Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Curr Med Imaging ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38693744

RESUMEN

INTRODUCTION: Angiomatoid fibrous histiocytoma (AFH) is a borderline tumor usually affecting the the children or young adults. 18F-Fluorodexoyglucose (FDG) positron emission tomography/computed tomography (PET/CT) investigations of pulmonary AFH are rare, and there are currently no reports of intense FDG uptake in AFH. CASE REPORT: We report an AFH that occurred in the lung of a 57-year-old woman. She presented with paroxysmal cough and occasional bloodshot sputum. 18FFDG PET/CT revealed a right parahilar nodule with intense FDG-avidity, middle lobe atelectasis, and several bilateral axillary lymph nodes with mild hypermetabolic activity. This patient underwent a right middle lobe lobectomy via video-assisted thoracoscopy. Histopathologically, the diagnosis was pulmonary AFH. She had an uneventful postoperative course, and the bilateral axillary lymph nodes regressed during postoperative follow-up. CONCLUSIONS: The clinical presentation and image findings of patients with primary pulmonary AFH may be potential diagnosis pitfalls. The diagnosis of lymph nodes or distant metastases should be approached with caution. To avoid misdiagnosis, biopsy with histological examination and immunohistochemichal staining should be performed as early as possible.

2.
Quant Imaging Med Surg ; 13(10): 6863-6875, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37869314

RESUMEN

Background: Magnetic resonance imaging (MRI) plays an important role in the diagnosis of leptomeningeal metastases (LM); however, some sub-centimeter lesions may be missed. Positron emission tomography/computed tomography (PET/CT) has a high sensitivity and may play a synergistic role with MRI in diagnosing spinal LM (SLM). We aimed to retrospectively evaluate the detection of SLM with 18F-fluorodeoxyglucose PET/CT (18F-FDG PET/CT) compared to that of whole spinal cord MRI in a single center. Methods: Patients with SLM who had undergone 18F-FDG PET/CT and MRI were enrolled. 18F-FDG PET/CT imaging findings were independently reviewed by 2 nuclear medicine physicians. 18F-FDG PET/CT findings of SLMs were described. A consistency test was conducted to assess the patient-based diagnostic results obtained by the 2 physicians. Patient-based sensitivity, accuracy, and specificity in diagnosing SLM between 18F-FDG PET/CT and MRI of the whole spinal cord were compared using the chi-square or Fisher's exact test. A P value of <0.05 was considered statistically significant. The receiver operating characteristic (ROC) curve was obtained to assess the diagnostic performance of maximum standardized uptake value (SUVmax) to diagnose SLM. Results: A total of 16 patients with SLM were included in this study from October 2010 to April 2022. The primary tumor involved the lungs, liver, ovaries, prostate, esophagus, and unknown primary site. The mean age of patients, including 13 males and 3 females, was 57.8±11.2 (range, 34-73) years. Of 16 patients with SLM, 10 had nodular diseases, 2 had linear diseases, and 4 had mixed diseases. The kappa value of the consistency test of the 2 radiologists' diagnostic results was 0.765. The patient-based sensitivity, specificity, and accuracy of 18F-FDG PET/CT in diagnosing SLM were 87.5%, 89.2%, and 88.7%, respectively and those of whole spinal cord MRI were 75.0%, 100.0%, and 92.5%, respectively. There were no significant differences in sensitivity, specificity, and accuracy between the 2 methods, with P values of 0.654, 0.115, and 0.506, respectively. However, more nodular diseases were observed on PET/CT. The area under the ROC curve (AUC) for the prediction of SLM by SUVmax was 0.907 [95% confidence interval (CI): 0.831-0.983]. When SUVmax ≥2.45, the Youden index was the largest, and the sensitivity and specificity were 89.3% and 75.7%, respectively. Conclusions: 18F-FDG PET/CT is a good choice of imaging modality for assessing SLM. In the diagnosis of SLMs, PET/CT and enhanced MRI can play a better synergistic role.

3.
Front Oncol ; 12: 1068055, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36530987

RESUMEN

Background: Synchronous multiple primary malignant neoplasms occurring at the same time (SMPMNS) are not currently uncommon in clinical oncological practice; however, the diagnostic performance of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) for SMPMNS needs further elucidation. Purpose: This study aimed to evaluate the application of 18F-FDG PET/CT in patients with SMPMNS. Materials and methods: The clinical and imaging data of 37 patients with SMPMNS who had undergone 18F-FDG PET/CT from October 2010 to December 2020 were retrospectively analyzed. The kappa consistency test was applied to evaluate the consistency of the diagnostic performance between PET/CT and conventional imaging (CI). The sensitivity, specificity, and accuracy of PET/CT and CI in the detection of metastatic lesions were compared. Results: This retrospective diagnostic study included 74 lesions identified in 37 patients with SMPMNS, with 94.6% of patients having double primary tumors. Of the incidences of SMPMNS, 18.9% occurred in the same organ system, with respiratory tumors being the most common type of neoplasm (43.2%) and the lung being the most common primary site (40.5%). The overall survival of SMPMNS patients without metastases was longer than that of those with metastases (χ 2 = 12.627, p = 0.000). The maximum standardized uptake value (SUVmax), the SUVmax ratio (larger SUVmax/smaller SUVmax), and the difference index of SUVmax (DISUVmax) [(larger SUVmax - smaller SUVmax)/larger SUVmax] of the primary lesions ranged from 0.9 to 41.7 (average = 12.3 ± 7.9), from 0.3 to 26.7 (average = 4.4 ± 6.9), and from 0.0% to 96.3% (average = 50.3% ± 29.3%), respectively. With regard to diagnostic accuracy, PET/CT and CI showed poor consistency (κ = 0.096, p = 0.173). For the diagnosis of primary lesions (diagnosed and misdiagnosed), PET/CT and CI also showed poor consistency (κ = 0.277, p = 0.000), but the diagnostic performance of PET/CT was better than that of CI. In the diagnosis of metastases, the patient-based sensitivity, specificity, and accuracy of PET/CT were 100.0%, 81.8%, and 89.2%, respectively, while those of CI were 73.3%, 100.0%, 89.2%, respectively. The sensitivity and specificity values were significantly different, with PET/CT having higher sensitivity (p = 0.02) and CI showing higher specificity (p = 0.02). Conclusions: 18F-FDG PET/CT improves the diagnostic performance for SMPMNS and is a good imaging modality for patients with SMPMNS.

4.
J Pharm Pharmacol ; 73(5): 641-652, 2021 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-33772289

RESUMEN

OBJECTIVES: The current study was focused on preparing curcumin (CUR) supersaturated self-nano-emulsion (PI-CUR-SNEDDS) using hydrophilic polymer and to study the influence of polymer precipitation inhibitor on the physicochemical and biopharmaceutical properties of the PI-CUR-SNEDDS. METHODS: PI-CUR-SNEDDS were prepared using hydrophilic polymer in order to maintain the supersaturation of CUR in nano-emulsion solution, artificial gastrointestinal fluid (AGF), and the precipitates formed, and characterised by in vitro dispersion tests, in vitro intestinal absorption and in vivo pharmacokinetic and compared with CUR-SNEDDS. KEY FINDINGS: PI-CUR-SNEDDS prepared with 2% hydroxypropyl methylcellulose 55-60 (HPMC55-60) as precipitation inhibitor (PI) significantly improved the viscosity, physical stability and CUR's equilibrium solubility of nanoemulsion. HPMC55-60 and CUR interact in AGF through intermolecular interactions, form hydrogen bonds, and produce amorphous precipitates. Compared with CUR-SNEDDS, the proportion of CUR in the hydrophilic phase increased by about 3-fold, and apparent permeability coefficient (Papp) in duodenum, jejunum, ileum, and colon increased by 2.30, 3.65, 1.54 and 2.08-fold, respectively, and the area under the plasma concentration-time curve0-12h of PI-CUR-SNEDDS also increased by 3.50-fold. CONCLUSIONS: Our results suggested that HPMC55-60 maintained the CUR supersaturation state by forming hydrogen bonds with CUR, increasing the solution's viscosity and drug solubilisation, thus improving the absorption and bioavailability of CUR.


Asunto(s)
Curcumina/administración & dosificación , Curcumina/farmacocinética , Sistemas de Liberación de Medicamentos/métodos , Administración Oral , Animales , Disponibilidad Biológica , Liberación de Fármacos , Emulsiones/química , Interacciones Hidrofóbicas e Hidrofílicas , Derivados de la Hipromelosa/administración & dosificación , Derivados de la Hipromelosa/farmacología , Absorción Intestinal , Tamaño de la Partícula , Polímeros/administración & dosificación , Polímeros/farmacología , Ratas Sprague-Dawley , Solubilidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...