Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 41(9): 1707-1711, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32586958

RESUMEN

We report a case of bifacial weakness with paresthesia, a recognized Guillain-Barré syndrome subtype characterized by rapidly progressive facial weakness and paresthesia without ataxia or other cranial neuropathies, which was temporally associated with antecedent coronavirus 2019 (COVID-19). This case highlights a potentially novel but critically important neurologic association of the COVID-19 disease process. Herein, we detail the clinicoradiologic work-up and diagnosis, clinical course, and multidisciplinary medical management of this patient with COVID-19. This case is illustrative of the increasingly recognized but potentially underreported neurologic manifestations of COVID-19, which must be considered and further investigated in this pandemic disease.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/complicaciones , Parálisis Facial/etiología , Síndrome de Guillain-Barré/complicaciones , Parestesia/etiología , Neumonía Viral/complicaciones , COVID-19 , Humanos , Masculino , Pandemias , SARS-CoV-2 , Adulto Joven
2.
Appl Radiat Isot ; 125: 108-112, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28427042

RESUMEN

In this work, verification data for 11 HPGe detectors from two different manufacturers and three different intrinsic configurations were analyzed in respect to the stability of both the efficiency and resolution for the 122keV peak from 57Co and the 1332keV peak from 60Co. The results allow a discussion about the stability of these parameters over time (in some cases, almost 15 years), their sensitivity to imminent detector failures and their performance after a failure has been corrected; moreover, the results show a clear correlation between the manufacturer or configuration and the long-term performance of the detector.

3.
Appl Radiat Isot ; 69(7): 960-4, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21478022

RESUMEN

The values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn and (68)Zn(n,γ)(69m)Zn reactions were determined experimentally. The irradiations were performed near the core of the IEA-R1 3.5MW nuclear research reactor of the Nuclear and Energy Research Institute - IPEN-CNEN/SP, in São Paulo, Brazil. The results for the neutron field parameters f and α were 49.7(19) and -1.1(31)×10(-3), respectively. The resulting values of k(0) and Q(0) for (64)Zn(n,γ)(65)Zn reaction were 5.63(8)×10(-3) and 1.69(6), respectively, and the corresponding values for (68)Zn(n,γ)(69m)Zn reaction were 4.00(6)×10(-4) and 2.34(4), respectively. These results were compared with the literature.

4.
Appl Radiat Isot ; 59(4): 263-6, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14522234

RESUMEN

A neutron irradiator has been assembled at IPEN facilities to perform qualitative-quantitative analysis of many materials using thermal and fast neutrons outside the nuclear reactor premises. To establish the prototype specifications, the neutron flux distribution and the absorbed dose rates were calculated using the MCNP computer code. These theoretical predictions then allow one to discuss the optimum irradiator design and its performance.


Asunto(s)
Americio , Berilio , Terapia por Captura de Neutrón de Boro/métodos , Neutrones , Radiometría/instrumentación , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Marcaje Isotópico/instrumentación , Marcaje Isotópico/métodos , Modelos Químicos , Dosis de Radiación , Radiofármacos/análisis , Radiofármacos/síntesis química , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA