Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Orthop Traumatol Surg Res ; 108(2): 103046, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34487909

RESUMEN

BACKGROUND: Degenerative rotator cuff tear is a frequent and multifactorial pathology. The role of bone morphology of the greater tuberosity and lateral acromion has been validated, and can be measured with two plain radiographic markers on true anteroposterior views: the greater tuberosity angle (GTA) and the critical shoulder angle (CSA). However, the interdependence of both markers remains unknown, as well as their relationship with the level of professional and sports activities involving the shoulder. The aim of this prospective comparative study was to describe the correlation between the GTA and CSA in patients with degenerative rotator cuff tears. HYPOTHESIS: GTA and CSA are independent factors from one another and from demographic factors, such as age, dominance, sports, or professional activities. PATIENT AND METHODS: All patients presenting to a shoulder specialized clinic were assigned to two groups. The first consisted of patients with a symptomatic degenerative rotator cuff tear visible on MRI and the control group consisted of patients with any other shoulder complaints and no history or visible imaging of any rotator cuff lesion. RESULTS: There were 51 shoulders in 49 patients in the rotator cuff tear group (RCT) and 53 shoulders in 50 patients in the control group. Patient demographics were similar in both groups. Mean GTA was 72.1°±3.7 (71.0-73.1) in the RCT group and 64.0°±3.3 (63.1-64.9) in the control group (p<0.001). Mean CSA was 36.7°±3.7 (35.7-37.8) in the RCT group, and 32.1°±3.7 (31.1-33.1) in the control group (p<0.001). A summation of GTA and CSA values over 103° increased the odds of having a rotator cuff tear by 97-fold (p<0.001). There was no correlation between GTA and CSA, nor between GTA or CSA and age, sex, tear size, or dominance. Patients with different levels of professional and sports activities did not have significantly different GTA or CSA values. CONCLUSION: GTA and CSA are independent radiologic markers that can reliably predict the presence of a degenerative rotator cuff tear. A sum of both values over 103° increases the odds of having a rotator cuff tear by 97-fold. These markers are not correlated with patient demographic or environmental factors, suggesting that the variability of the native acromion and greater tuberosity morphology may be individual risk factors for rotator cuff tear. LEVEL OF EVIDENCE: II; diagnostic study.


Asunto(s)
Lesiones del Manguito de los Rotadores , Articulación del Hombro , Acromion/diagnóstico por imagen , Humanos , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/patología , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/patología , Rotura , Hombro , Articulación del Hombro/anatomía & histología
2.
J Shoulder Elbow Surg ; 30(7): 1553-1560, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33421559

RESUMEN

BACKGROUND: Hematoma formation and the need for blood transfusions are commonly reported complications after shoulder arthroplasty. Tranexamic acid (TXA) has been widely used in hip and knee arthroplasty to decrease perioperative blood loss. The role of TXA is still being established in shoulder arthroplasty. MATERIALS AND METHODS: We conducted a double-blind randomized controlled trial comparing intravenous TXA vs. placebo in 60 patients undergoing primary anatomic or reverse shoulder arthroplasty. Of these patients, 29 received a placebo whereas 31 received a single dose of 2 g of intravenous TXA. Patient demographic characteristics, as well as drain tube output, blood loss, hematoma formation, transfusion requirement, length of hospital stay, and pain score, were recorded. Patients were followed up for 12 weeks to assess for complications. RESULTS: Patients who received TXA had a lower drain tube output at all time points: 41 mL vs. 133 mL at 6 hours, 75 mL vs. 179 mL at 12 hours, and 94 mL vs. 226 mL at 24 hours (P < .001 for all). They also had a higher postoperative hemoglobin (Hb) level (12.3 g/dL vs. 11.4 g/dL, P = .009), lower change in Hb level (1.7 g/dL vs. 2.3 g/dL, P = .011), lower total Hb loss (0.078 g vs. 0.103 g, P = .042), lower blood volume loss (0.55 L vs. 0.74 L, P = .021), higher postoperative hematocrit level (36.7% vs. 34.6%, P = .020), and lower hematocrit change (5.4% vs. 7.6%, P = .022). There was no significant difference in pain score or length of hospital stay, and no patients required a transfusion. CONCLUSION: A single dose of 2 g of intravenous TXA decreases blood loss and drain tube output in primary anatomic and reverse arthroplasty of the shoulder. No differences were detected in the occurrence of complications, need for transfusion, pain score, or length of hospital stay. With the mounting evidence now available, patients undergoing elective primary shoulder arthroplasty should be given intravenous TXA to decrease perioperative blood loss.


Asunto(s)
Antifibrinolíticos , Artroplastía de Reemplazo de Hombro , Ácido Tranexámico , Artroplastía de Reemplazo de Hombro/efectos adversos , Pérdida de Sangre Quirúrgica/prevención & control , Transfusión Sanguínea , Humanos
3.
J Shoulder Elbow Surg ; 29(12): 2626-2631, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33190761

RESUMEN

BACKGROUND: Extra-articular fluid extravasation is a known complication during shoulder arthroscopy. The risk and amount of extravasation to a large degree is dependent on the fluid pressure delivered to the surgical site. Accurate measurement, knowledge, and control of the pressure delivered is thus important to surgeons, anesthetists, and the patient. The purpose of this study was to compare the pressure measurement accuracy of 3 arthroscopic fluid pumps, with 2 of them having 2 different settings. METHODS: Twenty-five patients (n = 5 per group) undergoing shoulder arthroscopy were selected. Three different arthroscopic fluid pumps (ConMed 24K, Stryker Crossflow, Arthrex Dual Wave) were tested in 5 different operational settings (Stryker, standard and dynamic mode; ConMed, with and without TIPS; Arthrex Dual Wave). In each operation, the set pump pressures and the subsequently delivered intra-articular surgical site fluid pressures were measured by a spinal needle connected to an anesthetic standard pressure transducer attached to the anesthetic machine. Independent measures of the surgical site pressures were obtained before multiple portals were created or extravasation had occurred. Measurements were taken at the beginning of surgery. RESULTS: Measurements of the mean intra-articular pressure were found to not be significantly different from the set pressure for the ConMed 24K with TIPS (0.98 ± 0.02-fold) and Stryker Crossflow in standard mode (0.98 ± 0.02-fold). However, actual pressure was significantly greater than the set pressure for the ConMed 24K without TIPS (by 1.30 ± 0.13-fold), Stryker Crossflow in dynamic mode (by 1.82 ± 0.08-fold), and Arthrex Dual Wave (by 2.19 ± 0.06-fold). CONCLUSION: Independently measured intra-articular pressure can be more than double the set pressure for some arthroscopic pumps. Measuring intra-articular pressure can thus aid in adjusting the set pressure. This could minimize the risk of intraoperative complications.


Asunto(s)
Artroscopía/efectos adversos , Artroscopía/instrumentación , Articulación del Hombro , Líquido Sinovial/fisiología , Irrigación Terapéutica/efectos adversos , Irrigación Terapéutica/instrumentación , Artroscopía/métodos , Humanos , Presión , Articulación del Hombro/fisiopatología , Articulación del Hombro/cirugía , Irrigación Terapéutica/métodos
4.
Arthroscopy ; 36(3): 708-713, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31727418

RESUMEN

PURPOSE: To evaluate the viscoelastic properties of 4 commercially available cord-like sutures and 2 commercially available suture tapes when subjected to physiological loads, as well as to compare them with each other and to identify the clinically most desirable combination of suture material properties. METHODS: Six suture materials (Ethibond, FiberWire, FiberTape, Orthocord, Ultrabraid, and Ultratape) underwent creep testing (n = 7, 60 N, 10 minutes) to determine specimen stiffness, initial elongation at 60 N of load, static creep (during 10 minutes of loading), and relaxed elongation (material recovery 3 minutes after removal of load). Furthermore, cyclic testing (n = 7, 10-45 N, 0.5 Hz, 500 cycles) was carried out to determine dynamic creep, peak-to-peak displacement, and relaxed elongation. Mechanical testing was conducted on a material testing machine in 37°C phosphate-buffered saline solution. RESULTS: FiberTape showed the greatest stiffness (23.9 ± 3.2 N/mm, P < .001), the smallest amounts of static (0.38 ± 0.10 mm, P < .001) and dynamic (0.16 ± 0.09 mm, P = .003) creep, and the smallest peak-to-peak displacement (0.20 ± 0.02 mm, P < .001). FiberTape and FiberWire showed the smallest initial elongation (1.17 ± 0.17 mm and 1.63 ± 0.25 mm, respectively; P < .001). Ultrabraid showed the greatest relaxed elongation, both statically (4.73 ± 0.73 mm, P < .001) and dynamically (4.18 ± 0.83 mm, P = .002). CONCLUSIONS: FiberTape consistently displayed less creep, greater stiffness, and less extensibility than the other suture types. Ultrabraid showed the largest amount of relaxed elongation on both static and dynamic testing. CLINICAL RELEVANCE: When considering high stiffness in combination with low initial extension and low static creep to be ideal parameters to achieve optimal initial construct stability and considering low dynamic creep in combination with low peak-to-peak displacement to be ideal conditions for the repetitive loading of the construct during the healing process, tapes seem to be superior to cord-like sutures for performing rotator cuff repair.


Asunto(s)
Artroscopía , Ensayo de Materiales , Articulación del Hombro/cirugía , Suturas , Elasticidad , Diseño de Equipo , Humanos , Tereftalatos Polietilenos , Estrés Mecánico , Viscosidad
5.
J Shoulder Elbow Surg ; 27(10): 1809-1815, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29778592

RESUMEN

BACKGROUND: Most glenoid version measurement methods have been validated on 3-dimensionally corrected axial computed tomography (CT) slices at the mid glenoid. Variability of the vault according to slice height and angulation has not yet been studied and is crucial for proper surgical implant positioning. The aim of this study was to analyze the variation of the glenoid vault compared with the Friedman angle according to different CT slice heights and angulations. The hypothesis was that the Friedman angle would show less variability. MATERIALS AND METHODS: Sixty shoulder CT scans were retrieved from a hospital imaging database and were reconstructed in the plane of the scapula. Seven axial slices of different heights and coronal angulations were selected, and measurements were carried out by 3 observers. RESULTS: Mid-glenoid mean version was -8.0° (±4.9°; range, -19.6° to +7.0°) and -2.1° (±4.7°; range, -13.0° to +10.3°) using the vault method and Friedman angle, respectively. For both methods, decreasing slice height or angulation did not significantly alter version. Increasing slice height or angulation significantly increased anteversion for the vault method (P < .001). Both interobserver reliability and intraobserver reliability were significantly higher using the Friedman angle. CONCLUSION: Version at the mid and lower glenoid is similar using either method. The vault method shows less reliability and more variability according to slice height or angulation. Yet, as it significantly differs from the Friedman angle, it should still be used in situations where maximum bone purchase is sought with glenoid implants. For any other situation, the Friedman angle remains the method of choice.


Asunto(s)
Cavidad Glenoidea/diagnóstico por imagen , Imagenología Tridimensional , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Escápula/diagnóstico por imagen , Adulto Joven
6.
J Shoulder Elbow Surg ; 27(8): 1415-1421, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29703680

RESUMEN

BACKGROUND: The implication of scapular morphology in rotator cuff tears has been extensively studied. However, the role of the greater tuberosity (GT) should be of equal importance. The aim of this study was to propose a new radiographic marker, the GT angle (GTA), which measures the position of the GT in relation to the center of rotation of the humeral head. The hypothesis was that a higher angle value would be associated with a higher likelihood in detecting a rotator cuff tear. METHODS: During 1 year, patients were prospectively recruited from a single institution specialized shoulder clinic in 2 different groups. The patient group consisted of individuals with a degenerative rotator cuff tear involving at least the supraspinatus. The control group consisted of individuals with no rotator cuff pathology. Individuals in both groups with congenital, post-traumatic, or degenerative alterations of the proximal humerus were excluded. The GTA was measured on an anteroposterior shoulder x-ray image with the arm in neutral rotation by 3 observers at 2 different times. RESULTS: The study recruited 71 patients (33 patients, 38 controls). Mean GTA value was 72.5° (range, 67.6°-79.2°) in patients and 65.2° (range, 55.8°-70.5°) for controls (P <.001). A value above 70° resulted in 93-fold higher odds of detecting a rotator cuff tear (P <.001). Interobserver and intraobserver reliability were high. CONCLUSIONS: GT morphology is implicated in rotator cuff tears. The GTA is a reliable radiographic marker, with more than 70° being highly predictive in detecting such lesions.


Asunto(s)
Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Rotación , Adulto Joven
7.
J Bone Joint Surg Am ; 98(20): 1722-1728, 2016 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-27869623

RESUMEN

BACKGROUND: Propionibacterium acnes is a common pathogen identified in postoperative shoulder infection. It has been shown to be present in culture specimens during primary shoulder arthroplasty; however, recent work has suggested that it is most likely to be a contaminant. Our aim was to identify the potential sources of contamination in shoulder arthroplasty. METHODS: Tissue swabs were obtained for microbiological analysis from consecutive patients undergoing primary shoulder arthroplasty. Routine surgical technique was maintained, and 5 specimens were taken from different sites: (1) the subdermal layer, (2) the tip of the surgeon's glove, (3) the inside scalpel blade (used for deeper incision), (4) the forceps, and (5) the outside scalpel blade (used for the skin incision). RESULTS: Forty patients (25 female patients and 15 male patients) were included. Thirteen (33%) of the 40 patients had at least 1 culture specimen positive for P. acnes. Two (8%) of the 25 female patients and 11 (73%) of the 15 male patients had ≥1 culture specimen positive for P. acnes. The most common site of growth of P. acnes was the subdermal layer (12 positive samples), followed by the forceps (7 positive samples), the tip of the surgeon's glove (7 positive samples), the outside scalpel blade (4 positive samples), and the inside scalpel blade (1 positive sample). There were 27 of 75 swabs that were positive on culture for P. acnes in male patients compared with 4 of 125 swabs in female patients. Male patients had 66 times (95% confidence interval, 6 to 680 times) higher odds of having a positive culture indicating subdermal colonization compared with female patients (p < 0.001). CONCLUSIONS: P. acnes is a common contaminant of the surgical field in primary shoulder arthroplasty. The subdermal layer may be the source of this contamination, and the prevalence of P. acnes in the surgical wound may be due to the surgeon's manipulation with gloves and instruments. Our findings are consistent with those regarding the increased rates of P. acnes bacterial load and intraoperative growth in male patients compared with female patients. CLINICAL RELEVANCE: P. acnes is likely to be spread throughout the surgical field from the subdermal layer via soft-tissue handling by the surgeon and instruments. Strategies need to be utilized to minimize this contact and to reduce the chance of colonization.


Asunto(s)
Artroplastía de Reemplazo de Hombro/efectos adversos , Infecciones por Bacterias Grampositivas/etiología , Propionibacterium acnes/aislamiento & purificación , Articulación del Hombro/cirugía , Piel/microbiología , Anciano , Anciano de 80 o más Años , Femenino , Infecciones por Bacterias Grampositivas/microbiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/microbiología , Articulación del Hombro/microbiología
8.
J Shoulder Elbow Surg ; 24(8): 1206-11, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25700640

RESUMEN

BACKGROUND: Propionibacterium acnes is a recognized pathogen in postoperative shoulder infections. A recent study reported growth of P acnes in 42% of glenohumeral joints in primary shoulder arthroplasty, concluding that P acnes may cause shoulder osteoarthritis. Whether these results reflect true bacterial infection or specimen contamination is unclear. Our prospective study aimed to determine the rate of P acnes infection in arthritic shoulders using a strict specimen collection technique. METHODS: We used modified Oxford protocol to collect tissue specimens from the glenohumeral joint of 32 consecutive patients undergoing primary shoulder arthroplasty. Specimens were cultured specifically for P acnes. Diagnosis of P acnes infection required 2 or more positive cultures and histopathology compatible with infection. RESULTS: Three of 32 patients had a positive culture for P acnes. Overall, 3.125% of specimens grew P acnes without histologic evidence of infection. There were no patients with P acnes infection. The difference in culture rates between patients with idiopathic osteoarthritis and those with a predisposing cause for osteoarthritis was not significant. CONCLUSIONS: We found a low rate of positive cultures for P acnes, but no P acnes infection and no difference between types of osteoarthritis. These results do not support a cause-and-effect relationship between P acnes and osteoarthritis. The differing results from previous studies are likely explained by our strict specimen collection technique, reflecting different rates of contamination rather than infection. That P acnes contamination occurs in primary shoulder arthroplasty is concerning. Further studies are needed to assess the rates of contamination in shoulder surgery, its clinical effect, and to determine optimal antibiotic prophylaxis.


Asunto(s)
Propionibacterium acnes/aislamiento & purificación , Articulación del Hombro/microbiología , Anciano , Anciano de 80 o más Años , Artritis/cirugía , Artroplastia de Reemplazo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Articulación del Hombro/cirugía
9.
Orthop Clin North Am ; 46(1): 105-11, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25435039

RESUMEN

Recurrent anterior shoulder instability is common in contact athletes and the high-energy injuries seen in this group make them more prone to bone loss. Athletes with recurrent instability and associated bone loss have high failure rates when treated with a soft tissue reconstruction procedure. Therefore it is preferred to manage recurrent instability in contact athletes with the Latarjet-Patte procedure. In this article, the authors describe their technique. They have found this procedure to be safe and effective, with very low recurrence and early return to sport. A meticulous surgical technique is important to avoid intraoperative and postoperative complications.


Asunto(s)
Traumatismos en Atletas/cirugía , Inestabilidad de la Articulación/cirugía , Procedimientos Ortopédicos/métodos , Luxación del Hombro/cirugía , Articulación del Hombro , Traumatismos en Atletas/diagnóstico , Traumatismos en Atletas/etiología , Cavidad Glenoidea/patología , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología , Recurrencia , Luxación del Hombro/diagnóstico , Luxación del Hombro/etiología
11.
J Shoulder Elbow Surg ; 22(4): 485-8, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22929584

RESUMEN

BACKGROUND: Recent studies have reported the theoretic amount of coracoid graft available for harvesting with the Latarjet procedure. Our aim was to investigate the actual dimensions of coracoid grafts harvested using a standardized technique. We also hoped to confirm previous recommendations regarding placement of the inferior glenoid drill hole to avoid lateral overhang of the graft. MATERIALS AND METHODS: Intraoperative measurements were taken after coracoid graft harvesting and preparation during the Latarjet procedure. Specifically, we measured the length of coracoid, thickness of coracoid, distance from the inferior drill hole to the lateral margin of the graft, distance between drill holes, width at the level of the superior drill hole, and width at the level of the inferior drill hole. RESULTS: Data were collected from 76 Latarjet procedures (67 men, 9 women). Patients were an average age of 28.7 years (range 16-67 years). Mean measurements were length of coracoid graft, 26.4 ± 2.9 mm; thickness, 9.3 ± 1.4 mm; distance from the edge of the inferior drill hole to the lateral margin of the graft, 5.7 ± 1.1 mm; distance between drill holes, 7.8 ± 1.9 mm; width at the level of the superior drill hole, 14.1 ± 1.8 mm; and width at the level of the inferior drill hole, 13.3 ± 1.8 mm. CONCLUSIONS: Using a standardized surgical technique that does not violate the coracoclavicular ligaments, a coracoid graft greater than 25 mm can routinely be harvested for the Latarjet procedure. The inferior glenoid drill hole should typically be placed at least 7 mm from the glenoid margin to avoid lateral overhang.


Asunto(s)
Procedimientos Ortopédicos/métodos , Escápula/trasplante , Articulación del Hombro/cirugía , Adolescente , Adulto , Anciano , Trasplante Óseo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Escápula/cirugía , Recolección de Tejidos y Órganos , Trasplantes , Adulto Joven
12.
Tissue Cell ; 45(1): 77-82, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23245384

RESUMEN

Perlecan is a widely distributed, heparan sulphate proteoglycan with roles in the sequestration of FGFs, PDGF, VEGF through which it promotes cell proliferation and matrix production. Perlecan also stabilises extracellular matrices through interaction with a diverse range of matrix components. This study examined the distribution of perlecan in an ovine partial transection tendinopathy model. In normal tendon, perlecan was immunolocalised to small blood vessels in intrafascicular regions in the tendon-bone and muscle-tendon attachments and to linear arrays of oval shaped tenocytes in the tendon mid-region. Partial transection in the mid-tendon region significantly increased perlecan accumulation within the fascicles, in granulation tissue filling the transection site and in the tendon-bone and tendon-muscle attachments. The accumulation of perlecan in the transected tendon and its known roles in matrix stabilisation and cell proliferation indicate possible roles in tendon remodelling and repair. Perlecan domain-1 has been used as a growth factor delivery vehicle for FGF-2, BMP-2 and BMP-7 in regenerative medicine but has yet to be evaluated in infraspinatus tendon repair. A better understanding of perlecan's contributions to pathobiological processes in remodelling tendon may be useful in such regenerative strategies in the future.


Asunto(s)
Proteoglicanos de Heparán Sulfato/metabolismo , Oveja Doméstica/metabolismo , Tendinopatía/metabolismo , Tendones/metabolismo , Animales , Proliferación Celular , Modelos Animales de Enfermedad , Matriz Extracelular/metabolismo , Factor 2 de Crecimiento de Fibroblastos/metabolismo , Humanos , Factor de Crecimiento Derivado de Plaquetas/metabolismo , Medicina Regenerativa , Manguito de los Rotadores/irrigación sanguínea , Manguito de los Rotadores/metabolismo , Manguito de los Rotadores/patología , Oveja Doméstica/fisiología , Tendinopatía/patología , Tendones/irrigación sanguínea , Tendones/crecimiento & desarrollo , Factores de Crecimiento Endotelial Vascular/metabolismo , Cicatrización de Heridas/fisiología
13.
Orthopedics ; 35(4): e479-85, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22495846

RESUMEN

The results of anatomic total shoulder arthroplasty and reverse shoulder arthroplasty have previously been reported separately. Although the indications differ, scenarios exist in which a patient may have a total shoulder arthroplasty on 1 shoulder and a reverse shoulder arthroplasty on the contralateral shoulder.Between 1992 and 2009, twelve patients underwent bilateral sequential primary shoulder arthroplasty with a total shoulder arthroplasty on 1 side and reverse shoulder arthroplasty on the contralateral side. Constant score, American Shoulder and Elbow Surgeons (ASES) score, subjective shoulder value, and patient satisfaction were obtained a minimum 1 year postoperatively. Mean postoperative Constant score was 77 after total shoulder arthroplasty and 73 after reverse shoulder arthroplasty (P<.2488). Mean postoperative active forward flexion was similar after total shoulder arthroplasty compared with reverse shoulder arthroplasty (P=.8910). Greater external rotation at the side (43° vs 12°; P<.0001) and internal rotation (T8 vs L1; P<.0001) were observed after total shoulder arthroplasty. Mean ASES score was 89.6 after total shoulder arthroplasty compared with 82.4 after reverse shoulder arthroplasty (P=.0125). Patient satisfaction was 92% for both prostheses, and mean subjective shoulder value was similar (85.4% vs 82.5%; P=.6333).Bilateral shoulder arthroplasty performed with a total shoulder arthroplasty and reverse shoulder arthroplasty on opposite shoulders can provide good functional outcome and high patient satisfaction. Although range of motion is better following total shoulder arthroplasty, no difference was observed in final Constant score or subjective patient assessment.


Asunto(s)
Artroplastia/métodos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/cirugía , Osteoartritis/diagnóstico , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rango del Movimiento Articular , Estudios Retrospectivos , Resultado del Tratamiento
14.
J Bone Joint Surg Am ; 94(8): 685-93, 2012 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-22419408

RESUMEN

BACKGROUND: Secondary rotator cuff dysfunction is a recognized complication following shoulder arthroplasty. We hypothesized that the rate of secondary rotator cuff dysfunction would increase with follow-up and result in less satisfactory clinical and radiographic outcomes. Our aim was to investigate the rate of secondary rotator cuff dysfunction following shoulder arthroplasty for primary osteoarthritis and identify factors associated with the dysfunction. METHODS: Between 1991 and 2003, in ten European centers, 704 total shoulder arthroplasties were performed for primary glenohumeral osteoarthritis. Complete radiographic and clinical follow-up of more than five years was available for 518 shoulders. The diagnosis of secondary rotator cuff dysfunction was made when moderate or severe superior subluxation of the prosthetic humeral head was present on radiographs. Multivariate logistic regression identified factors associated with the development of rotator cuff dysfunction. Kaplan-Meier survivorship analysis was performed, with the end point being secondary rotator cuff failure. Clinical outcome was assessed with use of the Constant score, a subjective assessment of the shoulder, and an evaluation of shoulder motion. RESULTS: At an average of 103.6 months (range, sixty to 219 months) after shoulder arthroplasty, the rate of secondary rotator cuff dysfunction was 16.8%. Survivorship free of secondary cuff dysfunction was 100% at five years, 84% at ten years, and 45% at fifteen years. Duration of follow-up (p < 0.0001), implantation of the glenoid implant with superior tilt (p < 0.001), and fatty infiltration of the infraspinatus muscle (p < 0.05) were risk factors for the development of secondary cuff dysfunction. Patients with secondary rotator cuff dysfunction had significantly worse clinical outcomes (Constant score, subjective assessment, and range of motion; p < 0.0001) and radiographic results (radiolucent line score, radiographic loosening, glenoid component migration; p < 0.0001). CONCLUSIONS: In this study, rates of secondary rotator cuff dysfunction with moderate or severe superior subluxation of the prosthetic humeral head increased with the duration of follow-up and significantly influenced the clinical and radiographic outcome of total shoulder arthroplasty performed for primary glenohumeral osteoarthritis. Preoperative fatty infiltration of the infraspinatus muscle and implantation of the glenoid component with superior tilt were prognostic factors.


Asunto(s)
Artroplastia de Reemplazo/efectos adversos , Osteoartritis/cirugía , Manguito de los Rotadores/fisiopatología , Luxación del Hombro/etiología , Articulación del Hombro/cirugía , Tendinopatía/etiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Falla de Prótesis , Lesiones del Manguito de los Rotadores , Articulación del Hombro/fisiopatología
15.
J Bone Joint Surg Am ; 94(2): 145-50, 2012 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-22258001

RESUMEN

BACKGROUND: The aim of this study was to radiographically analyze the long-term glenoid migration patterns following total shoulder arthroplasty to better understand the factors responsible for loosening. METHODS: Complete radiographic follow-up of more than five years was available for 518 total shoulder arthroplasties performed for primary glenohumeral osteoarthritis with use of an anatomically designed prosthesis with a cemented, all-polyethylene, keeled glenoid component. Radiographs were assessed for humeral head subluxation, periprosthetic radiolucent lines, and shifting of the position of the glenoid component. The type of migration of the glenoid was defined according to the direction of tilt, or as subsidence in the case of medial migration. RESULTS: Definite radiographic evidence of glenoid loosening was observed in 166 shoulders (32%) and was characterized by radiolucency of ≥2 mm over the entire bone-cement interface in thirty shoulders and by a migration of the glenoid component (shift or subsidence) in 136 shoulders. Three predominant patterns of migration of the glenoid component were observed: superior tilting in fifty-two shoulders (10%), subsidence in forty-one shoulders (7.9%), and posterior tilting in thirty-three shoulders (6.4%). Superior tilting of the glenoid was associated with three risk factors: low positioning of the glenoid component, superior tilt of the glenoid component on the immediate postoperative coronal plane radiographs, and superior subluxation of the humeral head (p < 0.05 for all). Subsidence of the glenoid component was associated with the use of reaming to optimize the seating and positioning of the glenoid component (p < 0.001). Posterior tilting of the glenoid component was associated with preoperative posterior subluxation (i.e., a Walch type-B glenoid) and with excessive reaming (p < 0.01 for both). CONCLUSIONS: The three patterns of migration observed in this study underscore the potential importance of the supporting bone beneath the glenoid component. In some shoulders, use of a keel or pegs to provide fixation of a polyethylene component in the absence of good support from subchondral bone may not be sufficient to resist compressive and eccentric forces, resulting in loosening. Preserving subchondral bone may be important for long-term longevity of the glenoid component.


Asunto(s)
Artroplastia de Reemplazo/instrumentación , Inestabilidad de la Articulación/etiología , Prótesis Articulares , Osteoartritis/cirugía , Polietileno , Articulación del Hombro/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo/efectos adversos , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Radiografía , Estudios Retrospectivos , Articulación del Hombro/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento
16.
Spine (Phila Pa 1976) ; 37(1): 18-25, 2012 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-22179320

RESUMEN

STUDY DESIGN: An investigation of mechanical destabilization of the lumbar ovine intervertebral disc (IVD) inducing IVD degeneration (IVDD) as determined by multiparameter outcome measures (magnetic resonance imaging [MRI], IVD composition, biomechanical testing, gene profiling, immunohistochemistry, and immunoblotting). OBJECTIVE: To assess the effect of IVD mechanical destabilization on matrix protein and metalloproteinase gene expression to investigate the pathophysiological mechanisms of lumbar IVDD. SUMMARY OF BACKGROUND DATA: Several earlier studies have used annular transection to induce IVDD in sheep, but none have optimized or validated the most appropriate lesion size. METHODS: The annulus fibrosus (AF) incision inducing maximal change in IVD biomechanics was applied to L1-L2, L3-L4, and L5-L6 discs in vivo to compare with a sham procedure at 3 months post operation. IVDs were evaluated by MRI, biomechanics, histopathology, proteoglycan and collagen content, gene expression, and aggrecan proteolysis by Western blotting. RESULTS: Significant changes were observed in lesion (6 × 20 mm(2)) compared with sham IVDs at 3 months post operation: reduced disc height on MRI; increased neutral zone in biomechanical testing; depleted proteoglycan and collagen content in the nucleus pulposus (NP) and lesion half of the AF but not in the contralateral AF; increased messenger RNA for collagen I and II, aggrecan, versican, perlecan, matrix metalloproteinase (MMP)-1 & 13, and ADAMTS-5, in the lesion-site AF and NP but not in the contralateral AF. ADAMTS-4 messenger RNA was increased in the lesion-site AF but decreased in the NP. Despite an upregulation in MMPs, there was no change in MMP- or ADAMTS-generated aggrecan neoepitopes in any region of the IVD in lesion or sham discs. CONCLUSION: Lumbar IVDD was reproducibly induced with a 6 × 20 mm(2) annular lesion, with focal dysregulation of MMP gene expression, cell cloning in the inner AF, loss of NP aggrecan, and disc height. Loss of aggrecan from the NP was not attributable to increased proteolysis in the interglobular domain by MMPs or ADAMTS.


Asunto(s)
Degeneración del Disco Intervertebral/metabolismo , Disco Intervertebral/metabolismo , Metaloproteasas/metabolismo , Proteínas ADAM/genética , Proteínas ADAM/metabolismo , Proteína ADAMTS4 , Animales , Colágeno/genética , Colágeno/metabolismo , Modelos Animales de Enfermedad , Expresión Génica , Perfilación de la Expresión Génica , Disco Intervertebral/lesiones , Disco Intervertebral/patología , Degeneración del Disco Intervertebral/etiología , Degeneración del Disco Intervertebral/patología , Vértebras Lumbares/patología , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/cirugía , Imagen por Resonancia Magnética , Masculino , Metaloproteasas/genética , Orquiectomía , Procolágeno N-Endopeptidasa/genética , Procolágeno N-Endopeptidasa/metabolismo , Proteoglicanos/genética , Proteoglicanos/metabolismo , ARN Mensajero/metabolismo , Ovinos , Estrés Mecánico
17.
Curr Rev Musculoskelet Med ; 4(4): 183-90, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22021013

RESUMEN

The reverse shoulder arthroplasty emerged as a potential solution for those patients who could not be managed effectively with a conventional total shoulder arthroplasty. Grammont revolutionized the design by medializing and distalizing the center of rotation and utilizing a large convex glenoid surface and concave humeral component with a neck-shaft angle of 155°. This design has been highly successful in cuff deficient shoulders, and indications continue to broaden. Many mid-term studies have improved upon the early encouraging results. Long-term studies are starting to emerge, demonstrating good survivorship, but progressive functional and radiographic deterioration continue to be concerning. Careful patient selection and attention to appropriate technique are required to reduce the current high rate of complications. New prosthesis designs are continuing to develop to address some of these limitations.

18.
J Bone Joint Surg Am ; 93(20): 1915-23, 2011 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-22012529

RESUMEN

BACKGROUND: Rheumatoid arthritis affecting the shoulder is typically associated with rotator cuff compromise and can also result in severe glenoid erosion. Since reverse shoulder arthroplasty is capable of addressing both rotator cuff disorders and glenoid bone deficiencies, our aim was to evaluate the outcome of reverse shoulder arthroplasty in patients with rheumatoid arthritis and either or both of these associated conditions. METHODS: We performed eighteen primary reverse total shoulder arthroplasties in sixteen patients with rheumatoid arthritis involving the shoulder as well as associated rotator cuff compromise and/or severe erosion of the glenoid bone between 2002 and 2007. Patients were assessed with use of the Constant score, patient satisfaction score, subjective shoulder value, range of shoulder motion, and imaging studies. RESULTS: The mean Constant score improved from 22.5 to 64.9 points at a mean of 3.8 years (range, 2.1 to 7.0 years) postoperatively. The patients were either very satisfied or satisfied with the outcome of the surgery in seventeen of the eighteen shoulders. The mean subjective shoulder value was 68.6% postoperatively. Active forward elevation improved from 77.5° to 138.6°, and external rotation with the arm in 90° of abduction improved from 16.9° to 46.1°. The mean Constant score improved from 28.0 points to 74.3 points in shoulders in which the teres minor muscle was normal before the surgery, and it improved from 20.8 to 54.6 points in shoulders with an atrophic teres minor muscle. Scapular notching was observed in ten of the eighteen shoulders. A fracture involving the acromion, acromial spine, coracoid, or greater tuberosity was observed either intraoperatively or postoperatively in four of the eighteen shoulders. One case of transient axillary nerve injury was noted. There were no cases of dislocation, infection, or component loosening. None of the patients required revision surgery for any reason. CONCLUSIONS: Comparatively good outcomes were observed in the short to intermediate term after reverse shoulder arthroplasty in patients with rheumatoid arthritis. However, surgeons should be aware of the risk of intraoperative and postoperative fractures in this patient group.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo/métodos , Prótesis Articulares , Rango del Movimiento Articular/fisiología , Articulación del Hombro/cirugía , Anciano , Artritis Reumatoide/diagnóstico , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Satisfacción del Paciente , Cuidados Posoperatorios/métodos , Radiografía , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Articulación del Hombro/diagnóstico por imagen , Dolor de Hombro/diagnóstico , Dolor de Hombro/etiología , Estadísticas no Paramétricas , Factores de Tiempo , Resultado del Tratamiento
19.
J Shoulder Elbow Surg ; 20(3): 385-94, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21055972

RESUMEN

PURPOSE: We assessed the clinical and radiologic results of a cemented all-polyethylene convex-back keeled glenoid component used with a third-generation prosthesis. METHODS: Between 1996 and 2003, in 4 European centers, 333 shoulder arthroplasties were performed for primary osteoarthritis by use of a cemented all-polyethylene convex-back keeled glenoid component. Kaplan-Meier survivorship analysis was performed, and clinical outcome was assessed with the Constant score, range of motion, and subjective evaluation. RESULTS: At a mean of 89.5 months' follow-up, the Constant score improved from 31.4 to 67.6 points (P < .0001). Active forward elevation improved from 94.9° to 146.6° (P < .0001) and external rotation from 9.0° to 35.3° (P < .0001). Of the patients, 93.5% were either satisfied or very satisfied. The rate of revision for glenoid loosening was 0.6%; however, the rate of radiologic glenoid loosening was 18.9%. Glenoid survival was 99.7% at 5 years and 98.3% at 10 years with endpoint defined as revision surgery for glenoid loosening and 99.7% at 5 years and 51.5% at 10 years with endpoint defined as radiologic loosening. CONCLUSIONS: We showed highly satisfactory clinical outcomes and extremely low rates of revision for glenoid loosening using a cemented convex-back keeled glenoid. There was a concerning rate of radiologic loosening, which only became apparent after 5 years, and this was associated with excessive glenoid reaming. Because radiologic changes are progressive and precede the need for revision, innovations in this field need to report radiologic and clinical results with follow-up of at least 5 to 10 years to prove any superiority.


Asunto(s)
Prótesis Articulares , Osteoartritis/cirugía , Articulación del Hombro/cirugía , Artroplastia de Reemplazo , Cementación , Estudios de Seguimiento , Humanos , Diseño de Prótesis , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...