Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Intervalo de año de publicación
1.
Poult Sci ; 101(3): 101627, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34995878

RESUMEN

The current trend in monitoring meat quality is to move the quality measurements from the laboratory to the processing line. To provide better meat quality control in the commercial poultry processing plants, we evaluated the quality of broiler breast meat samples, observing different colors, and assessed their freshness using a Torrymeter. Different colors were classified based on the mean ± standard deviation of lightness (L*) values in 1,499 broiler breast fillets: Dark (L* < 56), normal (56 ≤ L* ≤ 62), and pale (L* > 62). To characterize the differences between the pale and normal color groups, we evaluated additional fillets for meat quality traits. Changes in meat quality during storage were also evaluated. The L* and Torrymeter values (freshness values) allowed us to distinguish between the pale and normal meat samples. Normal and pale fillets showed a significant difference in pH, Torrymeter values, and water-holding capacity (P < 0.001). The L* values were significantly correlated with cook and drip loss (P < 0.01) and were higher (paler, +1.2 L* unit) at 72-h postmortem than at 4-h postmortem. Torrymeter values were correlated with cook loss (P < 0.05) and pH (P < 0.001), and significantly decreased with the increase in storage period (P < 0.001). These results suggest the applicability of the Torrymeter, a fast and non-destructive device, in distinguishing stale and fresh breast fillets. With its portability and simplicity, the Torrymeter is expected to be a valuable tool to estimate meat freshness. Especially, the use of Torrymeter for evaluating pale breast fillets may allow easy identification and separation of fillets according to their pale, soft, and exudative properties in commercial poultry processing lines.


Asunto(s)
Pollos , Aves de Corral , Animales , Color , Culinaria , Carne/análisis
2.
Artículo en Inglés | WPRIM (Pacífico Occidental) | ID: wpr-100623

RESUMEN

OBJECTIVES: Children with attention-deficit hyperactivity disorder (ADHD) may have deficits in time perception, as assessed by the time estimation task and the time reproduction task, however its age-related trajectory is not yet determined. Therefore we examined the correlation between accuracy of time perception tasks and age, and the association between accuracy of estimation tasks and reproduction tasks. METHODS: Sixty-three patients with ADHD, aged 8 to 18 years tested the tasks for five time durations (2, 4, 12, 45, and 60 seconds). Accuracy of tasks was assumed differences (absolute values) between raw results of tasks and original time durations. Spearman's correlation analysis was performed to determine correlation between accuracy of time perception tasks and age. Multivariate regression was used to determine the association of accuracy of estimation tasks with accuracy of reproduction tasks. RESULTS: Age showed correlation with accuracy of estimation tasks, but not with that of reproduction tasks. We observed that the higher the accuracy in 12, 45, and 60 seconds duration time reproduction, the higher the accuracy in longer seconds duration time estimation. CONCLUSION: Age was correlated with time estimation accuracy whereas there was no impact on time reproduction accuracy. Association of each of the two time perception tasks, particularly in longer time duration, suggested specific impairments in time perception.


Asunto(s)
Adolescente , Niño , Humanos , Factores de Edad , Reproducción , Percepción del Tiempo
3.
Yonsei Med J ; 49(3): 507-8, 2008 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-18581604

RESUMEN

Pulmonary sequestration is an unusual malformation consisting of isolated nonfunctioning lung segments lacking communication with functional tracheobronchial trees. Systemic blood supply is commonly from the thoracic aorta, but arteries occasionally arise from other sites. We report a rare form of pulmonary sequestration with arterial supply from the right coronary artery.


Asunto(s)
Secuestro Broncopulmonar/patología , Anomalías de los Vasos Coronarios/patología , Anciano , Secuestro Broncopulmonar/diagnóstico por imagen , Angiografía Coronaria , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos
4.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-106856

RESUMEN

PURPOSE: In order to obtain better quantitation of kidney uptake, this study is to evaluate a conjugate view method (CVM) using a geometric mean attenuation correction for kidney uptake and to compare it to Gate's method. MATERIALS AND METHODS: We used a Monte Carlo code, SIMIND and a Zubal phantom, to simulate kidney uptake. SIMIND was both simulated with or without scatter for the Zubal phantom. Also, a real phantom test was carried out using a dual-head gamma camera. The activity of 0.5 mCi was infused into two small cylinder phantoms of 5 cm diameter, and then, they were inserted into a cylinder phantom of 20 cm diameter. The results by the CVM method were compared with ideal data without both of attenuation and scatter and with Gate's method. The CVM was performed with or without scatter correction. The Gate's method was performed without scatter correction and it was evaluated with regards to 0.12 cm (-1) and 0.15 cm (-1) attenuation coefficients. Data were analyzed with comparisons of mean counts in the regions of interest (ROI), profiles drawn over kidney images and linear regression. Correlation coefficients were calculated with ideal data, as well. RESULTS: In the case of the computer simulation, mean counts measured from ideal data, the CVM and the Gate's method were (right: 998 +/- 209, left: 896 +/- 249), (right: 911 +/- 207, left: 815 +/- 265), and (right: 1065 +/- 267, left: 1546 +/- 267), respectively. The ideal data showed good correlation with the CVM and the correlation coefficients of the CVM, Gate's method were (right: 0.91, left: 0.93) and (right: 0.85, left: 0.90), respectively. CONCLUSION: The conjugate view method using geometric mean attenuation correction resulted in better accuracy than the Gate's method. In conclusion, the conjugate view method independent of renal depths may provide more accurate kidney uptake.


Asunto(s)
Simulación por Computador , Cámaras gamma , Riñón , Modelos Lineales
5.
Artículo en Coreano | WPRIM (Pacífico Occidental) | ID: wpr-214145

RESUMEN

Experiments and simulation were done to study the impact of contrast agent when CT scan was used to attenuation correction for PET images in PET/CT system. Whole body phantom was imaged with various concentration of iodine-based contrast agent using CT. Mathematical emission and transmission density map with liver were made to simulate for whole body FDG imaging. A variety of factors were estimated, including non-uniform enhancement of contrast agent, concentration and distribution size of contrast agent, noise level, image resolution, reconstruction algorithm, hypo-attenuation of contrast agent, and different time phases for contrast agent. Experimental studies showed that Hounsfield unit depends on the concentration of contrast agent and tube voltage. From the simulation data, contrast agents introduced artifacts and degraded image quality on the attenuation-corrected PET images. The severity of these effects depends on a variety of factors, including the concentration and distribution size of contrast agent, the noise levels, and the image resolution. These results indicated that the impact of contrast agents should be considered with a full understanding of their potential problems in clinical PET/CT images.


Asunto(s)
Artefactos , Medios de Contraste , Hígado , Ruido , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...