Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38878017

RESUMEN

BACKGROUND: Comparative efficacy and safety data on radiofrequency ablation (RFA) versus pulsed field ablation (PFA) for common idiopathic left ventricular arrhythmia (LV-VAs) locations are lacking. OBJECTIVES: This study sough to compare RFA with PFA of common idiopathic LV-VAs locations. METHODS: Ten swine were randomized to PFA or RFA of LV interventricular septum, papillary muscle, LV summit via distal coronary sinus, and LV epicardium via subxiphoid approach. Ablations were delivered using an investigational dual-energy (RFA/PFA) contact force (CF) and local impedance-sensing catheter. After 1-week survival, animals were euthanized for lesion assessment. RESULTS: A total of 55 PFA (4 applications/site of 2.0 KV, target CF ≥10 g) and 36 RFA (CF ≥10 g, 25-50 W targeting ≥50 Ω local impedance drop, 60-second duration) were performed. LV interventricular septum: average PFA depth 7.8 mm vs RFA 7.9 mm (P = 0.78) and no adverse events. Papillary muscle: average PFA depth 8.1 mm vs RFA 4.5 mm (P < 0.01). Left ventricular summit: average PFA depth 5.6 mm vs RFA 2.7 mm (P < 0.01). Steam-pop and/or ventricular fibrillation in 4 of 12 RFA vs 0 of 12 PFA (P < 0.01), no ST-segment changes observed. Epicardium: average PFA depth 6.4 mm vs RFA 3.3 mm (P < 0.01). Transient ST-segment elevations/depressions occurred in 4 of 5 swine in the PFA arm vs 0 of 5 in the RFA arm (P < 0.01). Angiography acutely and at 7 days showed normal coronaries in all cases. CONCLUSIONS: In this swine study, compared with RFA, PFA of common idiopathic LV-VAs locations produced deeper lesions with fewer steam pops. However, PFA was associated with higher rates of transient ST-segment elevations and depressions with direct epicardium ablation.

2.
Artículo en Inglés | MEDLINE | ID: mdl-38752962

RESUMEN

BACKGROUND: Accurate measurements of intracardiac electrograms (EGMs) remain a clinical challenge because of the suboptimal attenuation of far-field potentials. Multielectrode mapping catheters provide an opportunity to construct multipolar instead of bipolar EGMs for rejecting common far-field potentials recorded from a multivectorial space. OBJECTIVES: The purpose of this study was to develop a multipolar EGM and compare its characteristics to those of bipolar EGMs METHODS: Using a 36-electrode array catheter (Optrell-36; Biosense Webster), a far-field component was mathematically constructed from clusters of electrodes surrounding each inspected electrode. This component was subtracted from the unipolar waveform to produce a local unipolar, referred to as a "multipolar EGM." The performance of multipolar EGMs was evaluated in 7 swine with healed anteroseptal infarction. RESULTS: Multipolar EGMs proved superior in attenuating far-field potentials in infarct border zones, increasing the near-field to far-field ratio from 0.92 ± 0.2 to 2.25 ± 0.3 (P < 0.001). Removal of far-field components reduced the voltage amplitude (P < 0.001) and enlarged the infarct surface area (P = 0.02), aligning more closely with histological findings. Of 379 EGMs with ≥20 ms activation time difference between bipolar and multipolar EGMs, 95.3% (361 of 379) were accurately annotated using multipolar EGMs, while annotation based on bipolar EGM was predominantly made on far-field components. CONCLUSIONS: Multielectrode array catheters provide a unique platform for constructing multipolar EGMs. This new EGM may be beneficial for "purifying" local potentials within a complex electrical field, resulting in more accurate voltage and activation maps.

3.
JACC Clin Electrophysiol ; 10(6): 1078-1086, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38703164

RESUMEN

BACKGROUND: In patients with persistent atrial fibrillation (PerAF), antiarrhythmic drugs (AADs) are considered a first-line rhythm-control strategy, whereas catheter ablation is a reasonable alternative. OBJECTIVES: This study sought to examine the prevalence, patient characteristics, and clinical outcomes of patients with PerAF who underwent catheter ablation as a first or second-line strategy. METHODS: This multicenter observational study included consecutive patients with PerAF who underwent first-time ablation between January 2020 and September 2021 in 9 medical centers in the United States. Patients were divided into those who underwent ablation as first-line therapy and those who had ablation as second-line therapy. Patient characteristics and clinical outcomes were compared between the groups. RESULTS: A total of 2,083 patients underwent first-time ablation for PerAF. Of these, 1,086 (52%) underwent ablation as a first-line rhythm-control treatment. Compared with patients treated with AADs as first-line therapy, these patients were predominantly male (72.6% vs 68.1%; P = 0.03), with a lower frequency of hypertension (64.0% vs 73.4%; P < 0.001) and heart failure (19.1% vs 30.5%; P < 0.001). During a mean follow-up of 325.9 ± 81.6 days, arrhythmia-free survival was similar between the groups (HR: 1.13; 95% CI: 0.92-1.41); however, patients in the second-line ablation strategy were more likely to continue receiving AAD therapy (41.5% vs 15.9%; P < 0.001). CONCLUSIONS: A first-line ablation strategy for PerAF is prevalent in the United States, particularly in men with fewer comorbidities. More data are needed to identify patients with PerAF who derive benefit from an early intervention strategy.


Asunto(s)
Antiarrítmicos , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/terapia , Masculino , Ablación por Catéter/estadística & datos numéricos , Femenino , Persona de Mediana Edad , Anciano , Antiarrítmicos/uso terapéutico , Resultado del Tratamiento , Estados Unidos/epidemiología
4.
Circ Arrhythm Electrophysiol ; 17(6): e012723, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38690671

RESUMEN

BACKGROUND: Conventional focal radiofrequency catheters may be modified to enable multiple energy modalities (radiofrequency or pulsed field [PF]) with the benefit of contact force (CF) feedback, providing greater flexibility in the treatment of arrhythmias. Information on the impact of CF on lesion formation in PF ablations remains limited. METHODS: An in vivo study was performed with 8 swine using an investigational dual-energy CF focal catheter with local impedance. Experiment I: To evaluate atrial lesion formation, contiguity, and width, a point-by-point approach was used to create an intercaval line. The distance between the points was prespecified at 4±1 mm. Half of the line was created with radiofrequency energy, whereas the other half utilized PF (single 2.0 kV application with a proprietary waveform). Experiment II: To evaluate single application lesion dimensions with a proprietary waveform, discrete ventricular lesions were performed with PFA (single 2.0 kV application) with targeted levels of CF: low, 5 to 15 g; medium, 20 to 30 g; and high, 35 to 45 g. Following 1 week of survival, animals underwent endocardial/epicardial remapping, and euthanasia to enable histopathologic examination. RESULTS: Experiment I: Both energy modalities resulted in a complete intercaval line of transmural ablation. PF resulted in significantly wider lines than radiofrequency: minimum width, 14.9±2.3 versus 5.0±1.6 mm; maximum width, 21.8±3.4 versus 7.3±2.1 mm, respectively; P<0.01 for each. Histology confirmed transmural lesions with both modalities. Experiment II: With PF, lesion depth, width, and volume were larger with higher degrees of CF (depth: r=0.82, P<0.001; width: r=0.26, P=0.052; and volume: r=0.55, P<0.001), with depth increasing at a faster rate than width. The mean depths were as follows: low (n=17), 4.3±1.0 mm; medium (n=26), 6.4±1.2 mm; and high (n=14), 9.1±1.4 mm. CONCLUSIONS: Using the same focal point CF-sensing catheter, a novel PF ablation waveform with a single application resulted in transmural atrial lesions that were significantly wider than radiofrequency. Lesion depth showed a significant positive correlation with CF with depths of 6.4 mm at moderate CF.


Asunto(s)
Catéteres Cardíacos , Ablación por Catéter , Diseño de Equipo , Animales , Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Porcinos , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Modelos Animales , Sus scrofa , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía
5.
J Cardiovasc Electrophysiol ; 35(6): 1203-1211, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38606650

RESUMEN

INTRODUCTION: Heart failure patients with a history of atrial fibrillation (AF) and ventricular tachycardia/ventricular fibrillation (VT/VF) are known to have worse outcomes. However, there are limited data on the temporal relationship between development of these arrhythmias and the risk of subsequent congestive heart failure (CHF) exacerbation and death. METHODS: The study cohort comprised 5511 patients implanted with an implantable cardioverter-defibrillator (ICD) in landmark clinical trials (MADIT-II, MADIT-RISK, MADIT-CRT, MADIT-RIT, and RAID) who were in sinus rhythm at enrollment. Multivariate cox analysis was performed to evaluate the time-dependent association between development of in-trial device detected AF and VT/VF with subsequent CHF exacerbation and death. RESULTS: Multivariate analysis showed that AF occurrence and VT/VF occurrence were both associated with a similar magnitude of risk for subsequent CHF exacerbation (HR = 1.73 and 1.87 respectively, p < .001 for both). In contrast, only in-trial VT/VF was associated with a significant > two-fold increase in the risk of subsequent mortality (HR = 2.13, p < .001) whereas AF occurrence was not associated with a significant mortality increase after adjustment for in-trial VT/VF (HR = 1.36, p = .096). CONCLUSION: Our findings from a large cohort of ICD recipients enrolled in landmark clinical trials show that device detected AF and VT/VF can be used to identify patients with increased risk for CHF exacerbation and mortality. These findings suggest a need for early intervention in CHF patients who develop device-detected atrial and ventricular tachyarrhythmias.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Masculino , Femenino , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/terapia , Taquicardia Ventricular/etiología , Anciano , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Fibrilación Atrial/mortalidad , Factores de Riesgo , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Fibrilación Ventricular/etiología , Factores de Tiempo , Medición de Riesgo , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Resultado del Tratamiento
6.
Pacing Clin Electrophysiol ; 47(5): 595-602, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38523591

RESUMEN

BACKGROUND: Data are lacking on patient-reported outcomes (PRO) following cryoballoon ablation (CBA) versus radiofrequency ablation (RFA). We sought to evaluate QoL and clinical outcomes of cryoballoon pulmonary vein isolation only (CRYO-PVI-ONLY) versus RFA with PVI and posterior wall isolation (RF-PVI+PWI) in a large prospective PRO registry. METHODS: Patients who underwent AF ablation (2013-2016) at our institution were enrolled in an automated, prospectively maintained PRO registry. CRYO-PVI-ONLY patients were matched (1:1) with RF-PVI+PWI patients based on age, gender, and type of AF (paroxysmal vs. persistent). QoL and clinical outcomes were assessed using PRO surveys at baseline and at 1-year. The atrial fibrillation symptom severity scale (AFSSS) was the measure for QoL. Additionally, we assessed patient-reported clinical improvement, arrhythmia recurrence, and AF burden (as indicated by AF frequency and duration scores). RESULTS: A total of 296 patients were included (148 in each group, 72% paroxysmal). By PRO, a significant improvement in QoL was observed in the overall study population and was comparable between CRYO-PVI-ONLY and RF-PVI+PWI (baseline median AFSSS of 11.5 and 11; reduced to 2 and 4 at 1 year, respectively; p = 0.44). Similarly, the proportion of patients who reported improvement in their overall QoL and AF related symptoms was high and similar between the study groups [92% (CRYO-PVI-ONLY) vs. 92.8% (RF-PVI+PWI); p = 0.88]. Arrhythmia recurrence was significantly more common in the CRYO-PVI-ONLY group (39.7%) compared to RF-PVI+PWI (27.7 %); p = 0.03. Comparable results were observed in paroxysmal and persistent AF. CONCLUSION: CRYO-PVI-ONLY and RF-PVI+PWI resulted in comparable improvements in patient reported outcomes including QoL and AF burden; with RF-PVI+PWI being more effective at reducing recurrences.


Asunto(s)
Fibrilación Atrial , Criocirugía , Medición de Resultados Informados por el Paciente , Venas Pulmonares , Humanos , Venas Pulmonares/cirugía , Masculino , Femenino , Criocirugía/métodos , Fibrilación Atrial/cirugía , Persona de Mediana Edad , Estudios Prospectivos , Atrios Cardíacos/cirugía , Ablación por Catéter/métodos , Sistema de Registros , Calidad de Vida , Anciano , Ablación por Radiofrecuencia/métodos
7.
J Cardiovasc Electrophysiol ; 35(4): 785-793, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38383981

RESUMEN

INTRODUCTION: Wearable cardioverter defibrillator (WCD) is utilized in patients with assumed but not yet confirmed risk for sudden cardiac death (SCD). Many of these patients also present with atrial fibrillation (AF). However, the rate of WCD-detected ventricular or atrial arrhythmia events in this specific high-risk cohort is not well understood. METHODS: In WEARIT-II, the cumulative probability of any sustained or nonsustained VT/VF (WCD-treated and nontreated), and atrial/supraventricular arrhythmias during WCD use was assessed using the Kaplan-Meier method by prior AF, with comparisons by the log-rank test. The incidence of ventricular and atrial arrhythmia events were expressed as events per 100 patient-years, and were analyzed by prior AF using negative binomial regression. RESULTS: WEARIT-II enrolled 2000 patients, 557 (28%) of whom had AF before enrollment. Cumulative probability of any sustained or nonsustained WCD-detected VT/VF during WCD use was significantly higher among patients with a history of AF than without AF (6% vs. 3%, p = .001). Similarly, the recurrent rate of any sustained or nonsustained VT/VF was significantly higher in patients with prior AF versus no prior AF (131.5 events per 100 patient-years vs. 22.7 events per 100 patient-years, p = .001). Patients with prior AF also had a significantly higher burden of any WCD-detected atrial arrhythmias/SVT/inappropriate arrhythmias therapy (183.2 events per 100 patient-years vs. 74.8 events per 100 patient-years, p < .001). CONCLUSION: Our results demonstrate that patients with a history of AF wearing the WCD for risk assessment have a higher incidence of ventricular arrhythmias that may facilitate the decision making for ICD implantation.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Cardioversión Eléctrica/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Medición de Riesgo , Sistema de Registros , Desfibriladores Implantables/efectos adversos
8.
J Am Heart Assoc ; 13(3): e028902, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38240206

RESUMEN

BACKGROUND: Sex-specific risk management may improve outcomes in congenital long QT syndrome (LQTS). We recently developed a prediction score for cardiac events (CEs) and life-threatening events (LTEs) in postadolescent women with LQTS. In the present study, we aimed to develop personalized risk estimates for the burden of CEs and LTEs in male adolescents with potassium channel-mediated LQTS. METHODS AND RESULTS: The prognostic model was derived from the LQTS Registry headquartered in Rochester, NY, comprising 611 LQT1 or LQT2 male adolescents from age 10 through 20 years, using the following variables: genotype/mutation location, QTc-specific thresholds, history of syncope, and ß-blocker therapy. Anderson-Gill modeling was performed for the end point of CE burden (total number of syncope, aborted cardiac arrest, and appropriate defibrillator shocks). The applicability of the CE prediction model was tested for the end point of the first LTE (excluding syncope and adding sudden cardiac death) using Cox modeling. A total of 270 CEs occurred during follow-up. The genotype-phenotype risk prediction model identified low-, intermediate-, and high-risk groups, comprising 74%, 14%, and 12% of the study population, respectively. Compared with the low-risk group, high-risk male subjects experienced a pronounced 5.2-fold increased risk of recurrent CEs (P<0.001), whereas intermediate-risk patients had a 2.1-fold (P=0.004) increased risk . At age 20 years, the low-, intermediate-, and high-risk adolescent male patients had on average 0.3, 0.6, and 1.4 CEs per person, respectively. Corresponding 10-year adjusted probabilities for a first LTE were 2%, 6%, and 8%. CONCLUSIONS: Personalized genotype-phenotype risk estimates can be used to guide sex-specific management in male adolescents with potassium channel-mediated LQTS.


Asunto(s)
Síndrome de QT Prolongado , Canales de Potasio , Humanos , Masculino , Adolescente , Femenino , Adulto Joven , Adulto , Niño , Canales de Potasio/genética , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/congénito , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Síncope/genética , Síncope/epidemiología , Genotipo , Factores de Riesgo , Medición de Riesgo , Electrocardiografía
9.
JACC Clin Electrophysiol ; 10(1): 16-26, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38032575

RESUMEN

BACKGROUND: There are conflicting data on the effect of cardiac resynchronization therapy with a defibrillator (CRT-D) on the risk of life-threatening ventricular tachyarrhythmia in heart failure patients. OBJECTIVES: The authors aimed to assess whether QRS morphology is associated with risk of ventricular arrhythmias in CRT recipients. METHODS: The study population comprised 2,862 patients implanted with implantable cardioverter defibrillator (ICD)/CRT-D for primary prevention who were enrolled in 5 landmark primary prevention ICD trials (MADIT-II [Multicenter Automated Defibrillator Implantation Trial], MADIT-CRT [Multicenter Automated Defibrillator Implantation Trial-Cardiac Resynchronization Therapy], MADIT-RIT [Multicenter Automated Defibrillator Implantation Trial-Reduction in Inappropriate Therapy], MADIT-RISK [Multicenter Automated Defibrillator Implantation Trial-RISK], and RAID [Ranolazine in High-Risk Patients With Implanted Cardioverter Defibrillators]). Patients with QRS duration ≥130 ms were divided into 2 groups: those implanted with an ICD only vs CRT-D. The primary endpoint was fast ventricular tachycardia (VT)/ventricular fibrillation (VF) (defined as VT ≥200 beats/min or VF), accounting for the competing risk of death. Secondary endpoints included appropriate shocks, any sustained VT or VF, and the burden of fast VT/VF, assessed in a recurrent event analysis. RESULTS: Among patients with left bundle branch block (n = 1,792), those with CRT-D (n = 1,112) experienced a significant 44% (P < 0.001) reduction in the risk of fast VT/VF compared with ICD-only patients (n = 680), a significantly lower burden of fast VT/VF (HR: 0.55; P = 0.001), with a reduced burden of appropriate shocks (HR: 0.44; P < 0.001). In contrast, among patients with non-left bundle branch block (NLBBB) (N = 1,070), CRT-D was not associated with reduction in fast VT/VF (HR: 1.33; P = 0.195). Furthermore, NLBBB patients with CRT-D experienced a statistically significant increase in the burden of fast VT/VF events compared with ICD-only patients (HR: 1.90; P = 0.013). CONCLUSIONS: Our data suggest a potential proarrhythmic effect of CRT among patients with NLBBB. These data should be considered in patient selection for treatment with CRT.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Bloqueo de Rama/terapia , Bloqueo de Rama/etiología , Terapia de Resincronización Cardíaca/efectos adversos , Desfibriladores Implantables/efectos adversos , Resultado del Tratamiento , Fibrilación Ventricular/epidemiología , Fibrilación Ventricular/terapia
10.
JACC Clin Electrophysiol ; 10(2): 222-234, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37978965

RESUMEN

BACKGROUND: The efficacy of pulsed field ablation (PFA) for redo procedures is unknown. OBJECTIVES: In this study, the authors aimed to evaluate the effectiveness of PFA when performing PFA over chronic RFA (redo environment). METHODS: This was a 3-step in vivo study. In step 1 (creation of redo environment), 6 swine underwent radiofrequency ablation (RFA) with a local impedance measuring catheter and a contact force-enabled catheter in 3 different sites: the right atrium (RA) (intercaval line with intentional gaps), the left atrium (LA) (pulmonary vein isolation [PVI] with intentional gaps and superficial posterior wall ablations), and the left ventricle (LV) (short RFA applications [chronic RFA]). In step 2 (re-ablation), following a survival period of ≈5 weeks, animals were retreated as follows: in the RA, a focal PFA catheter over the prior intercaval line; in the LA, PVI using a pentaspline PFA catheter; and in the LV, animals were randomized to focal PFA or RFA. In each arm, 2 types of lesions were performed: acute or acute over chronic. In step 3 (remapping and euthanization), following an additional 3 to 5 days, all animals were remapped and sacrificed. RESULTS: In the RA, re-ablation with PFA resulted in a complete intercaval block in all animals, expanding and homogenizing the disparate chronic RFA lesions from a width of 4 to 7 mm (chronic RFA) to a width of 16 to 28 mm (PFA over chronic RFA). In the LA, re-ablation with PFA resulted in complete PVI and transmural ablation of the PW. In the LV, the mean depth for acute RFA (post 2-5 days survival) was 7.6 ± 1.3 mm vs 3.9 ± 1.6 mm in the acute over chronic RFA lesions (P < 0.01). In contrast, the mean depth for acute PFA was 7.0 ± 1.6 mm, similar to when ablating with PFA over RFA (7.1 ± 1.3 mm; P = 0.94). CONCLUSIONS: PFA is highly efficient for ablation following prior RFA, which may be beneficial in patients presenting for redo procedures. In the ventricle, PFA resulted in lesions that are deeper than RFA when ablating over chronic superficial RFA lesions.


Asunto(s)
Ablación por Catéter , Ablación por Radiofrecuencia , Humanos , Animales , Porcinos , Atrios Cardíacos/cirugía , Ventrículos Cardíacos/cirugía , Catéteres , Impedancia Eléctrica
12.
Europace ; 25(12)2023 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-38000893

RESUMEN

AIMS: Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS: The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION: Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Niño , Adolescente , Desfibriladores Implantables/efectos adversos , Estudios Prospectivos , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Estudios Retrospectivos , Resultado del Tratamiento
13.
Artículo en Inglés | MEDLINE | ID: mdl-37848806

RESUMEN

BACKGROUND: Atrial fibrillation (AF) risk increases with age. We aim to assess the efficacy and safety of catheter ablation in the older population. METHODS: All patients undergoing AF ablation (2013-2021) at our institution were enrolled in a prospectively maintained registry. The primary endpoint was AF recurrence. Patients were divided into 3 groups: non-elderly (< 65 years), elderly (65-75 years), and very elderly (> 75 years). Patient surveys at baseline and during follow-up were used to calculate quality of life (QoL) metrics: the AF severity score as well as the AF burden. RESULTS: A total of 7020 patients were included (42% non-elderly, 42% elderly, and 16% very elderly). Periprocedural major complications were low (< 1.5%) and similar in all groups besides pericardial effusion which was more frequent with older age and similar between the elderly and very elderly. At 3 years, AF recurrence for persistent AF (PersAF) was highest in the very elderly group (48%), followed by the elderly group (42%), and was the lowest in the non-elderly group (36%). In paroxysmal AF (PAF), there was no difference in AF recurrence between the elderly and non-elderly, while the very elderly remained associated with a significantly increased risk. Multivariable Cox analysis confirmed these findings (PersAF; elderly: HR = 1.23, P = 0.003; very elderly: HR = 1.44, P < 0.001) (PAF; elderly: HR = 1.04, P = 0.62; very elderly: HR = 1.30, P = 0.01). Catheter ablation resulted in a significant improvement in quality of life, irrespective of age group. CONCLUSION: Catheter ablation in elderly and very elderly patients is safe, efficacious, and associated with QoL benefits. Overall, major complications were minimal and did not differ significantly between age groups, with the exception of pericardial effusions which were higher in the elderly and very elderly compared to non-elderly adults. Very elderly patients had a higher rate of AF recurrence when compared with elderly or non-elderly patients. Nevertheless, ablation resulted in a remarkable improvement in QoL and a reduction of AF burden and AF symptoms with a similar magnitude, irrespective of age.

15.
Front Cardiovasc Med ; 10: 1237118, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37680559

RESUMEN

Introduction: The implantable cardioverter defibrillator (ICD) is effective for the prevention of sudden cardiac death (SCD) in patients with heart failure and a reduced ejection fraction (HFrEF). The benefit of the ICD in patients with advanced CKD, remains elusive. Moreover, the benefit of the ICD in patients with advanced chronic kidney disease (CKD) and HFrEF who are cardiac resynchronization therapy (CRT) recipients may be attenuated. Hypothesis: We hypothesized that patients with CKD who are CRT recipients may derive less benefit from the ICD due to the competing risk of dying prior to experiencing an arrhythmia. Methods: The study population included 1,015 patients receiving CRT with defibrillator (CRT-D) device for primary prevention of SCD who were enrolled in either (Multicenter Automated Defibrillator Implantation Trial) MADIT-CRT trial or the Ranolazine in High-Risk Patients with Implanted Cardioverter Defibrillator (RAID) trial. The cohort was divided into two groups based on the stage of CKD: those with Stage 1 to 3a KD, labeled as (S1-S3a)KD. The second group included patients with Stage 3b to stage 5 kidney disease, labeled as (S3b-S5)KD. The primary endpoint was any ventricular tachycardia (VT) or ventricular fibrillation (VF) (Any VT/VF). Results: The cumulative incidence of Any VT/VF was 23.5% in patients with (S1-S3a)KD and 12.6% in those with (S3b-S5)KD (p < 0.001) The incidence of Death without Any VT/VF was 6.6% in patients with (S1-S3a)KD and 21.6% in patients with (S3b-S5)KD (p < 0.001). A Fine and Gray multivariate competing risk regression model showed that Patients with (S3b-S5)KD had a 43% less risk of experiencing Any VT/VF when compared to those with (S1-S3a)KD (HR = 0.56, 95% CI [0.33-0.94] p = 0.03. After two years of follow up, there was almost a 5-fold increased risk of Death without Any VT/VF among patients with (S3b-S5)KD when compared to those with (S1-S3a)KD [HR = 4.63, 95% CI (2.46-8.72), p for interaction with time = 0.012]. Conclusion: Due to their lower incidence of arrhythmias and higher risk of dying prior to experiencing an arrhythmia, the benefit of the ICD may be attenuated in CRT recipients with advanced CKD. Future prospective trials should evaluate whether CRT without a defibrillator may be more appropriate for these patients.

16.
JACC Clin Electrophysiol ; 9(10): 2122-2131, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37656097

RESUMEN

BACKGROUND: Both selective and nonselective beta-blockers are used to treat patients with heart failure (HF). However, the data on the association of beta-blocker type with risk of atrial arrhythmia and ventricular arrhythmia (VA) in HF patients with a primary prevention implantable cardioverter-defibrillator (ICD) are limited. OBJECTIVES: This study sought to evaluate the effect of metoprolol vs carvedilol on the risk of atrial tachyarrhythmia (ATA) and VA in HF patients with an ICD. METHODS: This study pooled primary prevention ICD recipients from 5 landmark ICD trials (MADIT-II, MADIT-CRT, MADIT-RIT, MADIT-RISK, and RAID). Fine and Gray multivariate regression models, stratified by study, were used to evaluate the risk of ATA, inappropriate ICD shocks, and fast VA (defined as ventricular tachycardia ≥200 beats/min or ventricular fibrillation) by beta-blocker type. RESULTS: Among 4,194 patients, 2,920 (70%) were prescribed carvedilol and 1,274 (30%) metoprolol. The cumulative incidence of ATA at 3.5 years was 11% in patients treated with carvedilol vs 15% in patients taking metoprolol (P = 0.003). Multivariate analysis showed that carvedilol treatment was associated with a 35% reduction in the risk of ATA (HR: 0.65; 95% CI: 0.53-0.81; P < 0.001) when compared to metoprolol, and with a corresponding 35% reduction in the risk of inappropriate ICD shocks (HR: 0.65; 95% CI: 0.47-0.89; P = 0.008). Carvedilol vs metoprolol was also associated with a 16% reduction in the risk of fast VA. However, these findings did not reach statistical significance (HR: 0.84; 95% CI: 0.70-1.02; P = 0.085). CONCLUSIONS: These findings suggests that HF patients with ICDs on carvedilol treatment experience a significantly lower risk of ATA and inappropriate ICD shocks when compared to treatment with metoprolol.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Metoprolol/uso terapéutico , Carvedilol/uso terapéutico , Desfibriladores Implantables/efectos adversos , Fibrilación Atrial/inducido químicamente , Antagonistas Adrenérgicos beta/efectos adversos , Insuficiencia Cardíaca/complicaciones
17.
Ann Noninvasive Electrocardiol ; 28(5): e13080, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37571804

RESUMEN

BACKGROUND: Congenital Long QT Syndrome (LQTS) is a hereditary arrhythmic disorder. We aimed to assess the performance of current genetic variant annotation scores among LQTS patients and their predictive impact. METHODS: We evaluated 2025 patients with unique mutations for LQT1-LQT3. A patient-specific score was calculated for each of four established genetic variant annotation algorithms: CADD, SIFT, REVEL, and PolyPhen-2. The scores were tested for the identification of LQTS and their predictive performance for cardiac events (CE) and life-threatening events (LTE) and then compared with the predictive performance of LQTS categorization based on mutation location/function. Score performance was tested using Harrell's C-index. RESULTS: A total of 917 subjects were classified as LQT1, 838 as LQT2, and 270 as LQT3. The identification of a pathogenic variant occurred in 99% with CADD, 92% with SIFT, 100% with REVEL, and 86% with PolyPhen-2. However, none of the genetic scores correlated with the risk of CE (Harrell's C-index: CADD = 0.50, SIFT = 0.51, REVEL = 0.50, and PolyPhen-2 = 0.52) or LTE (Harrell's C-index: CADD = 0.50, SIFT = 0.53, REVEL = 0.54, and PolyPhen-2 = 0.52). In contrast, high-risk mutation categorization based on location/function was a powerful independent predictor of CE (HR = 1.88; p < .001) and LTE (HR = 1.89, p < .001). CONCLUSION: In congenital LQTS patients, well-established algorithms (CADD, SIFT, REVEL, and PolyPhen-2) were able to identify the majority of the causal variants as pathogenic. However, the scores did not predict clinical outcomes. These results indicate that mutation location/functional assays are essential for accurate interpretation of the risk associated with LQTS mutations.


Asunto(s)
Electrocardiografía , Síndrome de QT Prolongado , Humanos , Genotipo , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/complicaciones
18.
JAMA Cardiol ; 8(8): 775-783, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37436769

RESUMEN

Importance: Syncope is the most powerful predictor for subsequent life-threatening events (LTEs) in patients with congenital long QT syndrome (LQTS). Whether distinct syncope triggers are associated with differential subsequent risk of LTEs is unknown. Objective: To evaluate the association between adrenergic (AD)- and nonadrenergic (non-AD)-triggered syncopal events and the risk of subsequent LTEs in patients with LQT types 1 to 3 (LQT1-3). Design, Setting, and Participants: This retrospective cohort study included data from 5 international LQTS registries (Rochester, New York; the Mayo Clinic, Rochester, Minnesota; Israel, the Netherlands, and Japan). The study population comprised 2938 patients with genetically confirmed LQT1, LQT2, or LQT3 stemming from a single LQTS-causative variant. Patients were enrolled from July 1979 to July 2021. Exposures: Syncope by AD and non-AD triggers. Main Outcomes and Measures: The primary end point was the first occurrence of an LTE. Multivariate Cox regression was used to determine the association of AD- or non-AD-triggered syncope on the risk of subsequent LTE by genotype. Separate analysis was performed in patients with ß-blockers. Results: A total of 2938 patients were included (mean [SD] age at enrollment, 29 [7] years; 1645 [56%] female). In 1331 patients with LQT1, a first syncope occurred in 365 (27%) and was induced mostly with AD triggers (243 [67%]). Syncope preceded 43 subsequent LTEs (68%). Syncopal episodes associated with AD triggers were associated with the highest risk of subsequent LTE (hazard ratio [HR], 7.61; 95% CI, 4.18-14.20; P < .001), whereas the risk associated with syncopal events due to non-AD triggers was statistically nonsignificant (HR, 1.50; 95% CI, 0.21-4.77; P = .97). In 1106 patients with LQT2, a first syncope occurred in 283 (26%) and was associated with AD and non-AD triggers in 106 (37%) and 177 (63%), respectively. Syncope preceded 55 LTEs (56%). Both AD- and non-AD-triggered syncope were associated with a greater than 3-fold increased risk of subsequent LTE (HR, 3.07; 95% CI, 1.66-5.67; P ≤ .001 and HR, 3.45, 95% CI, 1.96-6.06; P ≤ .001, respectively). In contrast, in 501 patients with LQT3, LTE was preceded by a syncopal episode in 7 (12%). In patients with LQT1 and LQT2, treatment with ß-blockers following a syncopal event was associated with a significant reduction in the risk of subsequent LTEs. The rate of breakthrough events during treatment with ß-blockers was significantly higher among those treated with selective agents vs nonselective agents. Conclusion and Relevance: In this study, trigger-specific syncope in LQTS patients was associated with differential risk of subsequent LTE and response to ß-blocker therapy.


Asunto(s)
Síndrome de QT Prolongado , Humanos , Femenino , Niño , Masculino , Estudios Retrospectivos , Factores de Riesgo , Síndrome de QT Prolongado/complicaciones , Síndrome de QT Prolongado/epidemiología , Síndrome de QT Prolongado/genética , Síncope/epidemiología , Síncope/etiología , Antagonistas Adrenérgicos beta/uso terapéutico
19.
Circulation ; 148(3): 241-252, 2023 07 18.
Artículo en Inglés | MEDLINE | ID: mdl-37459413

RESUMEN

BACKGROUND: Black Americans have a higher risk of nonischemic cardiomyopathy (NICM) than White Americans. We aimed to evaluate differences in the risk of tachyarrhythmias among patients with an implantable cardioverter-defibrillator (ICD). METHODS: The study population comprised 3895 ICD recipients in the United States enrolled in primary prevention ICD trials. Outcome measures included ventricular tachyarrhythmia (VTA), atrial tachyarrhythmia (ATA), ICD therapies, VTA burden (using Andersen-Gill recurrent event analysis), death, and the predicted benefit of the ICD. All events were adjudicated blindly. Outcomes were compared between self-reported Black patients versus White patients with cardiomyopathy (ischemic and NICM). RESULTS: Black patients were more likely to be female (35% versus 22%) and younger (57±12 versus 62±12 years) with a higher frequency of comorbidities. In NICM, Black patients had a higher rate of first VTA, fast VTA, ATA, and appropriate and inappropriate ICD therapy (VTA ≥170 bpm, 32% versus 20%; VTA ≥200 bpm, 22% versus 14%; ATA, 25% versus 12%; appropriate therapy, 30% versus 20%; and inappropriate therapy, 25% versus 11%; P<0.001 for all). Multivariable analysis showed that Black patients with NICM experienced a higher risk of all types of arrhythmia or ICD therapy (VTA ≥170 bpm, hazard ratio [HR] 1.71; VTA ≥200 bpm, HR 1.58; ATA, HR 1.87; appropriate therapy, HR 1.62; inappropriate therapy, HR 1.86; P≤0.01 for all), higher burden of tachyarrhythmias or therapies (VTA, HR 1.84; appropriate therapy, HR 1.84; P<0.001 for both), and a higher risk of death (HR 1.92; P=0.014). In contrast, in ischemic cardiomyopathy, the risk of all types of tachyarrhythmia, ICD therapy, or death was similar between Black patients and White patients. Both Black patients and White patients derived a significant and similar benefit from ICD implantation. CONCLUSIONS: Among patients with NICM with an ICD for primary prevention, Black patients compared with White patients had a high risk and burden of VTA, ATA, and ICD therapies with a lower survival rate. Nevertheless, the overall benefit of the ICD was maintained and was similar to that of White patients.


Asunto(s)
Cardiomiopatías , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Femenino , Estados Unidos/epidemiología , Masculino , Blanco , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Factores de Riesgo , Arritmias Cardíacas , Taquicardia Ventricular/terapia , Taquicardia Ventricular/epidemiología , Prevención Primaria
20.
J Cardiovasc Electrophysiol ; 34(8): 1595-1604, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37453072

RESUMEN

INTRODUCTION: Use of sodium glucose cotransporter 2 inhibitors (SGLT2i) was associated with a reduction in atrial fibrillation hospitalizations. Therefore, we aim to evaluate the effects of SGLT2i on atrial tachy-arrhythmias (ATA) in patients with cardiac implantable electronic devices (CIEDs). METHODS: All 13 888 consecutive patients implanted with a CIED in two tertiary medical centers were enrolled. Treatment with SGLT2i was assessed as a time dependent variable. The primary endpoint was the total number of ATA. Secondary endpoints included total number of ventricular tachy-arrhythmias (VTA), ATA and VTA, and death. All events were independently adjudicated blinded to the treatment. Multivariable propensity score modeling was performed. RESULTS: During a total follow-up of 24 442 patient years there were 62 725 ATA and 10 324 VTA events. Use of SGLT2i (N = 696) was independently associated with a significant 22% reduction in the risk of ATA (hazard ratio [HR] = 0.78 [95% confidence interval {CI} = 0.70-0.87]; p < .001); 22% reduction in the risk of ATA/VTA (HR = 0.78 [95% CI = 0.71-0.85]; p < .001); and with a 35% reduction in the risk of all-cause mortality (HR = 0.65 [95% CI = 0.45-0.92]; p = .015), but was not significantly associated with VTA risk (HR = 0.92 [95% CI = 0.80-1.06]; p = .26). SGLT2i were associated with a lower ATA burden in heart failure (HF) patients but not among diabetes patients (HF: HR = 0.68, 95% CI = 0.58-0.80, p < .001 vs. Diabetes: HR = 0.95, 95% CI = 0.86-1.05, p = .29; p < .001 for interaction between SGLT2i indication and ATA burden). CONCLUSION: Our real world findings suggest that in CIED HF patients, those with SGLT2i had a pronounced reduction in ATA burden and all-cause mortality when compared with those not on SGLT2i.


Asunto(s)
Fibrilación Atrial , Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos , Fibrilación Atrial/complicaciones , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Glucosa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...