1.
Heliyon ; 10(5): e27481, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38486728

RESUMEN

The reliability of MEMS inertial devices applied in complex environments involves interdisciplinary fields, such as structural mechanics, material mechanics and multi-physics field coupling. Nowadays, MEMS inertial devices are widely used in the fields of automotive industry, consumer electronics, aerospace and missile guidance, and a variety of reliability issues induced by complex environments arise subsequently. Hence, reliability analysis and design of MEMS inertial devices are becoming increasingly significant. Since the reliability issues of MEMS inertial devices are mainly caused by complex mechanical and thermal environments with intricate failure mechanisms, there are fewer reviews of related research in this field. Therefore, this paper provides an extensive review of the research on the reliability of typical failure modes and mechanisms in MEMS inertial devices under high temperature, temperature cycling, vibration, shock, and multi-physical field coupling environments in the last five to six years. It is found that though multiple studies exist examining the reliability of MEMS inertial devices under single stress, there is a dearth of research conducted under composite stress and a lack of systematic investigation. Through analyzing and summarizing the current research progress in reliability design, it is concluded that multi-physical field coupling simulation, theoretical modeling, composite stress experiments, and special test standards are important directions for future reliability research on MEMS inertial devices.

2.
Micromachines (Basel) ; 15(2)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38398935

RESUMEN

Impact is the most important factor affecting the reliability of Micro-Electro-Mechanical System (MEMS) gyroscopes, therefore corresponding reliability design is very essential. This paper proposes a shock-protected structure (SPS) capable of withstanding a full temperature range from -40 °C to 80 °C to enhance the shock resistance of MEMS gyroscopes. Firstly, the shock transfer functions of the gyroscope and the SPS are derived using Single Degree-of-Freedom and Two Degree-of-Freedom models. The U-folded beam stiffness and maximum positive stress are deduced to evaluate the shock resistance of the silicon beam. Subsequently, the frequency responses of acceleration of the gyroscope and the SPS are simulated and analyzed in Matlab utilizing the theoretical models. Simulation results demonstrate that when the first-order natural frequency of the SPS is approximately one-fourth of the gyroscope's resonant frequency, the impact protection effect is best, and the SPS does not affect the original performance of the gyroscope. The acceleration peak of the MEMS gyroscope is reduced by approximately 23.5 dB when equipped with the SPS in comparison to its counterpart without the SPS. The anti-shock capability of the gyroscope with the SPS is enhanced by approximately 13 times over the full-temperature range. After the shock tests under the worst case, the gyroscope without the SPS experiences a beam fracture failure, while the performance of the gyroscope with the SPS remains normal, validating the effectiveness of the SPS in improving the shock reliability of MEMS gyroscopes.

3.
Micromachines (Basel) ; 14(10)2023 Oct 20.
Artículo en Inglés | MEDLINE | ID: mdl-37893393

RESUMEN

MEMS gyroscopes are widely applied in consumer electronics, aerospace, missile guidance, and other fields. Reliable packaging is the foundation for ensuring the survivability and performance of the sensor in harsh environments, but gas leakage models of wafer-level MEMS gyroscopes are rarely reported. This paper proposes a gas leakage model for evaluating the packaging reliability of wafer-level MEMS gyroscopes. Based on thermodynamics and hydromechanics, the relationships between the quality factor, gas molecule number, and a quality factor degradation model are derived. The mechanism of the effect of gas leakage on the quality factor is explored at wafer-level packaging. The experimental results show that the reciprocal of the quality factor is exponentially related to gas leakage time, which is in accordance with the theoretical analysis. The coefficients of determination (R2) are all greater than 0.95 by fitting the curves in Matlab R2022b. The stable values of the quality factor for drive mode and sense mode are predicted to be 6609.4 and 1205.1, respectively, and the average degradation characteristic time is 435.84 h. The gas leakage time is at least eight times the average characteristic time, namely 3486.72 h, before a stable condition is achieved in the packaging chamber of the MEMS gyroscopes.

4.
Heliyon ; 9(3): e13269, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36950598

RESUMEN

Cancer/testis antigens (CTAs) are reproductive tissue-restricted genes, frequently ectopic expressed in tumors. CTA genes associate with a poor prognosis in some solid tumors, due to their potential roles in the tumorigenesis and progression. However, whether CTAs relate with hepatocellular carcinoma (HCC) remains unclear. In this study, the prognostic signatures based on CTA genes were investigated and validated in three cohorts including Chinese HCC patients with hepatitis B virus infection (CHCC-HBV), International Cancer Genome Consortium (ICGC) and The Cancer Genome Atlas (TCGA) cohorts. Univariate, LASSO, and multivariate Cox regression analyses were used to screen prognostic genes and develop the prognostic gene signature. A prognosis model was established with six CTA genes (SSX1, CTCFL, OIP5, CEP55, NOL4, and TPPP2) in CHCC-HBV cohort, and further validated in the ICGC and TCGA cohorts. The CTA signature was an essential prognostic predictor independent of other clinical pathological factors. High-risk group exhibited up-regulated cell cycle-related and tumor-related pathways and more M0 macrophage, activated mast cell, activated memory CD4+ T cell, and memory B cell infiltration. Furthermore, CTA signature correlated with the sensitivity to multiple chemotherapy drugs. Our results highlighted that the CTA gene profiling was a prognostic assessment tool for HCC patients.

5.
Gastroenterol Res Pract ; 2019: 6069870, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31781193

RESUMEN

BACKGROUND: Nonalcoholic fatty liver disease (NAFLD) patients are often prone to coronary artery disease (CAD), and CAD is found to be the main cause of death in NAFLD patients. The purpose of this study was to investigate the association between fatty acid desaturase 2 (FADS2) rs3834458 polymorphism and serum FADS2 level with NAFLD and CAD in Chinese Han population. MATERIALS AND METHODS: The serum level of FADS2 was detected by enzyme-linked immunosorbent assay (ELISA) in healthy people, NAFLD patients, and NAFLD patients combined with CAD (NAFLD+CAD). Polymerase chain reaction (PCR) was used to detect the genotypes of FADS2 rs3834458 in the three groups. RESULTS: Body mass index (BMI), glucose (GLU), total cholesterol (TC), and low-density lipoprotein cholesterol (LDL-C) of the NAFLD group and the NAFLD+CAD group were higher than those of the healthy control group (P < 0.05); the HDL-C of the NAFLD+CAD group was significantly lower than that of the healthy people and the NAFLD group (P < 0.05). The serum FADS2 concentration in the NAFLD+CAD group was significantly higher than that in the NAFLD group (P < 0.05) and the healthy people (P < 0.05). There was no significant difference in genotype distribution (χ 2 = 5.347, P < 0.497) and allele frequency (χ 2 = 3.322, P = 0.345) between the three groups. Logistic regression analysis showed that the T allele was not an independent risk factor for CAD with NAFLD (OR = 1.62, 95% CI: 0.422-6.180). CONCLUSIONS: Serum FADS2 concentration was positively correlated with the susceptibility of NAFLD with CAD, while the polymorphism of rs3834458 was not associated with NAFLD with CAD.