Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Surg ; 67(2): 637-644.e30, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29389426

RESUMEN

OBJECTIVE: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible. METHODS: Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. RESULTS: The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Asunto(s)
Prótesis Vascular , Aprobación de Recursos/normas , Procedimientos Endovasculares/instrumentación , Enfermedad Arterial Periférica/terapia , Sistema de Registros/normas , Stents , United States Food and Drug Administration/normas , Procedimientos Quirúrgicos Vasculares/instrumentación , Minería de Datos/normas , Registros Electrónicos de Salud/normas , Procedimientos Endovasculares/efectos adversos , Humanos , Cooperación Internacional , Informática Médica/normas , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/fisiopatología , Vigilancia de Productos Comercializados/normas , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto/normas , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos/epidemiología , Procedimientos Quirúrgicos Vasculares/efectos adversos , Flujo de Trabajo
2.
Circ J ; 82(2): 316-322, 2018 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-29367497

RESUMEN

BACKGROUND: The current state of evaluating patients with peripheral artery disease and more specifically of evaluating medical devices used for peripheral vascular intervention (PVI) remains challenging because of the heterogeneity of the disease process, the multiple physician specialties that perform PVI, the multitude of devices available to treat peripheral artery disease, and the lack of consensus about the best treatment approaches. Because PVI core data elements are not standardized across clinical care, clinical trials, and registries, aggregation of data across different data sources and physician specialties is currently not feasible.Methods and Results:Under the auspices of the U.S. Food and Drug Administration's Medical Device Epidemiology Network initiative-and its PASSION (Predictable and Sustainable Implementation of the National Registries) program, in conjunction with other efforts to align clinical data standards-the Registry Assessment of Peripheral Interventional Devices (RAPID) workgroup was convened. RAPID is a collaborative, multidisciplinary effort to develop a consensus lexicon and to promote interoperability across clinical care, clinical trials, and national and international registries of PVI. The current manuscript presents the initial work from RAPID to standardize clinical data elements and definitions, to establish a framework within electronic health records and health information technology procedural reporting systems, and to implement an informatics-based approach to promote the conduct of pragmatic clinical trials and registry efforts in PVI. CONCLUSIONS: Ultimately, we hope this work will facilitate and improve device evaluation and surveillance for patients, clinicians, health outcomes researchers, industry, policymakers, and regulators.


Asunto(s)
Equipos y Suministros/normas , Enfermedad Arterial Periférica , Sistema de Registros/normas , Monitoreo Epidemiológico , Humanos , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/terapia , Estándares de Referencia
3.
J Vasc Surg ; 54(2): 394-401, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21658885

RESUMEN

BACKGROUND: A novel self-expanding drug-eluting stent was designed to slowly release everolimus to prevent restenosis following peripheral arterial intervention. The purpose of the first-in-human Superficial Femoral Artery Treatment with Drug-Eluting Stents (STRIDES) trial was to evaluate the safety and efficacy of this device for the treatment of symptomatic superficial femoral and proximal popliteal arterial occlusive disease. METHODS AND RESULTS: One hundred four patients were enrolled at 11 European investigative centers in a prospective, nonrandomized, single-arm trial. The patients had severe symptomatic vascular disease, including a significant proportion of patients with critical limb ischemia (17%), diabetes (39%), and single-vessel outflow (26%). The mean lesion length was 9.0 ± 4.3 cm. Ninety-nine percent of patients were available for 12-month follow-up, including duplex imaging in 90% and arteriography in 83%. Clinical improvement, defined as a sustained decrease in Rutherford-Becker clinical category, was achieved in 80% of patients. Primary patency (freedom from ≥50% in-stent restenosis) was 94 ± 2.3% and 68 ± 4.6% at 6 and 12 months, respectively. Plain radiographic examination of 122 implanted devices at 12 months revealed no evidence for stent fracture. CONCLUSIONS: The everolimus-eluting self-expanding nitinol stent can be successfully implanted in patients with severe peripheral arterial disease with favorable outcomes and clinical improvements observed in the majority of patients.


Asunto(s)
Angioplastia/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Arteria Femoral , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Sirolimus/análogos & derivados , Anciano , Angioplastia/efectos adversos , Índice Tobillo Braquial , Constricción Patológica , Europa (Continente) , Everolimus , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Estimación de Kaplan-Meier , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Prospectivos , Diseño de Prótesis , Radiografía , Índice de Severidad de la Enfermedad , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
4.
Am J Cardiol ; 99(10): 1403-8, 2007 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-17493469

RESUMEN

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/uso terapéutico , Estenosis Coronaria/terapia , Fosforilcolina/uso terapéutico , Sirolimus/análogos & derivados , Stents , Anciano , Implantación de Prótesis Vascular , Angiografía Coronaria , Circulación Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Proyectos de Investigación , Sirolimus/química , Sirolimus/farmacología , Sirolimus/uso terapéutico , Resultado del Tratamiento , Túnica Íntima/diagnóstico por imagen , Túnica Íntima/fisiopatología , Ultrasonografía Intervencional
5.
Am. j. cardiol ; 99(10): 1403-1408, May 2007. ilus
Artículo en Inglés | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1059491

RESUMEN

The ZoMaxx Coronary Stent System elutes the antiproliferative agent zotarolimus via a biocompatible phosphorylcholine polymer loaded onto a novel, thin, stainless steel stent platform containing an 0.0007-inch inner layer of tantalum that enhances fluoroscopic radiopacity. The objective of this single-arm prospective clinical trial was to assess the safety and performance of the ZoMaxx stent for the treatment of coronary artery stenosis. Forty consecutive patients with ischemic coronary occlusive disease due to single de novo obstructive lesions of native coronary arteries were treated with 3 x 18 mm ZoMaxx stents at the Dante Pazzanese de Cardiologie in Saõ Paulo, Brazil, between April and July 2005. Independent core laboratories analyzed quantitative coronary angiography and intravascular ultrasound results immediately after stent implantation, and after 4 months. The lesion, procedure, and device-deployment success rates were all 100% (40 of 40). There were no major adverse cardiac events during the study. Follow-up quantitative coronary angiography at 4 months revealed in-stent and in-segment late lumen losses of 0.20 +/- 0.35 and 0.17 +/- 0.35 mm, respectively. Follow-up intravascular ultrasound at 4 months revealed 6.5 +/- 6.2% neointimal volume obstruction. There were no instances of late acquired stent incomplete apposition or stent thrombosis. In conclusion, the ZoMaxx Coronary Stent can be safely implanted for the treatment of de novo coronary artery stenosis. The inhibition of neointima formation as measured by follow-up angiography and IVUS after 4 months suggests therapeutic potential for the reduction of restenosis.


Asunto(s)
Angiografía Coronaria , Angioplastia Coronaria con Balón/instrumentación , Cardiotónicos/uso terapéutico , Circulación Coronaria , Diseño de Prótesis , Fosforilcolina/uso terapéutico , Implantación de Prótesis Vascular , Diseño de Investigaciones Epidemiológicas , Reestenosis Coronaria , Reestenosis Coronaria/etiología , Sirolimus/análogos & derivados , Sirolimus/farmacología , Sirolimus/química , Sirolimus/uso terapéutico , Stents , Túnica Íntima , Túnica Íntima/fisiopatología
SELECCIÓN DE REFERENCIAS