Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
J Cataract Refract Surg ; 47(10): 1314-1318, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33769761

RESUMEN

PURPOSE: To validate and evaluate the use of a new biomechanical index known as the Corvis biomechanical index-laser vision correction (CBI-LVC) as a method for separating stable post-LVC eyes from post-LVC eyes with ectasia. SETTING: 10 clinics from 9 countries. DESIGN: Retrospective, multicenter, clinical study. METHODS: The study was designed with 2 purposes: to develop the CBI-LVC, which combines dynamic corneal response (DCR) parameters provided by a high-speed dynamic Scheimpflug camera (CorVis ST; OCULUS Optikgeräte GmbH) and then to evaluate its ability to detect post-LVC ectasia. The CBI-LVC includes integrated inverse radius, applanation 1 (A1) velocity, A1 deflection amplitude, highest concavity and arclength, deformation amplitude ratio of 2 mm, and A1 arclength in millimeters. Logistic regression with Wald forward stepwise approach was used to identify the optimal combination of DCRs to create the CBI-LVC and then separate stable from LVC-induced ectasia. Eighty percentage of the database was used for training the software and 20% for validation. RESULTS: 736 eyes of 736 patients were included (685 stable LVC and 51 post-LVC ectasia). The receiver operating characteristic curve analysis showed an area under the curve of 0.991 when applying CBI-LVC in the validation dataset and 0.998 in the training dataset. A cutoff of 0.2 was able to separate stable LVC from ectasia with a sensitivity of 93.3% and a specificity of 97.8%. CONCLUSIONS: The CBI-LVC was highly sensitive and specific in distinguishing stable from ectatic post-LVC eyes. Using CBI-LVC in routine practice, along with topography and tomography, can aid the early diagnosis of post-LVC ectasia and allow intervention prior to visually compromising progression.


Asunto(s)
Queratocono , Fenómenos Biomecánicos , Córnea , Topografía de la Córnea , Dilatación Patológica , Elasticidad , Humanos , Estudios Retrospectivos
3.
J Cataract Refract Surg ; 45(7): 977-984, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31029476

RESUMEN

PURPOSE: To evaluate the clinical outcomes, vector parameters, and aberrations between mechanical photorefractive keratectomy (PRK) and transepithelial PRK in eyes with low myopia. SETTING: Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, Korea. DESIGN: Retrospective, comparative case series. METHODS: Eighty-four eyes of 84 patients with low myopia (≤2.00 diopters) were treated with mechanical or transepithelial PRK (41 eyes and 43 eyes, respectively), with the application of a large optical zone (OZ). Visual acuity, manifest refraction, slitlamp evaluation, autokeratometry, corneal topography, and the evaluation of corneal wavefront aberrations were measured preoperatively and at 1, 3, and 6 months after surgery. The efficacy, predictability, vector parameters, corneal aberrations, and safety at 6 months after surgery were compared between the two treatment groups. RESULTS: The mean uncorrected distance visual acuity was comparable, at -0.13 ± 0.05 (SD) and -0.15 ± 0.05, in the mechanical and transepithelial PRK groups, respectively, at 6 months after surgery. The safety and efficacy indices, vector parameters, and aberrometric values were also comparable between the two groups. The OZ was large in both groups (7.09 ± 0.20 mm and 7.12 ± 0.27 mm in the mechanical PRK and transepithelial PRK groups, respectively), and showed no significant difference between groups. The corneal total root-mean-square higher-order aberrations and coma significantly reduced after treatment in both groups, and spherical aberrations significantly decreased after transepithelial PRK. CONCLUSIONS: Mechanical and transepithelial PRK with a large OZ provided effective and safe outcomes for the correction of low myopia without differences in visual acuity and refractive outcomes between procedures.


Asunto(s)
Córnea/cirugía , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Refracción Ocular/fisiología , Agudeza Visual , Adulto , Córnea/patología , Topografía de la Córnea , Femenino , Humanos , Masculino , Persona de Mediana Edad , Miopía/diagnóstico , Miopía/fisiopatología , Estudios Retrospectivos , Microscopía con Lámpara de Hendidura , Resultado del Tratamiento , Adulto Joven
4.
J Cataract Refract Surg ; 44(6): 725-733, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29789156

RESUMEN

PURPOSE: To evaluate the changes in corneal higher-order aberrations (HOAs) after corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) and small-incision lenticule extraction (SMILE). SETTING: Yonsei University College of Medicine and Eyereum Eye Clinic, South Korea. DESIGN: Retrospective case series. METHODS: Medical records of patients having either corneal wavefront-guided transepithelial PRK or small-incision lenticule extraction were examined. The root-mean-square total HOAs, 3rd-order coma aberration, and 4th-order spherical aberration were measured preoperatively and 6 months postoperatively. Independent t tests and analysis of covariance were used to compare changes in corneal HOAs between the 2 groups. RESULTS: The study comprised 77 eyes having corneal wavefront-guided transepithelial PRK and 81 eyes having small-incision lenticule extraction. The total HOAs and spherical aberration increased after transepithelial PRK (all P < .001), whereas coma aberration was stable after transepithelial PRK. The total HOAs, spherical aberration, and coma aberration increased after small-incision lenticule extraction (P < .001 for total HOAs, spherical aberration; P = .004 for coma). At 6 months postoperatively, total HOAs and spherical aberration were significantly larger in the transepithelial PRK group than in the small-incision lenticule extraction group. Coma aberration was larger in the small-incision lenticule extraction group than in the transepithelial PRK group. Spherical aberration induction was significantly smaller in the small-incision lenticule extraction group than in the transepithelial PRK group (P < .001), and coma aberration induction was larger in the small-incision lenticule extraction group than in the transepithelial PRK group (P = .011). CONCLUSIONS: Small-incision lenticule extraction demonstrated that the induction of total HOAs was comparable to corneal wavefront-guided transepithelial PRK, accompanied by smaller spherical aberration induction and larger coma aberration induction. During small-incision lenticule extraction, surgeons should aim to obtain optimum centration for smaller induction of corneal HOAs.


Asunto(s)
Sustancia Propia/cirugía , Aberración de Frente de Onda Corneal/diagnóstico , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Refracción Ocular/fisiología , Agudeza Visual , Adulto , Sustancia Propia/patología , Topografía de la Córnea , Aberración de Frente de Onda Corneal/etiología , Epitelio Corneal , Femenino , Estudios de Seguimiento , Humanos , Masculino , Miopía/diagnóstico , Miopía/fisiopatología , Estudios Retrospectivos , Adulto Joven
5.
Cornea ; 36(10): 1213-1220, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28749894

RESUMEN

PURPOSE: To investigate the effects of combined transepithelial photorefractive keratectomy (tPRK) and accelerated corneal collagen cross-linking (CXL) on visual acuity and refractive outcomes. METHODS: The medical records of 89 eyes (89 patients) undergoing combined tPRK and CXL (tPRK-CXL group) or tPRK alone (tPRK group) were retrospectively analyzed. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity, and manifest refraction spherical equivalent (MRSE) were evaluated preoperatively and 2 weeks, 1, 3, 6, and 12 months after surgery. RESULTS: At 2 weeks after surgery, the tPRK-CXL group had better UDVA than the tPRK group (0.97 ± 0.22 vs. 0.85 ± 0.22, P = 0.015). At 2 weeks and 1 month after surgery, the tPRK-CXL group had a significantly lower spherical error than the tPRK group (0.24 vs. 0.63 D, P = 0.017, for 2 weeks and 0.43 vs. 0.57 D, P = 0.019, for 1 month). At 12 months after surgery, the tPRK-CXL group had a lower spherical error and MRSE than the tPRK group (0.30 vs. 0.44 D, P < 0.001, for the spherical error and 0.17 vs. 0.31 D, P < 0.001, for the MRSE). Both groups had comparable predictability, efficacy, and safety indices at 12 months after surgery. CONCLUSIONS: Combined tPRK and accelerated CXL demonstrated comparable predictability, efficacy, and safety compared with tPRK alone. Combined tPRK and CXL provides better UDVA in the early postoperative period and better refractive outcomes at 12 months postoperatively in terms of spherical error and MRSE.


Asunto(s)
Colágeno/metabolismo , Sustancia Propia/metabolismo , Reactivos de Enlaces Cruzados , Queratocono/terapia , Queratectomía Fotorrefractiva/métodos , Fármacos Fotosensibilizantes/uso terapéutico , Adulto , Terapia Combinada , Topografía de la Córnea , Epitelio Corneal , Femenino , Humanos , Queratocono/tratamiento farmacológico , Queratocono/metabolismo , Queratocono/cirugía , Láseres de Excímeros/uso terapéutico , Masculino , Fotoquimioterapia , Refracción Ocular/fisiología , Estudios Retrospectivos , Riboflavina/uso terapéutico , Resultado del Tratamiento , Rayos Ultravioleta , Agudeza Visual/fisiología , Adulto Joven
6.
J Cataract Refract Surg ; 43(12): 1495-1503, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-29335093

RESUMEN

PURPOSE: To evaluate the changes in biomechanically corrected intraocular pressure (IOP) and new dynamic corneal response parameters measured by a dynamic Scheimpflug analyzer before and after transepithelial photorefractive keratectomy (PRK) and femtosecond laser-assisted laser in situ keratomileusis (LASIK). SETTING: Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. DESIGN: Retrospective case series. METHODS: Medical records of patients having transepithelial PRK or femtosecond-assisted LASIK were examined. The primary outcome variables were biomechanically corrected IOP and dynamic corneal response parameters, including deformation amplitude ratio 2.0 mm, stiffness parameter at first applanation, Ambrósio relational thickness through the horizontal meridian, and integrated inverse radius before the procedure and 6 months postoperatively. RESULTS: Of the 129 patients (129 eyes) in the study, 65 had transepithelial PRK and 64 had femtosecond-assisted LASIK. No significant differences in biomechanically corrected IOP were noted before and after surgery. The deformation amplitude ratio 2.0 mm and integrated inverse radius increased, whereas the stiffness parameter at first applanation and the Ambrósio relational thickness through the horizontal meridian decreased after surgery (P < .001). The changes in deformation amplitude ratio 2.0 mm and integrated inverse radius were smaller in transepithelial PRK than femtosecond-assisted LASIK (P < .001). Using analysis of covariance, with refractive error change or corneal thickness change as a covariate, the changes in deformation amplitude ratio 2.0 mm and integrated inverse radius were smaller in transepithelial PRK than femtosecond-assisted LASIK (P < .001). CONCLUSIONS: The dynamic Scheimpflug analyzer showed stable biomechanically corrected IOP measurement before and after surgery. The changes in dynamic corneal response parameters were smaller with transepithelial PRK than with femtosecond-assisted LASIK, indicating less of a biomechanical effect with transepithelial PRK.


Asunto(s)
Córnea , Presión Intraocular , Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Córnea/fisiología , Córnea/cirugía , Humanos , Periodo Posoperatorio , Estudios Retrospectivos , Tonometría Ocular
7.
J Cataract Refract Surg ; 42(6): 890-8, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27373396

RESUMEN

PURPOSE: To evaluate the effects of photorefractive keratectomy (PRK) combined with corneal wavefront-guided ablation profiles and hyperaspheric ablation profiles on changes in higher-order aberrations (HOAs). SETTING: Yonsei University College of Medicine and Eyereum Clinic, Seoul, South Korea. DESIGN: Comparative observational case series. METHODS: Medical records of patients who had corneal wavefront-guided hyperaspheric PRK, corneal wavefront-guided mild-aspheric PRK, or non-corneal wavefront-guided mild-aspheric PRK were analyzed. The logMAR uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), and changes in corneal aberrations (root-mean-square [RMS] HOAs, spherical aberration, coma) were evaluated 1, 3, and 6 months postoperatively. RESULTS: The records of 61 patients (96 eyes) were reviewed. There was no statistically significant difference in logMAR UDVA or MRSE between the 3 groups at any timepoint. Corneal RMS HOAs were significantly smaller in the corneal wavefront-guided hyperaspheric group and the corneal wavefront-guided mild-aspheric group than in the noncorneal wavefront-guided mild-aspheric group at each timepoint. Corneal spherical aberration was significantly smaller for corneal wavefront-guided hyperaspheric PRK than for noncorneal wavefront-guided mild-aspheric PRK 6 months postoperatively. Changes in corneal spherical aberration (preoperatively and 6 months postoperatively) in corneal wavefront-guided hyperaspheric PRK were significantly smaller than in corneal wavefront-guided mild-aspheric PRK (P = .046). Corneal coma was significantly smaller with corneal wavefront-guided hyperaspheric PRK and corneal wavefront-guided mild-aspheric PRK than with noncorneal wavefront-guided mild-aspheric PRK 3 months and 6 months postoperatively. CONCLUSION: Corneal wavefront-guided hyperaspheric PRK induced less corneal spherical aberration 6 months postoperatively than corneal wavefront-guided mild-aspheric PRK and noncorneal wavefront-guided mild-aspheric PRK. FINANCIAL DISCLOSURE: None of the authors has a financial or proprietary interest in any material or method mentioned.


Asunto(s)
Aberración de Frente de Onda Corneal , Láseres de Excímeros , Miopía/terapia , Queratectomía Fotorrefractiva , Topografía de la Córnea , Humanos , Queratectomía , Estudios Prospectivos , Refracción Ocular , República de Corea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...