Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Vet Anaesth Analg ; 42(2): 205-14, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24890907

RESUMEN

OBJECTIVE: To evaluate a thermal nociceptive threshold (TNT) testing device in the donkey, and the influence of potential confounding factors on TNTs. ANIMALS: Two groups (Group 1 and Group 2) of eight castrated male donkeys aged 4-9 years, weighing 105-170 kg. METHODS: TNTs were measured by heating a thermal probe on skin until an end-point behaviour (threshold temperature) or a cut-out temperature (51 °C) was reached. The withers and the dorsal aspect of the distal limb were used as sites for TNT testing. The effects on TNT of different confounding factors: the limb tested; rate of heating; and ambient temperature were evaluated. Data were analyzed using general linear models, and Mann-Whitney tests, p < 0.05 was considered significant. RESULTS: End-point behaviours (skin twitch or donkey looking at test device) when the thermal probe heated the withers were observed in approximately half of tests. TNT was (mean ± SD) 46.8 ± 2.85 °C. Subsequently the limb was evaluated as the test site in Group 1 followed by Group 2 donkeys; end-point behaviour being a foot-lift. In Group 1, 72% of tests ended in an end-point behaviour but the response rate was lower in Group 2 (20%), although TNTs were similar [(47.6 ± 3.3) and (47.3 ± 3.0) °C respectively] for responding animals. Rate of heating, ambient temperature and laterality (right or left) did not affect thresholds, but mean TNT was significantly higher in the forelimb (48.5 ± 2.8 °C) than the hind limb (47.4 ± 2.8 °C) (p = 0.012). CONCLUSIONS: When a thermal probe cut-out temperature of 51 °C was used in TNT testing in the donkey a high proportion of tests did not produce an identifiable end point behaviour. Higher cut-out temperatures damaged the skin. Under these conditions, thermal nociceptive threshold testing appears not be an appropriate analgesiometry technique in the donkey. CLINICAL RELEVANCE: TNT testing under these conditions is not suitable form of analgesiometry for donkeys.


Asunto(s)
Equidae/fisiología , Umbral del Dolor/fisiología , Animales , Calor , Masculino , Nocicepción/fisiología , Dimensión del Dolor/veterinaria , Fenómenos Fisiológicos de la Piel
2.
Vet Anaesth Analg ; 41(4): 421-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24576142

RESUMEN

OBJECTIVE: To evaluate a mechanical nociceptive threshold (MNT) testing device in the donkey, and to investigate the influence of potential confounders on MNTs generated. STUDY DESIGN: Prospective, randomised. ANIMALS: Sixteen castrated male donkeys aged 4-9 years, weighing 105-170 kg. METHODS: Mechanical nociceptive thresholds were measured using an actuator with three pins placed on the dorsal aspect of the distal limb, connected to a force meter. The pins (surface area 15 mm(2) ) were extruded onto the limb by pressurising an air-filled syringe, until the MNT force (when foot-lift was observed) or 25 N (cut-off force) was reached. Effect on MNT of presence of a companion donkey, the limb tested, rate of application of force, testing location, level of distraction, ambient temperature and hair cover at the test site was evaluated. Long and short-term repeatability of MNT was assessed. Data were analysed using general linear models and Mann-Whitney U tests, p < 0.05 was considered significant. RESULTS: Increasing the rate of force application significantly increased the mean ± SD MNT from 9.2 ± 2.0 N when applied at 0.4 N sec(-1) to 10.6 ± 2.1 N when applied at 1.2 N sec(-1) (p = 0.001). No other factors significantly influenced MNT. Mean MNT remained stable over a 3 week period, however MNTs were significantly (p = 0.006) higher (12.8 ± 3.0 N cf 10.3 ± 1.9 N) after a 12 month interval. CONCLUSIONS AND CLINICAL RELEVANCE: When designing studies measuring MNT in donkeys, rate of application of force must be standardised. Donkeys' MNTs have good short-term stability suggesting this technique is appropriate for short-term analgesiometry studies; however variability of MNTs over the long-term is greater.


Asunto(s)
Equidae , Dimensión del Dolor/veterinaria , Umbral del Dolor , Presión/efectos adversos , Animales , Masculino , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...