Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
BMC Med Imaging ; 24(1): 124, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38802736

RESUMEN

BACKGROUND: The prevalence of hypertensive heart disease (HHD) is high and there is currently no easy way to detect early HHD. Explore the application of radiomics using cardiac magnetic resonance (CMR) non-enhanced cine sequences in diagnosing HHD and latent cardiac changes caused by hypertension. METHODS: 132 patients who underwent CMR scanning were divided into groups: HHD (42), hypertension with normal cardiac structure and function (HWN) group (46), and normal control (NOR) group (44). Myocardial regions of the end-diastolic (ED) and end-systolic (ES) phases of the CMR short-axis cine sequence images were segmented into regions of interest (ROI). Three feature subsets (ED, ES, and ED combined with ES) were established after radiomic least absolute shrinkage and selection operator feature selection. Nine radiomic models were built using random forest (RF), support vector machine (SVM), and naive Bayes. Model performance was analyzed using receiver operating characteristic curves, and metrics like accuracy, area under the curve (AUC), precision, recall, and specificity. RESULTS: The feature subsets included first-order, shape, and texture features. SVM of ED combined with ES achieved the highest accuracy (0.833), with a macro-average AUC of 0.941. AUCs for HHD, HWN, and NOR identification were 0.967, 0.876, and 0.963, respectively. Precisions were 0.972, 0.740, and 0.826; recalls were 0.833, 0.804, and 0.863, respectively; and specificities were 0.989, 0.863, and 0.909, respectively. CONCLUSIONS: Radiomics technology using CMR non-enhanced cine sequences can detect early cardiac changes due to hypertension. It holds promise for future use in screening for latent cardiac damage in early HHD.


Asunto(s)
Diagnóstico Precoz , Hipertensión , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Imagen por Resonancia Cinemagnética/métodos , Persona de Mediana Edad , Hipertensión/diagnóstico por imagen , Hipertensión/complicaciones , Máquina de Vectores de Soporte , Cardiopatías/diagnóstico por imagen , Anciano , Adulto , Teorema de Bayes , Curva ROC , Interpretación de Imagen Asistida por Computador/métodos , Radiómica
2.
J Xray Sci Technol ; 2024 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-38217636

RESUMEN

PURPOSE: To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium. METHODS: Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)<  30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected. RESULTS: The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively. CONCLUSION: GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.

3.
J Xray Sci Technol ; 31(6): 1333-1340, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37840466

RESUMEN

OBJECTIVE: To explore the value of applying computed tomography (CT) radiomics based on different CT-enhanced phases to determine the immunotherapeutic efficacy of non-small cell lung cancer (NSCLC). METHODS: 106 patients with NSCLC who underwent immunotherapy are randomly divided into training (74) and validation (32) groups. CT-enhanced arterial and venous phase images of patients before treatment are collected. Region-of-interest (ROI) is segmented on the CT-enhanced images, and the radiomic features are extracted. One-way analysis of variance and least absolute shrinkage and selection operator (LASSO) are used to screen the optimal radiomics features and analyze the association between radiomics features and immunotherapy efficacy. The area under receiver-operated characteristic curves (AUC) along with the sensitivity and specificity are computed to evaluate diagnostic effectiveness. RESULTS: LASSO regression analysis screens and selects 6 and 8 optimal features in the arterial and venous phases images, respectively. Applying to the training group, AUCs based on CT-enhanced arterial and venous phase images are 0.867 (95% CI:0.82-0.94) and 0.880 (95% CI:0.86-0.91) with the sensitivities of 73.91% and 76.19%, and specificities of 66.67% and 72.19%, respectively, while in validation group, AUCs of the arterial and venous phase images are 0.732 (95% CI:0.71-0.78) and 0.832 (95% CI:0.78-0.91) with sensitivities of 75.00% and 76.00%, and specificities of 73.07% and 75.00%, respectively. There are no significant differences between AUC values computed from arterial phases and venous phases images in both training and validation groups (P < 0.05). CONCLUSION: The optimally selected radiomics features computed from CT-enhanced different-phase images can provide new imaging marks to evaluate efficacy of the targeted therapy in NSCLC with a high diagnostic value.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Humanos , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/terapia , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/terapia , Tomografía Computarizada por Rayos X , Inmunoterapia , Área Bajo la Curva , Estudios Retrospectivos
4.
Jpn J Radiol ; 41(6): 669-679, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36607550

RESUMEN

PURPOSE: To conduct a comparative study of image quality, radiation dose, and iodine intake in hepatic computed tomographic angiography (CTA) of overweight patients with different Gemstone Spectral Imaging (GSI) noise indexes combined with different concentrations of contrast medium. MATERIALS AND METHODS: Ninety patients with a body mass index of ≥ 25 kg/m2 were divided into three groups (A, B and C), each with 30 patients. The three groups underwent hepatic CTA with different NI of 7, 11 and 15, respectively, and were injected with different iodine concentrations of 370, 350 and 320 mgI/mL, respectively. Five sets of images at 40-60 keV (interval, 5 keV) were reconstructed in each group. The CT value, image noise, contrast-to-noise ratio (CNR) and subjective score of the hepatic artery and vein, and portal vein in different monochromatic image sets were analyzed to select the optimal energy level in each group. The differences in CT value, image noise, CNR and a subjective score of hepatic artery and vein, portal vein in the optimal monochromatic images among the three groups were compared, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the effective dose and iodine intake were calculated. RESULTS: The 40 keV was determined to be the optimal energy level for the monochromatic image sets in each group. No significant group differences were noted in the CT value, image noise, CNR, and subjective image scores of the hepatic artery and vein, and portal vein for the optimal monochromatic images (P > 0.05). Compared with group A, the effective dose and iodine intake in group B were reduced by 50.18% and 9.3%, and by 58.12% and 14.23% in group C, respectively. CONCLUSION: A low-concentration contrast medium combined with a high-noise GSI index in hepatic CTA of overweight patients can reduce the radiation dose and iodine intake while ensuring image quality.


Asunto(s)
Angiografía por Tomografía Computarizada , Yodo , Humanos , Angiografía por Tomografía Computarizada/métodos , Estudios de Factibilidad , Sobrepeso/diagnóstico por imagen , Dosis de Radiación , Medios de Contraste , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
5.
J Xray Sci Technol ; 30(6): 1261-1272, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36214032

RESUMEN

OBJECTIVES: To compare image quality, radiation dose, and iodine intake of coronary computed tomography angiography (CCTA) acquired by wide-detector using different tube voltages and different concentrations of contrast medium (CM) for overweight patients. MATERIALS AND METHODS: A total of 150 overweight patients (body mass index≥25 kg/m2) who underwent CCTA are enrolled and divided into three groups according to scan protocols namely, group A (120 kVp, 370 mgI/ml CM); group B (100 kVp, 350 mgI/ml CM); and group C (80 kVp, 320 mgI/ml CM). The CT values, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure-of-merit (FOM) of all images are calculated. Images are subjectively assessed using a 5-point scale. In addition, the CT dose index volume (CTDIvol) and dose length product (DLP) of each patient are recorded. The effective radiation dose (ED) is also calculated. Above data are then statistically analyzed. RESULTS: The mean CT values, SNR, CNR, and subjective image quality of group A are significantly lower than those of groups B and C (P < 0.001), but there is no significant difference between groups B and C (P > 0.05). FOMs show a significantly increase trend from group A to C (P < 0.001). The ED values and total iodine intake in groups B and C are 30.34% and 68.53% and 10.22% and 16.85% lower than those in group A, respectively (P < 0.001). CONCLUSION: The lower tube voltage and lower concentration of CM based on wide-detector allows for significant reduction in iodine load and radiation dose in CCTA for overweight patients comparing to routine scan protocols. It also enhances signal intensity of CCTA and maintains image quality.


Asunto(s)
Angiografía por Tomografía Computarizada , Yodo , Humanos , Angiografía por Tomografía Computarizada/métodos , Sobrepeso/diagnóstico por imagen , Dosis de Radiación , Estudios de Factibilidad , Medios de Contraste , Estudios Prospectivos , Angiografía Coronaria/métodos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
7.
Int J Ophthalmol ; 11(9): 1451-1457, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30225217

RESUMEN

AIM: To investigate common polymorphisms in VEGF, ACE, TNF and GST genes with retinopathy of prematurity (ROP) risk among Chinese infants. METHODS: Nine polymorphisms in the above genes were genotyped on 724 advanced cases of ROP and 878 prematurely-born infants of low birth weight who were without any ophthalmologic disease. The frequencies of the polymorphisms were compared between cases and controls to identify the association present, if any. RESULTS: Of the nine polymorphisms, only two showed significant associations: ACE insertion deletion (ID) polymorphism (P=0.031) and TNF -308G/A polymorphism (P<0.001). The former was associated with a reduced ROP risk [ID genotype, adjusted OR (aOR): 0.603, 95%CI: 0.427-0.893, P=0.034; DD genotype, aOR: 0.468, 95%CI: 0.229-0.626, P=0.002], while the latter showed an increased risk (GA genotype, aOR: 1.956, 95%CI: 1.396-2.465, P<0.001; AA genotype, aOR: 2.809, 95%CI: 1.802-4.484, P<0.001). The association was also noted at the allele level (ACE D allele aOR: 0.698, 95%CI: 0.294-0.883, P<0.001; TNF -308A allele aOR: 1.776, 95%CI: 1.446-2.561, P<0.001). CONCLUSION: The ACE ID polymorphism can protect against ROP development while the TNF -308G/A can increase the risk of the disease among Chinese infants.

8.
Korean J Radiol ; 19(4): 578-584, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29962864

RESUMEN

Objective: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. Materials and Methods: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis. Results: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was 24.6 ± 10.9, 18.1 ± 8.3, and 11.6 ± 4.6, respectively (p < 0.001) with subjective scores of 4.7 ± 0.2, 4.0 ± 0.3, and 3.6 ± 0.4, respectively (p < 0.001). CNR of the hepatic portal vein was 6.9 ± 2.7, 4.3 ± 1.9, and 3.0 ± 2.1, respectively (p < 0.001) with subjective scores of 4.5 ± 0.3, 3.9 ± 0.4, and 3.3 ± 0.3, respectively (p < 0.001). CNR of the hepatic vein was 5.7 ± 2.3, 4.2 ± 1.9, and 2.7 ± 1.4, respectively with subjective scores of 4.3 ± 0.3, 3.8 ± 0.4, and 3.2 ± 0.3, respectively (p < 0.001). Conclusion: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Arteria Hepática/diagnóstico por imagen , Venas Hepáticas/diagnóstico por imagen , Vena Porta/diagnóstico por imagen , Intensificación de Imagen Radiográfica/métodos , Adulto , Anciano , Angiografía/métodos , Femenino , Humanos , Hígado/irrigación sanguínea , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
9.
J Comput Assist Tomogr ; 41(2): 263-270, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27824666

RESUMEN

OBJECTIVE: The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest gemstone spectral imaging (GSI) combination of different scanning protocols with the adaptive statistical iterative reconstruction 2.0 algorithm. METHODS: A total of 90 patients who had undergone a CTA of the kidney were divided into 3 groups (A, B, and C), with 30 patients in each group. Group A underwent a routine CT examination, whereas groups B and C underwent GSI with different scanning protocols. All images were restructured using the adaptive statistical iterative reconstruction 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by 2 independent radiologists. The CT dose index of volume and the dose-length product were recorded, and the mean value was calculated. The dose-length product was converted to the effective dose. All data were compared with a 1-way analysis of variance. RESULTS: The SNR, CNR, and subjective image quality in group A were significantly lower than those in groups B and C (P < 0.01). There were no significant differences in SNR, CNR, and subjective image quality between groups B and C. The effective dose of group C decreased by 46.05% and 15.03% relative to those of groups A and B, respectively (P < 0.01). CONCLUSIONS: The latest GSI with different scanning protocols can more effectively reduce the radiation dose than can the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Riñón/diagnóstico por imagen , Dosis de Radiación , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Algoritmos , Índice de Masa Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Relación Señal-Ruido
10.
Acad Radiol ; 23(12): 1513-1520, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27717760

RESUMEN

RATIONALE AND OBJECTIVES: This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). MATERIALS AND METHODS: A total of 480 patients who had a CTPA were divided into group A (18.5 kg/m2 ≤ BMI < 25 kg/m2), group B (25 kg/m2 ≤ BMI < 30 kg/m2), and group C (BMI ≥ 30 kg/m2), according to their BMI values; each group had 160 patients. The three groups were further randomly divided into four subgroups: A1, A2, A3, A4; B1, B2, B3, B4; and C1, C2, C3, C4, with corresponding NI values of 26, 36, 40, and 46, respectively. All images were restructured with the ASiR algorithm, and the images with the lowest NI (26 Hounsfield units) in each group were used as reference standard. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the pulmonary artery of each group were calculated. Subjective image quality was evaluated using a five-score method by two independent radiologists. The CT dose index of volume and dose-length product were recorded and were converted to effective dose (ED). SNR and CNR in the group A, B, and C subgroups were compared to repeated measures analysis of variance, and the subjective score, Volumetric CT dose index of volume, dose-length product, and ED were compared to one-way analysis of variance. RESULTS: For groups A and B, the SNR, CNR, and subjective scores of the images in their subgroups showed no statistical differences (P >.05). The ED in subgroups A4 and B4 was significantly lower than that in subgroups A1 (by 33.24%) and B1 (by 34.47%) (P <.01). For group C, there was no significant difference in the SNR, CNR, and the subjective image scores between subgroups C3 and C1 (P >.05). The ED in subgroup C3 was significantly lower than the ED in subgroup C1 (by 47.75%) (P <.01) CONCLUSIONS: Patient BMI-dependent NI settings that are higher than the recommended value may be used in CTPA with automatic tube current modulation and ASiR to effectively reduce radiation dose while maintaining diagnostic image quality.


Asunto(s)
Índice de Masa Corporal , Angiografía por Tomografía Computarizada/métodos , Embolia Pulmonar/diagnóstico por imagen , Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Pulmonar/diagnóstico por imagen , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Relación Señal-Ruido , Tomografía Computarizada Espiral/métodos
11.
J Comput Assist Tomogr ; 40(5): 784-90, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27560023

RESUMEN

OBJECTIVE: The objective of our study was to compare the image quality and radiation dose of computed tomography pulmonary angiography (CTPA) in patients with different body mass indexes using 100-kVp combination of different noise indexes (NIs) and 120-kVp scan protocol with the adaptive statistical iterative reconstruction 2.0 algorithm (ASiR 2.0). METHODS: A total of 120 patients who had undergone a CTPA were divided into 4 groups (A, B, C, and D), with 30 patients in each group. Group A underwent 120-kVp CT scan protocol in combination with NI = 25, while groups B, C, and D underwent 100-kVp CT scan protocol in combination with NI = 30, 35, and 40, respectively. All images were restructured using ASiR 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the CTPA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by 2 independent radiologists. The CT dose index of volume and dose-length product were recorded, and the mean value was calculated. The dose-length product was converted to the effective dose. RESULTS: There were no significant differences in SNR, CNR, and subjective image quality among the groups A, B, C, and D. The effective dose of group D decreased by 48.33% and 27.27% relative to groups A and B, respectively (P < 0.01). CONCLUSIONS: The 100-kVp CT scan protocol in combination with NI = 40 can more effectively reduce the radiation dose than can the 120-kVp CT scan protocol in combination with NI = 25 for a CTPA while still maintaining diagnostic image quality.


Asunto(s)
Artefactos , Embolia Pulmonar/diagnóstico por imagen , Exposición a la Radiación/análisis , Protección Radiológica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Algoritmos , Femenino , Humanos , Masculino , Dosis de Radiación , Exposición a la Radiación/prevención & control , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...