Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
JACC Clin Electrophysiol ; 10(7 Pt 1): 1455-1464, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38795101

RESUMEN

BACKGROUND: Patients with nonischemic dilated cardiomyopathy (DCM), severe left ventricular (LV) dysfunction, and complete left bundle branch block benefit from cardiac resynchronization therapy (CRT). However, a large heterogeneity of response to CRT is described. Several predictors of response to CRT have been identified, but the role of the underlying genetic background is still poorly explored. OBJECTIVES: In the present study, the authors sought to define differences in LV remodeling and outcome prediction after CRT when stratifying patients according to the presence or absence of DCM-causing genetic background. METHODS: From our center, 74 patients with DCM subjected to CRT and available genetic testing were retrospectively enrolled. Carriers of causative monogenic variants in validated DCM-causing genes, and/or with documented family history of DCM, were classified as affected by genetically determined disease (GEN+DCM) (n = 25). Alternatively, by idiopathic dilated cardiomyopathy (idDCM) (n = 49). The primary outcome was long-term LV remodeling and prevalence of super response to CRT (evaluated at 24-48 months after CRT); the secondary outcome was heart failure-related death/heart transplant/LV assist device. RESULTS: GEN+DCM and idDCM patients were homogeneous at baseline with the exception of QRS duration, longer in idDCM. The median follow-up was 55 months. Long-term LV reverse remodeling and the prevalence of super response were significantly higher in the idDCM group (27% in idDCM vs 5% in GEN+DCM; P = 0.025). The heart failure-related death/heart transplant/LV assist device outcome occurred more frequently in patients with GEN+DCM (53% vs 24% in idDCM; P = 0.028). CONCLUSIONS: Genotyping contributes to the risk stratification of patients with DCM undergoing CRT implantation in terms of LV remodeling and outcomes.


Asunto(s)
Terapia de Resincronización Cardíaca , Cardiomiopatía Dilatada , Remodelación Ventricular , Humanos , Femenino , Masculino , Cardiomiopatía Dilatada/genética , Cardiomiopatía Dilatada/terapia , Cardiomiopatía Dilatada/fisiopatología , Persona de Mediana Edad , Estudios Retrospectivos , Remodelación Ventricular/genética , Remodelación Ventricular/fisiología , Anciano , Resultado del Tratamiento , Insuficiencia Cardíaca/genética , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/fisiopatología , Adulto , Disfunción Ventricular Izquierda/genética , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Bloqueo de Rama/genética , Bloqueo de Rama/terapia , Bloqueo de Rama/fisiopatología
2.
J Cardiovasc Dev Dis ; 11(2)2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38392277

RESUMEN

Myotonic dystrophy is a hereditary disorder with systemic involvement. The Italian Neuro-Cardiology Network-"Rete delle Neurocardiologie" (INCN-RNC) is a unique collaborative experience involving neurology units combined with cardio-arrhythmology units. The INCN facilitates the creation of integrated neuro-cardiac teams in Neuromuscular Disease Centers for the management of cardiovascular involvement in the treatment of myotonic dystrophy type 1 (MD1).

3.
Intern Emerg Med ; 19(1): 107-114, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37934343

RESUMEN

At the beginning of the COVID-19 emergency, non-urgent surgical procedures had to be deferred, but also emergencies were reduced. To assess the global trend of pacemaker (PM) and implantable cardiac-defibrillator (ICD) procedures performed in Italy before, during, and after the first COVID-19 emergency, all the Italian hospital discharge records related to PM/ICD procedures performed between 2012 and 2021, sent to the National Institute of Health, were reviewed. Compared to 2019, in 2020, there was a reduction of first PM implants (52,216 to 43,962, -16%; p < 0.01), but not replacements (16,591 to 17,331, + 4%; p = 0.16). In particular, in April 2020, there was a drop of first implants (- 53,4% vs the average value of April 2018 and April 2019; p < 0.01), while the reduction of replacements was less evident (-32.6%; p = NS). In 2021, PM procedures increased to values similar to the pre-pandemic period. A reduction of ICD procedures was observed in 2020 (22,355, -7% toward 2019), mainly in April 2020 (- 46% vs April 2018/April 2019; p = 0.03). In 2021, the rate of ICD procedures increased (+ 14% toward 2020). A non-significant reduction of "urgent" procedures (complete atrioventricular block for PM and ventricular fibrillation for ICD), even in April 2020, was observed. In 2020, there was a reduction of first PM implants and ICDs, offset by increased activity in 2021. No decrease in PM replacements was observed, and the drop in "urgent" PM and ICD procedures was not statistically significant.


Asunto(s)
COVID-19 , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Pandemias , Sistema de Registros , COVID-19/epidemiología , Italia/epidemiología
4.
J Cardiovasc Med (Hagerstown) ; 24(12): 871-879, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37851355

RESUMEN

BACKGROUND: There are limited data on implantable-cardioverter-defibrillator (ICD) implantation after ST-elevation myocardial infarction (STEMI) treated with primary percutaneous coronary intervention (pPCI). Therefore, we evaluated when and how frequently an ICD is implanted after pPCI, the rate of appropriate ICD interventions, and predictors of ICD implantation. METHODS: We analyzed STEMI patients treated with pPCI at the University Hospital of Trieste, Italy, between January 2010 and December 2019. We cross-matched patients' data with those present in the Trieste ICD registry. RESULTS: Among 1805 consecutive patients treated with pPCI, 3.6% underwent ICD implantation during a median follow-up of 6.7 [interquartile range (IQR) 4.3-9.2] years. At 12 months, the mean number of ICD implantations was 2.3/100 patients [95% confidence interval (95% CI) 1.7-3.1] and remained stable over time (at 24 months: 2.5/100 patients, 95% CI 2.0-3.5 and at 36 months: 2.6/100 patients, 95% CI 2.3-3.8); 83.1% of ICDs were implanted for primary prevention, and more than half (55%) were implanted in patients with ejection fraction more than 35% at the moment of STEMI discharge. The rate of appropriate ICD interventions was 16.9% at a median follow-up of 5.7 years (IQR 3.3-8.3 years) after ICD implantation. At 12 months, the mean number of appropriate ICD interventions was 5/100 patients and 7/100 patients after 24 months. In patients with ejection fraction more than 35% at STEMI discharge (median ejection fraction 43%; IQR 40-48), independent predictors of ICD implantation were male sex, anterior STEMI and troponin peak more than 100 000 ng/dl. CONCLUSION: The rate of ICD implantations after pPCI is low; however, the rate of appropriate ICD interventions is high. A relevant subgroup of patients received ICD implantations at follow-up despite a nonsevere ejection fraction at discharge after STEMI. Among these patients, those with high troponin release deserve strict follow-up and full optimal medical treatment.


Asunto(s)
Desfibriladores Implantables , Infarto del Miocardio , Infarto del Miocardio con Elevación del ST , Humanos , Masculino , Femenino , Infarto del Miocardio con Elevación del ST/diagnóstico por imagen , Infarto del Miocardio con Elevación del ST/terapia , Infarto del Miocardio/terapia , Sistema de Registros , Troponina , Resultado del Tratamiento
5.
Sci Rep ; 13(1): 14695, 2023 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-37679479

RESUMEN

Seismic reflection (2D/3D), borehole and bathymetric data are used to recognize a new gravitational complex in the Gulf of Squillace, Southern Italy, named the Squillace Complex. The complex has a NE-striking headwall connected to a basal detachment formed between Messinian evaporites and Tortonian shales. Its sense of movement changes to a W-E direction in the toe region. In plan view, the Squillace Complex is marked by the presence of sinuous and continuous seafloor scarps, just a few kilometers offshore, over an elongated morphological high. Seismic-well ties reveal that the complex was initiated in the Zanclean (~ 4 Ma) and continued its movement into the Gelasian (~ 2.1 Ma) at an average rate of 1.9 mm/year. Movement slowed down in the Calabrian (middle Pleistocene) and continued until the present day at a lower rate of 0.1 mm/year. Gravitational collapse of the Squillace Complex correlates with discrete contractional/transpressional events affecting the Calabrian region, which caused basin shortening and the temporary arrest of Calabrian Arc migration. These episodes resulted in tectonic uplift in the study area after 0.45 Ma (Late Pleistocene). Conversely, the complex's slower movement recorded since the Calabrian (middle Pleistocene) is associated with slab rollback of the Ionian plate under the Calabrian Arc.

6.
G Ital Cardiol (Rome) ; 24(10): 844-848, 2023 Oct.
Artículo en Italiano | MEDLINE | ID: mdl-37767838

RESUMEN

BACKGROUND: The Pacemaker (PM) and Implantable Cardioverter-Defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the voluntary Italian collaborating centers. METHODS: For the year 2022 main data about national PM and ICD implantation activity were obtained on the basis of European Cards and subsequently analyzed to create a standard report. RESULTS: PM Registry: data about 17 800 PM implantations were collected (14 191 first implants and 3609 replacements). The number of collaborating centers was 152. Median age of treated patients was 81 years (75 quartile I; 86 quartile III). Main ECG indications included atrioventricular conduction disorders in 46.0% of first PM implants, sick sinus syndrome in 17.7%, atrial fibrillation plus bradycardia in 7.7%, other unspecified ECG and electrophysiological abnormalities in 43.0%. For first PM implants, pacing in DDDR mode was reported in 42.2%, followed by DDD mode (20.6%), VVIR mode (25.1%), VVI mode (11.1%) and finally VDD-VDDR (5.1%). Median value of longevity of explanted PMs was 8.3 years. ICD Registry: data about 5210 ICD implantations were obtained (3656 first implants and 1554 replacements). The number of collaborating centers was 301. Median age of treated patients was 72 years (63 quartile I; 79 quartile III). Primary prevention indication was reported in 72.4% of first implants, secondary prevention in 27.6% (cardiac arrest in 4.6% of records). A single-chamber ICD was used in 30.3% of first implants, dual-chamber ICD in 30.0% and biventricular ICD in 39.7%. Median value of longevity of explanted ICDs was 7.0 years. CONCLUSIONS: In the calendar year 2022, the Italian PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The ICD Registry documented a large use of prophylactic and biventricular ICDs, reflecting a favorable adherence in clinical practice to trials and guidelines. The ICD longevity and the number of recalls demonstrated a favorable trend.

7.
J Cardiovasc Med (Hagerstown) ; 24(9): 625-630, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37605954

RESUMEN

AIMS: In Italy, 12-month survival in the general population between 90 and 94 years old is 26%. In very old patients, the benefit of pacemaker implantation in terms of quality and duration of life is unclear. The aim of our study was to analyse clinical characteristics, outcome and factors associated with survival in patients at least 90 years old at the time of the first pacemaker implant. METHODS: Clinical parameters, device characteristics, survival and predictors of outcome in patients at least 90 years old treated with a pacemaker in our centre in 2019-2020 were evaluated. RESULTS: Among the 554 patients undergoing pacemaker implantation in our centre during the study interval, 69 (12%) were at least 90 years old; a complete/advanced atrioventricular block was present in 65%. A cardiological comorbidity (excluding atrial fibrillation) was present in 22 patients (32%). Oncological, pulmonary and neurological comorbidities were present in 12 (17%), 19 (28%) and 32 (46%), respectively. Renal impairment was present in 25 patients (36%). After pacemaker implantation, a pneumothorax developed in two patients and lead dislodgment in one. During follow-up (median 17 months, interquartile range: 13-24), 32 patients died (46%), with a 12-month mortality probability of 24.6%. At multivariate analysis, the presence of oncological (hazard ratio (HR) 5.31; P < 0.001) and neurological (HR 6.44; P < 0.001) comorbidities was associated with mortality. Truncating the outcome at 6 months, renal impairment (HR 8.01; P = 0.003), anticoagulant therapy (HR 8.14; P = 0.003), oncological comorbidities (HR 14.1; P < 0.001) and left ventricular function (5% increase of left ventricular ejection fraction: HR 0.66; P < 0.001) were significantly associated with outcome. CONCLUSION: At our centre, patients at least 90 years old underwent pacemaker implantation mainly for advanced atrioventricular block. One-year survival was excellent, even better than expected in the general population.


Asunto(s)
Fibrilación Atrial , Bloqueo Atrioventricular , Cardiología , Marcapaso Artificial , Humanos , Anciano de 80 o más Años , Bloqueo Atrioventricular/terapia , Italia/epidemiología , Marcapaso Artificial/efectos adversos
8.
Eur Heart J Suppl ; 25(Suppl C): C137-C143, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125318

RESUMEN

Dilated cardiomyopathy is a primitive heart muscle condition, characterized by structural and functional abnormalities, in the absence of a specific cause sufficient to determine the disease. It is, though, an 'umbrella' term that describes the final common pathway of different pathogenic processes and gene-environment interactions. Performing an accurate diagnostic workup and appropriate characterization of the patient has a direct impact on the patient's outcome. The physician should adapt a multiparametric approach, including a careful anamnesis and physical examination and integrating imaging data and genetic testing. Aetiological characterization should be pursued, and appropriate arrhythmic risk stratification should be performed. Evaluations should be repeated thoroughly at follow-up, as the disease is dynamical over time and individual risk might evolve. The goal is an all-around characterization of the patient, a personalized medicine approach, in order to establish a diagnosis and therapy tailored for the individual patient.

9.
Eur J Intern Med ; 115: 1-9, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37076404

RESUMEN

In this review we focus on heart failure (HF) which, as known, is associated with a substantial risk of hospitalizations and adverse cardiovascular outcomes, including death. In recent years, systems to monitor cardiac function and patient parameters have been developed with the aim to detect subclinical pathophysiological changes that precede worsening HF. Several patient-specific parameters can be remotely monitored through cardiac implantable electronic devices (CIED) and can be combined in multiparametric scores predicting patients' risk of worsening HF with good sensitivity and moderate specificity. Early patient management at the time of pre-clinical alerts remotely transmitted by CIEDs to physicians might prevent hospitalizations. However, it is not clear yet which is the best diagnostic pathway for HF patients after a CIED alert, which kind of medications should be changed or escalated, and in which case in-hospital visits or in-hospital admissions are required. Finally, the specific role of healthcare professionals involved in HF patient management under remote monitoring is still matter of definition. We analyzed recent data on multiparametric monitoring of patients with HF through CIEDs. We provided practical insights on how to timely manage CIED alarms with the aim to prevent worsening HF. We also discussed the role of biomarkers and thoracic echo in this context, and potential organizational models including multidisciplinary teams for remote care of HF patients with CIEDs.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/terapia
10.
G Ital Cardiol (Rome) ; 24(3): 245-249, 2023 Mar.
Artículo en Italiano | MEDLINE | ID: mdl-36853163

RESUMEN

BACKGROUND: The Pacemaker (PM) and Implantable Cardioverter-Defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the voluntary Italian collaborating centers. METHODS: For the year 2021 main data about national PM and ICD implantation activity were obtained on the basis of European Cards and subsequently analyzed to create a standard report. RESULTS: PM Registry: data about 18 631 PM implantations were collected (15879 first implants and 2752 replacements). The number of collaborating centers was 121. Median age of treated patients was 82 years (76 quartile I; 87 quartile III). Main ECG indications included atrioventricular conduction disorders in 26.8% of first PM implants, sick sinus syndrome in 12.2%, atrial fibrillation plus bradycardia in 9.6%, other unspecified ECG and electrophysiological abnormalities in 43.0%. For first PM implants, pacing in DDDR mode was reported in 46.5%, followed by DDD mode (20.6%), VVIR mode (15.0%), VVI mode (9.0%) and finally VDD-VDDR (5.8%). Median value of longevity of explanted PMs was 8.9 years. ICD Registry: data about 6878 ICD implantations were obtained (4708 first implants and 2170 replacements). The number of collaborating centers was 345. Median age of treated patients was 72 years (70 quartile I; 75 quartile III). Primary prevention indication was reported in 86.3% of first implants, secondary prevention in 13.7% (cardiac arrest in 4.4% of records). A single-chamber ICD was used in 32.1% of first implants, dual-chamber ICD in 30.3% and biventricular ICD in 37.6%. Median value of longevity of explanted ICDs was 6.9 years. CONCLUSIONS: In the calendar year 2021, the Italian PM Registry showed stable electrocardiographic and symptom indications, with an important prevalence of dual-chamber pacing. The ICD Registry documented a large use of prophylactic and biventricular ICDs, reflecting a favorable adherence in the clinical practice to trials and guidelines. The ICD longevity and the number of recalls demonstrated a favorable trend. In order to increase and optimize the cooperation of Italian PM and ICD implanting centers, the online data entry (https://www.aiac.it/riprid) should be adopted at large scale.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Marcapaso Artificial , Humanos , Anciano de 80 o más Años , Anciano , Sistema de Registros , Bradicardia
12.
J Cardiovasc Electrophysiol ; 34(4): 947-956, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36709469

RESUMEN

INTRODUCTION: Thoracic impedance (TI) drops measured by implantable cardioverter-defibrillators (ICDs) have been reported to correlate with ventricular tachycardia/fibrillation (VT/VF). The aim of our study was to assess the temporal association of decreasing TI trends with VT/VF episodes through a longitudinal analysis of daily remote monitoring data from ICDs and cardiac resynchronization therapy defibrillators (CRT-Ds). METHODS AND RESULTS: Retrospective data from 2384 patients were randomized 1:1 into a derivation or validation cohort. The TI decrease rate was defined as the percentage of rolling weeks with a continuously decreasing TI trend. The derivation cohort was used to determine a TI decrease rate threshold for a ≥99% specificity of arrhythmia prediction. The associated risk of VT/VF episodes was estimated in the validation cohort by dividing the available follow-up into 60-day assessment intervals. Analyses were performed separately for 1354 ICD and 1030 CRT-D patients. During a median follow-up of 2.0 years, 727 patients (30.4%) experienced 3298 confirmed VT/VF episodes. In the ICD group, a TI decrease rate of >60% was associated with a higher risk of VT/VF episode in a 60-day assessment interval (stratified hazard ratio, 1.42; 95% confidence interval (CI), 1.05-1.92; p = .023). The TI decrease preceded (40.8%) or followed (59.2%) the VT/VF episodes. In the CRT-D group, no association between TI decrease and VT/VF episodes was observed (p = .84). CONCLUSION: In our longitudinal analysis, TI decrease was associated with VT/VF episodes only in ICD patients. Preventive interventions may be difficult since episodes can occur before or after TI decrease.


Asunto(s)
Arritmias Cardíacas , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/terapia , Impedancia Eléctrica , Estudios Retrospectivos , Fibrilación Ventricular , Desfibriladores Implantables
13.
Eur J Clin Invest ; 53(1): e13862, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36004486

RESUMEN

BACKGROUND: The number of patients with cardiac implantable electronic devices (CIEDs) undergoing radiotherapy (RT) for cancer treatment is growing. At present, prevalence and predictors of RT-induced CIEDs malfunctions are not defined. METHODS: Systematic review and meta-analysis conducted following the PRISMA recommendations. PubMed, Scopus and Google Scholar were searched from inception to 31/01/2022 for studies reporting RT-induced malfunctions in CIEDs patients. Aim was to assess the prevalence of RT-induced CIEDs malfunctions and identify potential predictors. RESULTS: Thirty-two out of 3962 records matched the inclusion criteria and were included in the meta-analysis. A total of 135 CIEDs malfunctions were detected among 3121 patients (6.6%, 95% confidence interval [CI]: 5.1%-8.4%). The pooled prevalence increased moving from pacemaker (PM) to implantable cardioverter defibrillator (ICD), and cardiac resynchronization therapy and defibrillator (CRT-D) groups (4.1%, 95% CI: 2.9-5.8; 8.2% 95% CI: 5.9-11.3; and 19.8%, 95% CI: 11.4-32.2 respectively). A higher risk ratio (RR) of malfunctions was found when neutron-producing energies were used as compared to non-neutron-producing energies (RR 9.98, 95% CI: 5.09-19.60) and in patients with ICD/CRT-D as compared to patients with PM/CRT-P (RR 2.07, 95% CI: 1.40-3.06). On the contrary, no association was found between maximal radiation dose at CIED >2 Gy and CIEDs malfunctions (RR 0.93; 95% CI: 0.31-2.76). CONCLUSIONS: Radiotherapy related CIEDs malfunction had a prevalence ranging from 4% to 20%. The use of neutron-producing energies and more complex devices (ICD/CRT-D) were associated with higher risk of device malfunction, while the radiation dose at CIED did not significantly impact on the risk unless higher doses (>10 Gy) were used.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos
14.
G Ital Cardiol (Rome) ; 23(11): 827-835, 2022 Nov.
Artículo en Italiano | MEDLINE | ID: mdl-36300386

RESUMEN

With the regional law n. 26 of December 30, 2020, the Friuli Venezia Giulia Region wanted to promote the establishment of the Regional Register of Sudden Cardiac Death, with the aim of favoring the study of all those deaths that occurred suddenly and unexpectedly under the age of 50 years in which it is not possible to trace the cause of death with certainty. Such dramatic events, difficult to quantify considering the complexity of data collection, are often accepted with resignation without any further investigation of the possible causes. The Regional Register of Sudden Cardiac Deaths of Friuli Venezia Giulia was born from this premise and from the awareness of the importance of going back with a rigorous scientific methodology and through a multidisciplinary approach, to the diagnosis of hereditary heart diseases which, when determined, allow the enrollment of relatives in a cardiological screening process and, therefore, primary prevention of potentially fatal events. The authors describe the operating procedures feeding the Regional Register and present the results of the first year of activity on 26 cases.


Asunto(s)
Muerte Súbita Cardíaca , Humanos , Persona de Mediana Edad , Sistema de Registros , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Italia/epidemiología
15.
G Ital Cardiol (Rome) ; 23(5): 328-335, 2022 May.
Artículo en Italiano | MEDLINE | ID: mdl-35578956

RESUMEN

Implantation of pacemakers and cardiac defibrillators is a life-saving treatment but can put our patients at risk of infections, increasing morbidity and mortality and prolonging hospitalization with a significant financial healthcare burden. A preventive strategy is crucial but, while several strategies such as administration of intravenous antibiotic therapy before implantation are well recognized, other uncertainties remain. The main gaps regard the use of periprocedural measures, including antibacterial envelope to prevent device infection, the appropriate management of antithrombotic therapy before and after device implantation and timing of device reimplantation. To address these issues, some important randomized clinical trials and a European Heart Rhythm Association consensus document have recently been published. The aim of this article is to review current knowledge on the management of infections in patients with cardiac implantable electronic devices to help not only electrophysiologists, but also physicians in their daily practice.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Antibacterianos/uso terapéutico , Consenso , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/prevención & control
16.
G Ital Cardiol (Rome) ; 23(5): 340-378, 2022 May.
Artículo en Italiano | MEDLINE | ID: mdl-35578958

RESUMEN

Heart failure is a complex clinical syndrome with a severe prognosis, despite therapeutic progress. The management of the advanced stages of the syndrome is particularly complex in patients who are referred to palliative care as well as in those who are candidates for cardiac replacement therapy. For the latter group, a prompt recognition of the transition to the advanced stage as well as an early referral to the centers for cardiac replacement therapy are essential elements to ensure that patients follow the most appropriate diagnostic-therapeutic pathway. The aim of this document is to focus on the main diagnostic and therapeutic aspects related to the advanced stages of heart failure and, in particular, on the management of patients who are candidates for cardiac replacement therapy.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Cardiotónicos/uso terapéutico , Vías Clínicas , Humanos , Cuidados Paliativos
17.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35499267

RESUMEN

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Asunto(s)
Fibrilación Atrial , Desfibriladores Implantables , Insuficiencia Cardíaca , Síndromes de la Apnea del Sueño , Algoritmos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Insuficiencia Cardíaca/complicaciones , Humanos , Síndromes de la Apnea del Sueño/complicaciones , Síndromes de la Apnea del Sueño/diagnóstico , Síndromes de la Apnea del Sueño/terapia
18.
G Ital Cardiol (Rome) ; 23(4): 309-313, 2022 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-35343483

RESUMEN

BACKGROUND: The Pacemaker (PM) and Implantable Cardioverter-Defibrillator (ICD) Registry of the Italian Association of Arrhythmology and Cardiac Pacing (AIAC) collects information about demographics, clinical characteristics, main indications for PM/ICD therapy and device types from the Italian collaborating centers. METHODS: For the year 2020, the main data about national PM and ICD implantation activity were obtained on the basis of European Cards and subsequently analyzed to create a standard report. RESULTS: PM Registry: data about 22 080 PM implantations were collected (18 027 first implants and 3803 replacements). The number of collaborating centers was 142. Median age of treated patients was 82 years (75 quartile I; 87 quartile III). ECG indications included atrioventricular conduction disorders in 31.0% of first PM implants, sick sinus syndrome in 13.8%, atrial fibrillation plus bradycardia in 9.9%, other unspecified ECG and electrophysiological abnormalities in 36.6%. Use of single-chamber PMs was reported in 29.0% of first implants, of dual-chamber PMs in 68.2%, of PM with cardiac resynchronization therapy (CRT) in 2.7%. ICD Registry: data about 11 931 ICD implantations were obtained (8266 first implants and 3665 replacements). The number of collaborating centers was 330. Median age of treated patients was 72 years [63 quartile I; 79 quartile III]. Primary prevention indication was reported in 85.0% of first implants, secondary prevention in 15.0% (cardiac arrest in 4.2%). A single-chamber ICD was used in 30.2% of first implants, dual-chamber ICD in 31.2% and biventricular ICD in 38.6%. CONCLUSIONS: In the calendar year 2020, the Italian PM Registry showed stable ECG and symptom indications, with an important prevalence of dual-chamber pacing. The ICD Registry documented a large use of prophylactic and biventricular ICDs, reflecting a favorable adherence in clinical practice to trials and guidelines. The ICD longevity and the number of recalls demonstrated a favorable trend. In order to increase and optimize the cooperation of Italian PM and ICD implanting centers, the online data entry (https://www.aiac.it/riprid) should be adopted at large scale.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas , Humanos , Sistema de Registros
19.
Europace ; 24(2): 234-244, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-34392336

RESUMEN

AIMS: We developed and validated an algorithm for prediction of heart failure (HF) hospitalizations using remote monitoring (RM) data transmitted by implanted defibrillators. METHODS AND RESULTS: The SELENE HF study enrolled 918 patients (median age 69 years, 81% men, median ejection fraction 30%) with cardiac resynchronization therapy (44%), dual-chamber (38%), or single-chamber defibrillators with atrial diagnostics (18%). To develop a predictive algorithm, temporal trends of diurnal and nocturnal heart rates, ventricular extrasystoles, atrial tachyarrhythmia burden, heart rate variability, physical activity, and thoracic impedance obtained by daily automatic RM were combined with a baseline risk-stratifier (Seattle HF Model) into one index. The primary endpoint was the first post-implant adjudicated HF hospitalization. After a median follow-up of 22.5 months since enrolment, patients were randomly allocated to the algorithm derivation group (n = 457; 31 endpoints) or algorithm validation group (n = 461; 29 endpoints). In the derivation group, the index showed a C-statistics of 0.89 [95% confidence interval (CI): 0.83-0.95] with 2.73 odds ratio (CI 1.98-3.78) for first HF hospitalization per unitary increase of index value (P < 0.001). In the validation group, sensitivity of predicting primary endpoint was 65.5% (CI 45.7-82.1%), median alerting time 42 days (interquartile range 21-89), and false (or unexplained) alert rate 0.69 (CI 0.64-0.74) [or 0.63 (CI 0.58-0.68)] per patient-year. Without the baseline risk-stratifier, the sensitivity remained 65.5% and the false/unexplained alert rates increased by ≈10% to 0.76/0.71 per patient-year. CONCLUSION: With the developed algorithm, two-thirds of first post-implant HF hospitalizations could be predicted timely with only 0.7 false alerts per patient-year.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Anciano , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hospitalización , Humanos , Masculino , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA