Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Intervalo de año de publicación
1.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;51(2): e6825, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-889030

RESUMEN

This study aimed to evaluate the feasibility and performance of Arndt-endobronchial blocker (Arndt) combined with laryngeal mask airway (LMA) compared with left-sided double-lumen endobronchial tube (L-DLT) in morbidly obese patients in one-lung ventilation (OLV). In a prospective, randomized double-blind controlled clinical trial, 80 morbidly obese patients (ASA I-III, aged 20-70) undergoing general anesthesia for elective thoracic surgeries were randomly allocated into groups Arndt (n=40) and L-DLT (n=40). In group Arndt, a LMA™ Proseal was placed followed by an Arndt-endobronchial blocker. In group L-DLT, patients were intubated with a left-sided double-lumen endotracheal tube. Primary endpoints were the airway establishment, ease of insertion, oxygenation, lung collapse and surgical field exposure. Results showed similar ease of airway establishment and tube/device insertion between the two groups. Oxygen arterial pressure (PaO2) of patients in the Arndt group was significantly higher than L-DLT (154±46 vs 105±52 mmHg; P<0.05). Quality of lung collapse and surgical field exposure in the Arndt group was significantly better than L-DLT (effective rate 100 vs 90%; P<0.05). Duration of surgery and anesthesia were significantly shorter in the Arndt group (2.4±1.7 vs 3.1±1.8 and 2.8±1.9 vs 3.8±1.8 h, respectively; P<0.05). Incidence of hoarseness of voice and incidence and severity of throat pain at the post-anesthesia care unit and 12, 24, 48, and 72 h after surgery were significantly lower in the Arndt group (P<0.05). Findings suggested that Arndt-endobronchial blocker combined with LMA can serve as a promising alternative for morbidly obese patients in OLV in thoracic surgery.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Obesidad Mórbida/cirugía , Máscaras Laríngeas/normas , Ventilación Unipulmonar/instrumentación , Intubación Intratraqueal/instrumentación , Atelectasia Pulmonar , Factores de Tiempo , Método Doble Ciego , Estudios Prospectivos , Resultado del Tratamiento , Diseño de Equipo , Ventilación Unipulmonar/métodos , Tempo Operativo , Intubación Intratraqueal/métodos
2.
Rev. bras. pesqui. méd. biol ; Braz. j. med. biol. res;51(2): e6825, 2018.
Artículo en Inglés | LILACS | ID: biblio-1019561

RESUMEN

This study aimed to evaluate the feasibility and performance of Arndt-endobronchial blocker (Arndt) combined with laryngeal mask airway (LMA) compared with left-sided double-lumen endobronchial tube (L-DLT) in morbidly obese patients in one-lung ventilation (OLV). In a prospective, randomized double-blind controlled clinical trial, 80 morbidly obese patients (ASA I-III, aged 20-70) undergoing general anesthesia for elective thoracic surgeries were randomly allocated into groups Arndt (n=40) and L-DLT (n=40). In group Arndt, a LMA™ Proseal was placed followed by an Arndt-endobronchial blocker. In group L-DLT, patients were intubated with a left-sided double-lumen endotracheal tube. Primary endpoints were the airway establishment, ease of insertion, oxygenation, lung collapse and surgical field exposure. Results showed similar ease of airway establishment and tube/device insertion between the two groups. Oxygen arterial pressure (PaO2) of patients in the Arndt group was significantly higher than L-DLT (154±46 vs 105±52 mmHg; P<0.05). Quality of lung collapse and surgical field exposure in the Arndt group was significantly better than L-DLT (effective rate 100 vs 90%; P<0.05). Duration of surgery and anesthesia were significantly shorter in the Arndt group (2.4±1.7 vs 3.1±1.8 and 2.8±1.9 vs 3.8±1.8 h, respectively; P<0.05). Incidence of hoarseness of voice and incidence and severity of throat pain at the post-anesthesia care unit and 12, 24, 48, and 72 h after surgery were significantly lower in the Arndt group (P<0.05). Findings suggested that Arndt-endobronchial blocker combined with LMA can serve as a promising alternative for morbidly obese patients in OLV in thoracic surgery.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Obesidad Mórbida/cirugía , Máscaras Laríngeas/normas , Procedimientos Quirúrgicos Torácicos/instrumentación , Ventilación Unipulmonar/instrumentación , Intubación Intratraqueal/instrumentación , Dolor Postoperatorio/etiología , Atelectasia Pulmonar , Factores de Tiempo , Faringitis/etiología , Ventiladores Mecánicos/normas , Método Doble Ciego , Estudios Prospectivos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Procedimientos Quirúrgicos Torácicos/métodos , Diseño de Equipo , Ventilación Unipulmonar/métodos , Tempo Operativo , Intubación Intratraqueal/métodos
3.
Braz J Med Biol Res ; 51(2): e6825, 2017 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-29267506

RESUMEN

This study aimed to evaluate the feasibility and performance of Arndt-endobronchial blocker (Arndt) combined with laryngeal mask airway (LMA) compared with left-sided double-lumen endobronchial tube (L-DLT) in morbidly obese patients in one-lung ventilation (OLV). In a prospective, randomized double-blind controlled clinical trial, 80 morbidly obese patients (ASA I-III, aged 20-70) undergoing general anesthesia for elective thoracic surgeries were randomly allocated into groups Arndt (n=40) and L-DLT (n=40). In group Arndt, a LMA™ Proseal was placed followed by an Arndt-endobronchial blocker. In group L-DLT, patients were intubated with a left-sided double-lumen endotracheal tube. Primary endpoints were the airway establishment, ease of insertion, oxygenation, lung collapse and surgical field exposure. Results showed similar ease of airway establishment and tube/device insertion between the two groups. Oxygen arterial pressure (PaO2) of patients in the Arndt group was significantly higher than L-DLT (154±46 vs 105±52 mmHg; P<0.05). Quality of lung collapse and surgical field exposure in the Arndt group was significantly better than L-DLT (effective rate 100 vs 90%; P<0.05). Duration of surgery and anesthesia were significantly shorter in the Arndt group (2.4±1.7 vs 3.1±1.8 and 2.8±1.9 vs 3.8±1.8 h, respectively; P<0.05). Incidence of hoarseness of voice and incidence and severity of throat pain at the post-anesthesia care unit and 12, 24, 48, and 72 h after surgery were significantly lower in the Arndt group (P<0.05). Findings suggested that Arndt-endobronchial blocker combined with LMA can serve as a promising alternative for morbidly obese patients in OLV in thoracic surgery.


Asunto(s)
Intubación Intratraqueal/instrumentación , Máscaras Laríngeas/normas , Obesidad Mórbida/cirugía , Ventilación Unipulmonar/instrumentación , Procedimientos Quirúrgicos Torácicos/instrumentación , Adulto , Anciano , Método Doble Ciego , Diseño de Equipo , Femenino , Humanos , Intubación Intratraqueal/métodos , Masculino , Persona de Mediana Edad , Ventilación Unipulmonar/métodos , Tempo Operativo , Dolor Postoperatorio/etiología , Faringitis/etiología , Estudios Prospectivos , Atelectasia Pulmonar , Reproducibilidad de los Resultados , Procedimientos Quirúrgicos Torácicos/métodos , Factores de Tiempo , Resultado del Tratamiento , Ventiladores Mecánicos/normas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA