Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Opt Express ; 29(23): 38527-38539, 2021 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-34808904

RESUMEN

Laser intensity noise is one of the main limiting factors in pulsed vapor cell clocks. To reduce the contribution of the laser intensity noise to detection signal in the pulsed optically pumped atomic clock, a scheme based on the differential Faraday rotation angle is proposed. Theoretically, the Ramsey fringes, the sensitivity of clock frequency to laser intensity fluctuation and the signal to noise ratio for absorption, differential, and Faraday rotation angle methods are calculated and compared. Using a Wollaston prism rotated 45°relative to the incident polarization, and two photodetectors, Ramsey fringes of three detection methods are obtained simultaneously. In the proposed scheme, the long-term Faraday rotation angle fluctuation is 0.66% at 30000s, which is much smaller than fluctuation of traditional absorption signal 3.9% at 30000s. And the contribution of laser intensity noise to clock instability is also reduced. Using optimized photodetector with high common mode rejection ratio, a better performance should be expected. This proposed scheme is attractive for the development of high performance vapor clock based on pulsed optically pumped.

2.
Sensors (Basel) ; 15(11): 29183-91, 2015 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-26610491

RESUMEN

A refractive index sensor composed of two straight metal-insulator-metal waveguides and a ring resonator is presented. One end of each straight waveguide is sealed and the other end acts as port. The transmission spectrum and magnetic field distribution of this sensor structure are simulated using finite-difference time-domain method (FDTD). The results show that an asymmetric line shape is observed in the transmission spectrum, and that the transmission spectrum shows a filter-like behavior. The quality factor and sensitivity are taken to characterize its sensing performance and filter properties. How structural parameters affect the sensing performance and filter properties is also studied.

3.
Opt Express ; 19(7): 5753-9, 2011 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-21451600

RESUMEN

We propose and realize a novel packaged microsphere-taper coupling structure (PMTCS) with a high quality factor (Q) up to 5×10(6) by using the low refractive index (RI) ultraviolet (UV) glue as the coating material. The optical loss of the PMTCS is analyzed experimentally and theoretically, which indicate that the Q is limited by the glue absorption and the radiation loss. Moreover, to verify the practicability of the PMTCS, thermal sensing experiments are carried out, showing the excellent convenience and anti-jamming ability of the PMTCS with a high temperature resolution of 1.1×10(-3) ◦C. The experiments also demonstrate that the PMTCS holds predominant advantages, such as the robustness, mobility, isolation, and the PMTCS can maintain the high Q for a long time. The above advantages make the PMTCS strikingly attractive and potential in the fiber-integrated sensors and laser.


Asunto(s)
Refractometría/instrumentación , Dióxido de Silicio/efectos de la radiación , Termografía/instrumentación , Transductores , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Microesferas , Dispersión de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...