Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 94(1): 013508, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36725546

RESUMEN

To measure plasma density and magnetic fluctuations on the HL-2M tokamak simultaneously, a new diagnostic system combining Doppler backscattering (DBS) and cross-polarization scattering (CPS) is under development. It is essential to understand the propagation of injected and scattered rays to support the electronic/quasi-optical design and subsequent interpretation of the detected signals of the multi-channel DBS/CPS measurements. Thus, ray-tracing analysis with the axisymmetric ray-tracing code BORAY has been performed to estimate the scattering location and wavenumbers of the density and magnetic fluctuations. In addition, the influence of accordance between toroidal and poloidal launch angles is investigated. The received DBS/CPS signal quality can be improved by matching the parallel wavenumber in the direction of magnetic field lines.

2.
Rev Sci Instrum ; 92(4): 043539, 2021 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243464

RESUMEN

The supersonic molecular beam injection (SMBI) technique is widely used in magnetic fusion devices for plasma fueling and active control of particles. The beam flow formed by the SMBI system is directly visualized by a newly established schlieren diagnostic system on the SMBI testing platform. This schlieren system could provide a 2D density distribution of the beam with the sub-mm spatial resolution by detecting the change in the refractive index of the medium caused by the SMBI in the low-pressure vacuum chamber. The structure and the divergence angle of the supersonic molecular beam for fusion plasma fueling are first measured. Additionally, the density profile of the supersonic molecular beam is reconstructed from the measured light intensity by the schlieren system. The experimental comparison between the standard nozzle and the optimized nozzle of the SMBI system shows the great potential of the diagnostic system in optimizing the beam characteristics.

3.
Rev Sci Instrum ; 89(10): 10H104, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399917

RESUMEN

The Doppler backward scattering (DBS) reflectometer has become a well-established and versatile diagnostic technique for the measurement of density fluctuations and flows in magnetically confined fusion experiments. In this work, a novel multiple fixed-frequency array source with a multiplexer technique is developed and applied in the multi-channel DBS system. The details of the system design and laboratory tests are presented. Preliminary results of Doppler shift frequency spectra measured by the multi-channel DBS reflectometer systems are obtained. Characteristics of plasma rotation and turbulence before and after supersonic molecular beam injection are analyzed.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA