Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 116
Filtrar
1.
Kyobu Geka ; 77(5): 330-334, 2024 May.
Artículo en Japonés | MEDLINE | ID: mdl-38720599

RESUMEN

Hepatic abscesses are divided into bacterial and amoebic types. Although the prognosis of bacterial liver abscesses has improved owing to progress in drainage techniques and antimicrobial agents, poor outcomes remain common. While there have been some reports of amoebic liver abscesses complicated by thrombosis, bacterial liver abscesses and subsequent thrombus in the right atrium are very rare. We herein report the case of an 82-year-old man. He had suffered acute obstructive suppurative cholangitis 10 months previously, and bile culture yielded Enterococcus faecalis. In the present case, a right atrial thrombus caused by a bacterial liver abscess was observed and the causative organism was thought to be Enterococcus faecalis, for which was detected in a blood culture was positive. The patient was successfully treated with hepatic abscess drainage and surgical right atrial thrombectomy under cardiopulmonary bypass with a beating heart.


Asunto(s)
Atrios Cardíacos , Cardiopatías , Absceso Piógeno Hepático , Trombosis , Humanos , Masculino , Absceso Piógeno Hepático/diagnóstico por imagen , Absceso Piógeno Hepático/complicaciones , Absceso Piógeno Hepático/cirugía , Anciano de 80 o más Años , Atrios Cardíacos/cirugía , Trombosis/cirugía , Trombosis/diagnóstico por imagen , Trombosis/complicaciones , Cardiopatías/complicaciones , Cardiopatías/cirugía , Cardiopatías/diagnóstico por imagen , Enterococcus faecalis , Infecciones por Bacterias Grampositivas/complicaciones
2.
Sleep Breath ; 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358413

RESUMEN

PURPOSE: This study aimed to develop an unobtrusive method for home sleep apnea testing (HSAT) utilizing micromotion signals obtained by a piezoelectric rubber sheet sensor. METHODS: Algorithms were designated to extract respiratory and ballistocardiogram components from micromotion signals and to detect respiratory events as the characteristic separation of the fast envelope of the respiration component from the slow envelope. In 78 adults with diagnosed or suspected sleep apnea, micromotion signal was recorded with a piezoelectric rubber sheet sensor placed beneath the bedsheet during polysomnography. In a half of the subjects, the algorithms were optimized to calculate respiratory event index (REI), estimating apnea-hypopnea index (AHI). In the other half of subjects, the performance of REI in classifying sleep apnea severity was evaluated. Additionally, the predictive value of the frequency of cyclic variation in heart rate (Fcv) obtained from the ballistocardiogram was assessed. RESULTS: In the training group, the optimized REI showed a strong correlation with the AHI (r = 0.93). Using the optimal cutoff of REI ≥ 14/h, subjects with an AHI ≥ 15 were identified with 77.8% sensitivity and 90.5% specificity. When applying this REI to the test group, it correlated closely with the AHI (r = 0.92) and identified subjects with an AHI ≥ 15 with 87.5% sensitivity and 91.3% specificity. While Fcv showed a modest correlation with AHI (r = 0.46 and 0.66 in the training and test groups), it lacked independent predictive power for AHI. CONCLUSION: The analysis of respiratory component of micromotion using piezoelectric rubber sheet sensors presents a promising approach for HSAT, providing a practical and effective means of estimating sleep apnea severity.

3.
Jpn J Clin Oncol ; 54(3): 329-338, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38061911

RESUMEN

OBJECTIVE: Real-world evidence regarding enfortumab vedotin for unresectable or metastatic urothelial carcinoma is scarce, particularly in Japan. We investigated real-world data focusing on patient background, previous treatments, response, survival and adverse events in patients receiving enfortumab vedotin. METHODS: A multicentre database was used to register 556 patients diagnosed with metastatic urothelial carcinoma from 2008 to 2023; 34 patients (6.1%) treated with enfortumab vedotin were included. Best radiographic objective responses were evaluated using the Response Evaluation Criteria in Solid Tumors (v1.1) during treatments. Overall survival and progression-free survival were estimated (Kaplan-Meier method). Toxicities were reported according to the Common Terminology Criteria for Adverse Events, version 5.0. The relative dose intensity, which could impact oncological outcomes, was calculated. RESULTS: The median number of enfortumab vedotin therapy cycles was 5. The best objective response to enfortumab vedotin was partial response, stable disease and progressive disease in 19 (56%), 5 (15%) and 10 (29%) patients, respectively. The median overall survival and progression-free survival after the first enfortumab vedotin dose were 16 and 9 months, respectively. No significant relationship was observed between survival outcomes after enfortumab vedotin initiation and the enfortumab vedotin relative dose intensity. The median overall survival from first-line platinum-based chemotherapy initiation was 42 months. Twenty-six (76%) patients experienced any grade of enfortumab vedotin-related toxicities; eight (24%) experienced Grades 3-4 toxicities, the most common being skin toxicity (any grade, 47%; Grades 3-4, 12%). CONCLUSIONS: Here, we report real-world evidence for enfortumab vedotin therapy in Japan. Tumour responses and safety profiles were comparable with those of clinical trials on this novel treatment.


Asunto(s)
Anticuerpos Monoclonales , Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Humanos , Carcinoma de Células Transicionales/tratamiento farmacológico , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Japón , Neoplasias de la Vejiga Urinaria/patología , Platino (Metal)/uso terapéutico
4.
J Obstet Gynaecol Res ; 49(7): 1854-1866, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37088869

RESUMEN

AIMS: This study aimed to develop a scale to screen for eating disorders in female athletes. METHODS: Preliminary survey: A total of 275 female athletes (mean age: 19.4 ± 1.0 years) and 7 female athletes diagnosed with eating disorders (mean age: 20.1 ± 2.5 years) were administered screening items prepared based on an existing scale, followed by exploratory factor analysis. Main survey: Six items, relating to three factors, were extracted, and 201 female athletes (mean age: 22.3 ± 4.8 years) and 6 female athletes diagnosed with current or a history of eating disorders (mean age: 18.8 ± 2.9 years) were queried. The diagnostic validity of the scale was then evaluated. RESULTS: Preliminary survey: Questions (α = 0.71) were extracted from six items, relating to three factors, and collectively termed the University of Tokyo's eating disorders inventory in female athletes (TEDIFA). To determine the scale cut-off score, ROC analysis was performed with the total score, and the cut-off and gray zone scores were set at 13 and 11, respectively. Main survey: At the cut-off score of 13, AUC, sensitivity, and specificity were 0.83 (p < 0.05), 75%, and 90%, respectively. CONCLUSIONS: The scale that was developed, TEDIFA, consisted of six items. The cut-off scores were set at 11 for the gray zone (sensitivity: 75%; specificity: 56%; accurate diagnosis rate: 60%), and 13 for positivity (sensitivity: 75%; specificity: 90%; accurate diagnosis rate: 87%), demonstrating the reliability and validity of the scale.


Asunto(s)
Atletas , Trastornos de Alimentación y de la Ingestión de Alimentos , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Reproducibilidad de los Resultados , Trastornos de Alimentación y de la Ingestión de Alimentos/diagnóstico , Curva ROC , Encuestas y Cuestionarios
5.
RSC Adv ; 13(19): 12941-12950, 2023 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-37114021

RESUMEN

Developing new concepts to design noble-metal-free catalysts is necessary to achieve the hydrogen economy and reduce global CO2 emissions. Here, we provide novel insights into the design of catalysts with internal magnetic fields by investigating the relationship between the hydrogen evolution reaction (HER) and the Slater-Pauling rule. This rule states that adding an element to a metal reduces the alloy's saturation magnetization by an amount proportional to the number of valence electrons outside the d shell of the added element. We observed that rapid hydrogen evolution occurred when the magnetic moment of the catalyst was high, as predicted by the Slater-Pauling rule. Numerical simulation of the dipole interaction revealed a critical distance, r C, at which the proton trajectory changes from a Brownian random walk to a close-approach orbit towards the ferromagnetic catalyst. The calculated r C was proportional to the magnetic moment, consistent with the experimental data. Interestingly, r C was proportional to the number of protons contributing to the HER and accurately reflected the migration length for the proton dissociation and hydration and the O-H bond length in water. The magnetic dipole interaction between the nuclear spin of the proton and the electronic spin of the magnetic catalyst is verified for the first time. The findings of this study will open a new direction in catalyst design aided by an internal magnetic field.

6.
Asian Cardiovasc Thorac Ann ; 31(2): 75-80, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36330614

RESUMEN

BACKGROUND: Total arch replacement (TAR) with a frozen elephant trunk (FET) is a common technique for acute aortic dissection, but there is no consensus on the optimal size of the FET. METHODS: Forty-four patients who underwent TAR with FET for acute aortic dissection at our hospital since 2014 were included. The aortic diameter obtained from FET was measured on postoperative computed tomography (CT) and the estimated oversizing ratio was calculated. We investigated the relationship between the estimated oversizing ratio and postoperative outcomes. We also measured the maximum true lumen diameter, circumference of the true lumen, and total aortic diameter at the same level as the FET end on preoperative CT and examined the correlation with the aortic diameter obtained from FET. RESULTS: The average estimated oversizing ratio was 109%. Early postoperative CT showed complete thrombosis of the false lumen in 41 (93.2%) patients. No distal stent graft-induced new entry occurred during follow-up. The correlation coefficients between the three measurements and aortic diameter obtained from FET were 0.64 (maximum true lumen diameter), 0.76 (true lumen diameter calculated from circumference), and 0.72 (total aortic diameter), respectively. CONCLUSIONS: The aortic diameter obtained from FET on postoperative CT was strongly correlated with the true lumen diameter calculated from the circumference and total aortic diameter on preoperative CT. It is reasonable to select a size of approximately 130% of the true lumen diameter calculated from the circumference or 80% to 85% of the total aortic diameter.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Humanos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Prótesis Vascular , Stents , Estudios Retrospectivos , Resultado del Tratamiento
7.
Jpn J Clin Oncol ; 53(3): 253-262, 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36484294

RESUMEN

OBJECTIVE: To develop the first Japanese real-world evidence of switch-maintenance avelumab in advanced, unresectable or metastatic urothelial carcinoma (aUC). METHODS: A multicenter-derived database registered 505 patients diagnosed with aUC between 2008 and 2021. Of these, 204 patients (40%) were selected and stratified according to the type of therapy used: maintenance avelumab group (27 [5.3%]), second-line (2 L) pembrolizumab group (103 [20%]) and 2 L cytotoxic chemotherapy group (74 [15%]). The progression-free survival and overall survival from the initiation of following therapy were compared. Tumor response was evaluated based on the Response Evaluation Criteria in Solid Tumors guideline v1.1 during the treatment period. A detailed analysis was performed in the maintenance avelumab group to investigate possible factors associated with response to avelumab therapy. RESULTS: The maintenance avelumab group had a longer overall survival, not progression-free survival, compared with the other two treatment groups. The median treatment-free interval between the last dose of first-line (1 L) chemotherapy and the initiation of avelumab therapy was 6 weeks (range, 3-22). Disease control rate of maintenance avelumab therapy in patients with a treatment-free interval of ≤6 weeks was higher than that in patients with a treatment-free interval of >6 weeks (77 vs 40%, P = 0.029). The patients showing objective response to 1 L chemotherapy were less likely to experience tumor relapse (4 of 19) after the initiation of avelumab therapy compared with those showing stable disease (7 of 8). CONCLUSIONS: Objective response to 1 L chemotherapy and early induction of maintenance avelumab therapy may be associated with increased benefit from maintenance avelumab therapy.


Asunto(s)
Carcinoma de Células Transicionales , Neoplasias de la Vejiga Urinaria , Humanos , Carcinoma de Células Transicionales/tratamiento farmacológico , Pueblos del Este de Asia , Neoplasias de la Vejiga Urinaria/tratamiento farmacológico , Inmunoterapia
8.
J Phys Ther Sci ; 34(10): 683-688, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36213190

RESUMEN

[Purpose] To identify the lumbar loading movements necessary in clinical practice. [Participants and Methods] A questionnaire survey was conducted among physical and occupational therapists in Japan. There were no exclusion criteria regarding the number of years of experience, age, or field of employment. The participants were randomly selected and administered the questionnaire. They were asked to list and rank the lumbar loadings they considered necessary. [Results] A total of 739 respondents participated in the survey. The results of this nationwide survey indicated that the lifting movement of heavy objects in the trunk flexion position was the most common movement (for 354 participants). [Conclusion] The main loading movements of the lumbar spine were reported to be heavy lifting movements (in the trunk flexion position) and trunk rotation movements. As perspectives, we aim to conduct an analytical study of some of lumbar spine loading movements outlined in this study, using a musculoskeletal simulator and electromyography.

9.
J Cardiol Cases ; 26(2): 118-121, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35949574

RESUMEN

An autopsy case of Parkes-Weber syndrome presenting high-output heart failure in a patient who died at 52 years old, is reported. The patient had a tumor in the right buttock since childhood, that had grown up to a diameter of 40 cm diameter by the age of 43 years when he felt exertional dyspnea and was diagnosed as having high-output heart failure due to arteriovenous fistulas. Embolotherapy was attempted, which relieved the symptoms. After 4 years his heart failure deteriorated. We performed embolotherapy but his condition did not improve. He died 1.5 years later. The autopsy revealed the weight of the heart was 1040 g with abundant subendocardial and interstitial fibrosis. In this patient, the level of output had been over 16 L/min which lasted for nine years. The left ventricular ejection fraction (LVEF) decreased during the first five years. Each embolotherapy reduced the cardiac output (CO), which was achieved by a large decrease in heart rate (HR) and a small increase in stroke volume (SV) i.e. CO = HR × SV, and was reflected in the increase in LVEF. Learning objectives: •Parkes-Weber syndrome has occasionally extensive arteriovenous fistulas in the pelvis that show high-output heart failure.•Treatment of such cases is difficult, but embolotherapy has partial effects on improving hemodynamics.•A long-term high-output state induces interstitial myocardial fibrosis and collagenous subendocardial thickening.

10.
J Phys Ther Sci ; 34(4): 320-326, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35400837

RESUMEN

[Purpose] This study aimed to develop and validate a method for identifying factors that may cause a fall during the pre-impact fall period using wearable sensors. [Participants and Methods] The participants were 23 young people from the public data set (mean age, 23.4 years). Acceleration and angular velocity information obtained from sensors attached to the participant's waist was used to generate the pre-impact fall. The cause of the fall (slip, trip, fainting, get up, sit down) was then classified with and without the addition of activity of daily living data using three different support vector machine. In addition, we investigated the influence of lead time (0-2.0s) on accuracy. [Results] The quadratic and cubic support vector machine identified the activity of daily living and fall patterns more accurately than the linear support vector machine, and the cubic support vector machine was better for classification, although the difference was slight. The greatest accuracy for predicting the cause of the fall (87.9%) was obtained when the cubic support vector machine was used, activity of daily living was factored into the analysis, and the lead time was 0.25 sec. [Conclusion] Support vector machine can identify the cause of the fall during the pre-impact fall period. Appropriate individualized interventions may be designed based on the most likely cause of fall as identified by this analysis method.

11.
Kyobu Geka ; 75(2): 111-113, 2022 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-35249086

RESUMEN

We report a case of delayed hemolytic transfusion reaction (DHTR) after mitral valve replacement (MVR). A 67-year-old woman with a history of blood transfusion( BT) was admitted for MVR. Preoperative laboratory test proved to be negative for irregular antibodies except anti-Dia. She underwent MVR using a mechanical prosthesis and compatible blood products were transfused perioperatively. On post-operative day 13, she developed hemoglobinuria and anemia with elevated serum total bilirubin and lactic dehydrogenase levels. Transesophageal echocardiography showed trivial transvalvular leakage. Laboratory test successfuly identified another irregular antibody, anti-Jkb antibody. The patient had Jkb negative BT and did not need re-operation. Later, she recovered with no signs of hemolysis. Since anti-Jkb antibody gets undetectable within a few months, it is difficult to find out before surgery. As hemolysis following cardiac surgery is more commonly associated with prostheses and extracorporeal circulation than DHTR. Physicians should, however, be aware of this unusual complication especially in patients who underwent BT.


Asunto(s)
Anemia Hemolítica , Reacción a la Transfusión , Anciano , Anemia Hemolítica/etiología , Transfusión Sanguínea , Femenino , Hemólisis , Humanos , Isoanticuerpos , Válvula Mitral/cirugía , Reacción a la Transfusión/complicaciones
12.
Artículo en Inglés | MEDLINE | ID: mdl-35162362

RESUMEN

It is yet not known whether the variation in knee orthotics pressure would lead to changes in muscle activity during-sit-to-stand postural transition in patients with knee osteoarthritis (OA). Participants in this analytical study were patients with knee OA. The research design was a cross-sectional study. They were enrolled in the study through a sample of convenience method. The primary outcome measure was surface electromyography for measuring muscle activity while changing knee orthotics pressure during sit-to-stand motion. Data were summarized with mean and standard deviation while Friedman's test was performed for multiple comparison of variables, at a significance level of p = 0.05. Seven elderly patients with knee osteoarthritis (mean age 71.4 ± 11.8 years) participated in the study. Moderate orthotics (7.3 mmHg) led to a significant increase in the percentage maximum voluntary contraction (MVC) of tibialis anterior compared to that obtained without orthotics. Rectus femoris, vastus medialis, vastus lateralis, and biceps femoris tended to increase the % MVC with an increase in wearing pressure. It was therefore concluded that the muscle activity during sit-to-stand motion could be increased in patients with knee osteoarthritis by wearing flexible orthotics with varying pressure.


Asunto(s)
Osteoartritis de la Rodilla , Anciano , Anciano de 80 o más Años , Estudios Transversales , Electromiografía , Humanos , Persona de Mediana Edad , Músculo Esquelético/fisiología , Aparatos Ortopédicos
13.
Org Lett ; 24(1): 202-206, 2022 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-34904840

RESUMEN

The total synthesis of paclitaxel (Taxol) is described. Double Rubottom oxidation of the bis(silyl enol ether) derived from a tricarbocyclic diketone effectively installed a bridgehead olefin and C-5/C-13 hydroxy groups in a one-step operation. The novel Ag-promoted oxetane formation smoothly constructed the tetracyclic framework of paclitaxel.


Asunto(s)
Paclitaxel
14.
JACC Case Rep ; 3(17): 1863-1868, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34917969

RESUMEN

A man affected by hereditary hemorrhagic telangiectasia who had chronic severe hypoxemia is presented. This hypoxemia was synergistically caused by high-output heart failure due to severe hepatic shunts and multiple pulmonary arteriovenous shunts. The symptomatic combination is rare, and genetic testing showed a novel endoglin mutation. (Level of Difficulty: Advanced.).

15.
Phys Rev Lett ; 127(24): 241102, 2021 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-34951783

RESUMEN

High-quality optical resonant cavities require low optical loss, typically on the scale of parts per million. However, unintended micron-scale contaminants on the resonator mirrors that absorb the light circulating in the cavity can deform the surface thermoelastically and thus increase losses by scattering light out of the resonant mode. The point absorber effect is a limiting factor in some high-power cavity experiments, for example, the Advanced LIGO gravitational-wave detector. In this Letter, we present a general approach to the point absorber effect from first principles and simulate its contribution to the increased scattering. The achievable circulating power in current and future gravitational-wave detectors is calculated statistically given different point absorber configurations. Our formulation is further confirmed experimentally in comparison with the scattered power in the arm cavity of Advanced LIGO measured by in situ photodiodes. The understanding presented here provides an important tool in the global effort to design future gravitational-wave detectors that support high optical power and thus reduce quantum noise.

16.
J Phys Ther Sci ; 33(7): 537-539, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34219960

RESUMEN

[Purpose] To investigate the effects of a flexible brace, by analyzing whether its usage; the difference in wearing pressure could change the joint position sensation in healthy participants; and develop a flexible knee brace for patients with knee osteoarthritis. [Participants and Methods] The study included eight healthy males with 14 knee joints (mean age, 22.0 ± 3.1 years). To measure joint position sense, an "angle reproduction test" was performed in three experimental conditions: 1) participants not wearing the brace, 2) the brace was secured with an appropriate force, and 3) the brace was fully secured using hook-and-loop fasteners. [Results] No significant difference was observed among groups comprising of those not wearing, those wearing with the standard force, and those wearing with the tight force. When the maximum hook-and-loop fastener was squeezed, the sensory error in joint position was maximized at both 30° and 60° flexion. [Conclusion] Joint position sense improvement was confirmed to be poor by orthosis, and an error occurred in the joint position sense by increasing the wearing pressure in orthosis. In future, measurements should be performed on patients with knee osteoarthritis who have decreased joint position sense and verify the effect of different wearing pressures verified.

17.
J Oral Sci ; 63(3): 236-241, 2021 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-34078767

RESUMEN

PURPOSE: This study aimed to clarify the positional relationship between the crown contour and pulp chamber of protostylids using three-dimensional reconstructed images. METHODS: Fourteen molars with protostylids from Japanese subjects were subjected to micro-computed tomography. The external surface configurations of the teeth and pulp chambers were reconstructed. Hard tissue thicknesses in appointed buccal areas were measured on the reconstructed images. RESULTS: Well-developed protostylids exhibited pulp-prominences above or at the cervical line level. Those that were moderately developed exhibited bulges of the pulp chamber subjacent to the protostylids. Ten of the 14 teeth had prominences in the crown pulp above or at the cervical line level. In addition, 13 teeth exhibited pulp chamber bulges surrounding the lower tooth trunk. No significant differences were apparent in the buccal horizontal thickness of the hard tissue between the protostylids with pulp chamber prominences and the protostylids without pulp chamber prominences at the cervical line level. CONCLUSION: Pulp chamber configurations subjacent to protostylids vary based on the development of the traits of the protostylids. Minimum possible taper should be applied during standard vital tooth preparations, as reduced residual dentin thickness is predicted in well- and moderately developed protostylids.


Asunto(s)
Cavidad Pulpar , Diente Molar , Humanos , Corona del Diente/diagnóstico por imagen , Raíz del Diente , Microtomografía por Rayos X
18.
PLoS One ; 15(11): e0237279, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33166293

RESUMEN

The spread of wearable watch devices with photoplethysmography (PPG) sensors has made it possible to use continuous pulse wave data during daily life. We examined if PPG pulse wave data can be used to detect sleep apnea, a common but underdiagnosed health problem associated with impaired quality of life and increased cardiovascular risk. In 41 patients undergoing diagnostic polysomnography (PSG) for sleep apnea, PPG was recorded simultaneously with a wearable watch device. The pulse interval data were analyzed by an automated algorithm called auto-correlated wave detection with adaptive threshold (ACAT) which was developed for electrocardiogram (ECG) to detect the cyclic variation of heart rate (CVHR), a characteristic heart rate pattern accompanying sleep apnea episodes. The median (IQR) apnea-hypopnea index (AHI) was 17.2 (4.4-28.4) and 22 (54%) subjects had AHI ≥15. The hourly frequency of CVHR (Fcv) detected by the ACAT algorithm closely correlated with AHI (r = 0.81), while none of the time-domain, frequency-domain, or non-linear indices of pulse interval variability showed significant correlation. The Fcv was greater in subjects with AHI ≥15 (19.6 ± 12.3 /h) than in those with AHI <15 (6.4 ± 4.6 /h), and was able to discriminate them with 82% sensitivity, 89% specificity, and 85% accuracy. The classification performance was comparable to that obtained when the ACAT algorithm was applied to ECG R-R intervals during the PSG. The analysis of wearable watch PPG by the ACAT algorithm could be used for the quantitative screening of sleep apnea.


Asunto(s)
Algoritmos , Frecuencia Cardíaca/fisiología , Monitoreo Ambulatorio/instrumentación , Polisomnografía/instrumentación , Calidad de Vida , Síndromes de la Apnea del Sueño/diagnóstico , Dispositivos Electrónicos Vestibles/estadística & datos numéricos , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Curva ROC
19.
Clin Case Rep ; 8(9): 1663-1665, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32983472

RESUMEN

Current evidence suggests that the choice between valve-in-valve transcatheter aortic valve implantation and reoperative aortic valve replacement should be based on multiple factors.

20.
Kyobu Geka ; 73(8): 586-589, 2020 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-32879285

RESUMEN

The patient was a 74-year-old male who had undergone intravesical Bacillus Calmette-Guérin(BCG) instillation therapy for bladder cancer. He visited our hospital with chief complaints of fever and abdominal pain. Abdominal aortic aneurysmal rupture and iliopsoas muscle abscess were confirmed by computed tomography( CT). We performed semi-emergency surgery, including replacement of the abdominal aorta with a synthetic graft, iliopsoas abscess debridement, and omentopexy. A rifampicin-bonded synthetic graft was used because of the possibility of tuberculous involvement after BCG instillation therapy. Examination of the tissues collected during surgery were positive for tuberculosis deoxyribonucleic acid (DNA) in a polymerase chain reaction (PCR), and showed multiple giant cell granulomas with caseous necrosis, which both strongly suggested involvement of tuberculosis. Therefore, 4 types of antituberculous drugs were administered for 40 days. This case shows that an infective aneurysm should be suspected when fever and abdominal pain develop after intravesical BCG instillation therapy.


Asunto(s)
Aneurisma de la Aorta Abdominal , Rotura de la Aorta , Tuberculosis , Neoplasias de la Vejiga Urinaria , Administración Intravesical , Anciano , Vacuna BCG/uso terapéutico , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...