Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Neuroeng Rehabil ; 21(1): 45, 2024 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570841

RESUMEN

BACKGROUND: Knee osteoarthritis (KOA) is an irreversible degenerative disease that characterized by pain and abnormal gait. Radiography is typically used to detect KOA but has limitations. This study aimed to identify changes in plantar pressure that are associated with radiological knee osteoarthritis (ROA) and to validate them using machine learning algorithms. METHODS: This study included 92 participants with variable degrees of KOA. A modified Kellgren-Lawrence scale was used to classify participants into non-ROA and ROA groups. The total feature set included 210 dynamic plantar pressure features captured by a wearable in-shoe system as well as age, gender, height, weight, and body mass index. Filter and wrapper methods identified the optimal features, which were used to train five types of machine learning classification models for further validation: k-nearest neighbors (KNN), support vector machine (SVM), random forest (RF), AdaBoost, and eXtreme gradient boosting (XGBoost). RESULTS: Age, the standard deviation (SD) of the peak plantar pressure under the left lateral heel (f_L8PPP_std), the SD of the right second peak pressure (f_Rpeak2_std), and the SD of the variation in the anteroposterior displacement of center of pressure (COP) in the right foot (f_RYcopstd_std) were most associated with ROA. The RF model with an accuracy of 82.61% and F1 score of 0.8000 had the best generalization ability. CONCLUSION: Changes in dynamic plantar pressure are promising mechanical biomarkers that distinguish between non-ROA and ROA. Combining a wearable in-shoe system with machine learning enables dynamic monitoring of KOA, which could help guide treatment plans.


Asunto(s)
Osteoartritis de la Rodilla , Dispositivos Electrónicos Vestibles , Humanos , Osteoartritis de la Rodilla/diagnóstico por imagen , Radiografía , Marcha , Aprendizaje Automático
2.
Mater Horiz ; 10(2): 499-511, 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36412496

RESUMEN

Flexible pressure sensors are the foundation of wearable/implantable biosensing and human-machine interfaces, and mainly comprise piezoresistive-, capacitive-, piezoelectric-, and triboelectric-type sensors. As each type of sensor exhibits different electro-mechanical behaviors, it is challenging to detect various physiological mechanical signals that cover a large pressure range using a given sensor configuration, or even a single type of sensor. Here, we report a capacitive-piezoresistive hybrid flexible pressure sensor based on face-to-face-mounted conductive micropillar arrays as a solution to this challenge. The sensor exhibited high sensitivity over a wide dynamic range of five orders of magnitude, which covers almost the full range of physiological mechanical signals. A process for fabricating large-scale and morphologically homogeneous conductive micropillar arrays was first developed and refined. This track-etched-membrane-based process provides a facile, cost-effective, and highly flexible way to precisely adjust the morphology, modulus, and conductivity of the micropillars according to the application requirements. Subsequently, conductive-micropillar-array-based pressure sensors (MAPS) were developed and optimized to attain all-round sensing performance. The pillar contact behaviors generated significant variations in both the capacitance and resistance of the MAPS in the low-pressure regime (10-4-0.2 kPa), providing high sensitivity in both the capacitive and piezoresistive working modes. The vertical contact, bending and thickening of the pillars under medium pressure (0.2-16 kPa) led to a continuous linear response in both modes. Configuration and optimization enabled the MAPS to detect acoustic pressure (<1 Pa), milligram weights, soft touch (<1 kPa), arterial pulses (1-16 kPa preload), joint motions and plantar pressure (∼100 kPa), and the hybrid sensing mode allowed the MAPS to work in a desirable way. In this work, the piezoresistive mode was mainly employed for a higher accuracy and sampling rate, and can apparently simplify IC design for wearable applications. The circuit converts the resistive variations into electrical signals via the voltage division method and directly reads out the signals after further amplification, filtering and transmission. The improved facile and highly adjustable fabrication process, as well as the flexible hybrid sensing strategy, will benefit the unified design, batch production, quantifiable optimization, and functional diversity of wearable/implantable bioelectronics.

3.
J Adv Res ; 48: 61-74, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36041690

RESUMEN

INTRODUCTION: Reducing the protein adsorption of nanoparticles (NPs) as drug carriers to slow their rapid clearance by macrophages uptake is a critical challenge for NPs clinical translational applications. Despite extensive research efforts to inhibit cellular uptake, including covering biological agents or surface chemical coatings to impart "stealth" properties to NPs, their stability remains insufficient. OBJECTIVES: Developed a novel surface modification technology based on a physical infusion engineering approach to achieve persistent inhibition of protein adhesion and cellular uptake by nanocarriers. METHODS: The nanoparticles were prepared based on conventional drug carrier mesoporous silica NPs through a two-step process. A functional nanoscale slippery surface was formed by grafting "liquid-like" brushes on the particles surface, and then a lubricant-entrenched slippery surfaces (LESS) was formed by infusing silicone oil lubricant into the entire surface. Co-incubation with macrophages (in vitro and in vivo) was used to examine the anti-uptake properties of modified NPs. The anti-adhesion properties of LESS coating surfaces to various liquids, proteins and cells were used to analyze the anti-uptake mechanism. Loaded with drugs, combined with tumor models, to evaluate the drug utilization of modified NPs. RESULTS: Relying on the stable and slippery LESS coating, the modified surface could prevent the adhesion of various liquids and effectively shield against the adhesion of proteins and cells, as well as remarkably reduce macrophage cellular uptake in vitro and in vivo. In addition, the LESS coating does not affect cell activity and allows NPs to be loaded with drugs, significantly improving the utilization of drugs in vitro and in vivo. This allows the NPs to reach to the target tumor site for drug delivery without active clearance by macrophages. CONCLUSION: Our research introduces a new nanocarrier technology to improve anti-biofouling performance and stealth efficiency that will facilitate the development of nanomedicines for clinical transformation applications.


Asunto(s)
Macrófagos , Nanopartículas , Sistemas de Liberación de Medicamentos , Portadores de Fármacos/química , Nanopartículas/química , Utilización de Medicamentos
4.
Nat Commun ; 13(1): 2556, 2022 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-35581184

RESUMEN

Engineering wearable devices that can wirelessly track intraocular pressure and offer feedback-medicine administrations are highly desirable for glaucoma treatments, yet remain challenging due to issues of limited sizes, wireless operations, and wireless cross-coupling. Here, we present an integrated wireless theranostic contact lens for in situ electrical sensing of intraocular pressure and on-demand anti-glaucoma drug delivery. The wireless theranostic contact lens utilizes a highly compact structural design, which enables high-degreed integration and frequency separation on the curved and limited surface of contact lens. The wireless intraocular pressure sensing modulus could ultra-sensitively detect intraocular pressure fluctuations, due to the unique cantilever configuration design of capacitive sensing circuit. The drug delivery modulus employs an efficient wireless power transfer circuit, to trigger delivery of anti-glaucoma drug into aqueous chamber via iontophoresis. The minimally invasive, smart, wireless and theranostic features endow the wireless theranostic contact lens as a highly promising system for glaucoma treatments.


Asunto(s)
Lentes de Contacto , Glaucoma , Dispositivos Electrónicos Vestibles , Glaucoma/diagnóstico , Glaucoma/terapia , Humanos , Presión Intraocular , Medicina de Precisión
5.
ACS Sens ; 6(8): 3112-3124, 2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34347450

RESUMEN

Infection, the most common complication of chronic wounds, has placed tremendous burden on patients and society. Existing care strategies could hardly reflect in situ wound status, resulting in overly aggressive or conservative therapeutic options. Multiplexed tracking of wound markers to obtain diagnostic information in a more accurate way is highly promising and in great demand for the emerging development of personalized medicine. Here, an integrated multiplex sensing bandage (MSB) system, including a multiplex sensor array (MSA), a corresponding flexible circuit, and a mobile application, was developed for real-time monitoring of sodium, potassium, calcium, pH, uric acid, and temperature indicators in the wound site to provide a quantitative diagnostic basis. The MSB was optimized for wound-oriented management applications, which exhibits a broad linear response, excellent selectivity, temporal stability, mechanical stability, reproducibility, and reliable signal transmission performance on the aforementioned physiological indicators. The results of in vivo experiments demonstrate that the MSA is capable of real-time monitoring of actual wounds as well as early prediction of infection. The results ultimately point to the potential clinical applicability of the MSB, which might benefit the quantifications of the complexity and diversity of the wound healing process. This work provides a unique strategy that holds promise for broad application in optimizing wound management and even coping with other diseases.


Asunto(s)
Vendajes , Ácido Úrico , Humanos , Reproducibilidad de los Resultados
6.
Adv Sci (Weinh) ; 8(6): 2002971, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33747725

RESUMEN

Biosensors worn on or implanted in eyes have been garnering substantial attention since being proven to be an effective means to acquire critical biomarkers for monitoring the states of ophthalmic disease, diabetes. Among these disorders, glaucoma, the second leading cause of blindness globally, usually results in irreversible blindness. Continuous intraocular pressure (IOP) monitoring is considered as an effective measure, which provides a comprehensive view of IOP changes that is beyond reach for the "snapshots" measurements by clinical tonometry. However, to satisfy the applications in ophthalmology, the development of IOP sensors are required to be prepared with biocompatible, miniature, transparent, wireless and battery-free features, which are still challenging with many current fabrication processes. In this work, the recent advances in this field are reviewed by categorizing these devices into wearable and implantable IOP sensors. The materials and structures exploited for engineering these IOP devices are presented. Additionally, their working principle, performance, and the potential risk that materials and device architectures may pose to ocular tissue are discussed. This review should be valuable for preferable structure design, device fabrication, performance optimization, and reducing potential risk of these devices. It is significant for the development of future practical IOP sensors.

7.
J Colloid Interface Sci ; 589: 327-335, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33476889

RESUMEN

Liquid food containers commonly suffer from inevitable contamination and even biofilm formation due to the adhesion of food residuals or saliva, which requires detergents to clean. Although previously reported superhydrophobic and omniphobic coatings can resist the adhesion of liquids, the requirements of specific nanostructures or infused lubricants limit their applications in food containers. Here, by grafting smooth glass containers with "liquid like" polydimethylsiloxane brushes, we developed a unique approach for preparing a slippery coating that could exhibit highly robust repellency to various liquid foods. The coating was highly transparent and did not induce a significant alteration of the smooth surface. The "liquid like" coating could effectively prevent the adhesion of various liquid foods and inhibit the formation of bacterial biofilms, without the use of detergents for cleaning. Moreover, this coating could resist mechanical damage from friction, and displayed high biocompatibility with biological cells. The slipperiness, smoothness, robustness and biocompatibility of the "liquid like" coating was highly beneficial to practical applications as self-cleaning glass container, which has been challenging to achieve by conventional superhydrophobic or omniphobic coatings. Our study introduced a versatile strategy to functionalize biocompatible surfaces for food containers which reduced the contamination of residues and the use of detergents, and may be beneficial to human and environmental health.


Asunto(s)
Nanoestructuras , Polímeros , Biopelículas , Vidrio , Humanos , Propiedades de Superficie
8.
ACS Appl Mater Interfaces ; 13(3): 4450-4462, 2021 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-33443399

RESUMEN

Biosensors that can automatically and continuously track fluctuations in biomarker levels over time are essential for real-time sensing in biomedical and environmental applications. Although many electrochemical sensors have been developed to quickly and sensitively monitor biomarkers, their sensing stability in complex biofluids is disturbed by unavoidable nonspecific adhesion of proteins or bacteria. Recently, various substrate surface modification techniques have been developed to resist biofouling, yet functionalization of electrodes in sensors to be anti-biofouling is rarely achieved. Here, we report an integrated three-electrode system (ITES) modified with a "liquid-like" polydimethylsiloxane (PDMS) brush that can continuously and stably monitor reactive oxygen species (ROS) in complex fluids. Based on the slippery "liquid-like" coating, the modified ITES surface could prevent the adhesion of various liquids as well as the adhesion of proteins and bacteria. The "liquid-like" coating does not significantly affect the sensitivity of the electrode in detecting ROS, while the sensing performance could remain stable and free of bacterial attack even after 3 days of incubation with bacteria. In addition, the PDMS brush-modified ITES (PMITES) could continuously record ROS levels in bacterial-rich fluids with excellent stability over 24 h due to the reduced bacterial contamination on the electrode surface. This technique offers new opportunities for continuous and real-time monitoring of biomarkers that will facilitate the development of advanced sensors for biomedical and environmental applications.


Asunto(s)
Incrustaciones Biológicas/prevención & control , Técnicas Biosensibles/instrumentación , Dimetilpolisiloxanos/química , Técnicas Electroquímicas/instrumentación , Electrodos , Diseño de Equipo , Células HeLa , Humanos , Oxidación-Reducción , Especies Reactivas de Oxígeno/análisis
9.
ACS Biomater Sci Eng ; 6(1): 358-366, 2020 01 13.
Artículo en Inglés | MEDLINE | ID: mdl-33463210

RESUMEN

Materials for biodevices and bioimplants commonly suffer from unwanted but unavoidable biofouling problems due to the nonspecific adhesion of proteins, cells, or bacteria. Chemical coating or physical strategies for reducing biofouling have been pursued, yet highly robust antibiofouling surfaces that can persistently resist contamination in biological environments are still lacking. In this study, we developed a facile method to fabricate a highly robust slippery and antibiofouling surface by conjugating a liquid-like polymer layer to a substrate. This slippery liquid-attached (SLA) surface was created via a one-step equilibration reaction by tethering methoxy-terminated polydimethylsiloxane (PDMS-OCH3) polymer brushes onto a substrate to form a transparent "liquid-like" layer. The SLA surface exhibited excellent sliding behaviors toward a wide range of liquids and small particles and antibiofouling properties against the long-term adhesion of small biomolecules, proteins, cells, and bacteria. Moreover, in contrast to superomniphobic surfaces and liquid-infused porous surfaces (SLIPS) requiring micro/nanostructures, the SLA layer could be obtained on smooth surfaces and maintain its biofouling resistance under abrasion with persistent stability. Our study offers a simple method to functionalize surfaces with robust slippery and antibiofouling properties, which is promising for potential applications including medical implants and biodevices.


Asunto(s)
Incrustaciones Biológicas , Nanoestructuras , Incrustaciones Biológicas/prevención & control , Polímeros , Porosidad , Propiedades de Superficie
10.
Microsyst Nanoeng ; 6: 41, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-34567654

RESUMEN

Since toxic gas leakage may cause ecological environmental problems and even life-threatening damage, effective monitoring of toxic gas is of great importance and subject to increasing demand. However, complicated environmental factors, as well as various coexisting interferences can easily affect the sensitivity and selectivity of gas sensors, hindering their performance. Recent reports have successfully demonstrated the development of hierarchical nanostructures with desirable self-cleaning properties, yet gas sensors that can resist contamination have rarely been realized. Here, we developed a reentrant thorny ZnO/graphene hybrid nanowall structure that simultaneously repels liquid contamination and possesses NH3 gas sensing properties. The unique reentrant and hierarchical structure, featuring an interconnected vertical graphene nanowall framework with numerous ZnO nanospikes branched on the top nanowall, is highly repellent to liquids, even biofluids with low surface tension. The hierarchical structure consisting of gas sensing graphene and ZnO can be successfully applied as an NH3 gas sensor at room temperature, exhibiting not only excellent sensitivity, selectivity, and repeatability, but also outstanding stability even after bacterial contamination. This study provides a versatile method for fabricating reentrant and hierarchical structures with excellent liquid repellency, and offers a promising method for designing reliable gas sensors with anti-biofouling properties.

11.
Nanotechnology ; 31(9): 095712, 2020 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-31739294

RESUMEN

Hydrophobic particles have been suffering from aggregation in aqueous media, which limits their applications in oil/water separation. Surfactants have been used to increase the dispersity of the hydrophobic particles in water, but this approach compromises particles' hydrophobicity and oil absorption capabilities. Recently, hierarchical microparticles decorated with nanospikes were found to exhibit long-term anomalous dispersion in liquid medium without adding any surfactants. However, whether this anomalous dispersion phenomenon was applicable to 2D nano-petals decorated microparticles still remains unknown. Here, we developed a ZnO-based flower-like microparticles (FLMPs) whose surfaces were attached with 2D nano-petals, and we examined their anomalous dispersity. Our results showed that both hydrophilic and hydrophobic FLMPs could achieve anomalous dispersity either in water or organic solvents, likely due to reduced interparticle collision by the 2D nano-petals. In addition, the functional hydrophobic FLMPs also possessed a large surface area and superhydrophobic surfaces to efficiently absorb oil spills on water and oil emulsion suspended in water. In contrast, the hydrophobic microbeads (MBs) without nano-petals structure seriously aggregated in water and exhibited reduced oil absorption abilities. Our work demonstrated the new finding of 2D nano-pedal structure-mediated anomalous dispersity, and provided a new method for effective oil/water separation using superhydrophobic particles without surfactants.

12.
Nano Lett ; 19(10): 7201-7209, 2019 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-31557044

RESUMEN

Downstream analysis of circulating tumor cells (CTCs) has provided new insights into cancer research. In particular, the detection of CTCs, followed by the regulation and monitoring of their intracellular activities, can provide valuable information for comprehensively understanding cancer pathogenesis and progression. However, current CTC detection techniques are rarely capable of in situ regulation and monitoring of the intracellular microenvironments of cancer cells over time. Here, we developed a multifunctional branched nanostraw (BNS)-electroporation platform that could effectively capture CTCs and allow for downstream regulation and monitoring of their intracellular activities in a real-time and in situ manner. The BNSs possessed numerous nanobranches on the outer sidewall of hollow nanotubes, which could be conjugated with specific antibodies to facilitate the effective capture of CTCs. Nanoelectroporation could be applied through the BNSs to nondestructively porate the membranes of the captured cells at a low voltage, allowing the delivery of exogenous biomolecules into the cytosol and the extraction of cytosolic contents through the BNSs without affecting cell viability. The efficient delivery of biomolecules (e.g., small molecule dyes and DNA plasmids) into cancer cells with spatial and temporal control and, conversely, the repeated extraction of intracellular enzymes (e.g., caspase-3) for real-time monitoring were both demonstrated. This technology can provide new opportunities for the comprehensive understanding of cancer cell functions that will facilitate cancer diagnosis and treatment.


Asunto(s)
Electroporación/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Nanoestructuras , Células Neoplásicas Circulantes/patología , Línea Celular Tumoral , Molécula de Adhesión Celular Epitelial/análisis , Diseño de Equipo , Humanos , Nanoestructuras/química , Nanotecnología/instrumentación , Neoplasias/metabolismo , Neoplasias/patología , Células Neoplásicas Circulantes/metabolismo
13.
ACS Appl Mater Interfaces ; 11(34): 30575-30584, 2019 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-31382742

RESUMEN

A hypertensive emergency causes severe cardiovascular diseases accompanied by acute target organ damage, requiring rapid and smooth blood pressure (BP) reduction. Current medicines for treating hypertensive emergencies, such as sodium nitroprusside (SNP), require careful dose control to avoid side effects (e.g., cyanide poisoning). The clinical administration of SNP using intravenous injection or drip further restrict its usage for first aid or self-aid in emergencies. Here, we developed an antihypertensive microneedle (aH-MN) technique to transdermally deliver SNP in combination with sodium thiosulfate (ST) as a cyanide antidote in a painless way. Dissolvable microneedles loaded with SNP and ST were fabricated via the centrifugation casting method, where the SNPs were stably packaged in microneedles and would be immediately released into the systemic circulation via subcutaneous capillaries when aH-MNs penetrated the skin. The antihypertensive effects were demonstrated on spontaneously hypertensive rat models. Rapid and potent BP reduction was achieved via aH-MN treatment, fulfilling clinical BP-control requirements for hypertensive emergencies. The side effects including skin irritation and target organ damage of aH-MN therapies were evaluated; the combinative delivery of ST effectively suppressed these side effects induced by the consecutive intake of SNP. This study introduces an efficient and patient-friendly antihypertensive therapy with a favorable side-effect profile, particularly a controllable and self-administrable approach to treat hypertensive emergencies.


Asunto(s)
Antihipertensivos , Hipertensión/tratamiento farmacológico , Agujas , Piel/metabolismo , Administración Cutánea , Animales , Antihipertensivos/química , Antihipertensivos/farmacología , Humanos , Hipertensión/metabolismo , Hipertensión/patología , Ratas
14.
ACS Cent Sci ; 5(6): 960-969, 2019 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-31263755

RESUMEN

The intracellular delivery of biomolecules is of significant importance yet challenging. In addition to the conventional delivery of nanomaterials that rely on biochemical pathways, vertical nanowires have been recently proposed to physically penetrate the cell membrane, thus enabling the direct release of biomolecules into the cytoplasm circumventing endosomal routes. However, due to the inherent attachment of the nanowires to a planar 2D substrate, nanowire cell penetrations are restricted to in vitro applications, and they are incapable of providing solution-based delivery. To overcome this structural limitation, we created polyethylenimine-functionalized microparticles covered with nanospikes, namely, "spiky particles", to deliver biomolecules by utilizing the nanospikes to penetrate the cell membrane. The nanospikes might penetrate the cell membrane during particle engulfment, and this enables the bound biomolecules to be released directly into the cytosol. TiO2 spiky particles were fabricated through hydrothermal routes, and they were demonstrated to be biocompatible with HeLa cells, macrophage-like RAW cells, and fibroblast-like 3T3-L1 cells. The polyethylenimine-functionalized spiky particles provided direct delivery of fluorescent siRNA into cell cytosol and functional siRNA for gene knockdown as well as successful DNA plasmid transfection which were difficult to achieve by using microparticles without nanospikes. The spiky particles presented a unique direct cell membrane penetrant vehicle to introduce biomolecules into cell cytosol, where the biomolecules might bypass conventional endocytic degradation routes.

15.
ACS Cent Sci ; 5(2): 250-258, 2019 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-30834313

RESUMEN

Injectable micron-sized particles have historically achieved promising applications, but they continued to suffer from long-term biofouling caused by the adhesions of biomolecules, cells, and bacteria. Recently, a slippery lubricant infusion porous substrate (SLIPS) exhibited robust antiadhesiveness against many liquids; however, they were constructed using a 2D substrate, and they were not suitable for in vivo applications, such as injectable biomaterials. Inspired by SLIPS, here, we report the first case of injectable solid microparticles coated with a lubricating liquid surface to continuously resist biofouling. In our design, microparticles were attached with nanospikes and fluorinated to entrap the lubricant. The nanospikes enabled the lubricant-coated spiky microparticles (LCSMPs) to anomalously disperse in water despite the attraction between the surfaces of the microparticles. This result indicated that the LCSMPs exhibited persistent anomalous dispersity in water while maintaining a robust lubricating surface layer. LCSMPs prevented the adhesion of proteins, mammalian cells, and bacteria, including Escherichia coli and Staphylococcus aureus. LCSMPs also reduced in vivo fibrosis while conventional microparticles were heavily biofouled. This technology introduced a new class of injectable anti-biofouling microparticles with reduced risks of inflammation and infections.

16.
ACS Appl Mater Interfaces ; 11(5): 4809-4819, 2019 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-30628778

RESUMEN

Real-time transdermal biosensing provides a direct route to quantify biomarkers or physiological signals of local tissues. Although microneedles (MNs) present a mini-invasive transdermal technique, integration of MNs with advanced nanostructures to enhance sensing functionalities has rarely been achieved. This is largely due to the fact that nanostructures present on MNs surface could be easily destructed due to friction during skin insertion. In this work, we reported a dissolvable polymer-coating technique to protect nanostructures-integrated MNs from mechanical destruction during MNs insertion. After penetration into the skin, the polymer could readily dissolve by interstitial fluids so that the superficial nanostructures on MNs could be re-exposed for sensing purpose. To demonstrate this technique, metallic and resin MNs decorated with vertical ZnO nanowires (vNWs) were employed as an example. Dissolvable poly(vinyl pyrrolidone) was spray-coated on the vNW-MNs surface as a protective layer, which effectively protected the superficial ZnO NWs when MNs penetrated the skin. Transdermal biosensing of H2O2 biomarker in skin tissue using the polymer-protecting MNs sensor was demonstrated both ex vivo and in vivo. The results indicated that polymer coating successfully preserved the sensing functionalities of the MNs sensor after inserting into the skin, whereas the sensitivity of the MN sensor without a coating protection was significantly compromised by 3-folds. This work provided unique opportunities of protecting functional nanomodulus on MNs surface for minimally invasive transdermal biosensing.


Asunto(s)
Técnicas Biosensibles/instrumentación , Microinyecciones/instrumentación , Nanocables/química , Agujas , Animales , Diseño de Equipo , Ratones , Ratones Endogámicos C57BL , Modelos Biológicos , Povidona/química , Piel/química , Porcinos , Óxido de Zinc/química
17.
Small ; 15(6): e1804298, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30605244

RESUMEN

A variety of nanomaterial-based biosensors have been developed to sensitively detect biomolecules in vitro, yet limited success has been achieved in real-time sensing in vivo. The application of microneedles (MN) may offer a solution for painless and minimally-invasive transdermal biosensing. However, integration of nanostructural materials on microneedle surface as transdermal electrodes remains challenging in applications. Here, a transdermal H2 O2 electrochemical biosensor based on MNs integrated with nanohybrid consisting of reduced graphene oxide and Pt nanoparticles (Pt/rGO) is developed. The Pt/rGO significantly improves the detection sensitivity of the MN electrode, while the MNs are utilized as a painless transdermal tool to access the in vivo environment. The Pt/rGO nanostructures are protected by a water-soluble polymer layer to avoid mechanical destruction during the MN skin insertion process. The polymer layer can readily be dissolved by the interstitial fluid and exposes the Pt/rGO on MNs for biosensing in vivo. The applications of the Pt/rGO-integrated MNs for in situ and real-time sensing of H2 O2 in vivo are demonstrated both on pigskin and living mice. This work offers a unique real-time transdermal biosensing system, which is a promising tool for sensing in vivo with high sensitivity but in a minimally-invasive manner.


Asunto(s)
Técnicas Biosensibles , Grafito/química , Nanopartículas/química , Agujas , Administración Cutánea , Animales , Técnicas Electroquímicas , Electrodos , Peróxido de Hidrógeno/análisis , Ratones Endogámicos C57BL , Nanopartículas/ultraestructura , Platino (Metal)/química , Povidona/química , Porcinos
18.
ACS Appl Mater Interfaces ; 11(1): 1294-1302, 2019 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-30525418

RESUMEN

The development of wearable strain sensors for the human-machine interface has attracted considerable research interest. Most existing wearable strain sensors were incapable of simultaneously detecting strain amplitudes and directions, and they failed to fully record stretching vectors that occurred on the body. Graphene and graphene-derived materials have been utilized to construct wearable strain sensors with excellent electrical sensitivities. Although the growth techniques of planar graphene and vertical graphene (VG) have been established, the fabrication of VG aligned in parallel within a larger area has not been previously achieved. Here, parallelly aligned VG (PAVG) in a large area was successfully fabricated and constructed as a wearable strain vector sensor. The PAVG was fabricated via inductively coupled plasma chemical vapor deposition assisted by metal inducers. The as-fabricated sensor was electrically anisotropic because of the profiles of the VG nanosheets aligned in parallel. Therefore, the sensor could simultaneously and sensitively detect the direction and the amplitude of the strain vectors with excellent accuracy. Application of this strain vector sensor for the human-sensor interface to identify the stretching directions and amplitudes of finger joints was also demonstrated. This work established the fabrication methodology of graphene with unique vertical and parallel alignment morphology. This study introduced a new opportunity of developing wearable sensors that could fully detect multidirectional human actions.

19.
Nat Nanotechnol ; 13(11): 1078-1086, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30374159

RESUMEN

Microbial biochemicals have been indicated as the primary stimulators of innate immunity, the first line of the body's defence against infections. However, the influence of topological features on a microbe's surface on immune responses remains largely unknown. Here we demonstrate the ability of TiO2 microparticles decorated with nanospikes (spiky particles) to activate and amplify the immune response in vitro and in vivo. The nanospikes exert mechanical stress on the cells, which results in potassium efflux and inflammasome activation in macrophages and dendritic cells during phagocytosis. The spiky particles augment antigen-specific humoral and cellular immune responses in the presence of monophosphoryl lipid A and elicit protective immunity against tumour growth and influenza viral infection. The study offers insights into how surface physical cues can tune the activation of innate immunity and provides a basis for engineering particles with increased immunogenicity and adjuvanticity.


Asunto(s)
Células Dendríticas/inmunología , Macrófagos/inmunología , Nanopartículas , Fagocitosis/efectos de los fármacos , Titanio , Animales , Células Dendríticas/patología , Virus de la Influenza A/inmunología , Lípido A/análogos & derivados , Lípido A/farmacología , Macrófagos/patología , Ratones , Ratones Noqueados , Nanopartículas/química , Nanopartículas/uso terapéutico , Neoplasias Experimentales/inmunología , Neoplasias Experimentales/patología , Neoplasias Experimentales/terapia , Infecciones por Orthomyxoviridae/inmunología , Infecciones por Orthomyxoviridae/patología , Infecciones por Orthomyxoviridae/terapia , Titanio/química , Titanio/farmacología
20.
Sci Rep ; 8(1): 12600, 2018 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-30135437

RESUMEN

Many fields of applications require dispersion of hydrophobic particles in water, which is traditionally achieved by using surfactants or amphiphilic molecules to modify particle surfaces. However, surfactants or amphiphilic molecules may disturb the native solution or particles' surface hydrophobicity, limiting extended applications such as oil emulsion cleaning. Recently one example of 2 µm-size polystyrene microparticles covered with ZnO nanospikes has been shown to exhibit excellent dispersity in water in spite of surface hydrophobicity. Whether this anomalous dispersion phenomenon was applicable to other hydrophobic microparticle systems was still unclear and its application scope was limited. Here the anomalous dispersities of different hydrophobic spiky micro-objects were systematically explored. The results show that the anomalous dispersion phenomenon was universally observed on different hydrophobic spiky micro-objects including different hydrophobic coating, particle sizes, material compositions and core particle morphologies. In addition, the spiky micro-objects displayed anomalous dispersity in water without compromising surface hydrophobicity, and their applications for oil spills absorption and oil emulsion cleaning were demonstrated. This work offers unique insight on the nanospikes-mediated anomalous dispersion phenomenon of hydrophobic micro-object and potentially extends its applicability and application scopes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...