Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
1.
BMC Med Inform Decis Mak ; 24(1): 131, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38773484

RESUMEN

INTRODUCTION: Open globe injuries (OGI) represent a main preventable reason for blindness and visual impairment, particularly in developing countries. The goal of this study is evaluating key variables affecting the prognosis of open globe injuries and validating internally and comparing different machine learning models to estimate final visual acuity. MATERIALS AND METHODS: We reviewed three hundred patients with open globe injuries receiving treatment at Khatam-Al-Anbia Hospital in Iran from 2020 to 2022. Age, sex, type of trauma, initial VA grade, relative afferent pupillary defect (RAPD), zone of trauma, traumatic cataract, traumatic optic neuropathy (TON), intraocular foreign body (IOFB), retinal detachment (RD), endophthalmitis, and ocular trauma score (OTS) grade were the input features. We calculated univariate and multivariate regression models to assess the association of different features with visual acuity (VA) outcomes. We predicted visual acuity using ten supervised machine learning algorithms including multinomial logistic regression (MLR), support vector machines (SVM), K-nearest neighbors (KNN), naïve bayes (NB), decision tree (DT), random forest (RF), bagging (BG), adaptive boosting (ADA), artificial neural networks (ANN), and extreme gradient boosting (XGB). Accuracy, positive predictive value (PPV), recall, F-score, brier score (BS), Matthew correlation coefficient (MCC), receiver operating characteristic (AUC-ROC), and calibration plot were used to assess how well machine learning algorithms performed in predicting the final VA. RESULTS: The artificial neural network (ANN) model had the best accuracy to predict the final VA. The sensitivity, F1 score, PPV, accuracy, and MCC of the ANN model were 0.81, 0.85, 0.89, 0.93, and 0.81, respectively. In addition, the estimated AUC-ROC and AUR-PRC of the ANN model for OGI patients were 0.96 and 0.91, respectively. The brier score and calibration log-loss for the ANN model was 0.201 and 0.232, respectively. CONCLUSION: As classic and ensemble ML models were compared, results shows that the ANN model was the best. As a result, the framework that has been presented may be regarded as a good substitute for predicting the final VA in OGI patients. Excellent predictive accuracy was shown by the open globe injury model developed in this study, which should be helpful to provide clinical advice to patients and making clinical decisions concerning the management of open globe injuries.


Asunto(s)
Lesiones Oculares Penetrantes , Aprendizaje Automático , Agudeza Visual , Humanos , Masculino , Femenino , Adulto , Pronóstico , Persona de Mediana Edad , Agudeza Visual/fisiología , Irán , Adulto Joven , Adolescente , Redes Neurales de la Computación , Anciano
2.
Cornea ; 43(2): 154-158, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37186807

RESUMEN

PURPOSE: To investigate the visual, refractive, and biomechanical outcomes of small incision lenticule extraction (SMILE) with two different cap thicknesses. METHODS: Thirty-four patients were included in this prospective, randomized, contralateral eye study. Subjects were randomized to receive SMILE surgery with a 110-m cap thickness in one eye and 145-µm cap thickness in the fellow eye. Uncorrected and corrected distance visual acuity, contrast sensitivity (CS), total higherorder aberrations (THOAs) and corneal biomechanical properties were compared 3 months after surgery. RESULTS: Postoperative refractive and visual outcomes, CS and THOAs were similar between the two groups ( P > 0.05 for all parameters). At 3 months postoperatively, there was a significant difference in Corvis ST Biomechanical Index (CBI); stiffness parameter at first applanation (SP A1), and Integrated Radius between the two groups (all P < 0.05). CONCLUSIONS: Eyes with thicker SMILE corneal caps showed no advantage regarding visual acuity, CS and THOAs over eyes with thinner caps. However, higher cap thickness may result in better corneal biomechanical properties postoperatively.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Humanos , Sustancia Propia/cirugía , Estudios Prospectivos , Miopía/cirugía , Córnea/cirugía , Agudeza Visual , Refracción Ocular , Láseres de Excímeros/uso terapéutico
4.
Sci Rep ; 13(1): 20586, 2023 11 23.
Artículo en Inglés | MEDLINE | ID: mdl-37996439

RESUMEN

Detecting clinical keratoconus (KCN) poses a challenging and time-consuming task. During the diagnostic process, ophthalmologists are required to review demographic and clinical ophthalmic examinations in order to make an accurate diagnosis. This study aims to develop and evaluate the accuracy of deep convolutional neural network (CNN) models for the detection of keratoconus (KCN) using corneal topographic maps. We retrospectively collected 1758 corneal images (978 normal and 780 keratoconus) from 1010 subjects of the KCN group with clinically evident keratoconus and the normal group with regular astigmatism. To expand the dataset, we developed a model using Variational Auto Encoder (VAE) to generate and augment images, resulting in a dataset of 4000 samples. Four deep learning models were used to extract and identify deep corneal features of original and synthesized images. We demonstrated that the utilization of synthesized images during training process increased classification performance. The overall average accuracy of the deep learning models ranged from 99% for VGG16 to 95% for EfficientNet-B0. All CNN models exhibited sensitivity and specificity above 0.94, with the VGG16 model achieving an AUC of 0.99. The customized CNN model achieved satisfactory results with an accuracy and AUC of 0.97 at a much faster processing speed compared to other models. In conclusion, the DL models showed high accuracy in screening for keratoconus based on corneal topography images. This is a development toward the potential clinical implementation of a more enhanced computer-aided diagnosis (CAD) system for KCN detection, which would aid ophthalmologists in validating the clinical decision and carrying out prompt and precise KCN treatment.


Asunto(s)
Aprendizaje Profundo , Queratocono , Humanos , Queratocono/diagnóstico por imagen , Estudios Retrospectivos , Redes Neurales de la Computación , Computadores
5.
J Cataract Refract Surg ; 49(12): 1285-1289, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982777

RESUMEN

A 24-year-old man was referred for postrefractive surgery evaluation. The patient had a history of uneventful laser in situ keratomileusis (LASIK) in both eyes 3 months previously. According to the surgeon who originally performed the surgery, on slitlamp examination, only microstriae in the left eye was detected on postoperative day 1 and a more conservative follow-up approach was adopted without further immediate intervention. The patient returned only 3 months after surgery, complaining of low vision in the left eye that, according to the patient, had been present since postoperative week 2. The patient was then referred for examination and surgical procedure with a diagnosis of significant postoperative striae. The slitlamp examination revealed a LASIK flap with striae, epithelial filling, and a wrinkled appearance (Figure 1JOURNAL/jcrs/04.03/02158034-202312000-00017/figure1/v/2023-11-20T151558Z/r/image-tiff). There were no signs of infection or inflammation. Originally, the LASIK flap was programmed to be 110 µm. Preoperative manifest refraction in the right eye was -5.25 (20/20) and in the left eye was -5.25 (20/20). Assuming it is a case of late-approach LASIK flap striae, how would you proceed? Would you try to hydrate and lift the flap and just reposition it? Would you avoid lifting and associate phototherapeutic keratectomy (PTK) with excimer laser on top of the flap? Would you consider topo-guided surgery with regularization of the visual axis or even amputation of the flap?


Asunto(s)
Queratomileusis por Láser In Situ , Queratectomía Fotorrefractiva , Masculino , Humanos , Adulto Joven , Adulto , Sustancia Propia/cirugía , Agudeza Visual , Queratectomía Fotorrefractiva/métodos , Láseres de Excímeros/uso terapéutico , Refracción Ocular
6.
Int Ophthalmol ; 43(10): 3615-3621, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37393605

RESUMEN

INTRODUCTION: In thyroid eye disease (TED), all ocular components and adnexa such as extraocular muscles, orbital adipose tissues, eyelids, and tear glands could be affected. This study aimed to study the orbital biomechanical parameters in patients with TED, in terms of differences with healthy individuals and correlation with clinical findings, using Corvis ST (CST, Oculus Wetzlar). MATERIALS AND METHODS: In this study, 26 consecutive patients with TED were recruited. Demographic data were collected, and patients with TED were assessed for exophthalmos, intraocular pressure, and clinical activity score. Biomechanical response parameters of one randomly-chosen eye of each patient, including whole eye movement length (WEMl) and time (WEMt), were evaluated by the CST, and data were compared between patients and age- and gender-matched healthy controls. RESULTS: The mean age was 39.88 ± 11.61 years old for patients with TED and 34.38 ± 8.57 years old for the healthy subjects. Nine out of 26 patients with TED and nine of 26 healthy individuals were male. The median duration of thyroid disease was 36 (IQR 54) months and the median duration of thyroid ophthalmopathy was 27 (IQR 27) months. Four out of 26 patients (7.7%) had active disease. The mean WEMl was 206.15 ± 61.58 µm in the TED group and 254.23 ± 64.01 µm in the healthy group, the difference of which was statistically significant (p = 0.008). The median of WEMt was 20.90 (1.15) msec in the TED group and 21.45 (0.93) msec in the healthy group (p < 0.001). Also, the mean of WEMl and WEMt were lower in patients with active disease compared to patients with quiescent disease. CONCLUSION: The CST-derived WEMl was significantly smaller in patients with thyroid eye disease compared to normal subjects. The WEMl and WEMt were relatively shorter in the patients with active TED compared to the patients with quiescent TED, although small numbers of patients with active TED limits took a statistically significant conclusion. WEMl and WEMt might be useful in evaluating the compliance of the orbit in patients with TED.


Asunto(s)
Oftalmopatía de Graves , Humanos , Masculino , Adulto , Persona de Mediana Edad , Femenino , Oftalmopatía de Graves/diagnóstico , Órbita/diagnóstico por imagen , Músculos Oculomotores , Tonometría Ocular , Párpados
7.
Clin Exp Optom ; 106(3): 257-262, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35188874

RESUMEN

CLINICAL RELEVANCE: Dry eye disease (DED) and vitamin D deficiency are both common clinical entities. Vitamin D has been reported to play a significant role in ocular surface homeostasis. BACKGROUND: This study aimed to determine the therapeutic effect of oral vitamin D supplementation in dry eye disease patients with vitamin D deficiency. METHODS: A randomized, controlled study was completed in 100 patients with dry eye disease and concurrent vitamin D deficiency (< 20 ng/ml). Participants were randomly allocated to 8 weeks of oral vitamin D supplementation with both groups receiving conventional dry eye treatment with artificial tears. Schirmer's, tear break-up time (TBUT) and osmolarity tests were measured before and after eight weeks of treatment. RESULTS: The mean age of participants was 36.8 ± 8.56 years in the treatment group (n: 50) and 34.8 ± 10.13 year in the control group (n: 50). After eight weeks of treatment the mean differences in Schirmer's, TBUT and tear osmolarity were 2.38 ± 1.55 mm, 3.95 ± 1.48 s and -16.9 ± 6.28 mOsm/L, respectively in the treatment group, and 0.7 ± 0.86 mm, 0.92 ± 1.57s and -3.34 ± 2.0 mOsm/L respectively in the control group (p < 0.001 for all parameters). The treatment group demonstrated a more significant improvement than the control group in Schirmer's, TBUT and osmolarity values (p < 0.001). CONCLUSION: Vitamin D supplementation as an adjuvant to routine dry eye treatment improves ocular surface hemostasis parameters, results in better tear stability and a more improved tear osmolarity in patients with vitamin D deficiency.


Asunto(s)
Síndromes de Ojo Seco , Deficiencia de Vitamina D , Humanos , Adulto , Persona de Mediana Edad , Vitamina D , Síndromes de Ojo Seco/tratamiento farmacológico , Síndromes de Ojo Seco/etiología , Deficiencia de Vitamina D/complicaciones , Deficiencia de Vitamina D/tratamiento farmacológico , Ojo , Lágrimas , Concentración Osmolar , Suplementos Dietéticos
8.
Cornea ; 42(3): 308-312, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-35587897

RESUMEN

PURPOSE: The aim of this study was to evaluate the corneal higher-order aberrations (HOAs) in first-degree relatives of patients with keratoconus (KCN) and compare with the normal population. METHODS: In this prospective comparative study, 210 eyes from 105 family members of 28 patients with KCN and 210 normal eyes of 105 controls were enrolled. In each eye, corneal topography, tomography, and aberrometry were performed and compared between the 2 groups. RESULTS: This study included 61 female (58.1%) and 44 male participants (41.9%) and 105 age-matched and sex-matched controls with normal topographic cornea. In 14 of 105 first-degree relatives (13.33%) of patients with KCN, KCN was diagnosed with a male preponderance (71.5% male, 28.5% female). Tomographic indices and irregularity indices in 3 and 5 mm zone in Orbscan were significantly higher in the relative group. In addition, other irregularity indices of TMS-4 topography including surface regularity index, surface asymmetry index, difference sector index, SDP, and irregular astigmatism index were significantly higher in family members of patients with KCN. The most prevalent topographic pattern in the control group was the symmetric bowtie (57.1%) and in the relative group was the asymmetric bowtie (39.5%). In addition, significantly thinnest corneal pachymetry was detected in the relative group. Root mean square of all HOAs including vertical trefoil, vertical coma, horizontal coma, horizontal trefoil, quadrifoil, and fourth-order spherical aberrations were significantly greater in the relative group than controls. CONCLUSIONS: Owing to the high prevalence of undiagnosed KCN susceptibility in family members with KCN, keratorefractive surgery should be considered cautiously in these individuals. In addition, comprehensive preoperative examination should be considered to detect subtle topographic and HOAs in these individuals.


Asunto(s)
Queratocono , Humanos , Masculino , Femenino , Queratocono/diagnóstico , Queratocono/genética , Estudios Prospectivos , Coma , Córnea , Topografía de la Córnea/métodos
9.
Am J Ophthalmol ; 251: 126-142, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36549584

RESUMEN

PURPOSE: To optimize artificial intelligence (AI) algorithms to integrate Scheimpflug-based corneal tomography and biomechanics to enhance ectasia detection. DESIGN: Multicenter cross-sectional case-control retrospective study. METHODS: A total of 3886 unoperated eyes from 3412 patients had Pentacam and Corvis ST (Oculus Optikgeräte GmbH) examinations. The database included 1 eye randomly selected from 1680 normal patients (N) and from 1181 "bilateral" keratoconus (KC) patients, along with 551 normal topography eyes from patients with very asymmetric ectasia (VAE-NT), and their 474 unoperated ectatic (VAE-E) eyes. The current TBIv1 (tomographic-biomechanical index) was tested, and an optimized AI algorithm was developed for augmenting accuracy. RESULTS: The area under the receiver operating characteristic curve (AUC) of the TBIv1 for discriminating clinical ectasia (KC and VAE-E) was 0.999 (98.5% sensitivity; 98.6% specificity [cutoff: 0.5]), and for VAE-NT, 0.899 (76% sensitivity; 89.1% specificity [cutoff: 0.29]). A novel random forest algorithm (TBIv2), developed with 18 features in 156 trees using 10-fold cross-validation, had a significantly higher AUC (0.945; DeLong, P < .0001) for detecting VAE-NT (84.4% sensitivity and 90.1% specificity; cutoff: 0.43; DeLong, P < .0001) and a similar AUC for clinical ectasia (0.999; DeLong, P = .818; 98.7% sensitivity; 99.2% specificity [cutoff: 0.8]). Considering all cases, the TBIv2 had a higher AUC (0.985) than TBIv1 (0.974; DeLong, P < .0001). CONCLUSIONS: AI optimization to integrate Scheimpflug-based corneal tomography and biomechanical assessments augments accuracy for ectasia detection, characterizing ectasia susceptibility in the diverse VAE-NT group. Some patients with VAE may have true unilateral ectasia. Machine learning considering additional data, including epithelial thickness or other parameters from multimodal refractive imaging, will continuously enhance accuracy. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.


Asunto(s)
Queratocono , Humanos , Estudios Retrospectivos , Topografía de la Córnea/métodos , Queratocono/diagnóstico , Inteligencia Artificial , Dilatación Patológica/diagnóstico , Paquimetría Corneal/métodos , Estudios Transversales , Córnea/diagnóstico por imagen , Curva ROC , Tomografía/métodos
10.
J Curr Ophthalmol ; 35(2): 153-158, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38250485

RESUMEN

Purpose: To assess the agreement between biometric parameters measured by a spectral-domain optical coherence tomography optical biometer device (Optopol Revo NX) with a validated swept-source biometer (IOLMaster 700) and a validated optical low-coherence reflectometry biometer (Lenstar LS 900), in cataract surgery candidates. Methods: In this prospective comparative study, 100 patients (100 eyes) who were eligible for cataract surgery were involved. Bland-Altman plots were used to assess agreement between devices for biometric parameters including axial length (AL), anterior chamber depth (ACD), lens thickness (LT), and central corneal thickness (CCT). Results: AL measurements were successful in 82 eyes (82.0%) with Revo NX, in 91 eyes (91.0%) with Lenstar LS 900, and in 97 eyes (97.0%) with IOLMaster 700. When Revo NX was compared to IOL Master 700 and Lenstar LS 900, the mean differences were as follows: -0.02 ± 0.02 mm and -0.02 ± 0.03 mm (P = 0.313, P = 0.525) for AL, 0.01 ± 0.03 mm and 0.10 ± 0.03 mm (P = 0.691, P = 0.002) for ACD, -0.15 ± 0.03 mm and 0.001 ± 0.04 mm (P < 0.001, P = 0.95) for LT, and -2.29 ± 0.92 µm, and 0.73 ± 1.43 µm (P = 0.015, P = 0.612) for CCT. Three devices were highly correlated for AL, ACD, LT, and CCT (interclass correlation coefficient > 0.75). Bland-Altman plots showed a narrower 95% limit of agreement (-0.35 to 0.31) between Revo NX and IOLMaster 700 in measuring AL. Conclusions: Despite the higher measurement failure rate in eyes with cataract, the Revo NX showed very good agreement with the IOLMaster 700 and Lenstar LS 900 optical biometers in measuring AL, ACD, LT, and CCT. However, ACD and LT measurements cannot be considered interchangeable between these devices.

11.
Biotechnol Prog ; 38(5): e3278, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35652279

RESUMEN

The development of gene delivery systems is essential to improve their transfection efficiency and cytotoxicity. Combination of lipid and polymeric nanoparticles with the characteristics of both systems have been considered as a next-generation gene delivery platform. In the current study, we designed a novel and efficient targeted gene delivery system based on liposome and PAMAM dendrimer in cancer cells. Two polymeric formulations containing polyamidoamine-TAT (PAMAM-TAT) and PAMAM-TAT-Hyaluronic acid (HA) and two lipopolymeric carriers including PAMAM-TAT-Liposome and PAMAM-TAT-HA-Liposome were complexed with the enhanced green fluorescent protein (EGFP) plasmid and then evaluated in terms of physicochemical characteristics. The cytotoxicity and transfection efficiency of these synthetized carriers were accomplished against murine colon carcinoma cell line (C26). The biodistribution of polyplexes and lipoployplexes was also evaluated in the C26 tumor bearing mice. The results showed no significant toxicity for all designed nanoparticles (NPs) in C/P4. The highest gene expression was observed using lipopolyplex PAMAM-TAT-HA-Liposome in C/P4 (ratio polymer/DNA; wt/wt). Biodistribution study demonstrated more aggregation of targeted lipopolyplex in tumor cells than other nanoparticles (NPs). It could be concluded that the developed targeted lipopolymeric complex could serve as promising nanotherapeutic system for gene therapy.


Asunto(s)
Dendrímeros , Liposomas , Animales , Línea Celular Tumoral , ADN , Técnicas de Transferencia de Gen , Ácido Hialurónico , Lípidos , Ratones , Péptidos , Poliaminas , Distribución Tisular
12.
Int Ophthalmol ; 42(5): 1563-1571, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35094228

RESUMEN

PURPOSE: To compare optical and visual performances of two one-piece aspherical implanted intraocular lenses (IOLs) following phacoemulsification cataract surgery in a contralateral eye study. METHODS: In this prospective randomized parallel-group study, 25 patients with bilateral age-related cataract were implanted in one eye with the EnVista IOL (MX60, Bausch & Lomb Corporations, Rochester, NY, USA) and the Acrysof IQ IOL (Acrysof IQ SN60WF, Alcon Surgical Laboratories, Fort Worth, TX, USA) in the other eye. Uncorrected and corrected distance visual acuity (UDVA, CDVA), refractive status, higher-orders aberrations (HOAs) in 5 and 6 mm pupil size, contrast sensitivity (CS) with and without glare, color vision status, and patient satisfaction were assessed in the two eyes at 1 and 3 months after surgery. RESULTS: There was no significant difference in CDVA (P > 0.99), UDVA (P = 0.46), spherical equivalent refractive error (P = 0.63), CS with and without glare across different spatial frequencies, color vision, and root mean square (RMS) of aberrometric values between the two IOLs after 3-month follow-up. Spherical aberration with 5 and 6 mm pupil sizes (P = 0.02) and horizontal coma with a 6 mm pupil size (P < 0.001) were lower with the EnVista IOL. Patient's satisfaction showed no cases of dissatisfaction, and most patients were highly or moderately satisfied with both IOLs. CONCLUSION: The visual and optical performance of eyes implanted with the EnVista IOL or the Acrysof IQ IOL was similar, although the aberration profile differed.


Asunto(s)
Catarata , Lentes Intraoculares , Facoemulsificación , Sensibilidad de Contraste , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos , Diseño de Prótesis
13.
Cornea ; 41(7): 886-893, 2022 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34690272

RESUMEN

PURPOSE: The aim of this study was to evaluate and compare early corneal biomechanical changes after small-incision lenticule extraction (SMILE) and photorefractive keratectomy (PRK). METHODS: The study comprised 74 patients eligible for refractive surgery, equally allocated to PRK (37 patients) and SMILE (37 patients). Corneal biomechanical properties were recorded and compared between the 2 groups at preoperatively and 3 months after surgery using a dynamic ultra-high-speed Scheimpflug camera equipped with a noncontact tonometer. RESULTS: Both procedures significantly affected corneal biomechanical properties at 3 months after surgery. Patients in the PRK group showed significantly better results for deformation amplitude ratio (DA ratio) ( P = 0.03), maximum inverse radius (InvRadMax) ( P = 0.02), and A2 time ( P = 0.03). The mean changes in DA ratio, HC radius, InvRadMax, and Ambrosio relational thickness were significantly higher in the SMILE group in comparison with those of the PRK group (all, P < 0.05). In both groups, change in CCT was significantly correlated with changes in DA ratio and InvRadMax ( P < 0.05). CONCLUSIONSS: Both SMILE and PRK refractive surgeries significantly altered corneal biomechanical properties but the changes were more prominent after SMILE.


Asunto(s)
Cirugía Laser de Córnea , Miopía , Queratectomía Fotorrefractiva , Herida Quirúrgica , Fenómenos Biomecánicos , Córnea/cirugía , Cirugía Laser de Córnea/métodos , Humanos , Láseres de Excímeros/uso terapéutico , Miopía/cirugía , Queratectomía Fotorrefractiva/métodos , Herida Quirúrgica/cirugía
14.
Clin Exp Optom ; 105(7): 687-693, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-34538227

RESUMEN

CLINICAL RELEVANCE: Meibomian gland dysfunction is the main cause of evaporative dry eye disease and can lead to ocular discomfort and ocular surface damage. Early diagnosis and management of this condition can prevent its impact on patients 'visual health and quality of life. BACKGROUND: In the last decade, intense pulsed light therapy (IPL) has been introduced as a therapeutic option for patients with meibomian gland dysfunction (MGD). Various treatment modalities and protocols have been reported to increase the efficacy of this technique. This study aimed to assess the efficacy of a novel five-flash IPL technique in combination with home-based therapy and to compare it with conventional home care alone in patients with MGD. METHODS: In a randomised controlled trial, 100 symptomatic MGD patients were enrolled. The treatment group underwent three sessions of a five-flash IPL therapy. For all participants, eyelid warming, lid hygiene and lubricant therapy was prescribed. Ocular surface parameters were compared for control and treatment groups. RESULTS: Ocular Surface Disease Index (OSDI), non-invasive keratograph tear break up time (NIKBUT), fluorescein TBUT, MG expressibility, meibum quality and tear osmolarity were improved at follow up visits in both groups (p < 0.05). On day 75, NIKBUT was significantly higher in the IPL group (p = 0.045). The IPL treatment effect was not statistically significant (p > 0.05), except for bulbar and limbal hyperaemia (p = 0.02 and p = 0.02). In both groups, younger patients showed more improvement in NIKBUT (p = 0.02, r = -0.32; p < 0.001, r = -0.52). CONCLUSION: IPL therapy combined with conventional home-based therapy, and home care alone are both effective for patients with MGD. IPL may have an additional role in the improvement of ocular hyperaemia.


Asunto(s)
Síndromes de Ojo Seco , Hiperemia , Tratamiento de Luz Pulsada Intensa , Disfunción de la Glándula de Meibomio , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/terapia , Humanos , Hiperemia/complicaciones , Tratamiento de Luz Pulsada Intensa/efectos adversos , Tratamiento de Luz Pulsada Intensa/métodos , Disfunción de la Glándula de Meibomio/terapia , Glándulas Tarsales , Calidad de Vida , Lágrimas
15.
J Curr Ophthalmol ; 34(3): 357-363, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36644473

RESUMEN

Purpose: To present a case of asymmetric progressive corneal ectasia following femtosecond laser-assisted small-incision lenticule extraction. Methods: After obtaining a patient's consent, preoperative and postoperative findings were represented in this case report. Results: A 29-year-old woman presented with normal preoperative Placido disk-based corneal topography and tomographic findings. The corrected refractive error was -4.00 and -4.50 -1.00 × 177 in the right and left eye, respectively, with a maximal lenticule thickness of 87 and 115 µm OD/OS. Twenty months postoperatively, the patient presented with decreased vision in the left eye and mild ectatic changes in corneal shape in both eyes. The retrospective evaluation of the integrated rotating Scheimpflug tomography (Pentacam; Oculus, Wetzlar, Germany) and corneal biomechanical (Corvis ST) assessment revealed moderate susceptibility for corneal ectasia in the right eye and a significant corneal ectasia in the left eye. Conclusion: This case corroborates the need for an enhanced multimodal approach to characterize the risk for postoperative corneal ectasia after laser vision correction.

16.
J Curr Ophthalmol ; 33(3): 272-276, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34765814

RESUMEN

PURPOSE: To assess the therapeutic efficacy of a combinational therapy, including conventional treatment and intense pulsed light (IPL) technique on sleep quality of patients with meibomian gland dysfunction (MGD). METHODS: Fifty participants with a clinical diagnosis of MGD were enrolled in this study. Participants underwent three sessions of IPL therapy. There was a 2-week interval between IPL sessions 1 and 2 and 1 month between sessions 2 and 3. Treatment was supplemented with conventional home-based therapy (including lid hygiene, warm compress, eyelid massage, and lid margin scrub) for MGD. Dry eye symptomatology, tear film, and ocular surface parameters were evaluated at baseline (day 0) and days 15, 45, and 75. Sleep quality was assessed before and after the study using Pittsburgh Sleep Quality Index (PSQI). RESULTS: PSQI components improved significantly at day 75 in comparison with the baseline (all P < 0.05). Ocular Surface Disease Index (OSDI) score, noninvasive Keratograph tear break-up time (NIKBUT), fluorescein tear break-up time (FTBUT), meibomian gland expressibility, meibum quality score, and tear osmolarity improved at follow-up visits (P < 0.05). Younger patients showed more improvement in NIKBUT, sleep quality, and duration (P = 0.024, P = 0.047, and P = 0.008). Sleep latency decreased with increased NIKBUT and FTBUT and decreased OSDI score (P = 0.001, P = 0.005, and P = 0.041). CONCLUSIONS: The treatment of MGD is effective for improving sleep quality. Younger patients may preferentially benefit from the treatment.

17.
Am J Ophthalmol ; 229: 45-51, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33905746

RESUMEN

PURPOSE: This study is aimed at comparing the effects of tea tree oil (TTO) shampoo with regular eyelid shampoo on the treatment of meibomian gland dysfunction (MGD) signs and symptoms. DESIGN: Double-masked randomized clinical trial METHODOLOGY: Forty patients with MGD were treated by daily eyelid scrubbing with TTO shampoo in one eye and regular eyelid shampoo in the other one. Before treatment and then after 1 and 3 months, the effect on ocular surface symptoms, tear production and stability, and conjunctival and eyelid signs of the 2 eyes were compared. RESULTS: Plugging and capping of meibomian gland orifices, foamy tear, glands expressibility, 5-Item Dry Eye Questionnaire score (DEQ5), and tear breakup time were improved more significantly in TTO shampoo-treated eyes (capping P = .050, plugging and glands expressibility P = .001, others P < .001). In spite of improvement in both eyes, scores of meibum quality, conjunctival hyperemia, corneal and conjunctival staining, and Schirmer1 test value showed no statistically significant difference between the eyes (P = .06, .187, .192, .19, respectively). Moreover, eyelid margin telangiectasia resolved only in TTO shampoo-treated eyes (P < .001). Trichiasis and distichiasis changed in neither group (P > .99). Furthermore, ocular surface irritation during scrubbing was more common with TTO shampoo (P = .002). CONCLUSION: TTO shampoo was found to be more efficient than regular eyelid shampoo in controlling MGD signs and symptoms although ocular surface irritation during its application was more frequent.


Asunto(s)
Síndromes de Ojo Seco , Enfermedades de los Párpados , Disfunción de la Glándula de Meibomio , Aceite de Árbol de Té , Síndromes de Ojo Seco/tratamiento farmacológico , Enfermedades de los Párpados/diagnóstico , Enfermedades de los Párpados/tratamiento farmacológico , Humanos , Glándulas Tarsales , Aceite de Árbol de Té/uso terapéutico , Lágrimas
18.
Eur J Ophthalmol ; 31(1): 88-95, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31578887

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the effects of goniotomy on patients with primary angle-closure glaucoma who underwent "phacoemulsification and visco-goniosynechialysis." MATERIALS AND METHODS: This prospective randomized clinical trial was carried out on 63 eyes of 61 patients (48-85 years) with primary angle-closure glaucoma who were enrolled. The subjects were randomly assigned into two groups. In the first group (32 eyes) and the second group (31 eyes), the patients underwent "phacoemulsification + visco-goniosynechialysis + goniotomy" and "phacoemulsification + visco-goniosynechialysis," respectively. Intraocular pressure and antiglaucoma medication were evaluated (1 week, as well as 1, 3, and 6 months after the surgery). Anterior segment optical coherence tomography parameters (Casia, Tomey, USA) and goniotomy were evaluated preoperatively and 6 months after the surgery. RESULTS: The mean intraocular pressure lowering the effects in the "phacoemulsification + visco-goniosynechialysis + goniotomy" group was higher than that in the "phacoemulsification + visco-goniosynechialysis" group (6.93 and 4.6, respectively). Furthermore, the difference in intraocular pressure between the two groups was significant at 3 months (P = 0.014) and 6 months (P = 0.021) after the surgery. There was no difference in anterior segment optical coherence tomography findings before the intervention; however, after the intervention, the anterior segment optical coherence tomography indices were significantly different between the two groups. Moreover, the difference in "phacoemulsification + visco-goniosynechialysis + goniotomy" indices was more than the changes in the "phacoemulsification + visco-goniosynechialysis" group. CONCLUSION: The results of this study showed that phacoemulsification + visco-goniosynechialysis + goniotomy is a more effective surgery than phacoemulsification + visco-goniosynechialysis alone in undercounted primary angle-closure glaucoma.


Asunto(s)
Segmento Anterior del Ojo/cirugía , Glaucoma de Ángulo Cerrado/cirugía , Facoemulsificación/métodos , Trabeculectomía/métodos , Anciano , Anciano de 80 o más Años , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/fisiopatología , Enfermedad Crónica , Femenino , Glaucoma de Ángulo Cerrado/diagnóstico por imagen , Glaucoma de Ángulo Cerrado/fisiopatología , Humanos , Presión Intraocular/fisiología , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular
19.
Ocul Immunol Inflamm ; 29(1): 66-75, 2021 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-32589483

RESUMEN

Purpose: The purpose of this study is to assess the pooled prevalence of meibomian gland dysfunction (MGD) and evaluate its risk factors by gender, age, and ethnicity.Methods: Articles were searched reporting the prevalence of MGD from PubMed, Scopus, Web of Science, and Embase databases.Results: The estimated pooled prevalence of MGD was 0.358 (95% CI 0.26-0.46; I2: 99.57%). The prevalence of MGD was 0.358 (95% CI 0.24-0.50) in clinical and 0.359 (95% CI 0.22-0.52) in population-based studies. Men were more prone to MGD than women (OR: 1.24, 95% CI 1.01-1.52, p = 0.034). The rate of MGD was between 21.2% and 29.5% in Africans and Caucasians, to 71.0% in Arabs, and 67.5% in Hispanics.Conclusion: MGD is a quite prevalent disorder with an estimated pooled prevalence of 35.8%. Men are more prone to MGD than women. There is a large variation between studies in terms of quality, sample size, age ranges, diagnostic criteria, and ethnicity.


Asunto(s)
Etnicidad , Disfunción de la Glándula de Meibomio/etnología , Medición de Riesgo/métodos , Distribución por Edad , Salud Global , Humanos , Prevalencia , Factores de Riesgo , Distribución por Sexo
20.
BMC Public Health ; 20(1): 1637, 2020 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-33138802

RESUMEN

BACKGROUND: The rising burden of premature mortality for Non-Communicable Diseases (NCDs) in developing countries necessitates the institutionalization of a comprehensive surveillance framework to track trends and provide evidence to design, implement, and evaluate preventive strategies. This study aims to conduct an organization-based prospective cohort study on the NCDs and NCD-related secondary outcomes in adult personnel of the Mashhad University of Medical Sciences (MUMS) as main target population. METHODS: This study was designed to recruit 12,000 adults aged between 30 and 70 years for 15 years. Baseline assessment includes a wide range of established NCD risk factors obtaining by face-to-face interview or examination. The questionnaires consist of demographic and socioeconomic characteristics, lifestyle pattern, fuel consumption and pesticide exposures, occupational history and hazards, personal and familial medical history, medication profile, oral hygiene, reproduction history, dietary intake, and psychological conditions. Examinations include body size and composition test, abdominopelvic and thyroid ultrasonography, orthopedic evaluation, pulse wave velocity test, electrocardiography, blood pressure measurement, smell-taste evaluation, spirometry, mammography, and preferred tea temperature assessment. Routine biochemical, cell count, and fecal occult blood tests are also performed, and the biological samples (i.e., blood, urine, hair, and nail) are stored in preserving temperature. Annual telephone interviews and repeated examinations at 5-year intervals are planned to update information on health status and its determinants. RESULTS: A total of 5287 individuals (mean age of 43.9 ± 7.6 and 45.9% male) were included in the study thus far. About 18.5% were nurses and midwives and 44.2% had at least bachelor's degree. Fatty liver (15.4%), thyroid disorders (11.2%), hypertension (8.8%), and diabetes (4.9%) were the most prevalent NCDs. A large proportion of the population had some degree of anxiety (64.2%). Low physical activity (13 ± 22.4 min per day), high calorie intake (3079 ± 1252), and poor pulse-wave velocity (7.2 ± 1.6 m/s) highlight the need for strategies to improve lifestyle behaviors. CONCLUSION: The PERSIAN Organizational Cohort study in Mashhad University of Medical Sciences is the first organizational cohort study in a metropolitan city of Iran aiming to provide a large data repository on the prevalence and risk factors of the NCDs in a developing country for future national and international research cooperation.


Asunto(s)
Enfermedades no Transmisibles , Adulto , Anciano , Ciudades , Estudios de Cohortes , Femenino , Humanos , Irán , Masculino , Persona de Mediana Edad , Enfermedades no Transmisibles/epidemiología , Estudios Prospectivos , Análisis de la Onda del Pulso , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...