect the temperature changes without noticeable time delay, enabling effective cancellation of temperature-induced shifts. Binding between complementary IgG protein pairs is monitored over 4 orders of magnitude dynamic range down to a concentration of 20 pM, demonstrating a resolvable mass of 40 attograms. Reactions are measured over time periods as long as 3 hours with high stability, showing a scatter corresponding to a fluid refractive index fluctuation of ± 4 × 10(-6) in the baseline data. Sensor arrays with a SU8 protective cladding are easy to fabricate, while oxide cladding is found to provide superior stability for measurements involving long time scales.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Coloración y Etiquetado , Temperatura , Animales , Electricidad , Inmunoglobulina G/análisis , Conejos , Silicio/química , Dióxido de Silicio/química , Análisis Espectral , Factores de Tiempo
17.
Opt Lett ; 35(19): 3243-5, 2010 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-20890347

RESUMEN

We demonstrate a fully etched, continuously apodized fiber-to-chip surface grating coupler for the first time (to our knowledge). The device is fabricated in a single-etch step and operates with TM-polarized light, achieving a coupling efficiency of 3.7 dB and a 3 dB bandwidth of 60 nm. A subwavelength microstructure is employed to generate an effective medium engineered to vary the strength of the grating and thereby maximize coupling efficiency, while mitigating backreflections at the same time. Minimum feature size is 100 nm for compatibility with deep-UV 193 nm lithography.

18.
Opt Lett ; 35(16): 2771-3, 2010 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-20717452

RESUMEN

We report a silicon-on-insulator ring resonator biosensor array with one output port, using wavelength division multiplexing as the addressing scheme. With the use of on-chip referencing for environmental drift cancellation, simultaneous monitoring of multiplexed molecular bindings is demonstrated, with a resolution of 0.3 pg/mm(2) (40 ag of total mass) for protein concentrations over 4 orders of magnitude down to 20 pM. Reactions are measured over time periods as long as 3 h with high stability.


Asunto(s)
Técnicas Biosensibles/instrumentación , Silicio , Animales , Bovinos , Inmunoglobulina G/inmunología , Microtecnología , Albúmina Sérica Bovina/análisis , Albúmina Sérica Bovina/inmunología
19.
Opt Express ; 18(4): 3905-10, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-20389401

RESUMEN

We demonstrate all-optical time division demultiplexing from 160Gb/s to 10Gb/s in the C-band, based on four-wave mixing (FWM) in a silicon nanowire. We achieve error-free operation with a system penalty of approximately 3.9dB at 10(-9) BER.


Asunto(s)
Nanotubos/química , Dispositivos Ópticos , Silicio/química , Telecomunicaciones/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Microondas , Nanotubos/ultraestructura
20.
Opt Lett ; 34(23): 3598-600, 2009 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-19953132

RESUMEN

We demonstrate a silicon photonic wire waveguide biosensor array chip for the simultaneous monitoring of different molecular binding reactions. The chip is compatible with automated commercial spotting tools and contains a monolithically integrated microfluidic channel for sample delivery. Each array sensor element is a 1.8-mm-long spiral waveguide folded within a 130 microm diameter spot and is incorporated in a balanced Mach-Zehnder interferometer with a near temperature independent response. The sensors are arranged in a 400 microm spacing grid pattern and are addressed through cascaded 1x2 optical power splitters using light from a single input fiber. We demonstrate the real-time monitoring of antibody-antigen reactions using complementary and mismatched immunoglobulin G receptor-analyte pairs and bovine serum albumin. The measured level of detection for each sensor element corresponds to a surface coverage of less than 0.3 pg/mm(2).


Asunto(s)
Técnicas Biosensibles/instrumentación , Fotones , Silicio , Animales , Técnicas Biosensibles/métodos , Bovinos , Inmunoglobulina G/metabolismo , Análisis por Micromatrices , Microfluídica , Conejos , Albúmina Sérica Bovina/metabolismo , Coloración y Etiquetado , Integración de Sistemas , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...