Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Shanghai Kou Qiang Yi Xue ; 22(2): 160-3, 2013 Apr.
Artículo en Chino | MEDLINE | ID: mdl-23708028

RESUMEN

PURPOSE: To compare the cleanliness of root end preparations by using ultrasonic instrumentation and slow-speed handpiece. METHODS: Thirty-two mesial roots of the first mandibular molars with two canals and mature root apices were assigned randomly to 2 groups, each group had 16 teeth. The root-end preparations were made respectively using ultrasonic diamond tip Berutti and NiTi tip RE2 and slow-speed handpiece with No.2 round bur. Root end cavities were examined under scanning electron microscope for further evaluation of the superficial debris and smear layer of the root end preparations. SPSS 13.0 software package was used for Kruskal Wallis test. RESULTS: Ultrasonic preparation had significantly less superficial debris and smear layer than slow-speed handpiece preparation (P<0.05). CONCLUSIONS: Ultrasonic instrument creates cleaner surfaces for root end cavities than slow-speed handpiece preparation in posterior teeth root end preparation.


Asunto(s)
Capa de Barro Dentinario , Ultrasonido , Caries Dental , Humanos , Diente Molar , Preparación del Conducto Radicular
2.
Shanghai Kou Qiang Yi Xue ; 17(4): 351-5, 2008 Aug.
Artículo en Chino | MEDLINE | ID: mdl-18784872

RESUMEN

PURPOSE: To evaluate the effects of retrograde preparation between ultrasonic retrotips and traditional slow-speed handpiece. METHODS: 27 maxillary second bicuspid teeth with two canals and one isthmus were divided randomly into 3 groups with 9 in each. The root-end preparations were made respectively using ultrasonic diamond tip Berutti and NiTi tip RE2, ultrasonic #40K file and slow-speed handpiece with NO.2 round bur. The postoperative epoxy resin replicas were examined under scanning electron microscope for further evaluating the number and type of the micro-cracks, the quality of cavity margin. SPSS13.0 software package was used for Kruskal-Wallis test. RESULTS: The number of micro-crack of ultrasonic instruments were significantly less than that of slow-speed handpiece(P=0.002).The type of micro-cracks has no significant difference between the two techniques(P=0.657). On the quality of cavity margin, the slow-speed handpiece group had significant inferior to the ultrasonic #40K file group(P=0.039); there was no significantly difference between the ultrasonic Berutti and RE2 group and the slow-speed handpiece group (P=0.136); there was no significant difference between the two ultrasonic groups (P=0.637). CONCLUSION: Ultrasonic instrument is feasible in the root-end preparation.


Asunto(s)
Diente Premolar , Preparación del Conducto Radicular , Apicectomía , Diamante , Humanos , Microscopía Electrónica de Rastreo , Terapia por Ultrasonido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...