Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Eng Technol ; 10(4): 618-627, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31598894

RESUMEN

PURPOSE: Prompt detection of congestion is an essential target in order to prevent heart failure (HF) related hospitalization, being ambulatory monitoring a promising strategy to do so. A successful non-invasive ambulatory monitoring system requires automatic devices for physiological data recording; these data must give information about HF deterioration early enough to predict HF-related adverse events. This work aims to evaluate seven vascular parameters for the ambulatory monitoring of congestive heart failure patients. METHODS: Seven vascular parameters are proposed as indicators of HF deterioration. These parameters are obtained using venous occlusion plethysmography; a technique that uses hardware able of being miniaturized and easily integrated into wearables for ambulatory monitoring. The ability of the proposed vascular parameters to detect congestion is evaluated in eight healthy volunteers and ten congestive heart failure patients with different congestion levels-mild, moderate and severe. RESULTS: Most parameters distinguish between healthy volunteers and heart failure patients, and some of them present significant differences between volunteers and low levels of congestion-mild or moderate. CONCLUSION: Home monitoring of some of the proposed parameters could detect HF deterioration on its onset and alert to health personnel.


Asunto(s)
Insuficiencia Cardíaca/diagnóstico , Hemodinámica , Monitoreo Ambulatorio/métodos , Pletismografía , Telemetría , Adulto , Anciano , Estudios de Casos y Controles , Diseño de Equipo , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Miniaturización , Modelos Cardiovasculares , Monitoreo Ambulatorio/instrumentación , Pletismografía/instrumentación , Valor Predictivo de las Pruebas , Pronóstico , Prueba de Estudio Conceptual , Índice de Severidad de la Enfermedad , Telemetría/instrumentación , Función Ventricular Izquierda , Dispositivos Electrónicos Vestibles , Adulto Joven
2.
J Med Eng Technol ; 39(3): 208-15, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25815889

RESUMEN

Pressure sensors are valuable transducers that are necessary in a huge number of medical application. However, the state of the art of compact and lightweight pressure sensors with the capability of measuring the contact pressure between two surfaces (contact pressure sensors) is very poor. In this work, several types of wearable contact pressure sensors are fabricated using different conductive textile materials and piezo-resistive films. The fabricated sensors differ in size, the textile conductor used and/or the number of layers of the sandwiched piezo-resistive film. The intention is to study, through the obtaining of their calibration curves, their metrological properties (repeatability, sensitivity and range) and determine which physical characteristics improve their ability for measuring contact pressures. It has been found that it is possible to obtain wearable contact pressure sensors through the proposed fabrication process with satisfactory repeatability, range and sensitivity; and that some of these properties can be improved by the physical characteristics of the sensors.


Asunto(s)
Monitoreo Ambulatorio/instrumentación , Transductores , Calibración , Diseño de Equipo , Presión , Reproducibilidad de los Resultados , Textiles
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA