Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
JACC Cardiovasc Interv ; 15(16): 1652-1660, 2022 08 22.
Artículo en Inglés | MEDLINE | ID: mdl-35981839

RESUMEN

BACKGROUND: It is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs). OBJECTIVES: The aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs. METHODS: In this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes. RESULTS: A total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women. CONCLUSIONS: In patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Estudios Retrospectivos , Caracteres Sexuales , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
Front Cardiovasc Med ; 9: 794850, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35369357

RESUMEN

Objective: We sought to conduct a systematic review and meta-analysis of clinical adverse events in patients undergoing transcatheter aortic valve replacement (TAVR) with bicuspid aortic valve (BAV) vs. tricuspid aortic valve (TAV) anatomy and the efficacy of balloon-expandable (BE) vs. self-expanding (SE) valves in the BAV population. Comparisons aforementioned will be made stratified into early- and new-generation devices. Differences of prosthetic geometry on CT between patients with BAV and TAV were presented. In addition, BAV morphological presentations in included studies were summarized. Method: Observational studies and a randomized controlled trial of patients with BAV undergoing TAVR were included according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guideline. Results: A total of 43 studies were included in the final analysis. In patients undergoing TAVR, type 1 BAV was the most common phenotype and type 2 BAV accounted for the least. Significant higher risks of conversion to surgical aortic valve replacement (SAVR), the need of a second valve, a moderate or severe paravalvular leakage (PVL), device failure, acute kidney injury (AKI), and stroke were observed in patients with BAV than in patients with TAV during hospitalization. BAV had a higher risk of new permanent pacemaker implantation (PPI) both at hospitalization and a 30-day follow-up. Risk of 1-year mortality was significantly lower in patients with BAV than that with TAV [odds ratio (OR) = 0.85, 95% CI 0.75-0.97, p = 0.01]. BE transcatheter heart valves (THVs) had higher risks of annular rupture but a lower risk of the need of a second valve and a new PPI than SE THVs. Moreover, BE THV was less expanded and more elliptical in BAV than in TAV. In general, the rates of clinical adverse events were lower in new-generation THVs than in early-generation THVs in both BAV and TAV. Conclusions: Despite higher risks of conversion to SAVR, the need of a second valve, moderate or severe PVL, device failure, AKI, stroke, and new PPI, TAVR seems to be a viable option for selected patients with severe bicuspid aortic stenosis (AS), which demonstrated a potential benefit of 1-year survival, especially among lower surgical risk population using new-generation devices. Larger randomized studies are needed to guide patient selection and verified the durable performance of THVs in the BAV population.

4.
J Hazard Mater ; 400: 123313, 2020 12 05.
Artículo en Inglés | MEDLINE | ID: mdl-32947713

RESUMEN

Particulate organic matter (POM) includes humin and non-degradable residues, and the knowledge about its composition, evolution and environmental behavior is limited. The composition, evolution and its influence on dechlorination of the POM in landfill was studied. The results show that POM accounts for 27 %-57 % of the organic matter in landfill cell, which is mainly composed of protein-, fulvic- and humic-like components. Firmicutes and Proteobacteria were the main microorganisms driving the compositional evolution of POM during the landfilling process. The electron acceptance capacities (EAC) and electron donating capacities (EDC) of POM were in the range of 0.05-0.51 µmol/gC-1 and 0.13-0.66 µmol/gC-1, respectively, and the average EAC and EDC of POM in the intermediate and old stage of landfill were higher than those in the initial stage. The combined action of MR-1 and POM increased the degradation rate of PCP by 20 %-40 %, which was ascribed to the reduction capacities and electron transfer process of POM. POM derived from the intermediate and old stages promoted PCP dechlorination more effectively when compared with the initial stage due to its high electron transfer capacities (ETC), which are of great significance for soil in-situ bioremediation.

6.
JACC Cardiovasc Interv ; 12(12): 1164-1171, 2019 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-31221307

RESUMEN

OBJECTIVES: The authors sought to better understand the stent geometry of the Lotus valve after transcatheter aortic valve replacement (TAVR) and its potential implications for valve size selection. BACKGROUND: The authors hypothesized that the greatest interference between the frame and aortic valvar complex occurs across the aortic valve leaflets. METHODS: The authors retrospectively analyzed the multidetector computed tomography (MDCT) scans of 32 consecutive patients undergoing Lotus valve (Boston Scientific, Natick, Massachusetts) implantation. The prosthesis cross section was analyzed at 3-mm increments along its length. The plane where the frame had the smallest area was defined as the waist. The corresponding plane of the waist on pre-procedural MDCT was identified by surrounding structures such as calcium deposits, commissural fusion, and commissural gaps, and was referred to as the supra-annulus. The spline of the supra-annulus was circumscribed with reference to the post-implant stent geometry at the waist. RESULTS: The waist was 5.8 ± 1.7 mm higher than the native annulus on post-procedural MDCT. The waist had a nearly 2-fold larger compression rate than the stent at the native annulus level (36.3 ± 10.4% vs. 18.9 ± 9.6%; p < 0.01), irrespective of valve morphologies. The supra-annulus was 5.9 ± 1.6 mm higher than the annulus on pre-procedural MDCT. Patients had an approximately 17% decrease in area from the annulus to the supra-annulus (18.3 ± 4.4% for bicuspid morphology and 16.0 ± 3.5% for tricuspid morphology). CONCLUSIONS: Major interference between the implanted prosthesis and anatomy occurred at a level above the annulus. The decrease in area from the annulus to supra-annulus may explain the feasibility of implanting a smaller valve than that suggested by traditional annular measurements.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Stents , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Hemodinámica , Humanos , Masculino , Tomografía Computarizada Multidetector , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
7.
Int J Cardiovasc Imaging ; 34(11): 1761-1767, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29915878

RESUMEN

To compare reverse left ventricular (LV) remodeling after transcatheter aortic valve replacement (TAVR) between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV). We retrospectively reviewed data of patients with at least two serial echocardiographic follow-ups (1, 3, 6 months and 1 year) post-TAVR. A total of 116 patients were identified. BAV morphology was documented in 67 patients. LV mass index (LVMi) at baseline was not significantly different between the TAV and BAV group (178.0 ± 6.9 vs. 166.3 ± 6.4 g/m2, P = 0.14). Reverse LV remodeling was observed in both BAV and TAV patients, but the reduction of LVMi from baseline was significantly more pronounced in TAV patients compared with BAV patients from 6 months post-TAVR (- 56.3 ± 8.1 vs. - 30.0 ± 4.7 g/m2, P < 0.01 at 6-month follow-up; - 60.6 ± 7.6 vs. - 37.9 ± 6.2 g/m2, P = 0.02 at 1-year follow-up). EDV value changes during follow-up were similar between patient with TAV and BAV. There were no significant differences in the proportions of patients with more than mild PVL or new permanent pacemaker between TAV and BAV morphology throughout the follow-up. Patients with bicuspid morphology might experience less pronounced reverse LV remodeling post-TAVR than patients with tricuspid morphology.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Función Ventricular Izquierda , Remodelación Ventricular , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Ecocardiografía , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
8.
Cardiol J ; 24(4): 350-357, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28248407

RESUMEN

BACKGROUND: To investigate the individual sequential hemodynamic changes after transcatheter aortic valve implantation (TAVI), especially for patients with bicuspid aortic valve (BAV), in comparison with tricuspid aortic valve (TAV). METHODS: The study population comprised 85 patients with severe aortic stenosis who underwent TAVI for BAV (n = 49) or TAV (n = 36) with at least two serial echocardiographic follow-ups. Doppler echocardiography was scheduled to be performed at discharge and 1, 3, 6 months and 1 year after the procedure. D peak transvalvular velocities and D mean transvalvular gradients were calculated as the difference at follow-up time points and discharge. Paravalvular leak (PVL) was assessed as another indicator for prosthesis performance. RESULTS: Comparisons between patients with BAV and TAV revealed similar gradient performances (1.00 [-2.00, 2.00] vs. 1.00 [-0.25, 5.00] mm Hg, p = 0.57 at 1 month; -0.71 ± 7.52 vs. 1.55 ± 3.97 mm Hg, p = 0.21 at 3 months; 0.96 ± 7.81 vs. 1.53 ± 5.85 mm Hg, p = 0.79 at 6 months; 1.00 [-0.50, 2.25] vs. 3.00 [-0.50, 7.50] mm Hg, p = 0.07 at 1 year). Moreover, the incidence of ≥ mild PVL was not significantly different in patients with BAV and TAV during follow-up (34.88% vs. 19.35%, p = 0.14 at 1 month; 45.83% vs. 27.27%, p = 0.19 at 3 months; 30.00% vs. 23.53%, p = 0.89 at 6 months; 30.00% vs. 17.65%, p = 0.56 at 1 year). CONCLUSIONS: TAVI is effective and applicable in BAV anatomy with sustained and acceptable mid- -term prosthesis hemodynamic performance. (Cardiol J 2017; 24, 4: 350-357).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Hemodinámica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Enfermedad de la Válvula Aórtica Bicúspide , Ecocardiografía Doppler , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/fisiopatología , Prótesis Valvulares Cardíacas , Humanos , Masculino , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 89(S1): 528-533, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28318133

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A-Valve and the CoreValve; however, there is no data on their comparative performance. METHODS: Consecutive patients undergoing TAVI with the aforementioned devices were included. The outcomes were reported according to the Valve Academic Research Consortium-2 (VARC) definitions. RESULTS: A total of 54 TAVI procedures were performed, 27 with the CoreValve and the other 27 with the Venus A-Valve. An additional valve was required in 4 (14.8%) and 3 (11.1%) patients, and the VARC-2 device success rates were 81.5 and 85.2%, respectively. The incidences of common complications were similar, except for the significantly less frequent pacemaker insertion in the Venus A-Valve group (7.4 vs. 37.0%, P = 0.03). Within 30 days, 2 (3.7%) patients died, 1 in each group, and both had a bicuspid aortic valve (BAV). No other serious complications, such as annular rupture, coronary obstruction and aortic dissection, occurred in the 32 BAV patients treated with the Venus A-Valve (14) or the CoreValve (18). After 2-years of follow-up, there was no significant difference between CoreValve group and Venus-A group (11.1 vs. 7.4%, P = 0.64). CONCLUSION: TAVI with the domestic Venus A-Valve is feasible, safe, and can produce favorable short-term outcomes comparable to those with the CoreValve in inoperable or high-risk patients with tricuspid and bicuspid aortic valve stenosis. © 2017 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , China , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
10.
Huan Jing Ke Xue ; 32(10): 2961-5, 2011 Oct.
Artículo en Chino | MEDLINE | ID: mdl-22279909

RESUMEN

The effect of nucleation modes on the induced crystallization process for copper contained wastewater treatment was studied. Tests were undertaken to observe the difference of copper removal efficiency and the crystal growth with homogeneous and heterogeneous nucleation. When the influent copper concentration was 50 mg x L(-1), copper removal efficiency could achieve 98.0% with the heterogeneous and 26.3% with homogeneous nucleation. And the SEM-EDS showed that the growth of crystals with heterogeneous nucleation was better and the purity of the crystals was higher than that with homogeneous nucleation. It is obvious that the homogeneous nucleation was an unfavorable condition on the induced crystallization process. Then the research devoted to discuss the process of induced crystallization with the two different nucleation mode and analysis the influencing mechanism of the homogeneous nucleation on the induced crystallization.


Asunto(s)
Cobre/aislamiento & purificación , Eliminación de Residuos Líquidos/métodos , Aguas Residuales/química , Cobre/química , Cristalización
11.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 39(1): 126-9, 2008 Jan.
Artículo en Chino | MEDLINE | ID: mdl-18390219

RESUMEN

OBJECTIVE: To analyse the clinical factors that contribute to the rise of the cardiac injury marker troponin after coronary intervention and the impact of the rise of troponin on the clinical outcomes. METHODS: Troponin I was measured after elective coronary intervention in 129 patients whose baseline levels of troponin were normal. The clinical outcomes of the patients were follow-up. RESULTS: The rise of troponin I was associated with side branch losses, flow impairments such as no flow or slow flow and diabetes. The incidence of myocardial infarction increased with the rise of troponin I. The angina onsets were more common and the length of stay were longer in the patients with the rise of troponin I than those without. CONCLUSION: The rise of troponin after coronary intervention is related to the complex coronary lesions and the complications of intervention procedures. To a certain extent, the level of troponin can predict the patients' outcomes.


Asunto(s)
Angioplastia Coronaria con Balón/efectos adversos , Troponina I/sangre , Anciano , Angina de Pecho/epidemiología , Diabetes Mellitus/epidemiología , Femenino , Humanos , Incidencia , Tiempo de Internación , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...