Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 50(3): 881-891, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36301324

RESUMEN

PURPOSE: To compare PET/CT, MRI and ultrasonography in detecting recurrence of nasopharyngeal carcinoma and identify their benefit in staging, contouring and overall survival (OS). METHODS: Cohort A included 1453 patients with or without histopathology-confirmed local recurrence, while cohort B consisted of 316 patients with 606 histopathology-confirmed lymph nodes to compare the sensitivities and specificities of PET/CT, MRI and ultrasonography using McNemar test. Cohorts C and D consisted of 273 patients from cohort A and 267 patients from cohort B, respectively, to compare the distribution of PET/CT-based and MRI-based rT-stage and rN-stage and the accuracy of rN-stage using McNemar test. Cohort E included 30 random patients from cohort A to evaluate the changes in contouring with or without PET/CT by related-samples T test or Wilcoxon rank test. The OS of 61 rT3-4N0M0 patients staged by PET/CT plus MRI (cohort F) and 67 MRI-staged rT3-4N0M0 patients (cohort G) who underwent similar salvage treatment were compared by log-rank test and Cox regression. RESULTS: PET/CT had similar specificity to MRI but higher sensitivity (93.9% vs. 79.3%, P < 0.001) in detecting local recurrence. PET/CT, MRI and ultrasonography had comparable specificities, but PET/CT had greater sensitivity than MRI (90.9% vs. 67.6%, P < 0.001) and similar sensitivity to ultrasonography in diagnosing lymph nodes. According to PET/CT, more patients were staged rT3-4 (82.8% vs. 68.1%, P < 0.001) or rN + (89.9% vs. 69.3%, P < 0.001), and the rN-stage was more accurate (90.6% vs. 73.8%, P < 0.001). Accordingly, the contours of local recurrence were more precise (median Dice similarity coefficient 0.41 vs. 0.62, P < 0.001) when aided by PET/CT plus MRI. Patients staged by PET/CT plus MRI had a higher 3-year OS than patients staged by MRI alone (85.5% vs. 60.4%, P = 0.006; adjusted HR = 0.34, P = 0.005). CONCLUSION: PET/CT more accurately detected and staged recurrence of nasopharyngeal carcinoma and accordingly complemented MRI, providing benefit in contouring and OS.


Asunto(s)
Neoplasias Nasofaríngeas , Tomografía Computarizada por Tomografía de Emisión de Positrones , Humanos , Fluorodesoxiglucosa F18 , Carcinoma Nasofaríngeo/diagnóstico por imagen , Carcinoma Nasofaríngeo/terapia , Terapia Recuperativa , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/terapia , Recurrencia Local de Neoplasia/patología , Imagen por Resonancia Magnética , Sensibilidad y Especificidad , Neoplasias Nasofaríngeas/diagnóstico por imagen , Neoplasias Nasofaríngeas/terapia , Estadificación de Neoplasias
3.
J Med Radiat Sci ; 64(2): 106-113, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27741377

RESUMEN

INTRODUCTION: In intensity modulated radiotherapy (IMRT) of nasopharyngeal carcinoma (NPC) patients, an effective immobilisation system is important to minimise set up deviation. This study evaluated the effectiveness of three immobilisation systems by assessing their set up deviations. METHODS: Patients were randomly assigned to one of the three immobilisation systems: (1) supine on head rest and base plate (HB); (2) supine with alpha cradle supporting the head and shoulder (AC); (3) supine with vacuum bag supporting the head and shoulder (VB). CBCT was conducted weekly for each patient on the linear accelerator. Image registration was conducted at the nasopharynx (NP) and cervical regions. The translational displacements (latero-medial, antero-posterior and cranio-caudal), rotational displacements (pitch, yaw and roll) and 3D vectors obtained at the NP and cervical regions were recorded and compared among the three systems. RESULTS: The mean translational and rotational deviations were within 3 mm and 2°, respectively, and the range of 3D vector was 1.53-3.47 mm. At the NP region, the AC system demonstrated the smallest translational and rotational deviations and 3D vector. The differences were significant except for the latero-medial, yaw and roll directions. Similarly, at the cervical region, the AC system showed smaller translational and rotational deviations and 3D vector, with only the cranio-caudal and yaw deviations that did not reach statistical significance. CONCLUSIONS: Set up deviation was greater in the neck than the NP region. The set up accuracy of the AC system was better than the other two systems, and it is recommended for IMRT of NPC patients in our institution.


Asunto(s)
Carcinoma/radioterapia , Inmovilización/instrumentación , Neoplasias Nasofaríngeas/radioterapia , Planificación de la Radioterapia Asistida por Computador/instrumentación , Errores de Configuración en Radioterapia , Radioterapia de Intensidad Modulada/instrumentación , Adulto , Anciano , Carcinoma/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Carcinoma Nasofaríngeo , Neoplasias Nasofaríngeas/diagnóstico por imagen , Resultado del Tratamiento , Adulto Joven
4.
Biomed Res Int ; 2014: 326532, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25197637

RESUMEN

An approximate correction method for the CT value-electron density curve of CBCT was established, through comparison and fitting with FBCT images, and applied to evaluate the therapeutic dose of IMRT. The precision of using CBCT for plan calculation was validated by comparing the dose distribution between CBCT- and FBCT-based IMRT plans. Also setup deviations were simulated to evaluate the ability of the CBCT-based calculation for detecting the dose errors caused by positioning deviation. The gamma comparison between CBCT- and FBCT-based dose computations showed that the pass rates of (2%, 2 mm) criteria were better than 97.60 ± 0.83% and 97.74 ± 2.08% in the phantom and 10 NPC cases. When setup deviation was introduced into CBCT-based dose calculation, the gamma pass rate significantly decreased while the volumetric doses of the targets and some normal organs exhibited different changes compared to the original plan. Our results validated the above CT value-electron density correction which reduced the difference between CBCT- and FBCT-based IMRT plan calculation for NPC to less than 2%. Online CBCT-based dose calculation can be used to reflect and evaluate the dose distribution discrepancy caused by setup deviation and structure changes during the treatment, ensuring more effective quality control of IMRT treatment.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Cabeza/efectos de la radiación , Cuello/efectos de la radiación , Radioterapia de Intensidad Modulada , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Electrones , Humanos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...