Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Medicine (Baltimore) ; 98(20): e15248, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-31096433

RESUMEN

BACKGROUND: This study aimed to compare the efficacy and safety of oral tranexamic acid (TXA) with intravenous (IV) TXA in reducing perioperative blood loss in total-knee arthroplasty (TKA) and total-hip arthroplasty (THA). METHODS: PubMed, Web of Science, Embase, and Cochrane Library were fully searched for relevant studies. Studies comparing the efficacy and safety of oral TXA with IV TXA in TKA and THA were included in this research. Odds ratio (OR) or risk difference (RD) was applied to compare dichotomous variables, while mean difference (MD) was used to compare continues variables. RESULTS: A total of 7 studies (5 randomized controlled trials and 2 retrospective studies) were included into this study. As for patients undergoing TKA or THA, there were no obvious differences between oral TXA group and IV TXA group in hemoglobin (Hb) drop (MD = 0.06, 95% confidence interval [CI] = -0.01 to 0.13, P = .09), transfusion rate (OR = 0.78, 95% CI = 0.54-1.13, P = .19), total blood loss (MD = 16.31, 95% CI = -69.85 to 102.46, P = .71), total Hb loss (MD = 5.18, 95% CI = -12.65 to 23.02, P = .57), length of hospital stay (MD = -0.06, 95% CI = -0.30 to 0.18, P = .63), drain out (MD = 21.04, 95% CI = -15.81 to 57.88, P = .26), incidence of deep vein deep vein thrombosis (RD = 0.00, 95% CI = -0.01 to 0.01, P = .82) or pulmonary embolism (RD = 0.00, 95% CI = -0.01 to 0.01, P = .91). The sample size of this study was small and several included studies were with relatively low quality. CONCLUSION: Oral TXA is equivalent to IV TXA in reducing perioperative blood loss and should be recommended in TKA and THA. More high-quality studies are needed to elucidate this issue.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Pérdida de Sangre Quirúrgica/prevención & control , Ácido Tranexámico/administración & dosificación , Ácido Tranexámico/uso terapéutico , Administración Intravenosa , Administración Oral , Adulto , Anciano , Anciano de 80 o más Años , Antifibrinolíticos/administración & dosificación , Antifibrinolíticos/efectos adversos , Antifibrinolíticos/uso terapéutico , Femenino , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Periodo Perioperatorio/estadística & datos numéricos , Embolia Pulmonar/epidemiología , Embolia Pulmonar/etiología , Embolia Pulmonar/prevención & control , Ensayos Clínicos Controlados Aleatorios como Asunto , Ácido Tranexámico/efectos adversos , Trombosis de la Vena/epidemiología , Trombosis de la Vena/etiología , Trombosis de la Vena/prevención & control
2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 31(2): 203-209, 2017 02 15.
Artículo en Chino | MEDLINE | ID: mdl-29786254

RESUMEN

Objective: To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. Methods: The L 1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. Results: A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared with preoperative ones ( t=14.842, P=0.006; t=36.927, P=0.002; t=-36.031, P=0.001). Thirty-one patients were followed up 8-24 months (mean, 18.7 months). All incision healed by first intention, and no complication occurred. During the follow-up, X-ray film and CT showed that pedicle screw was accurately placed without loosening or breakage, and with good fusion of intervertebral bone graft. Conclusion: 3D-printing navigational templates in Quadrant minimally invasive system can help lumbar surgery gain minimal invasion, less radiation, and accurate placement.


Asunto(s)
Tornillos Pediculares , Impresión Tridimensional , Fusión Vertebral/instrumentación , Adulto , Femenino , Humanos , Vértebras Lumbares , Región Lumbosacra , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
3.
Artículo en Chino | MEDLINE | ID: mdl-27411265

RESUMEN

OBJECTIVE: To evaluate the effectiveness of high tibial osteotomy (HTO) assisted by three-dimensional (3-D) printing technology for correction of varus knee with osteoarthritis. METHODS: Between January 2014 and June 2015, 16 patients (20 knees) with varus knee and osteoarthritis underwent HTO assisted by 3-D printing technology; a locking compression plate was used for internal fixation after HTO. There were 6 males and 10 females, aged 30-60 years (mean, 45.5 years). The disease duration was 1-10 years (mean, 6.2 years). The unilateral knee was involved in 12 cases and bilateral knees in 4 cases. According to Koshino's staging system, 3 knees were classified as stage I, 7 knees as stage II, 8 knees as stage III, and 2 knees as stage IV. Preoperative Hospital for Special Surgery (HSS) knee score was 63.8 ± 2.2; the femorotibial angle was (184.8 ± 2.9)°; and Insall-Salvati index was 1.03 ± 0.13. RESULTS: All the wounds healed primarily, and no complication of infection, osteofacial compartment syndrom, or deep vein thrombosis was observed. All patients were followed up 6-18 months (mean, 12.6 months). Personal paralysis was observed in 1 case (1 knee), and was cured after expectant treatment. Bone union time was 2.7-3.4 months (mean, 2.9 months). At 6 months after operation, the femorotibial angle was (173.8 ± 2.0)°, showing significant difference when compared with preoperative one (t = 11.70, P = 0.00); Insall-Salvati index was 1.04 ± 0.12, showing no significant difference when compared with preoperative one (t = -0.20, P = 0.85); and HSS knee score was significantly increased to 88.9 ± 3.1 (t = -25.44, P = 0.00). At last follow-up, the results were excellent in 13 knees, good in 6 knees, fair in 1 knee, and the excellent and good rate was 95%. CONCLUSION: 3-D printing cutting block can greatly improve the accuracy of HTO, avoid repeated X-ray and multiple osteotomy, shorten the operation time, and ensure better effectiveness for correction of varus knee with osteoarthritis.


Asunto(s)
Hallux Varus/cirugía , Articulación de la Rodilla/cirugía , Osteoartritis de la Rodilla/cirugía , Osteotomía/métodos , Impresión Tridimensional , Tibia/cirugía , Adulto , Placas Óseas , Femenino , Fijación Interna de Fracturas , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Osteotomía/instrumentación , Radiografía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA