Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Mater ; 36(24): e2311106, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38388858

RESUMEN

Electrochemical biosensors have emerged as one of the promising tools for tracking human body physiological dynamics via non-invasive perspiration analysis. However, it remains a key challenge to integrate multiplexed sensors in a highly controllable and reproducible manner to achieve long-term reliable biosensing, especially on flexible platforms. Herein, a fully inkjet printed and integrated multiplexed biosensing patch with remarkably high stability and sensitivity is reported for the first time. These desirable characteristics are enabled by the unique interpenetrating interface design and precise control over active materials mass loading, owing to the optimized ink formulations and droplet-assisted printing processes. The sensors deliver sensitivities of 313.28 µA mm-1 cm-2 for glucose and 0.87 µA mm-1 cm-2 for alcohol sensing with minimal drift over 30 h, which are among the best in the literature. The integrated patch can be used for reliable and wireless diet monitoring or medical intervention via epidermal analysis and would inspire the advances of wearable devices for intelligent healthcare applications.


Asunto(s)
Técnicas Biosensibles , Glucosa , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Glucosa/análisis , Humanos , Sudor/química , Sudor/metabolismo , Impresión , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Etanol/análisis
2.
Zhongguo Yi Liao Qi Xie Za Zhi ; 32(3): 186-9, 2008 May.
Artículo en Chino | MEDLINE | ID: mdl-18754420

RESUMEN

This paper proposes an algorithm of evaluating the compression depth, and then to extract four normalized mammary elasticity characteristic parameters with respect to the compression depth. The classification experiments show that these elasticity parameters have a good capability in determining whether the tumor is benign or malignant, and if combined with morphological parameters, the accuracy, sensitivity and specificity can be improved and increased to 95.19%, 98.82% and 92.16%, respectively.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Ultrasonografía Mamaria/métodos , Algoritmos , Femenino , Humanos , Sensibilidad y Especificidad
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 32(6): 398-401, 2008 Nov.
Artículo en Chino | MEDLINE | ID: mdl-19253568

RESUMEN

This paper presents a computer-aided diagnosis method for prostate cancer detection using Trans-rectal ultrasound(TRUS) images. Firstly, statistical texture analysis is implemented in every ROI in segmented prostate images. From each ROI, grey level difference vector features, edge-frequency features and texture features in frequency domain are constructed. Then, the number of features is reduced using ANOVA statistics to select the optimal feature subset. Finally, SVM is applied to the selected subset for detecting the cancer regions. Experimental results show that the proposed algorithm can recognize and detect the cancer images effectively so as to supply essential information for a diagnosis.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Algoritmos , Inteligencia Artificial , Humanos , Masculino , Redes Neurales de la Computación , Ultrasonografía
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 32(5): 316-8, 358, 2008 Sep.
Artículo en Chino | MEDLINE | ID: mdl-19119647

RESUMEN

In this paper, we propose that, the need of the costly re-initialization procedure can be completely eliminated by using the variation formulation, thus increasing the speed of computing operations. The edge detecting function in the geodesic active contour model is improved by incorporating a prior knowledge. The accuracy of the segmentation algorithm can be enhanced by using the minimal variance. Experimental results show that the proposed algorithm can segment the prostate ultrasound images effectively and avoid the problem of contour leakage.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Próstata/diagnóstico por imagen , Ultrasonografía/métodos , Algoritmos , Humanos , Masculino , Reconocimiento de Normas Patrones Automatizadas/métodos , Ultrasonografía/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA