Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Magn Reson Imaging ; 59(1): 192-200, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37224304

RESUMEN

BACKGROUND: A noninvasive and reliable approach to quantitatively measure muscle perfusion of lower extremity is needed to aid the diagnosis and treatment of peripheral artery disease (PAD). PURPOSE: To verify the reproductivity of using blood oxygen level-dependent (BOLD) imaging to evaluate perfusion in lower extremities, and explore its correlation with walking performance in patients with PAD. STUDY TYPE: Prospective observational study. SUBJECTS: Seventeen patients with lower extremity PAD (mean age: 67 ± 6 years, 15 males) and eight older adults (controls). FIELD STRENGTH/SEQUENCE: Dynamic multi-echo gradient echo T2* weighted imaging at 3T. ASSESSMENT: Perfusion was analyzed in regions of interest according to muscle groups. Perfusion parameters were measured, such as minimum ischemia value (MIV), time to peak (TTP), and gradient during reactive hyperemia (Grad) by two independent users. Walking performance experiments including short physical performance battery (SPPB) and 6-minute walk were tested in patients. STATISTICAL TESTS: BOLD parameters were compared using Mann-Whitney U test and Kruskal-Wallis test. Relations between parameters and walking performance were assessed by Mann-Whitney U test and Spearman's correlation coefficient. RESULTS: Good to perfect agreement was demonstrated for all perfusion parameters of interuser reproducibility, and the interscan reproducibility of MIV, TTP, and Grad was good. The TTP of the patients was longer than that of the controls (87.85 ± 38.85 s vs. 36.54 ± 7.27 s), while the Grad of patients was smaller (0.16 ± 0.12 msec/s vs. 0.24 ± 0.11 msec/s). Among PAD patients, the MIV was significantly lower in the low SPPB subgroup (score 6-8) than in the high SPPB group (score 9-12), and the TTP was negatively correlated with 6-minute walk distance (ρ = -0.549). DATA CONCLUSION: BOLD imaging method had overall good reproducibility for the perfusion assessment of calf muscles. The perfusion parameters were different between PAD patients and controls, and were correlated with lower extremity function. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Saturación de Oxígeno , Enfermedad Arterial Periférica , Anciano , Humanos , Masculino , Persona de Mediana Edad , Isquemia , Extremidad Inferior/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Músculo Esquelético , Oxígeno/metabolismo , Enfermedad Arterial Periférica/metabolismo , Reproducibilidad de los Resultados , Caminata , Femenino
2.
Quant Imaging Med Surg ; 11(8): 3726-3734, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34341745

RESUMEN

BACKGROUND: Currently, the thoracic endovascular aortic repair is the recommended clinical treatment for type B aortic dissections. Unfortunately, malperfusion or ischemia of the kidneys is a major complication of type B aortic dissections. Despite this, few studies have focused on the effects of thoracic endovascular aortic repair on blood flow in renal arteries and parenchyma. This current investigation used novel real-time imaging software to quantitatively analyze the hemodynamic changes in renal artery blood flow and perfusion before and after stent graft placement. METHODS: A total of 51 patients with type B aortic dissection undergoing thoracic endovascular aortic repair between April 2017 and September 2019 were retrospectively recruited. The pre-and post-procedural digital subtraction angiography images were converted into color-coded maps using syngo iFlow for quantitative comparison. Time-intensity curves and related parameters, including the average peak ratio (avg.Pr), average delayed time to peak (avg.dTTP), and average area under the curve ratio (avg.AUCr) of the renal arteries and renal cortex were obtained and analyzed. Wilcoxon signed-rank test was used to compare iFlow parameters before and after endovascular repair. Spearman correlation analyses were performed to study iFlow parameters and renal function parameters and the estimated glomerular filtration rate (eGFR) and blood urea nitrogen (BUN). RESULTS: A total of 102 images including 51 pre-operative and 51 post-operative image datasets were successfully post-processed. Following endovascular repair, syngo iFlow showed a significant 33.0% increase in avg.Pr (P<0.001) and a significant 35.1% increase in avg.AUCr (P<0.001) in the renal artery. Additionally, there was a significant 12.2% decrease in the avg.dTTP (P=0.001), a significant 24.5% increase in avg.Pr (P=0.004), and a significant 38.3% increase in avg.AUCr (P=0.009) in the renal cortex. Spearman correlation analysis showed that after endovascular repair there was a significant correlation between the avg.Pr of the renal artery and eGFR (r=0.30; P=0.0349), the avg.Pr of the renal cortex and eGFR (r=0.30; P=0.0300), and the avg. AUCr of the renal cortex and BUN (r=0.31; P=0.0289). CONCLUSIONS: syngo iFlow provided a novel quantitative method for evaluating renal hemodynamic changes in patients with type B aortic dissection undergoing endovascular treatment. Time-intensity curve parameters may facilitate the intraprocedural evaluation of renal blood flow and perfusion to complement the color-coded map.

3.
Wei Sheng Yan Jiu ; 39(4): 494-7, 2010 Jul.
Artículo en Chino | MEDLINE | ID: mdl-20726247

RESUMEN

OBJECTIVE: To study the type, distribution, the growth and decline of toxins in Nassarius Sp. and the source of toxins to acquire the basis for the control of Nassarius Sp. poisonings. METHODS: The toxicity of Nassarius Sp. was detected by mouse bioassay. The saxitoxin (STX), gonyau toxin (GTX), and tetrodo toxin (TTX) were detected by ELISA and HPLC. RESULTS: Sixty-three poisonous Nassarius Sp. were identified in 127 samples collected from long-term monitoring sites. The detection rate was 49.6%. The detection rate of poisonous Nassarius Sp. was different in varies habitats (P < 0.01). The toxicity of Nassarius Sp. reached a peak in 1991 and hit the rock bottom in 1988. The rate of carrying toxins and the toxicity of detected toxins (STX, GTX and TTX) in Nassarius semiplicatus, Nassa succincta A. Adams and Niotha livescens were high. CONCLUSION: The toxins of Nassarius Sp. in Ningbo City were composed of TTX, STX or GTX, or both TTX and STX. The surveillance proved that some toxins present in Nassarius Sp. in Ningbo City. Poisoning could be caused by eating Nassarius Sp.


Asunto(s)
Moluscos/metabolismo , Saxitoxina/análogos & derivados , Saxitoxina/análisis , Intoxicación por Mariscos , Mariscos , Tetrodotoxina/análisis , Animales , Bioensayo/métodos , China , Gastrópodos/metabolismo , Gastrópodos/patogenicidad , Ratones , Moluscos/patogenicidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...