J Endovasc Ther ; : 15266028231169183, 2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37102596

RESUMEN

PURPOSE: To report the initial outcomes of physician-modified inner branched endovascular repair (PMiBEVAR) for pararenal aneurysms (PRAs), thoracoabdominal aortic aneurysms (TAAAs), and aortic arch aneurysms in high-surgical-risk patients. MATERIALS AND METHODS: A total of 10 patients (6 men; median age, 83.0 years) treated using PMiBEVAR were enrolled in this retrospective, single-center study. All patients were at high surgical risk because of severe comorbidities (American Society of Anesthesiologists physical status score≥3 or emergency repair). End points were defined as technical success per patient and per vessel (successful deployment), clinical success (no endoleaks postoperatively), in-hospital death, and major adverse events. RESULTS: There were 3 PRAs, 4 TAAAs, and 3 aortic arch aneurysms with 12 renal-mesenteric arteries and 3 left subclavian arteries incorporated by inner branches. The technical success rate was 90.0% (9/10) per patient and 93.3% (14/15) per vessel. The clinical success rate was 90% (9/10). There were 2 in-hospital deaths, unrelated to aneurysms. Paraplegia and shower emboli occurred separately in 2 patients. Three patients experienced prolonged ventilation for 3 days after surgery. Aneurysm sac shrinkage occurred in 4 patients, and aneurysm size stabilized in 1 patient during follow-up, more than 6 months later. None of the patients required intervention. CONCLUSION: PMiBEVAR is a feasible approach for treating complex aneurysms in high-surgical-risk patients. This technology may complement the existing technology in terms of improved anatomical adaptability, no time delay and practicability in many countries. However, long-term durability remains undetermined. Further large-scale and long-term studies are needed. CLINICAL IMPACT: This is the first clinical study to investigate outcomes of physician-modified inner branched endovascular repair (PMiBEVAR). PMiBEVAR for treating pararenal aneurysm, thoracoabdominal aortic aneurysm, or aortic arch aneurysm is a feasible procedure. This technology is likely to complement existing technology in terms of improved anatomical adaptability (compared to off-the-shelf devices), no time delay (compared to custom-made devices), and the potential to be performed in many countries. On the other hand, surgery time varied greatly depending on the case, suggesting a learning curve and the need for technological innovation to perform more consistent surgeries.

3.
Artículo en Japonés | MEDLINE | ID: mdl-31548466

RESUMEN

PURPOSE: Computed tomography (CT) attenuation correction of myocardial perfusion in single-photon emission computed tomography (SPECT) /CT systems is possibility of misregistration between emission and transmission scans. This study aimed to evaluate the influence of misregistration using a polar map of 17 segments model. METHODS: Using the fusion software, we assessed the magnitude and direction of misregistration in 200 consecutive myocardial perfusion SPECT images with 99mTechnetium (99mTc) tetrofosmin. After registration, CT data was shifted by ±1, ±2, and ±3 pixels along the cephalad/caudal, dorsal/ventral, and left/right axes, respectively. The registered image was compared with the shifted image. RESULTS: Misregistration between the SPECT and CT images occurred by 1-2 pixels in 127 cases (63.5%) and by 2 or more pixels in four cases (2%); the maximum misregistration was 1.2±0.4 pixels on average. The polar map scoring was most significantly affected by 3 pixel ventral shift. A ventral shift of 1 pixel affected the scores for the anterolateral and inferolateral segments, whereas a caudal shift of 1 pixel affected the scores for the anterior segment. CONCLUSION: Since the 17 segments model can evaluate the position more precisely than the five segments model, it is possible to evaluate up to 1 pixel misregistration.


Asunto(s)
Artefactos , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Sensibilidad y Especificidad , Tecnecio , Tomografía Computarizada de Emisión de Fotón Único/normas , Tomografía Computarizada por Rayos X/normas
4.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 69(8): 873-8, 2013 Aug.
Artículo en Japonés | MEDLINE | ID: mdl-23965788

RESUMEN

BACKGROUND: In CARTOMERGE(®) for treatment of atrial fibrillation (AF) by ablation, by integrating electro anatomical map (EAM) and left atrium three-dimensional computed tomography angiography (3D-CTA) images, identification of the ablation points is simplified and the procedure can be made carried out more rapidly. However, the influence that heart rhythm, breathing and arm position during CT scanning have on registration accuracy and fluoroscopy time is not clear. PURPOSE: To clarify the influence on registration accuracy and fluoroscopy time of heart rhythm, breathing and arm position during CT scanning. METHODS: The patients were CT-scanned during both sinus rhythm (SR) and AF in each study subject. We evaluated the registration accuracy of images reconstructed between the cardiac cycle and assessed the registration accuracy and fluoroscopy time of images obtained during inspiratory breath-hold, expiratory breath-hold and up and down position of the arm. RESULTS: Although the registration accuracy of the EAM image and left atrium 3D-CTA image showed a significant difference during SR, no significant difference was seen during AF. Expiratory breath-hold and down position of the arm resulted in the highest registration accuracy and the shortest fluoroscopy time. However, arm position had no significant effect on registration accuracy. CONCLUSIONS: Heart rhythm and breathing during CT scanning have a significant effect on the registration accuracy of EAM images, left atrium 3D-CTA images, and fluoroscopy time.


Asunto(s)
Brazo/fisiología , Fibrilación Atrial/terapia , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter , Frecuencia Cardíaca , Respiración , Tomografía Computarizada por Rayos X , Angiografía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Femenino , Fluoroscopía , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad