1.
Shoulder Elbow ; 13(4): 445-450, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34394742

RESUMEN

BACKGROUND: Over-lengthening of the radial neck has been shown to affect ulnohumeral kinematics and has been proposed to affect radiocapitellar pressures. We hypothesized that an incremental increase in radial neck height increases the capitellar contact pressure and reduces the coronoid contact pressure. Knowledge of the effects of over-lengthening is clinically important in preventing pain and degenerative changes due to overstuffing. METHODS: Six human cadaveric elbows were prepared on a custom-designed apparatus simulating muscle loads and passive flexion from 0° to 90° under gravity valgus torque while measuring joint contact pressures in this biomechanical study. Each elbow was tested sequentially starting with the intact specimen followed by insertion of a radial head prosthesis with 0, +2, and +4 mm of radial neck height, respectively. RESULTS: Capitellar mean contact pressures significantly increased after insertion of +2 and +4 mm radial head prostheses (p < 0.03). The capitellar mean contact pressure with a 0 mm radial head prosthesis was 97 KPa. Insertion of +2 mm and +4 mm radial heads increased mean contact pressures to 391 KPa (p = 0.001) and 619 KPa (p = 0.001), respectively, with 90° of elbow flexion. DISCUSSION: Increasing radial prosthesis height by 2 mm significantly increases capitellar contact pressures and reduces coronoid contact pressures.