Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
BMJ Open Respir Res ; 10(1)2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37532473

RESUMEN

PURPOSE: Despite the importance of radial endobronchial ultrasound (rEBUS) in transbronchial biopsy, researchers have yet to apply artificial intelligence to the analysis of rEBUS images. MATERIALS AND METHODS: This study developed a convolutional neural network (CNN) to differentiate between malignant and benign tumours in rEBUS images. This study retrospectively collected rEBUS images from medical centres in Taiwan, including 769 from National Taiwan University Hospital Hsin-Chu Branch, Hsinchu Hospital for model training (615 images) and internal validation (154 images) as well as 300 from National Taiwan University Hospital (NTUH-TPE) and 92 images were obtained from National Taiwan University Hospital Hsin-Chu Branch, Biomedical Park Hospital (NTUH-BIO) for external validation. Further assessments of the model were performed using image augmentation in the training phase and test-time augmentation (TTA). RESULTS: Using the internal validation dataset, the results were as follows: area under the curve (AUC) (0.88 (95% CI 0.83 to 0.92)), sensitivity (0.80 (95% CI 0.73 to 0.88)), specificity (0.75 (95% CI 0.66 to 0.83)). Using the NTUH-TPE external validation dataset, the results were as follows: AUC (0.76 (95% CI 0.71 to 0.80)), sensitivity (0.58 (95% CI 0.50 to 0.65)), specificity (0.92 (95% CI 0.88 to 0.97)). Using the NTUH-BIO external validation dataset, the results were as follows: AUC (0.72 (95% CI 0.64 to 0.82)), sensitivity (0.71 (95% CI 0.55 to 0.86)), specificity (0.76 (95% CI 0.64 to 0.87)). After fine-tuning, the AUC values for the external validation cohorts were as follows: NTUH-TPE (0.78) and NTUH-BIO (0.82). Our findings also demonstrated the feasibility of the model in differentiating between lung cancer subtypes, as indicated by the following AUC values: adenocarcinoma (0.70; 95% CI 0.64 to 0.76), squamous cell carcinoma (0.64; 95% CI 0.54 to 0.74) and small cell lung cancer (0.52; 95% CI 0.32 to 0.72). CONCLUSIONS: Our results demonstrate the feasibility of the proposed CNN-based algorithm in differentiating between malignant and benign lesions in rEBUS images.


Asunto(s)
Aprendizaje Profundo , Neoplasias Pulmonares , Humanos , Inteligencia Artificial , Estudios Retrospectivos , Redes Neurales de la Computación , Neoplasias Pulmonares/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...