Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Magn Reson Med ; 91(3): 1115-1121, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38009988

RESUMEN

PURPOSE: Glycogen storage disease type III (GSD III) is a rare inherited metabolic disease characterized by excessive accumulation of glycogen in liver, skeletal muscle, and heart. Currently, there are no widely available noninvasive methods to assess tissue glycogen levels and disease load. Here, we use glycogen nuclear Overhauser effect (glycoNOE) MRI to quantify hepatic glycogen levels in a mouse model of GSD III. METHODS: Agl knockout mice (n = 13) and wild-type controls (n = 10) were scanned for liver glycogen content using glycoNOE MRI. All mice were fasted for 12 to 16 h before MRI scans. GlycoNOE signal was quantified by fitting the Z-spectrum using a four-pool Voigt lineshape model. Next, the fitted direct water saturation pool was removed and glycoNOE signal was estimated from the integral of the residual Z spectrum within -0.6 to -1.4 ppm. Glycogen concentration was also measured ex vivo using a biochemical assay. RESULTS: GlycoNOE MRI clearly distinguished Agl knockout mice from wild-type controls, showing a statistically significant difference in glycoNOE signals in the livers across genotypes. There was a linear correlation between glycoNOE signal and glycogen concentration determined by the biochemical assay. The obtained glycoNOE maps of mouse livers also showed higher glycogen levels in Agl knockout mice compared to wild-type mice. CONCLUSION: GlycoNOE MRI was used successfully as a noninvasive method to detect liver glycogen levels in mice, suggesting the potential of this method to be applied to assess glycogen storage diseases.


Asunto(s)
Enfermedad del Almacenamiento de Glucógeno Tipo III , Animales , Ratones , Enfermedad del Almacenamiento de Glucógeno Tipo III/diagnóstico por imagen , Enfermedad del Almacenamiento de Glucógeno Tipo III/genética , Glucógeno/metabolismo , Glucógeno Hepático , Modelos Animales de Enfermedad , Imagen por Resonancia Magnética , Ratones Noqueados
2.
bioRxiv ; 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38077043

RESUMEN

High-resolution spatial imaging is transforming our understanding of foundational biology. Spatial metabolomics is an emerging field that enables the dissection of the complex metabolic landscape and heterogeneity from a thin tissue section. Currently, spatial metabolism highlights the remarkable complexity in two-dimensional space and is poised to be extended into the three-dimensional world of biology. Here, we introduce MetaVision3D, a novel pipeline driven by computer vision techniques for the transformation of serial 2D MALDI mass spectrometry imaging sections into a high-resolution 3D spatial metabolome. Our framework employs advanced algorithms for image registration, normalization, and interpolation to enable the integration of serial 2D tissue sections, thereby generating a comprehensive 3D model of unique diverse metabolites across host tissues at mesoscale. As a proof of principle, MetaVision3D was utilized to generate the mouse brain 3D metabolome atlas (available at https://metavision3d.rc.ufl.edu/ ) as an interactive online database and web server to further advance brain metabolism and related research.

3.
Magn Reson Med ; 90(4): 1610-1624, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37279008

RESUMEN

PURPOSE: Water saturation shift referencing (WASSR) Z-spectra are used commonly for field referencing in chemical exchange saturation transfer (CEST) MRI. However, their analysis using least-squares (LS) Lorentzian fitting is time-consuming and prone to errors because of the unavoidable noise in vivo. A deep learning-based single Lorentzian Fitting Network (sLoFNet) is proposed to overcome these shortcomings. METHODS: A neural network architecture was constructed and its hyperparameters optimized. Training was conducted on a simulated and in vivo-paired data sets of discrete signal values and their corresponding Lorentzian shape parameters. The sLoFNet performance was compared with LS on several WASSR data sets (both simulated and in vivo 3T brain scans). Prediction errors, robustness against noise, effects of sampling density, and time consumption were compared. RESULTS: LS and sLoFNet performed comparably in terms of RMS error and mean absolute error on all in vivo data with no statistically significant difference. Although the LS method fitted well on samples with low noise, its error increased rapidly when increasing sample noise up to 4.5%, whereas the error of sLoFNet increased only marginally. With the reduction of Z-spectral sampling density, prediction errors increased for both methods, but the increase occurred earlier (at 25 vs. 15 frequency points) and was more pronounced for LS. Furthermore, sLoFNet performed, on average, 70 times faster than the LS-method. CONCLUSION: Comparisons between LS and sLoFNet on simulated and in vivo WASSR MRI Z-spectra in terms of robustness against noise and decreased sample resolution, as well as time consumption, showed significant advantages for sLoFNet.


Asunto(s)
Aprendizaje Profundo , Agua , Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos
5.
NMR Biomed ; 36(6): e4944, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37002814

RESUMEN

Chemical exchange saturation transfer (CEST) MRI has generated great interest for molecular imaging applications because it can image low-concentration solute molecules in vivo with enhanced sensitivity. CEST effects are detected indirectly through a reduction in the bulk water signal after repeated perturbation of the solute proton magnetization using one or more radiofrequency (RF) irradiation pulses. The parameters used for these RF pulses-frequency offset, duration, shape, strength, phase, and interpulse spacing-determine molecular specificity and detection sensitivity, thus their judicious selection is critical for successful CEST MRI scans. This review article describes the effects of applying RF pulses on spin systems and compares conventional saturation-based RF labeling with more recent excitation-based approaches that provide spectral editing capabilities for selectively detecting molecules of interest and obtaining maximal contrast.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Protones , Concentración de Iones de Hidrógeno , Ondas de Radio , Algoritmos
6.
Magn Reson Med ; 89(5): 1871-1887, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36579955

RESUMEN

PURPOSE: Dynamic glucose-enhanced (DGE) MRI relates to a group of exchange-based MRI techniques where the uptake of glucose analogues is studied dynamically. However, motion artifacts can be mistaken for true DGE effects, while motion correction may alter true signal effects. The aim was to design a numerical human brain phantom to simulate a realistic DGE MRI protocol at 3T that can be used to assess the influence of head movement on the signal before and after retrospective motion correction. METHODS: MPRAGE data from a tumor patient were used to simulate dynamic Z-spectra under the influence of motion. The DGE responses for different tissue types were simulated, creating a ground truth. Rigid head movement patterns were applied as well as physiological dilatation and pulsation of the lateral ventricles and head-motion-induced B0 -changes in presence of first-order shimming. The effect of retrospective motion correction was evaluated. RESULTS: Motion artifacts similar to those previously reported for in vivo DGE data could be reproduced. Head movement of 1 mm translation and 1.5 degrees rotation led to a pseudo-DGE effect on the order of 1% signal change. B0 effects due to head motion altered DGE changes due to a shift in the water saturation spectrum. Pseudo DGE effects were partly reduced or enhanced by rigid motion correction depending on tissue location. CONCLUSION: DGE MRI studies can be corrupted by motion artifacts. Designing post-processing methods using retrospective motion correction including B0 correction will be crucial for clinical implementation. The proposed phantom should be useful for evaluation and optimization of such techniques.


Asunto(s)
Glucosa , Procesamiento de Imagen Asistido por Computador , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Rotación , Artefactos
7.
Magn Reson Med ; 89(4): 1429-1440, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36373181

RESUMEN

PURPOSE: Acquisition of high-resolution Z-spectra for CEST or magnetization transfer contrast (MTC) MRI requires excessive scan times. Ultrafast Z-spectroscopy (UFZ) has been proposed to address this; however, the quality of in vivo UFZ spectra has been insufficient. Here, we present a simple approach to improve this. THEORY AND METHODS: UFZ imaging acquires full Z-spectra by encoding the spectral dimension spatially via a gradient applied concurrently with the RF saturation pulse. Different from previous implementations, both this saturation gradient and its readout were applied in the slice direction, resulting in a relatively uniform voxel composition. Phase-encoding was applied in both in-plane directions, allowing additional under-sampling and acceleration. RESULTS: In phantoms, UFZ imaging with through-slice Z-spectral encoding (TS-UFZ) provided Z-spectra of salicylic acid and egg white in excellent agreement with conventional acquisitions. In vivo brain Z-spectra were influenced by flow through the imaging slice which affected the Z-spectral baseline. Still, CEST signals could be quantified after baseline fitting and mapping the residual CEST signal. Amide proton transfer (APT) contrast intensities obtained by TS-UFZ were on the same order of magnitude as conventional CEST but with different contrast across slice which likely is a result of different tissue regions contributing. CONCLUSION: TS-UFZ approach improves signal stability and spectral uniformity over previous implementations and allows high spectral-resolution imaging of saturation transfer effects in the human brain at 3T. This implementation allows for further acceleration by reducing phase encoding steps and thus opens up the possibility of mapping dynamic CEST signals in vivo with a practical temporal resolution.


Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Espectroscopía de Resonancia Magnética/métodos , Protones , Fantasmas de Imagen
8.
NMR Biomed ; 36(6): e4778, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-35642102

RESUMEN

Magnetic resonance (MR) is a powerful technique for noninvasively probing molecular species in vivo but suffers from low signal sensitivity. Saturation transfer (ST) MRI approaches, including chemical exchange saturation transfer (CEST) and conventional magnetization transfer contrast (MTC), allow imaging of low-concentration molecular components with enhanced sensitivity using indirect detection via the abundant water proton pool. Several recent studies have shown the utility of chemical exchange relayed nuclear Overhauser effect (rNOE) contrast originating from nonexchangeable carbon-bound protons in mobile macromolecules in solution. In this review, we describe the mechanisms leading to the occurrence of rNOE-based signals in the water saturation spectrum (Z-spectrum), including those from mobile and immobile molecular sources and from molecular binding. While it is becoming clear that MTC is mainly an rNOE-based signal, we continue to use the classical MTC nomenclature to separate it from the rNOE signals of mobile macromolecules, which we will refer to as rNOEs. Some emerging applications of the use of rNOEs for probing macromolecular solution components such as proteins and carbohydrates in vivo or studying the binding of small substrates are discussed.


Asunto(s)
Algoritmos , Encéfalo , Encéfalo/metabolismo , Imagen por Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/métodos , Protones
9.
Biomedicines ; 10(9)2022 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-36140239

RESUMEN

This proof-of-concept study looked at the feasibility of using a thiol-water proton exchange (i.e., CEST) MRI contrast to detect in vivo hepatic N-acetylcysteine (NAC) uptake. The feasibility of detecting NAC-induced glutathione (GSH) biosynthesis using CEST MRI was also investigated. The detectability of the GSH amide and NAC thiol CEST effect at B0 = 7 T was determined in phantom experiments and simulations. C57BL/6 mice were injected intravenously (IV) with 50 g L-1 NAC in PBS (pH 7) during MRI acquisition. The dynamic magnetisation transfer ratio (MTR) and partial Z-spectral data were generated from the acquisition of measurements of the upfield NAC thiol and downfield GSH amide CEST effects in the liver. The 1H-NMR spectroscopy on aqueous mouse liver extracts, post-NAC-injection, was performed to verify hepatic NAC uptake. The dynamic MTR and partial Z-spectral data revealed a significant attenuation of the mouse liver MR signal when a saturation pulse was applied at -2.7 ppm (i.e., NAC thiol proton resonance) after the IV injection of the NAC solution. The 1H-NMR data revealed the presence of hepatic NAC, which coincided strongly with the increased upfield MTR in the dynamic CEST data, providing strong evidence that hepatic NAC uptake was detected. However, this MTR enhancement was attributed to a combination of NAC thiol CEST and some other upfield MT-generating mechanism(s) to be identified in future studies. The detection of hepatic GSH via its amide CEST MRI contrast was inconclusive based on the current results.

10.
Magn Reson Med ; 88(2): 901-915, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35394084

RESUMEN

PURPOSE: Saturation transfer MRI has previously been used to probe molecular binding interactions with signal enhancement via the water signal. Here, we detail the relayed nuclear overhauser effect (rNOE) based mechanisms of this signal enhancement, develop a strategy of quantifying molecular binding affinity, i.e., the dissociation constant ( KD$$ {K}_D $$ ), and apply the method to detect electrostatic binding of several charged small biomolecules. Another goal was to estimate the detection limit for transient receptor-substrate binding. THEORY AND METHODS: The signal enhancement mechanism was quantitatively described by a three-step magnetization transfer model, and numerical simulations were performed to verify this theory. The binding equilibria of arginine, choline, and acetyl-choline to anionic resin were studied as a function of ligand concentration, pH, and salt content. Equilibrium dissociation constants ( KD$$ {K}_D $$ ) were determined by fitting the multiple concentration data. RESULTS: The numerical simulations indicate that the signal enhancement is sufficient to detect the molecular binding of sub-millimolar (∼100 µM) concentration ligands to low micromolar levels of molecular targets. The measured rNOE signals from arginine, choline, and acetyl-choline binding experiments show that several magnetization transfer pathways (intra-ligand rNOEs and intermolecular rNOEs) can contribute. The rNOEs that arise from molecular ionic binding were influenced by pH and salt concentration. The molecular binding strengths in terms of KD$$ {K}_{\mathrm{D}} $$ ranged from 70-160 mM for the three cations studied. CONCLUSION: The capability to use MRI to detect the transient binding of small substrates paves a pathway towards the detection of micromolar level receptor-substrate binding in vivo.


Asunto(s)
Protones , Agua , Arginina , Colina , Ligandos , Electricidad Estática
11.
Nat Biotechnol ; 40(7): 1143-1149, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35102291

RESUMEN

Imaging of gene-expression patterns in live animals is difficult to achieve with fluorescent proteins because tissues are opaque to visible light. Imaging of transgene expression with magnetic resonance imaging (MRI), which penetrates to deep tissues, has been limited by single reporter visualization capabilities. Moreover, the low-throughput capacity of MRI limits large-scale mutagenesis strategies to improve existing reporters. Here we develop an MRI system, called GeneREFORM, comprising orthogonal reporters for two-color imaging of transgene expression in deep tissues. Starting from two promiscuous deoxyribonucleoside kinases, we computationally designed highly active, orthogonal enzymes ('reporter genes') that specifically phosphorylate two MRI-detectable synthetic deoxyribonucleosides ('reporter probes'). Systemically administered reporter probes exclusively accumulate in cells expressing the designed reporter genes, and their distribution is displayed as pseudo-colored MRI maps based on dynamic proton exchange for noninvasive visualization of transgene expression. We envision that future extensions of GeneREFORM will pave the way to multiplexed deep-tissue mapping of gene expression in live animals.


Asunto(s)
Imagen por Resonancia Magnética , Animales , Genes Reporteros/genética , Imagen por Resonancia Magnética/métodos , Transgenes
12.
NMR Biomed ; 35(2): e4624, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34585813

RESUMEN

Dynamic glucose-enhanced (DGE) magnetic resonance imaging (MRI) has shown potential for tumor imaging using D-glucose as a biodegradable contrast agent. The DGE signal change is small at 3 T (around 1%) and accurate detection is hampered by motion. The intravenous D-glucose injection is associated with transient side effects that can indirectly generate subject movements. In this study, the aim was to study DGE arterial input functions (AIFs) in healthy volunteers at 3 T for different scanning protocols, as a step towards making the glucose chemical exchange saturation transfer (glucoCEST) protocol more robust. Two different infusion durations (1.5 and 4.0 min) and saturation frequency offsets (1.2 and 2.0 ppm) were used. The effect of subject motion on the DGE signal was studied by using motion estimates retrieved from standard retrospective motion correction to create pseudo-DGE maps, where the apparent DGE signal changes were entirely caused by motion. Furthermore, the DGE AIFs were compared with venous blood glucose levels. A significant difference (p = 0.03) between arterial baseline and postinfusion DGE signal was found after D-glucose infusion. The results indicate that the measured DGE AIF signal change depends on both motion and blood glucose concentration change, emphasizing the need for sufficient motion correction in glucoCEST imaging. Finally, we conclude that a longer infusion duration (e.g. 3-4 min) should preferably be used in glucoCEST experiments, because it can minimize the glucose infusion side effects without negatively affecting the DGE signal change.


Asunto(s)
Glucosa/química , Imagen por Resonancia Magnética/métodos , Adulto , Glucemia/análisis , Humanos , Aumento de la Imagen , Masculino , Factores de Tiempo
13.
NMR Biomed ; 35(2): e4626, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34668251

RESUMEN

Chemical exchange saturation transfer (CEST) magnetic resonance imaging has shown promise for classifying tumors based on their aggressiveness, but CEST contrast is complicated by multiple signal sources and thus prolonged acquisition times are often required to extract the signal of interest. We investigated whether deep learning could help identify pertinent Z-spectral features for distinguishing tumor aggressiveness as well as the possibility of acquiring only the pertinent spectral regions for more efficient CEST acquisition. Human breast cancer cells, MDA-MB-231 and MCF-7, were used to establish bi-lateral tumor xenografts in mice to represent higher and lower aggressive tumors, respectively. A convolutional neural network (CNN)-based classification model, trained on simulated data, utilized Z-spectral features as input to predict labels of different tissue types, including MDA-MB-231, MCF-7, and muscle tissue. Saliency maps reported the influence of Z-spectral regions on classifying tissue types. The model was robust to noise with an accuracy of more than 91.5% for low and moderate noise levels in simulated testing data (SD of noise less than 2.0%). For in vivo CEST data acquired with a saturation pulse amplitude of 2.0 µT, the model had a superior ability to delineate tissue types compared with Lorentzian difference (LD) and magnetization transfer ratio asymmetry (MTRasym ) analysis, classifying tissues to the correct types with a mean accuracy of 85.7%, sensitivity of 81.1%, and specificity of 94.0%. The model's performance did not improve substantially when using data acquired at multiple saturation pulse amplitudes or when adding LD or MTRasym spectral features, and did not change when using saliency map-based partial or downsampled Z-spectra. This study demonstrates the potential of CNN-based classification to distinguish between different tumor types and muscle tissue, and speed up CEST acquisition protocols.


Asunto(s)
Neoplasias de la Mama/clasificación , Neoplasias de la Mama/diagnóstico por imagen , Aprendizaje Profundo , Imagen por Resonancia Magnética/métodos , Animales , Línea Celular Tumoral , Femenino , Humanos , Ratones , Redes Neurales de la Computación
14.
Magn Reson Med ; 85(3): 1643-1654, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32970889

RESUMEN

PURPOSE: CEST MRI experiments of mobile macromolecules, for example, proteins, carbohydrates, and phospholipids, often show signals due to saturation transfer from aliphatic protons to water. Currently, the mechanism of this nuclear Overhauser effect (NOE)-based transfer pathway is not completely understood and could be due either to NOEs directly to bound water or NOEs relayed intramolecularly via exchangeable protons. We used glycogen as a model system to investigate this saturation transfer pathway in sugar polymer solution. METHODS: To determine whether proton exchange affected saturation transfer, saturation spectra (Z-spectra) were measured for glycogen solutions of different pH, D2 O/H2 O ratio, and glycogen particle size. A theoretical model was derived to analytically describe the NOE-based signals in these spectra. Numerical simulations were performed to verify this theory, which was further tested by fitting experimental data for different exchange regimes. RESULTS: Signal intensities of aliphatic NOEs in Z-spectra of glycogen in D2 O solution were influenced by hydroxyl proton exchange rates, whereas those in H2 O were not. This indicates that the primary transfer pathway is an exchange-relayed NOE from these aliphatic protons to neighboring hydroxyl protons, followed by the exchange to water protons. Experimental data for glycogen solutions in D2 O and H2 O could be analyzed successfully using an analytical theory derived for such relayed NOE transfer, which was further validated using numerical simulations with the Bloch equations. CONCLUSION: The predominant mechanism underlying aliphatic signals in Z-spectra of mobile carbohydrate polymers is intramolecular relayed NOE transfer followed by proton exchange.


Asunto(s)
Protones , Agua , Imagen por Resonancia Magnética , Polímeros , Proteínas
15.
Proc Natl Acad Sci U S A ; 117(6): 3144-3149, 2020 02 11.
Artículo en Inglés | MEDLINE | ID: mdl-32001509

RESUMEN

Glycogen plays a central role in glucose homeostasis and is abundant in several types of tissue. We report an MRI method for imaging glycogen noninvasively with enhanced detection sensitivity and high specificity, using the magnetic coupling between glycogen and water protons through the nuclear Overhauser enhancement (NOE). We show in vitro that the glycogen NOE (glycoNOE) signal is correlated linearly with glycogen concentration, while pH and temperature have little effect on its intensity. For validation, we imaged glycoNOE signal changes in mouse liver, both before and after fasting and during glucagon infusion. The glycoNOE signal was reduced by 88 ± 16% (n = 5) after 24 h of fasting and by 76 ± 22% (n = 5) at 1 h after intraperitoneal (i.p.) injection of glucagon, which is known to rapidly deplete hepatic glycogen. The ability to noninvasively image glycogen should allow assessment of diseases in which glucose metabolism or storage is altered, for instance, diabetes, cardiac disease, muscular disorders, cancer, and glycogen storage diseases.


Asunto(s)
Glucógeno , Imagen por Resonancia Magnética/métodos , Animales , Ayuno/fisiología , Glucógeno/análisis , Glucógeno/química , Glucógeno/metabolismo , Hígado/diagnóstico por imagen , Hígado/metabolismo , Ratones , Protones , Agua/química
16.
NMR Biomed ; 33(1): e4188, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31793114

RESUMEN

Amide-, amine-, and hydroxyl-water proton exchange can generate MRI contrast through chemical exchange saturation transfer (CEST). In this study, we show that thiol-water proton exchange can also generate quantifiable CEST effects under near-physiological conditions (pH = 7.2 and 37°C) through the characterization of the pH dependence of thiol proton exchange in phosphate-buffered solutions of glutathione, cysteine, and N-acetylcysteine. The spontaneous, base-catalyzed, and buffer-catalyzed exchange contributions to the thiol exchange were analyzed. The thiol-water proton exchange of glutathione and cysteine was found to be too fast to generate a CEST effect around neutral pH due to significant base catalysis. The thiol-water proton exchange of N-acetylcysteine was found to be much slower, yet still in the fast-exchange regime with significant base and buffer catalysis, resulting in a 9.5% attenuation of the water signal at pH 7.2 in a slice-selective CEST NMR experiment. Furthermore, the N-acetylcysteine thiol CEST was also detectable in human serum albumin and agarose phantoms.


Asunto(s)
Acetilcisteína/metabolismo , Cisteína/metabolismo , Glutatión/metabolismo , Imagen por Resonancia Magnética , Protones , Compuestos de Sulfhidrilo/metabolismo , Agua/metabolismo , Humanos , Concentración de Iones de Hidrógeno , Albúmina Sérica Humana/metabolismo
17.
Magn Reson Med ; 84(1): 247-262, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31872916

RESUMEN

PURPOSE: Dynamic glucose enhanced (DGE) MRI has shown potential for imaging glucose delivery and blood-brain barrier permeability at fields of 7T and higher. Here, we evaluated issues involved with translating d-glucose weighted chemical exchange saturation transfer (glucoCEST) experiments to the clinical field strength of 3T. METHODS: Exchange rates of the different hydroxyl proton pools and the field-dependent T2 relaxivity of water in d-glucose solution were used to simulate the water saturation spectra (Z-spectra) and DGE signal differences as a function of static field strength B0 , radiofrequency field strength B1 , and saturation time tsat . Multislice DGE experiments were performed at 3T on 5 healthy volunteers and 3 glioma patients. RESULTS: Simulations showed that DGE signal decreases with B0 , because of decreased contributions of glucoCEST and transverse relaxivity, as well as coalescence of the hydroxyl and water proton signals in the Z-spectrum. At 3T, because of this coalescence and increased interference of direct water saturation and magnetization transfer contrast, the DGE effect can be assessed over a broad range of saturation frequencies. Multislice DGE experiments were performed in vivo using a B1 of 1.6 µT and a tsat of 1 second, leading to a small glucoCEST DGE effect at an offset frequency of 2 ppm from the water resonance. Motion correction was essential to detect DGE effects reliably. CONCLUSION: Multislice glucoCEST-based DGE experiments can be performed at 3T with sufficient temporal resolution. However, the effects are small and prone to motion influence. Therefore, motion correction should be used when performing DGE experiments at clinical field strengths.


Asunto(s)
Neoplasias Encefálicas , Glioma , Neoplasias Encefálicas/diagnóstico por imagen , Glioma/diagnóstico por imagen , Glucosa , Voluntarios Sanos , Humanos , Imagen por Resonancia Magnética
18.
Magn Reson Med ; 82(4): 1471-1479, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31106918

RESUMEN

PURPOSE: Vascular disrupting therapy of cancer has become a promising approach not only to regress tumor growth directly but also to boost the delivery of chemotherapeutics in the tumor. An imaging approach to monitor the changes in tumor vascular permeability, therefore, has important applications for monitoring of vascular disrupting therapies. METHODS: Mice bearing CT26 subcutaneous colon tumors were injected intravenously with 150 kD dextran (Dex150, diameter, d~ 20 nm, 375 mg/kg), tumor necrosis factor-alpha (TNF-α; 1 µg per mouse), or both (n = 3 in each group). The Z-spectra were acquired before and 2 h after the injection, and the chemical exchange saturation transfer (CEST) signals in the tumors as quantified by asymmetric magnetization transfer ratio (MTRasym ) at 1 ppm were compared. RESULTS: The results showed a significantly stronger CEST contrast enhancement at 1 ppm (∆MTRasym = 0.042 ± 0.002) in the TNF-α-treated tumors than those by Dex150 alone (∆MTRasym = 0.000 ± 0.005, P = 0.0229) or TNF-α alone (∆MTRasym = 0.002 ± 0.004, P = 0.0264), indicating that the TNF-α treatment strongly augmented the tumor uptake of 150 kD dextran. The MRI findings were verified by fluorescence imaging and immunofluorescence microscopy. CONCLUSIONS: High molecular weight dextrans can be used as safe and sensitive CEST MRI contrast agents for monitoring tumor response to vascular disrupting therapy and, potentially, for developing dextran-based theranostic drug delivery systems.


Asunto(s)
Antineoplásicos/farmacología , Dextranos/farmacología , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neovascularización Patológica/diagnóstico por imagen , Animales , Monitoreo de Drogas , Femenino , Ratones , Ratones Endogámicos BALB C , Neoplasias Experimentales/irrigación sanguínea , Neoplasias Experimentales/diagnóstico por imagen
19.
Magn Reson Med ; 81(3): 1993-2000, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30206994

RESUMEN

PURPOSE: 3-O-Methyl-D-glucose (3-OMG) is a nonmetabolizable structural analog of glucose that offers potential to be used as a CEST-contrast agent for tumor detection. Here, we explore it for CEST-detection of malignant brain tumors and compare it with D-glucose. METHODS: Glioma xenografts of a U87-MG cell line were implanted in five mice. Dynamic 3-OMG weighted images were collected using CEST-MRI at 11.7 T at a single offset of 1.2 ppm, showing the effect of accumulation of the contrast agent in the tumor, following an intravenous injection of 3-OMG (3 g/kg). RESULTS: Tumor regions showed higher enhancement as compared to contralateral brain. The CEST contrast enhancement in the tumor region ranged from 2.5-5.0%, while it was 1.5-3.5% in contralateral brain. Previous D-glucose studies of the same tumor model showed an enhancement of 1.5-3.0% and 0.5-1.5% in tumor and contralateral brain, respectively. The signal gradually stabilized to a value that persisted for the length of the scan. CONCLUSIONS: 3-OMG shows a CEST contrast enhancement that is approximately twice as much as that of D-glucose for a similar tumor line. In view of its suggested low toxicity and transport properties across the BBB, 3-OMG provides an option to be used as a nonmetallic contrast agent for evaluating brain tumors.


Asunto(s)
3-O-Metilglucosa/administración & dosificación , 3-O-Metilglucosa/farmacocinética , Neoplasias Encefálicas/diagnóstico por imagen , Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Glioma/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Administración Oral , Animales , Área Bajo la Curva , Barrera Hematoencefálica , Encéfalo/diagnóstico por imagen , Línea Celular Tumoral , Femenino , Glucosa/administración & dosificación , Glucosa/farmacocinética , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Ratones , Ratones SCID , Trasplante de Neoplasias
20.
Chemistry ; 24(6): 1259-1263, 2018 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-29266443

RESUMEN

Although T2 -exchange (T2ex ) NMR phenomena have been known for decades, there has been a resurgence of interest to develop T2ex MRI contrast agents. One indispensable advantage of T2ex MR agents is the possibility of using non-toxic and/or bio-compatible diamagnetic compounds with intermediate exchangeable protons. Herein a library of phenol-based compounds is screened and their T2ex contrast (exchange relaxivity, r2ex ) at 9.4 T determined. The T2ex contrast of phenol protons allows direct detection by MRI at a millimolar concentration level. The effect of chemical modification of the phenol on the T2ex MRI contrast through modulation of exchange rate and chemical shift was also studied and provides a guideline for use of endogenous and exogenous phenols for T2ex MRI contrast. As a proof-of-principle application, phenol T2ex contrast can be used to detect enzyme activity in a tyrosinase-catalyzed catechol oxidation reaction.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...