Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
1.
Jpn J Radiol ; 42(2): 126-144, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37626168

RESUMEN

Dynamic chest radiography (DCR) is a novel functional radiographic imaging technique that can be used to visualize pulmonary perfusion without using contrast media. Although it has many advantages and clinical utility, most radiologists are unfamiliar with this technique because of its novelty. This review aims to (1) explain the basic principles of lung perfusion assessment using DCR, (2) discuss the advantages of DCR over other imaging modalities, and (3) review multiple specific clinical applications of DCR for pulmonary vascular diseases and compare them with other imaging modalities.


Asunto(s)
Enfermedades Pulmonares , Enfermedades Vasculares , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Pulmón/irrigación sanguínea , Radiografía , Medios de Contraste , Enfermedades Vasculares/diagnóstico por imagen , Radiografía Torácica/métodos
2.
J Comput Assist Tomogr ; 48(1): 77-84, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37574664

RESUMEN

OBJECTIVE: The purpose of this study is to evaluate the efficacy of deep learning reconstruction (DLR) on low-tube-voltage computed tomographic angiography (CTA) for transcatheter aortic valve implantation (TAVI). METHODS: We enrolled 30 patients who underwent TAVI-CT on a 320-row CT scanner. Electrocardiogram-gated coronary CTA (CCTA) was performed at 100 kV, followed by nongated aortoiliac CTA at 80 kV using a single bolus of contrast material. We used hybrid-iterative reconstruction (HIR), model-based IR (MBIR), and DLR to reconstruct these images. The contrast-to-noise ratios (CNRs) were calculated. Five-point scales were used for the overall image quality analysis. The diameter of the aortic annulus was measured in each reconstructed image, and we compared the interobserver and intraobserver agreements. RESULTS: In the CCTA, the CNR and image quality score for DLR were significantly higher than those for HIR and MBIR ( P < 0.01). In the aortoiliac CTA, the CNR for DLR was significantly higher than that for HIR ( P < 0.01) and significantly lower than that for MBIR ( P ≤ 0.02). The image quality score for DLR was significantly higher than that for HIR ( P < 0.01). No significant differences were observed between the image quality scores for DLR and MBIR. The measured aortic annulus diameter had high interobserver and intraobserver agreement regardless of the reconstruction method (all intraclass correlation coefficients, >0.89). CONCLUSIONS: In low tube voltage TAVI-CT, DLR provides higher image quality than HIR, and DLR provides higher image quality than MBIR in CCTA and is visually comparable to MBIR in aortoiliac CTA.


Asunto(s)
Aprendizaje Profundo , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Angiografía por Tomografía Computarizada/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios de Factibilidad , Dosis de Radiación , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
3.
J Appl Clin Med Phys ; 25(1): e14222, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38011586

RESUMEN

PURPOSE: Dynamic chest radiography (DCR) is a novel imaging technique used to noninvasively evaluate pulmonary perfusion. However, the standard DCR protocol, which is roughly adapted to the patient's body size, occasionally causes over- or underexposure, which could influence clinical evaluation. Therefore, we proposed a refined protocol by increasing the number of patient body mass index (BMI) categories from three to seven groups and verified its usefulness by comparing the image sensitivity indicators (S-values) and entrance surface doses (ESDs) of the conventional protocol with those of our refined protocol. METHODS: This retrospective observational study included 388 datasets (standing position, 224; supine position, 164) for the conventional protocol (December 2019-April 2021) and 336 datasets (standing position, 233; supine position, 103) for the refined protocol (June-November 2021). The conventional protocol (BMI-3 protocol) divided the patients into three BMI groups (BMI < 17, 17≤BMI < 25, and BMI ≥ 25 kg/m2 ), whereas the refined protocol (BMI-7 protocol) divided the patients into seven BMI groups (BMI < 17, 17 ≤ BMI < 20, 20 ≤ BMI < 23, 23 ≤ BMI < 26, 26 ≤ BMI < 29, 29 ≤ BMI < 32, and BMI ≥ 32 kg/m2 ). The coefficients of variation (CVs) for the S-values and ESDs acquired using the two protocols were compared. RESULTS: The CVs of the S-values in the BMI-7 protocol group were significantly lower than those in the BMI-3 protocol group for the standing (28.8% vs. 16.7%; p < 0.01) and supine (24.5% vs. 17.7%; p < 0.01) positions. The ESDs of patients scanned using the BMI-7 protocol were significantly lower than those scanned using the BMI-3 protocol in the standing (1.3 vs. 1.1 mGy; p < 0.01) and supine positions (2.5 vs. 1.6 mGy; p < 0.01), although the mean BMI of the two groups were similar. CONCLUSION: We introduced the BMI-7 protocol and demonstrated its standardized image quality and reduced radiation exposure in patients undergoing DCR.


Asunto(s)
Exposición a la Radiación , Humanos , Perfusión , Dosis de Radiación , Radiografía , Cintigrafía , Estudios Retrospectivos
4.
5.
Acad Radiol ; 2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38008645

RESUMEN

RATIONALE AND OBJECTIVES: Dual-energy subtraction (DES) imaging constitutes a technique that has demonstrated efficacy in enhancing the detectability of pulmonary nodules on chest radiographs. However, a simple and quantitative methodology for evaluating the clinical image quality of DES images is currently lacking. The objective of this study was to investigate the applicability of contrast-detail (C-D) phantom analysis to the visual clinical image quality evaluation of chest DES images. MATERIALS AND METHODS: We employed a custom-made phantom incorporating the C-D phantom and a multipurpose anthropomorphic adult chest phantom. Two phantom sizes were utilized to simulate standard- and large-bodied adult patients for each phantom. The custom-made phantom images were scored automatically using dedicated software, yielding an inverse image quality figure (IQFinv) value. The multipurpose anthropomorphic adult chest phantom was employed in a visual grading analysis (VGA) study that was conducted by two experienced radiologists and five radiological technologists. Each nodule placed in the chest phantom image was rated on a 4-point Likert scale. RESULTS: A statistically significant correlation was observed between the VGA scores of the seven observers and the obtained IQFinv values. CONCLUSION: The findings of this study suggest that DES image analysis of the C-D phantom possesses the potential to be utilized for the evaluation of clinical DES image quality based on chest lesion detectability.

6.
Interv Cardiol Clin ; 12(3): 367-380, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37290840

RESUMEN

Chronic thromboembolic pulmonary hypertension (CTEPH) is a late complication of acute pulmonary thromboembolism owing to incomplete clot dissolution in pulmonary artery. Pulmonary endarterectomy is the first-line treatment for CTEPH. However, 40% of patients are not candidates for surgery because of distal lesions or age. Balloon pulmonary angioplasty (BPA), a catheter-based intervention, is increasingly being used worldwide for treating inoperable CTEPH. Previous BPA strategy had a major concern of reperfusion pulmonary edema as a complication. However, recent refined strategies promise safe and effective BPA. Five-year survival rate after BPA is 90% for inoperable CTEPH, comparable with that of operable CTEPH.


Asunto(s)
Angioplastia de Balón , Hipertensión Pulmonar , Embolia Pulmonar , Humanos , Hipertensión Pulmonar/etiología , Enfermedad Crónica , Embolia Pulmonar/complicaciones , Embolia Pulmonar/cirugía , Arteria Pulmonar/cirugía
8.
Clin Imaging ; 96: 38-43, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36773531

RESUMEN

PURPOSE: To assess the usefulness of amide proton transfer (APT) imaging to predict the biological status of breast cancers. METHOD: Sixty-six patients (age range 31-85 years, mean 58.9 years) with histopathologically proven invasive ductal carcinomas of 2 cm or larger in diameter were included in this study. 3D APT weighted imaging was conducted on a 3 T scanner. Mean APT signal intensity (SI) was analyzed in relation to biological subtypes, Ki-67 labeling index, and nuclear grades (NGs). RESULTS: The triple-negative (TN) cancers (n = 10; 2.75 ± 0.42%) showed significantly higher APT SI than the luminal type cancers (n = 48; 1.74 ± 0.83) and HER2 cancers (n = 8; 1.83 ± 0.21) (P = 0.0007, 0.03). APT SI had weakly positive correlation with the Ki-67 labeling index (r = 0.38, P = 0.002). The mean APT SIs were significantly higher for high-Ki-67 (>30%) (n = 31; 2.25 ± 0.70) than low-Ki-67 (≤30%) cancers (n = 35; 1.60 ± 0.79) (P = 0.0007). There was no significant difference in the APT SIs between NG 1-2 (n = 31; 1.71 ± 0.84) and NG 3 (n = 35; 2.08 ± 0.76%) cancers (P = 0.06). CONCLUSIONS: TN and high-Ki-67 breast cancers showed high APT SIs. APT imaging can help to predict the biological status of breast cancers.


Asunto(s)
Neoplasias Encefálicas , Neoplasias de la Mama , Humanos , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Femenino , Imagen por Resonancia Magnética/métodos , Protones , Antígeno Ki-67 , Amidas , Neoplasias Encefálicas/patología
9.
Jpn J Radiol ; 41(7): 733-740, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36729189

RESUMEN

PURPOSE: To investigate the efficacy of virtual monochromatic spectral computed tomography imaging (VMI) in the preoperative evaluation for intraductal spread of breast cancer. MATERIALS AND METHODS: Twenty-four women who underwent spectral CT and were pathologically diagnosed with ductal carcinoma with a ≥ 2-cm noninvasive component were retrospectively enrolled in Group 1. Twenty-two women with 22 lesions pathologically diagnosed with ductal carcinoma in situ or microinvasive carcinoma were enrolled in Group 2. We compared the contrast-to-noise ratios (CNRs) of the lesions on conventional 120-kVp CT images and 40-keV VMIs in Group 1. Two board-certified radiologists measured the maximum diameters of enhancing areas on 120-kVp CT, 40-keV VMI, and MRI in Group 2 and compared with histopathological sizes. RESULTS: The quantitative assessment of Group 1 revealed that the mean ± SD of the CNRs in the 40-keV images were significantly greater than those in the 120-kVp images (5.5 ± 1.9 vs. 3.6 ± 1.5, p < 0.0001). The quantitative assessment of Group 2 demonstrated that the lesion size observed in the conventional 120-kVp CT images by both readers was significantly underestimated as compared to the histopathological size (p = 0.017, 0.048), whereas both readers identified no significant differences between the lesion size measured on 40-keV VMI and the histopathological data. In a comparison with MRI, 40-keV VMI provided measurement within a 10-mm error range in more lesions as compared to the conventional 120-kVp CT. CONCLUSION: VMI improves the evaluation of intraductal spread and is useful for the preoperative evaluations of breast cancer.


Asunto(s)
Neoplasias de la Mama , Humanos , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Imagen por Resonancia Magnética , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
10.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-36661919

RESUMEN

Pulmonary regurgitation (PR) is a risk factor for sudden cardiac death in adult patients with repaired tetralogy of Fallot (TOF). However, transthoracic echocardiography (TTE) cannot fully visualize the pulmonary valve (PV) and PR. We investigated whether intracardiac echocardiography (ICE) could visualize the PV and PR better than TTE. Thirty adult patients with TOF (mean age 33 ± 15 years) scheduled for cardiac catheterization underwent ICE. The visualization of PV and the severity of PR were classified into three grades. ICE depicted the PV better than TTE (ICE vs. TTE: not visualized, partially visualized, and fully visualized: n = 1 [3%], n = 13 [43%], and n = 16 [53%] vs. n = 14 [47%], n = 13 [43%], and n = 3 [10%], p < 0.001). Especially in patients after pulmonary valve replacement (PVR), the PV was more fully visualized by ICE. The assessment of PR by TTE underestimated the severity of PR in comparison to cardiac magnetic resonance imaging (MRI) (severe PR: 8 [28%] vs. 22 [76%], p = 0.004), while there was no discrepancy between the results of ICE and MRI (21 [72%] vs. 22 [76%], p = 1.000). In comparison to TTE, ICE can safely provide better visualization of the PV and PR in adults with TOF, especially in patients who have undergone PVR.

11.
Radiology ; 306(3): e220908, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36346313

RESUMEN

Background While current guidelines require lung ventilation-perfusion (V/Q) scanning as the first step to diagnose chronic pulmonary embolism in pulmonary hypertension (PH), its use may be limited by low availability and/or exposure to ionizing radiation. Purpose To compare the performance of dynamic chest radiography (DCR) and lung V/Q scanning for detection of chronic thromboembolic PH (CTEPH). Materials and Methods Patients with PH who underwent DCR and V/Q scanning in the supine position from December 2019 to July 2021 were retrospectively screened. The diagnosis of CTEPH was confirmed with right heart catheterization and invasive pulmonary angiography. Observer tests were conducted to evaluate the diagnostic accuracy of DCR and V/Q scanning. The lungs were divided into six areas (upper, middle, and lower for both) in the anteroposterior image, and the number of lung areas with thromboembolic perfusion defects was scored. Diagnostic performance was compared between DCR and V/Q scanning using the area under the receiver operating characteristic curve. Agreement between the interpretation of DCR and that of V/Q scanning was assessed using the Cohen kappa coefficient and percent agreement. Results A total of 50 patients with PH were analyzed: 29 with CTEPH (mean age, 64 years ± 15 [SD]; 19 women) and 21 without CTEPH (mean age, 61 years ± 22; 14 women). The sensitivity, specificity, and accuracy of DCR were 97%, 86%, and 92%, respectively, and those of V/Q scanning were 100%, 86%, and 94%, respectively. Areas under the receiver operating characteristic curve for DCR and V/Q scanning were 0.92 (95% CI: 0.79, 0.97) and 0.93 (95% CI: 0.78, 0.98). Agreement between the consensus interpretation of DCR and that of V/Q scanning was substantial (κ = 0.79 [95% CI: 0.61, 0.96], percent agreement = 0.9 [95% CI: 0.79, 0.95]). Conclusion Dynamic chest radiography had similar efficacy to ventilation-perfusion scanning in the detection of chronic thromboembolic pulmonary hypertension. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Wandtke and Koproth-Joslin in this issue.


Asunto(s)
Hipertensión Pulmonar , Embolia Pulmonar , Humanos , Femenino , Persona de Mediana Edad , Hipertensión Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Enfermedad Crónica , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Angiografía/métodos
12.
J Thorac Dis ; 15(12): 7155-7158, 2023 Dec 30.
Artículo en Inglés | MEDLINE | ID: mdl-38249855
13.
Radiol Cardiothorac Imaging ; 4(4): e220086, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36059380

RESUMEN

Supplemental material is available for this article.

14.
MAGMA ; 35(6): 911-921, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35585430

RESUMEN

OBJECTIVE: We propose a deep learning-based fully automatic right ventricle (RV) segmentation technique that targets radially reconstructed long-axis (RLA) images of the center of the RV region in routine short axis (SA) cardiovascular magnetic resonance (CMR) images. Accordingly, the purpose of this study is to compare the accuracy of deep learning-based fully automatic segmentation of RLA images with the accuracy of conventional deep learning-based segmentation in SA orientation in terms of the measurements of RV strain parameters. MATERIALS AND METHODS: We compared the accuracies of the above-mentioned methods in RV segmentations and in measuring RV strain parameters by Dice similarity coefficients (DSCs) and correlation coefficients. RESULTS: DSC of RV segmentation of the RLA method exhibited a higher value than those of the conventional SA methods (0.84 vs. 0.61). Correlation coefficient with respect to manual RV strain measurements in the fully automatic RLA were superior to those in SA measurements (0.5-0.7 vs. 0.1-0.2). DISCUSSION: Our proposed RLA realizes accurate fully automatic extraction of the entire RV region from an available CMR cine image without any additional imaging. Our findings overcome the complexity of image analysis in CMR without the limitations of the RV visualization in echocardiography.


Asunto(s)
Aprendizaje Profundo , Ventrículos Cardíacos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Magnética , Procesamiento de Imagen Asistido por Computador/métodos , Reproducibilidad de los Resultados
15.
Jpn J Radiol ; 40(8): 781-790, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35396666

RESUMEN

PURPOSE: We investigated the effects of the heart rate (HR) on the motion artifact in coronary computed tomography angiography (CCTA) with ultra-high-resolution-CT (U-HRCT), and we clarified the upper limit of optimal HR in CCTA with U-HRCT in a comparison with conventional-resolution-CT (CRCT) on a cardiac phantom and in patients with CCTA. MATERIALS AND METHODS: A pulsating cardiac phantom equipped with coronary models was scanned at static and HR simulations of 40-90 beats/min (bpm) at 10-bpm intervals using U-HRCT and CRCT, respectively. The sharpness and lumen diameter of the coronary model were quantitatively compared between U-HRCT and CRCT stratified by HR in the phantom study. We also assessed the visual inspections of clinical images in CCTA with U-HRCT. RESULTS: At the HRs ≤ 60 bpm, the error of the lumen diameter of the U-HRCT tended to be smaller than that of the CRCT. However, at the HRs > 60 bpm, the inverse was shown. For the image sharpness, the U-HRCT was significantly superior to the CRCT (p < 0.05). In the visual assessment, the scores were negatively correlated with HRs in patients (Spearman r = - 0.71, p < 0.01). A receiver-operating characteristic analysis revealed the HR of 61 bpm as the optimal cutoff of the non-diagnostic image quality, with an area under the curve of 0.87, 95% sensitivity, and 71% specificity. CONCLUSION: At HRs ≤ 60 bpm, U-HRCT was more accurate in the imaging of coronary arteries than CRCT. The upper limit of the optimal HR in CCTA with U-HRCT was approx. 60 bpm.


Asunto(s)
Angiografía por Tomografía Computarizada , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Frecuencia Cardíaca/fisiología , Humanos , Rotación , Tomografía Computarizada por Rayos X/métodos
17.
Phys Med ; 95: 176-181, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35219067

RESUMEN

PURPOSE: Recently developed and commercialized dual-layer flat panel detectors (DL-FPDs) with two indirect scintillators are capable of acquiring dual-energy X-ray images. However, in clinical practice, they are utilized to perform conventional radiography using diagnostic X-rays with a wide energy spectrum. The two layers of the DL-FPD may affect the obtained image quality, even when only using one layer for conventional image acquisition, and these effects are yet to be substantiated. Therefore, in this study, we quantitatively evaluated the image quality of a conventional chest radiography using DL-FPD and visually verified the characteristics of the chest anthropomorphic phantom images. METHODS: The physical characteristics of the system were evaluated using the pre-sampled modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), for beam quality RQA 7 and RQA 9. In addition, the subjective visibility of the anthropomorphic chest phantom and simple objects images were compared with those of a conventional single-layer flat-panel detector (SL-FPD). RESULTS: No significant differences were found in the MTF between the SL-FPD and DL-FPD images. In addition, a higher DQE was observed at some exposure doses and in the high spatial frequency regions wherein NNPSs were lower for DL-FPD than for SL-FPD. Furthermore, no significant differences were found in the subjective visibility of the chest phantoms in each system. CONCLUSIONS: We concluded that the image quality of the conventional radiography acquired with DL-FPD is comparable to or better than that of the SL-FPD.


Asunto(s)
Intensificación de Imagen Radiográfica , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Radiografía
18.
Int J Cardiovasc Imaging ; 38(10): 2219-2225, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37726459

RESUMEN

To investigate the usefulness of high-resolution systolic T1 mapping using compressed sensing for right ventricular (RV) evaluation. Phantoms and normal volunteers were scanned at 3 T by using a high-resolution (HR) modified look-locker inversion recovery (MOLLI) pulse sequence and a conventional MOLLI pulse sequence. The T1 values of the left ventricular (LV) and RV myocardium and blood pool were measured for each sequence. T1 values of HR-MOLLI and MOLLI sequences were compared in the LV myocardium, blood pool, and RV myocardium. The T1 values of HR-MOLLI and MOLLI showed good agreement in both phantoms and the LV myocardium and blood pool of volunteers. However, there was a significant difference between HR-MOLLI and MOLLI in the RV myocardium (1258 ± 52 ms vs. 1327 ± 73 ms; P = 0.0005). No significant difference was observed between the T1 value of RV and that of LV (1217 ± 32 ms) in HR-MOLLI, whereas the T1 value of RV was significantly higher than that of LV in MOLLI (P < 0.0001). The interclass correlation coefficients of intraobserver variabilities from HR-MOLLI and MOLLI were 0.919 and 0.804, respectively, and the interobserver variabilities from HR-MOLLI and MOLLI were 0.838 and 0.848, respectively. Assessment of RV myocardium by using HR systolic T1 mapping was superior to the conventional MOLLI sequence in terms of accuracy and reproducibility.


Asunto(s)
Ventrículos Cardíacos , Voluntarios , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Fantasmas de Imagen
19.
Eur J Radiol ; 144: 109980, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34601323

RESUMEN

PURPOSE: To evaluate the usefulness of magnetic resonance imaging (MRI) to differentiate basal cell adenomas (BCAs) from other parotid tumors. METHOD: A total of 136 patients with histologically proven parotid gland tumors (13 BCAs, 66 pleomorphic adenomas [PAs], 30 Warthin tumors [WTs], and 27 parotid cancers [PCs]) who underwent a cervical MRI study between December 2011 and March 2019 were retrospectively enrolled. The MRI findings of the tumors were evaluated by two board-certified radiologists. RESULTS: All 13 of the BCAs showed smooth margins, while 19 of the 27 PCs showed irregular margins (p < 0.0001). Eleven BCAs had some cystic components, and five were cyst-dominant. The BCAs had significantly more cystic components than the PAs (p = 0.0077). The mean apparent diffusion coefficient (ADC) value of the BCAs was 1.21 ± 0.20 × 10-3 mm2/sec, which was equivalent to that of the PCs (1.12 ± 0.25 × 10-3 mm2/sec, p = 0.76), significantly lower than that of the PAs (1.61 ± 0.32 × 10-3 mm2/sec, p < 0.0001), and significantly higher than that of the WTs (0.81 ± 0.19 × 10-3 mm2/sec, p = 0.0004). The plateau time-intensity curve (TIC) was the most common type for both BCAs and PCs, seen in 8 of 12 BCAs and 21 of 26 PCs, with no significant difference between these groups (p = 0.34). CONCLUSIONS: BCA should be considered a possibility when a parotid lesion has smooth margins with an entire capsule and includes a cystic component, even if the TIC and diffusion-weighted MR images suggest a malignant pattern.


Asunto(s)
Adenoma , Neoplasias de la Parótida , Diagnóstico Diferencial , Imagen de Difusión por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética , Glándula Parótida/diagnóstico por imagen , Neoplasias de la Parótida/diagnóstico por imagen , Estudios Retrospectivos
20.
Sci Rep ; 11(1): 18879, 2021 09 23.
Artículo en Inglés | MEDLINE | ID: mdl-34556756

RESUMEN

We measured right ventricular (RV) strain by applying a novel postprocessing technique to conventional short-axis cine magnetic resonance imaging in the repaired tetralogy of Fallot (TOF) and investigated whether pulmonary valve replacement (PVR) changes the RV strain. Twenty-four patients with repaired TOF who underwent PVR and 16 healthy controls were enrolled. Global maximum and minimum principal strains (GPSmax, GPSmin) and global circumferential and longitudinal strains (GCS, GLS) were measured from short-axis cine images reconstructed radially along the long axis. Strain parameters before and after PVR were compared using paired t-tests. One-way ANOVA with Tukey post-hoc analysis was used for comparisons between the before and after PVR groups and the control group. There were no differences in strain parameters before and after PVR. The GPSmax before PVR was lower than that in the control group (P = 0.002). Before and after PVR, GCSs were higher and GLSs were lower than those in the control group (before and after GCSs: P = 0.002 for both, before and after GLSs: P < 0.0001 and P = 0.0003). RV strains from radially reconstructed short-axis cine images revealed unchanged myocardial motion after PVR. When compared to the control group, changes in GCS and GLS in TOF patients before and after PVR might be due to RV remodeling.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/cirugía , Tetralogía de Fallot/cirugía , Adolescente , Adulto , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Insuficiencia de la Válvula Pulmonar/fisiopatología , Estudios Retrospectivos , Tetralogía de Fallot/fisiopatología , Resultado del Tratamiento , Función Ventricular Derecha/fisiología , Remodelación Ventricular/fisiología , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...