Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Knee ; 47: 53-62, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38244239

RESUMEN

BACKGROUND: Currently, in the field of total joint arthroplasty (TJA), there are no studies that have demonstrated the value of the sequential application of hydrogen peroxide, povidone-iodine, and physiological saline during the surgical procedure in decreasing postoperative infections in total knee arthroplasty (TKA), and in decreasing the incidence of periprosthetic joint infections (PJI) in particular. This study aimed to assess the efficacy of the sequential application of hydrogen peroxide, povidone-iodine, and physiological saline in reducing postoperative infections in TKA. METHODS: The study prospectively included 4743 patients, with Group A (2371, 49.9%) receiving sequential intraoperative application of hydrogen peroxide, povidone-iodine, and physiological saline irrigation of the incision, and Group B (2372, 50.1%) receiving intraoperative application of physiological saline irrigation of the incision only, to collect the patients' baseline data and clinical characteristics, and to statistically assess the incidence of superficial infections and the PJI during the follow up period to evaluate the clinical value of the study. RESULTS: The baseline levels of patients in Groups A and B were comparable. There were 132 (2.8%) lost visits during the study period. The incidence of superficial infections within 30 days after surgery was 0.22% in Group A and 1.17% in Group B, the difference between the two groups was statistically significant (P = 0.007). The incidence of PJI was 0.17% in Group A and 1.26% in Group B, the difference between the two groups was statistically significant (P = 0.0121). CONCLUSION: Sequential application of hydrogen peroxide, povidone-iodine, and physiological saline to irrigate incision in TKA can significantly reduce the incidence of postoperative superficial infections and PJI. The scientific and rational application of this therapy intraoperatively greatly reduces the incidence of PJI and postoperative superficial infections, which is of great benefit to the patient's prognosis.


Asunto(s)
Antiinfecciosos Locales , Artroplastia de Reemplazo de Rodilla , Peróxido de Hidrógeno , Povidona Yodada , Infecciones Relacionadas con Prótesis , Solución Salina , Infección de la Herida Quirúrgica , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Povidona Yodada/administración & dosificación , Povidona Yodada/uso terapéutico , Peróxido de Hidrógeno/administración & dosificación , Masculino , Femenino , Estudios Prospectivos , Antiinfecciosos Locales/administración & dosificación , Anciano , Persona de Mediana Edad , Infección de la Herida Quirúrgica/prevención & control , Infección de la Herida Quirúrgica/epidemiología , Infección de la Herida Quirúrgica/etiología , Infecciones Relacionadas con Prótesis/prevención & control , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/epidemiología , Solución Salina/administración & dosificación , Irrigación Terapéutica/métodos , Incidencia
2.
Talanta ; 106: 255-60, 2013 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-23598125

RESUMEN

The selective adsorption of single-stranded oligonucleotides (ssDNA) on gold nanoparticles (AuNPs) is well known for stabilizing the AuNPs against aggregation even at high salt concentrations. Our investigation shows that the non-crosslinking aggregation of arbitrary ssDNA-capped AuNPs occurs due to their interaction with the cationic polyamine, spermine (Spm), even without any addition of NaCl. The non-crosslinking aggregation mechanism is that the Spm, served as multivalent counterions, plays the dual roles of charge shielding and ion bridging among the ssDNA-capped AuNPs, which jointly result in the aggregation of the ssDNA-capped AuNPs. Therefore, a sensitive and highly selective colorimetric method for the detection of Spm was developed. To the best of our knowledge, it is the first successful case as to the efforts towards the development of optical assays for cationic polyamine, showing neither natural UV absorption nor fluorescence. Compared with the traditional methods of chromatography and capillary electrophoresis, the approach described here would provide a convenient alternative and new train of thought for the specific detection of Spm in both biological fluid and fermented products.


Asunto(s)
Colorimetría/métodos , ADN de Cadena Simple/química , Nanopartículas del Metal/química , Espermina/sangre , Espermina/orina , Precipitación Química , ADN de Cadena Simple/síntesis química , Oro/química , Humanos , Oligonucleótidos/síntesis química , Oligonucleótidos/química , Sensibilidad y Especificidad
3.
PLoS One ; 7(12): e50367, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-23251366

RESUMEN

A comparative research of the assembly of different porphyrin molecules on graphene oxide (GO) and reduced graphene oxide (RGO) was carried out, respectively. Despite the cationic porphyrin molecules can be assembled onto the surfaces of graphene sheets, including GO and RGO, to form complexes through electrostatic and π-π stacking interactions, the more obvious fluorescence quenching and the larger red-shift of the Soret band of porphyrin molecule in RGO-bound states were observed than those in GO-bound states, due to the difference of molecular flattening in degree. Further, more interesting finding was that the complexes formed between cationic porphyrin and GO, rather than RGO sheets, can facilitate the incorporation of iron (III) ions into the porphyrin moieties, due to the presence of the oxygen-contained groups at the basal plane of GO sheets served as auxiliary coordination units, which can high-efficiently obstruct the electron transfer from excited porphyrin to GO sheets and result in the occurrence of fluorescence restoration. Thus, a fluorescence sensing platform has been developed for iron (III) ions detection in this contribution by using the porphyrin/GO nanohybrids as an optical probe, and our present one exhibited rapid and sensitive responses and high selectivity toward iron (III) ions.


Asunto(s)
Grafito/metabolismo , Hierro/metabolismo , Porfirinas/metabolismo , Transporte de Electrón , Fluorescencia , Humanos
4.
Anal Chim Acta ; 706(1): 171-5, 2011 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-21995925

RESUMEN

Carbon nanotubes (CNTs) can efficiently quench the fluorescence of the adsorbed fluorophores and nonconvalently interact with soft single-stranded DNA (ssDNA). Upon disruption of CNTs-fluorescent oligonucleotides hybrid by nuclease S1, fluorescence turn-on was observed. Using this strategy, a platform based on fluorescence signal for monitoring the activity of nuclease with advantages of high sensitivity and commonality was established, and a linear relationship between initial cleavage reaction rate and nuclease S1 concentration is found in the range of 0.6-8.0 U mL(-1) with a detection limit of 0.08 U mL(-1). Furthermore, by taking pyrophosphate as an example, we use the assay to evaluate the prohibition effect on nuclease, and the extent of fluorescence recovery decreased linearly with increasing the concentration of pyrophosphate in the range of 0.2-1.4 mM, implying that the cleavage reaction by nuclease S1 was prohibited, and therefore this fluorescence assay can also be conveniently utilized for inhibitor screening of nuclease.


Asunto(s)
ADN de Cadena Simple/metabolismo , Inhibidores Enzimáticos/química , Nanotubos de Carbono/química , Endonucleasas Específicas del ADN y ARN con un Solo Filamento/metabolismo , Espectrometría de Fluorescencia , División del ADN , ADN de Cadena Simple/química , Difosfatos/química , Colorantes Fluorescentes/química , Cinética , Oligonucleótidos/síntesis química , Oligonucleótidos/metabolismo , Rodaminas/química , Endonucleasas Específicas del ADN y ARN con un Solo Filamento/antagonistas & inhibidores
5.
Chem Commun (Camb) ; 47(9): 2604-6, 2011 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-21234476

RESUMEN

A simple method for phosphate (Pi) detection is established by developing an off-on fluorescence probe of europium-adjusted carbon dots (CDs), which has been successfully applied to the detection of Pi in very complicated matrixes such as artificial wetlands system.


Asunto(s)
Carbono/química , Europio/química , Colorantes Fluorescentes/química , Fosfatos/análisis , Espectrometría de Fluorescencia/métodos , Microscopía de Fuerza Atómica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA