1.
Appl Radiat Isot ; 69(9): 1181-4, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21550260

RESUMEN

Neutron activation of Sm-152 offers a method of radiolabeling for the in vivo study of oral dose formulations by gamma scintigraphy. Reproducibility measurements are needed to ensure the robustness of clinical studies. 204 enteric-coated guaifenesin core tablets (10mg of Sm(2)O(3)) were irradiated by thermal neutrons to achieve 1 MBq at 48 h. Administered activities were 0.86±0.03 MBq. Good reproducibility (CV=3.5%) was observed over 24 weeks ensuring that volunteer doses were within the dose reference level of 0.8 mSv.


Asunto(s)
Guaifenesina/análogos & derivados , Administración Oral , Guaifenesina/administración & dosificación , Humanos , Marcaje Isotópico , Análisis de Activación de Neutrones , Radioisótopos , Reproducibilidad de los Resultados , Samario
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA