Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
1.
J Arrhythm ; 40(3): 520-526, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38939774

RESUMEN

Background: Hyperuricemia (HU) has been reported to be associated with a high incidence of atrial fibrillation (AF). However, the relationship between HUA and recurrent AF after catheter ablation (CA) is unclear. Methods: Four hundred consecutive AF patients (paroxysmal/persistent AF [PAF/PsAF]: 200/200) who underwent the initial CA were retrospectively enrolled. HU was defined as serum uric acid (SUA) level >7.0 mg/dL. We measured SUA levels 1 day before (pre-CA) and 1 month after CA (post-CA). A second-generation 28 mm cryoballoon was used for pulmonary vein isolation (PVI) for PAF, while PVI plus linear ablation (roof and mitral isthmus lines) by radiofrequency catheter was conducted for PsAF. Results: During 57 ± 24 months of follow-up, AF recurred in 16% and 42% in PAF and PsAF patients (p < .0001). Pre-CA SUA level in PsAF was significantly higher than that in PAF (6.5 ± 1.3 vs. 5.8 ± 1.3 mg/dL, p < .001). SUA level was significantly decreased after CA in both PAF and PsAF (5.8 ± 1.3 vs. 5.6 ± 1.3 mg/dL; p < .01 and 6.5 ± 1.3 vs. 6.1 ± 1.2 mg/dL; p < .0001, respectively). The association between pre-/post-CA HU and recurrent AF was not identified in PAF, while the incidence of post-CA HU was significantly higher in patients with recurrent AF than those without in PsAF (36% vs. 15%, p < .001). In multivariable analysis, longer AF duration and the presence of post-CA HU were identified as independent predictors of AF recurrence in PsAF (OR:1.01, 95%CI:1.003-1.011, p = .0001 and OR:2.77, 95%CI:1.333-5.755, p = .007, respectively). Conclusions: SUA level was significantly higher in PsAF than PAF patients. The presence of post-CA HU was strongly related to AF recurrence in PsAF patients.

3.
Pacing Clin Electrophysiol ; 47(3): 437-439, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-37260106

RESUMEN

We report a case of atrial fibrillation (AF) recurrence after pulmonary vein isolation, which patient had AF trigger in the superior vena cava (SVC) near the sinus node (SN). The ultra-high-resolution mapping revealed that SN located within the SVC and the atrial activation from the SN to SVC propagated in both septal and lateral direction, then upward with circumventing the spontaneous conduction block identified just above and lateral SN (upper hemisphere). We successfully isolated SVC including the ectopic origin at the same level as the SN by utilizing the spontaneous conduction block line around the SN without any complication.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Vena Cava Superior/cirugía , Fibrilación Atrial/cirugía , Nodo Sinoatrial , Atrios Cardíacos , Bloqueo Cardíaco , Venas Pulmonares/cirugía
5.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37258224

RESUMEN

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estudios Transversales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Rayos Láser
8.
BMJ Open ; 13(2): e068894, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36792334

RESUMEN

INTRODUCTION: Data are lacking on the extent to which patients with non-valvular atrial fibrillation (AF) who are aged ≥80 years benefit from ablation treatment. The question pertains especially to patients' postablation quality of life (QoL) and long-term clinical outcomes. METHODS AND ANALYSIS: We are initiating a prospective, registry-based, multicentre observational study that will include patients aged ≥80 years with non-valvular AF who choose to undergo treatment by catheter ablation and, for comparison, such patients who do not choose to undergo ablation (either according to their physician's advice or their own preference). Study subjects are to be enrolled from 52 participant hospitals and three clinics located throughout Japan from 1 June 2022 to 31 December 2023, and each will be followed up for 1 year. The planned sample size is 660, comprising 220 ablation group patients and 440 non-ablation group patients. The primary endpoint will be the composite incidence of stroke/transient ischaemic attack (TIA) or systemic embolism (SE), another cardiovascular event, major bleeding and/or death from any cause. Other clinical events such as postablation AF recurrence, a fall or bone fracture will be recorded. We will collect standard clinical background information plus each patient's Clinical Frailty Scale score, AF-related symptoms, QoL (Five-Level Version of EQ-5D) scores, Mini-Mental State Examination (optional) score and laboratory test results, including measures of nutritional status, on entry into the study and 1 year later, and serial changes in symptoms and QoL will also be secondary endpoints. Propensity score matching will be performed to account for covariates that could affect study results. ETHICS AND DISSEMINATION: The study conforms to the Declaration of Helsinki and the Ethical Guidelines for Clinical Studies issued by the Ministry of Health, Labour and Welfare, Japan. Results of the study will be published in one or more peer-reviewed journals. TRIAL REGISTRATION NUMBER: UMIN000047023.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Anciano , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Calidad de Vida , Estudios Prospectivos , Esperanza de Vida Saludable , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
9.
J Cardiol Cases ; 27(1): 16-18, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36618840

RESUMEN

An 81-year-old woman with arrhythmogenic right ventricular cardiomyopathy underwent catheter ablation for atrial fibrillation and atrial flutter. Hypoxemia refractory to the administration of oxygen was seen after transseptal puncture. Transthoracic echocardiography revealed right to left shunt via an iatrogenic atrial septal defect (IASD) that was increased by tricuspid regurgitation flow. Her hypoxemia improved after IASD occlusion with the inflation of a venogram balloon catheter. Emergent surgical IASD closure was successfully performed. IASD after transseptal puncture for atrial fibrillation ablation infrequently causes severe complications that require emergent repair. Learning objective: Some cases requiring iatrogenic atrial septal defect (IASD) closure after atrial fibrillation (AF) ablation have been reported. We describe the case of an arrhythmogenic right ventricular cardiomyopathy patient with right to left shunt via an IASD which required emergent surgical repair after AF ablation. Right to left shunt after trans-septal puncture is rare, however it can be an emergent life-threatening complication. IASD occlusion with venogram balloon catheter is helpful for the diagnosis and the short-term solution.

10.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36194289

RESUMEN

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Congelación , Estudios Transversales , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento
11.
Circ J ; 86(8): 1229-1236, 2022 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-35786690

RESUMEN

BACKGROUND: Pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is rare; however, it remains a serious complication. PV angioplasty is reportedly an effective therapy; however, a dedicated device for PV angioplasty has not been developed, and the detailed procedural methods remain undetermined. This study describes the symptoms, indications, treatment strategies, and long-term outcomes for PV stenosis after AF ablation.Methods and Results: This study retrospectively analyzed 7 patients with PV stenosis after catheter ablation for AF and who had undergone PV angioplasty at our hospital during 2015-2021. PV stenosis occurred in the left superior (5 patients) and left inferior (2 patients) PV. Six patients had hemoptysis, chest pain, and dyspnea. Seven de novo lesions were treated using balloon angioplasty (BA) (3 patients), a bare metal stent (BMS) (3 patients), and a drug-coated balloon (DCB) (1 patient). The restenosis rate was 42.9% (n=3; 2 patients in the BA group and 1 patient in the DCB group). The repeat treatment rate was 28.6% (2 patients in the BA group). Stenting was performed as repeat treatment. One patient with subsequent repeat restenosis development underwent BA. Ten PV angioplasties were performed; there were no major complications. CONCLUSIONS: Regarding PV angioplasty after ablation therapy for AF, stenting showed superior long-term PV patency than BA alone; therefore, it should be considered as a standard first-line approach.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Estenosis de Vena Pulmonar , Angioplastia/efectos adversos , Angioplastia/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Constricción Patológica/complicaciones , Humanos , Venas Pulmonares/cirugía , Estudios Retrospectivos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estenosis de Vena Pulmonar/terapia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35842800

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Bradicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Síndrome del Seno Enfermo/terapia , Taquicardia/diagnóstico , Taquicardia/cirugía , Resultado del Tratamiento
13.
Int J Cardiol Heart Vasc ; 40: 101020, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35434257

RESUMEN

Background: It was previously reported, based on a retrospective study, that preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of asymptomatic cerebral embolism (ACE). The present study aims to compare the incidence of ACE between a conventional and pre-inflation method during cryoballoon ablation in a prospective randomized controlled study. Methods: A total of 98 atrial fibrillation patients were enrolled and randomized into conventional and pre-inflation groups. Patients in the pre-inflation group received balloon massaging with preliminary extracorporeal balloon inflation in saline water before the cryoballoon was inserted into the body. Results: The baseline characteristics were similar between the two groups. Post-procedural 3-Tesla MRI revealed CE in 27.6% of patients. Symptomatic CE only occurred in two patients in the pre-inflation group. One patient had transient dysarthria and mild muscle weakness in one hand; the other patient complained of transient left upper limb weakness, left lower limb paresthesia and dysarthria. The incidence of ACE detected by cerebral MRI did not differ between the two groups to a statistically significant extent (conventional vs. pre-inflation; 22.9% vs. 29.2%; P = 0.49). In the multivariable analysis, eGFR was independently associated with the presence of ACE (odds ratio 0.95; 95% confidence interval 0.907-0.995; P = 0.03). Conclusion: In this prospective randomized study, the preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation had no impact on the incidence of ACE.

15.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34216250

RESUMEN

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejos Atriales Prematuros/diagnóstico , Criocirugía/efectos adversos , Frecuencia Cardíaca , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
16.
Sci Rep ; 11(1): 23591, 2021 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-34880293

RESUMEN

The optimal ablation strategy for persistent atrial fibrillation (PsAF) remains to be defined. We sought to compare very long-term outcomes between linear ablation and electrogram (EGM)-guided ablation for PsAF. In a retrospective analysis, long-term arrhythmia-free survival compared between two propensity-score matched cohorts, one with pulmonary vein isolation (PVI) and linear ablation including roof/mitral isthmus line (LINE-group, n = 52) and one with PVI and EGM-guided ablation (EGM-group; n = 52). Overall, 99% of patients underwent successful PVI. Complete block following linear ablation was achieved for 94% of roof lines and 81% of mitral lines (both lines blocked in 75%). AF termination by EGM-guided ablation was accomplished in 40% of patients. Non-PV foci were targeted in 7 (13%) in the LINE-group and 5 (10%) patients in the EGM-group (p = 0.76). During 100 ± 28 months of follow-up, linear ablation was associated with superior arrhythmia-free survival after the initial and last procedure (1.8 ± 0.9 procedures) compared with EGM-group (Logrank test: p = 0.0001 and p = 0.045, respectively). In multivariable analysis, longer AF duration and EGM-guided ablation remained as independent predictors of atrial arrhythmia recurrence. Linear ablation might be a more effective complementary technique to PVI than EGM-guided ablation for PsAF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
19.
Sci Rep ; 11(1): 6226, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33737633

RESUMEN

While phrenic nerve palsy (PNP) due to cryoballoon pulmonary vein isolation (PVI) of atrial fibrillation (AF) was transient in most cases, no studies have reported the results of the long-term follow-up of PNP. This study aimed to summarize details and the results of long-term follow-up of PNP after cryoballoon ablation. A total of 511 consecutive AF patients who underwent cryoballoon ablation was included. During right-side PVI, the diaphragmatic compound motor action potential (CMAP) was reduced in 46 (9.0%) patients and PNP occurred in 29 (5.7%) patients (during right-superior PVI in 20 patients and right-inferior PVI in 9 patients). PNP occurred despite the absence of CMAP reduction in 0.6%. The PV anatomy, freezing parameters and the operator's proficiency were not predictors of PNP. While PNP during RSPVI persisted more than 4 years in 3 (0.6%) patients, all PNP occurred during RIPVI recovered until one year after the ablation. However, there was no significant difference in the recovery duration from PNP between PNP during RSPVI and RIPVI. PNP occurred during cryoballoon ablation in 5.7%. While most patients recovered from PNP within one year after the ablation, PNP during RSPVI persisted more than 4 years in 0.6% of patients.


Asunto(s)
Angioplastia de Balón/efectos adversos , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Parálisis/diagnóstico , Traumatismos de los Nervios Periféricos/diagnóstico , Nervio Frénico/lesiones , Anciano , Fibrilación Atrial/patología , Criocirugía/instrumentación , Criocirugía/métodos , Humanos , Masculino , Persona de Mediana Edad , Parálisis/etiología , Parálisis/patología , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/patología , Venas Pulmonares/cirugía , Factores de Tiempo , Resultado del Tratamiento
20.
Heart Rhythm ; 18(5): 734-742, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33091601

RESUMEN

BACKGROUND: The risk of heart block during radiofrequency ablation of atrioventricular (AV) nodal reentrant tachycardia and septal accessory pathways is minimized by rapidly ceasing ablation in response to markers of risk, such as atrioventricular dissociation, fast junctional rhythm, PR interval prolongation, or 2 consecutive atrial or ventricular depolarizations. Currently this is done manually. OBJECTIVES: The objectives of this study were to build and test a control system able to monitor cardiac rhythm and automatically terminate ablation energy when required. METHODS: The device was built from off-shelf componentry. Preclinical testing involved real-time input of electrogram/electrocardiogram data from 209 ablation procedures (20 patients) over slow (n = 19) and fast (n = 1) AV nodal pathways. The device response speed was compared with the human response speed. The device's ability to prevent heart block was tested in 5 sheep. First-in-human testing was then performed in 12 patients undergoing AV nodal reentrant tachycardia ablation. RESULTS: Risk conditions necessitating shutoff of ablation (200 total; 111 preclinical and 89 first-in-human) were detected by the device with 100% sensitivity and 94% specificity, automatically terminating ablation while still allowing successful ablation in all patients. Device shutoff of ablation was always faster than human response (median difference 1.24 seconds). In each of 5 sheep, 40 consecutive attempts to cause heart block by ablating over the His bundle were unsuccessful because of automatic shutoff in response to rhythm change. CONCLUSION: Automated shutoff of ablation close to the AV node in response to markers of the risk of heart block is feasible with high accuracy as well as faster response than human response. The system may improve the safety of ablation near the AV node by preventing heart block.


Asunto(s)
Nodo Atrioventricular/fisiopatología , Estimulación Cardíaca Artificial/métodos , Ablación por Catéter/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/terapia , Animales , Modelos Animales de Enfermedad , Electrocardiografía , Humanos , Ovinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...