Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Am Coll Cardiol ; 43(2): 302-9, 2004 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-14736453

RESUMEN

OBJECTIVES: The purpose of this study was to investigate the incidence, morphology, and clinical course of thrombus formation after catheter closure of intra-atrial shunts. BACKGROUND: Post-procedure detailed information about thrombotic material on different devices for transcatheter closure is missing. METHOD: A total of 1,000 consecutive patients were investigated after patent foramen ovale (PFO) (n = 593) or atrial septal defect (ASD) (n = 407) closure. Transesophageal echocardiography (TEE) was scheduled after four weeks and six months. Additional TEEs were performed as clinically indicated. RESULTS: Thrombus formation in the left atrium (n = 11), right atrium (n = 6), or both (n = 3) was found in 5 of the 407 (1.2%) ASD patients and in 15 of the 593 (2.5%) PFO patients (p = NS). The thrombus was diagnosed in 14 of 20 patients after four weeks and in 6 of 20 patients later on. The incidence was: 7.1% in the CardioSEAL device (NMT Medical, Boston, Massachusetts); 5.7% in the StarFLEX device (NMT Medical); 6.6% in the PFO-Star device (Applied Biometrics Inc., Burnsville, Minnesota); 3.6% in the ASDOS device (Dr. Ing, Osypka Corp., Grenzach-Wyhlen, Germany); 0.8% in the Helex device (W.L. Gore and Associates, Flagstaff, Arizona); and 0% in the Amplatzer device (AGA Medical Corp., Golden Valley, Minnesota). The difference between the Amplatzer device on one hand and the CardioSEAL device, the StarFLEX device, and the PFO-Star device on the other hand was significant (p < 0.05). A pre-thrombotic disorder as a possible cause of the thrombus was found in two PFO patients. Post-procedure atrial fibrillation (n = 4) and persistent atrial septal aneurysm (n = 4) had been found as significant predictors for thrombus formation (p < 0.05). In 17 of the 20 patients, the thrombus resolved under anticoagulation therapy with heparin or warfarin. In three patients, the thrombus was removed surgically. CONCLUSIONS: The incidence of thrombus formation on closure devices is low. The thrombus usually resolves under anticoagulation therapy.


Asunto(s)
Defectos del Tabique Interatrial/terapia , Prótesis e Implantes/efectos adversos , Trombosis/epidemiología , Trombosis/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Anticoagulantes/uso terapéutico , Cateterismo Cardíaco/métodos , Ecocardiografía Transesofágica , Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 58(1): 111-3, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12508211

RESUMEN

From December 1998 to August 2001, transcatheter closure of patent foramen ovale (PFO) with an Amplatzer PFO occluder has been successfully performed in our center in 102 patients without severe complications. We are reporting the first known case of cardiac perforation by an Amplatzer PFO occluder.


Asunto(s)
Oclusión con Balón/efectos adversos , Taponamiento Cardíaco/etiología , Atrios Cardíacos/lesiones , Lesiones Cardíacas/etiología , Defectos del Tabique Interatrial/terapia , Complicaciones Posoperatorias , Adulto , Taponamiento Cardíaco/diagnóstico por imagen , Ecocardiografía Transesofágica , Femenino , Fluoroscopía , Atrios Cardíacos/diagnóstico por imagen , Lesiones Cardíacas/diagnóstico por imagen , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...