Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Exp Clin Cancer Res ; 42(1): 276, 2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37865776

RESUMEN

BACKGROUND: Immune-checkpoint inhibitors (ICI) can lead to immune-related adverse events (irAEs) in a significant proportion of patients. The mechanisms underlying irAEs development are mostly unknown and might involve multiple immune effectors, such as T cells, B cells and autoantibodies (AutoAb). METHODS: We used custom autoantigen (AutoAg) microarrays to profile AutoAb related to irAEs in patients receiving ICI. Plasma was collected before and after ICI from cancer patients participating in two clinical trials (NCT03686202, NCT02644369). A one-time collection was obtained from healthy controls for comparison. Custom arrays with 162 autoAg were used to detect IgG and IgM reactivities. Differences of median fluorescent intensity (MFI) were analyzed with Wilcoxon sign rank test and Kruskal-Wallis test. MFI 500 was used as threshold to define autoAb reactivity. RESULTS: A total of 114 patients and 14 healthy controls were included in this study. irAEs of grade (G) ≥ 2 occurred in 37/114 patients (32%). We observed a greater number of IgG and IgM reactivities in pre-ICI collections from patients versus healthy controls (62 vs 32 p < 0.001). Patients experiencing irAEs G ≥ 2 demonstrated pre-ICI IgG reactivity to a greater number of AutoAg than patients who did not develop irAEs (39 vs 33 p = 0.040). We observed post-treatment increase of IgM reactivities in subjects experiencing irAEs G ≥ 2 (29 vs 35, p = 0.021) and a decrease of IgG levels after steroids (38 vs 28, p = 0.009). CONCLUSIONS: Overall, these results support the potential role of autoAb in irAEs etiology and evolution. A prospective study is ongoing to validate our findings (NCT04107311).


Asunto(s)
Autoantígenos , Inhibidores de Puntos de Control Inmunológico , Humanos , Inhibidores de Puntos de Control Inmunológico/efectos adversos , Estudios Prospectivos , Inmunoglobulina G , Inmunoglobulina M , Estudios Retrospectivos
2.
mSystems ; 7(3): e0002222, 2022 06 28.
Artículo en Inglés | MEDLINE | ID: mdl-35642524

RESUMEN

Short-read sequencing can provide detection of multiple genomic determinants of antimicrobial resistance from single bacterial genomes and metagenomic samples. Despite its increasing application in human, animal, and environmental microbiology, including human clinical trials, the performance of short-read Illumina sequencing for antimicrobial resistance gene (ARG) detection, including resistance-conferring single nucleotide polymorphisms (SNPs), has not been systematically characterized. Using paired-end 2 × 150 bp (base pair) Illumina sequencing and an assembly-based method for ARG prediction, we determined sensitivity, positive predictive value (PPV), and sequencing depths required for ARG detection in an Escherichia coli isolate of sequence type (ST) 38 spiked into a synthetic microbial community at varying abundances. Approximately 300,000 reads or 15× genome coverage was sufficient to detect ARGs in E. coli ST38, with comparable sensitivity and PPV to ~100× genome coverage. Using metagenome assembly of mixed microbial communities, ARG detection at E. coli relative abundances of 1% would require assembly of approximately 30 million reads to achieve 15× target coverage. The minimum sequencing depths were validated using public data sets of 948 E. coli genomes and 10 metagenomic rectal swab samples. A read-based approach using k-mer alignment (KMA) for ARG prediction did not substantially improve minimum sequencing depths for ARG detection compared to assembly of the E. coli ST38 genome or the combined metagenomic samples. Analysis of sequencing depths from recent studies assessing ARG content in metagenomic samples demonstrated that sequencing depths had a median estimated detection frequency of 84% (interquartile range: 30%-92%) for a relative abundance of 1%. IMPORTANCE Systematically determining Illumina sequencing performance characteristics for detection of ARGs in metagenomic samples is essential to inform study design and appraisal of human, animal, and environmental metagenomic antimicrobial resistance studies. In this study, we quantified the performance characteristics of ARG detection in E. coli genomes and metagenomes and established a benchmark of ~15× coverage for ARG detection for E. coli in metagenomes. We demonstrate that for low relative abundances, sequencing depths of ~30 million reads or more may be required for adequate sensitivity for many applications.


Asunto(s)
Antibacterianos , Metagenoma , Animales , Humanos , Antibacterianos/farmacología , Farmacorresistencia Bacteriana/genética , Escherichia coli/genética , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Metagenoma/genética , Genoma Bacteriano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...