Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diabetol Metab Syndr ; 16(1): 39, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38331895

RESUMEN

BACKGROUND: Exocrine pancreatic insufficiency (EPI) can be associated with all types of diabetes. Pancreatic enzyme replacement therapy (PERT) has short and long-term benefits in subjects with EPI, but its effects on diabetes control are uncertain. We aimed to study the effects of PERT initiation on glycemic control in subjects with diabetes and EPI from any cause. METHODS: In this retrospective study, we compared subjects with EPI and diabetes who were prescribed PERT with subjects with diabetes who had a fecal elastase-1 concentration dosage, but did not receive PERT. The primary outcome was the effect of PERT on hypoglycemia frequency and severity. The secondary outcomes were the effects of PERT on gastro-intestinal disorders, HbA1c and body mass index (BMI). RESULTS: 48 subjects were included in each group. Overall, PERT did not have any significant effect on hypoglycemia frequency or severity, but hypoglycemia frequency tended to decrease in subjects with chronic pancreatitis. While 19% of subjects experienced mild hyperglycemia after PERT initiation, we did not report any keto-acidosis or any other severe adverse event. Gastro-intestinal disorders improved in 80% of subjects treated with PERT, versus in 20% of control subjects (p = 0.02). Gastro-intestinal disorders improved in 87% of subjects with recommended dosage of PERT, versus in 50% of subjects with underdosage (NS). HbA1c and BMI evolution did not differ between the groups. CONCLUSIONS: PERT initiation is safe in subjects with diabetes and EPI. It does not globally decrease hypoglycemia severity of frequency, but is associated with a decrease in gastro-intestinal disorders. Trial registration Retrospectively registered. The database was registered with the Commission Nationale Informatique et Libertés (CNIL), registration number: 2203351v0. The study was approved by the local ethics committee CLEP, registration number: AAA-2023-09047.

2.
Front Neurol ; 14: 1256984, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38020587

RESUMEN

Background: Sudomotor dysfunction is one of the earliest manifestations of small fiber neuropathy (SFN), reflecting the alteration of sympathetic C fiber innervation of the sweat glands. Among other techniques, such innervation can be assessed by measuring electrochemical skin conductance (ESC) in microsiemens (µS). In this study, ESC was measured at the feet to detect distal SFN. For this objective, the performance of a new device, the Body Scan® (Withings, France), intended for home use, was compared with that of a reference device, the Sudoscan® (Impeto Medical, France), which requires a hospital setting. Methods: In patients with diabetes with or without neuropathy or non-diabetic patients with lower-limb neuropathy, the diagnostic performance of the Body Scan® measurement was assessed by calculating its sensitivity (Se) and specificity (Sp) to detect at least moderate SFN (Se70 and Sp70), defined by a value of feet ESC ≤ 70 µS and > 50 µS on the Sudoscan® measure, or severe SFN (Se50 and Sp50), defined by a value of feet ESC ≤ 50 µS on the Sudoscan® measure. The agreement between the two devices was assessed with the analysis of Bland-Altman plots, mean absolute error (MAE), and root mean squared error (RMSE) calculations. The repeatability of the measurements was also compared between the two devices. Results: A total of 147 patients (52% men, mean age 59 years old, 76% diabetic) were included in the analysis. The sensitivity and specificity to detect at least moderate or severe SFN were: Se70 = 0.91 ([0.83, 0.96]), Sp70 = 0.97 ([0.88, 0.99]), Se50 = 0.91 ([0.80, 0.98]), and Sp50 = 0.99 ([0.94, 1]), respectively. The bias and 95% limits of agreement were 1.5 [-5.4, 8.4]. The MAE was 2.9 and the RMSE 3.8. The intra-sample variability was 2.0 for the Body Scan® and 2.3 for the Sudoscan®. Conclusion: The ESC measurements provided by the Body Scan® were in almost perfect agreement with those provided by the reference device, the Sudoscan®, which validates the accuracy of the Body Scan® for the detection of SFN. By enabling simple, rapid, and autonomous use by the patient at home, this new technique will facilitate screening and monitoring of SFN in daily practice. Clinical trial registration: ClinicalTrials.gov, identifier NCT05178459.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...