Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Front Immunol ; 13: 951817, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36263036

RESUMEN

Primary pulmonary lymphoepithelioma-like carcinoma (PLELC) is an Epstein-Barr virus (EBV)-related, rare subtype of non-small-cell lung cancer (NSCLC). Immune checkpoint inhibitors (ICI) show durable responses in advanced NSCLC. However, their effects and predictive biomarkers in PLELC remain poorly understood. We retrospectively analyzed the data of 48 metastatic PLELC patients treated with ICI. Pretreated paraffin-embedded specimens (n = 19) were stained for PD-1, PD-L1, LAG3, TIM3, CD3, CD4, CD8, CD68, FOXP3, and cytokeratin (CK) by multiple immunohistochemistry (mIHC). Next-generation sequencing was performed for 33 PLELC samples. Among patients treated with ICI monotherapy (n = 30), the objective response rate (ORR), disease control rate (DCR), median progression-free survival (mPFS), and overall survival (mOS) were 13.3%, 80.0%, 7.7 months, and 24.9 months, respectively. Patients with PD-L1 ≥1% showed a longer PFS (8.4 vs. 2.1 months, p = 0.015) relative to those with PD-L1 <1%. Among patients treated with ICI combination therapy (n = 18), ORR, DCR, mPFS, and mOS were 27.8%, 100.0%, 10.1 months, and 19.7 months, respectively. Patients with PD-L1 ≥1% showed a significantly superior OS than those with PD-L1 <1% (NA versus 11.7 months, p = 0.001). Among the 19 mIHC patients, those with high PD-1/PD-L1 and LAG3 expression showed a longer PFS (19.0 vs. 3.9 months, p = 0.003). ICI also showed promising efficacy for treating metastatic PLELC. PD-L1 may be both predictive of ICI treatment efficacy and prognostic for survival in PLELC. PD-1/PD-L1 combined with LAG3 may serve as a predictor of ICI treatment effectiveness in PLELC. Larger and prospective trials are warranted to validate both ICI activity and predictive biomarkers in PLELC. This study was partly presented as a poster at the IASLC 20th World Conference on Lung Cancer 2019, 7-10 September 2019, Barcelona, Spain.


Asunto(s)
Antineoplásicos Inmunológicos , Carcinoma de Pulmón de Células no Pequeñas , Carcinoma de Células Escamosas , Infecciones por Virus de Epstein-Barr , Neoplasias Pulmonares , Humanos , Antígeno B7-H1 , Carcinoma de Pulmón de Células no Pequeñas/patología , Neoplasias Pulmonares/patología , Receptor de Muerte Celular Programada 1 , Inhibidores de Puntos de Control Inmunológico/uso terapéutico , Receptor 2 Celular del Virus de la Hepatitis A , Antineoplásicos Inmunológicos/uso terapéutico , Estudios Retrospectivos , Infecciones por Virus de Epstein-Barr/tratamiento farmacológico , Estudios Prospectivos , Biomarcadores de Tumor , Herpesvirus Humano 4 , Carcinoma de Células Escamosas/tratamiento farmacológico , Queratinas , Factores de Transcripción Forkhead
2.
Transl Pediatr ; 11(6): 869-881, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35800277

RESUMEN

Background: Vortex formation time (VFT) had been considered a useful marker for assessing diastolic performance. the VFT assessment of diastolic function using four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has not been used in repair of tetralogy of Fallot (rTOF) patient. The aims of this study were as follows: (I) establish reference ranges for VFT measurements in healthy children and adolescents using 4D flow CMR imaging; and (II) analyze VFT parameters to assess diastole dysfunction in rTOF patients group. Methods: We acquired the CMR data was of 62 healthy participants (aged 6-18 years; male: 40, female: 22) and 20 patients with rTOF (aged 10-13 years; male: 15, female: 5) using 4D flow and cine sequence in routine chamber view. The VFT was calculated based on comparison of different algorithms from cine measurements (VFTvolume) and 4D flow measurements (VFTblood). Then, VFT measurements were compared to subject peak filling rate (PFR), age, and cardiac mass using simple linear regression and multiple regression analyses. Data were also categorized according to age for VFT and cardiac functional assessment comparisons between 3 age groups (Group 1: 6-9 years; Group 2: 10-13 years; Group 3: 14-18 years). The correlation of VFT and cardiac function parameters were analyzed in the rTOF group. Results: Normal mean value of VFTvolume and VFTblood were 4.25±0.92 and 3.77±1.11 in healthy children participants. The VFTvolume was correlated with VFTblood (r=0.61, P<0.001). There was a moderately significant correlation between VFTvolume and PFR (r=0.46, P<0.001) and between VFTblood and PFR (r=0.47, P<0.001), age (r=0.41, P=0.002) and left ventricular (LV) mass (r=0.48, P<0.001). Multiple regression analyses demonstrated that VFTvolume was independently associated with PFR (T=2.239; P<0.05) and VFTblood (T=4.361; P<0.001). There was a significant difference in VFTvolume between healthy controls and rTOF patients (5.44±1.93 vs. 4.27±0.88, P=0.018). Conclusions: The VFT measurements showed that the LV that had appropriate space to form the optimal vortex ring in normal children and adolescents aged 6-18 years old. The VFTvolume could potentially be helpful in improving our understanding of LV diastolic dysfunction in rTOF patients.

3.
Front Cardiovasc Med ; 9: 870014, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35795359

RESUMEN

Purpose: This study aimed at exploring the feasibility and reproducibility of CCT for the measurement of Left Atrial (LA) strain and volume compared with transthoracic echocardiography (TTE) in pediatric patients with congenital heart disease (CHD). Materials and Methods: The present study included 43 postoperative patients with CHD (7.39 ± 3.64 years, 56% male) who underwent clinically indicated CCT, and all patients underwent additional TTE on the same day. LA strain and volume parameters were measured by dedicated software. The correlation and agreement of LA strain and volume parameters were assessed using Pearson's correlation coefficient and Bland-Altman analysis. Intra-class correlation coefficients (ICC) were used to assess CCT intra-observer and inter-observer reproducibility. Results: All strain parameters of CCT were lower compared to TTE (reservoir strain: 28.37 ± 6.92 vs. 32.15 ± 8.15, respectively; conduit strain: 21.33 ± 6.46 vs. 24.23 ± 7.75, respectively; booster strain: 7.04 ± 2.74 vs. 7.92 ± 3.56). While the volume parameters of CCT were higher compared to TTE (LAV: 29.60 ± 19.01 vs. 25.66 ± 17.60, respectively; LAVi: 30.36 ± 22.31 vs. 28.63 ± 19.25, respectively). Both LA strain and volume measurements showed good correlation and agreement between the two modalities (r = 0.63-0.87, p < 0.001). CT-derived LA strain and volume measurements showed good intra- and inter-observer reproducibility using prototype software (ICC = 0.78-0.96). Conclusions: CCT was feasible for measuring LA strain and volume with good correlation and high reproducibility as compared with TTE. As a complementary modality, CCT can regard as an accepted method in the evaluation of LA function in pediatric patients with CHD.

4.
Thorac Cancer ; 12(19): 2564-2573, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34490728

RESUMEN

BACKGROUND: Src homology region 2 domain-containing phosphatase 2 (SHP2) is a novel target for Kirsten rat sarcoma oncogene (KRAS) mutant cancer. We retrospectively studied the significance of SHP2 in KRAS mutant non-small cell lung cancer (NSCLC) treated with immunotherapy and its relationship with tumor microenvironment (TME). METHODS: Sixty-one advanced KRAS mutant NSCLC patients who underwent immunotherapy were enrolled. Next-generation sequencing (NGS) was used to profile mutation status. The expression of SHP2, phospho-SHP2 (pSHP2), and programmed death ligand 1 (PD-L1) were analyzed by immunohistochemistry (IHC). Quantitative multiplexed immunofluorescence cytochemistry (mIFC) analysis was conducted to describe the TME. RESULTS: SHP2 was heterogeneously expressed in 32 samples in both tumor cells and immune cells and highly expressed (H-score >10) in 25 (78.1%) samples. The expression levels of SHP2 and pSHP2 were positively correlated. Stromal SHP2 (s-SHP2) was higher in tumors with PD-L1 ≥50% versus PD-L1 <50% (p = 0.039). By quantitative mIFC analysis, the expression of s-SHP2 had positive correlation with CD8, CD4, CD68, and PD-L1 levels in stromal area. Patients with high SHP2 expression made up 100.0% of the partial respond (PR) and 80.0% of the stable disease (SD), whereas 50.0% of the progress disease (PD). High SHP2 expression was associated with longer progression-free survival (PFS) and overall survival (OS) (p < 0.001, p = 0.013). Patients with high expression of both SHP2 and PD-L1 had longer PFS (p < 0.001). CONCLUSION: High SHP2 expression could predict the efficacy of immunotherapy and better survival in advanced KRAS mutant NSCLC. SHP2 may function in both tumor cells and immune cells, warranting further study on the potential diverse effects of SHP2 inhibition in TME.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/genética , Inhibidores de Puntos de Control Inmunológico/farmacología , Inmunoterapia/métodos , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/genética , Proteína Tirosina Fosfatasa no Receptora Tipo 11/genética , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mutación , Proteínas Proto-Oncogénicas p21(ras)/genética , Estudios Retrospectivos , Microambiente Tumoral/efectos de los fármacos , Microambiente Tumoral/genética
5.
J Comput Assist Tomogr ; 45(4): 537-543, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34519452

RESUMEN

OBJECTIVE: We explored the feasibility of cardiac computed tomography (CCT) to evaluate postoperative ventricular function in children with congenital heart disease (CHD) and evaluated the accuracy and reproducibility of CCT using cardiac magnetic resonance (CMR) as a reference. METHODS: Thirty-two postoperative children with CHD (20 boys and 12 girls) who underwent CMR and CCT were enrolled. Left and right ventricular ejection fraction, end-diastolic volume, end-systolic volume, stroke volume, and cardiac index were measured using cardiac function analysis software. Cardiac function data were compared between CMR and CCT. The agreement between the 2 modalities was assessed using a Bland-Altman analysis. Intraclass correlation coefficients were used to assess intraobserver and interobserver reproducibility in CCT functional measurements. RESULTS: All functional parameters showed no significant difference (P > 0.05) and were well-correlated (r > 0.5, P < 0.05) between CMR and CCT. The mean values of all ventricular function parameters in CCT were higher compared with CMR. As indicated by 95% limits of agreement, left ventricular function parameters showed a better level of agreement compared with right ventricular function parameters between the 2 modalities. Intraobserver and interobserver reproducibility were excellent in CCT measurements for all functional parameters (intraclass correlation coefficient > 0.9). CONCLUSIONS: Compared with the criterion standard of CMR, CCT is feasible for assessing postoperative ventricular function with sufficient diagnostic accuracy and reproducibility in children with CHD. In addition to its important role regarding anatomical characterization, CCT is a suitable alternative and convenient follow-up tool that can be used to functional evaluation in children who are intolerant with CMR or have contraindications to CMR.


Asunto(s)
Cardiopatías Congénitas/cirugía , Imagen por Resonancia Magnética/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Disfunción Ventricular/diagnóstico por imagen , Niño , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos
6.
Eur J Radiol ; 142: 109868, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34311155

RESUMEN

PURPOSE: We explored the feasibility and reproducibility of cardiac computed tomography (CCT)-derived left ventricular (LV) global strain in postoperative childrenwith congenital heart disease (CHD) and compared its correlation and agreement with transthoracic echocardiography (TTE). METHODS: Fifty-one patients (28 males, 23 females) were included who underwent clinically indicated retrospective electrocardiography-triggered CCT. and all patients underwent additional TTE on the same day. LV global longitudinal strain (GLS), global circumferential strain (GCS), and global radial strain (GRS) were measured. Correlations of global strains between CCT and TTE were assessed using Pearson's correlation coefficient. Intra-class correlation coefficients (ICC) were used to assess CCT intra-observer and inter-observer reproducibility. RESULTS: GLS and GCS were not significantly different between CCT and TTE (GLS: -23.54 ± 3.24 vs. -23.85 ± 3.72, respectively, p = 0.415; GCS: -28.21 ± 3.55 vs. -28.79 ± 3.69, respectively, p = 0.155). GRS was significantly different between CCT and TTE (60.79 ± 15.11 vs. 41.73 ± 4.27, respectively, p < 0.001). There was good correlation between CCT- and TTE-derived GLS (r = 0.70, p < 0.001) and GCS (r = 0.68, p < 0.001), but GRS showed no correlation between CCT and TTE (r = 0.09, p = 0.54). CCT-derived global strain showed good intra- and inter-observer reproducibility (ICC = 0.86-0.92), except the inter-observer reproducibility for GRS (ICC = 0.77). CONCLUSIONS: CCT was feasible for postoperative evaluation of LV global strain in pediatric patients with CHD with sufficient reproducibility. CCT-derived global strain can provide additional information in selected CHD patients with poor acoustic windows and who are intolerant to or have contraindications for cardiac magnetic resonance.


Asunto(s)
Cardiopatías Congénitas , Disfunción Ventricular Izquierda , Niño , Ecocardiografía , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos , Tomografía , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
7.
Korean J Radiol ; 22(8): 1397-1415, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33987995

RESUMEN

The use of pediatric cardiothoracic CT for congenital heart disease (CHD) was traditionally limited to the morphologic evaluation of the extracardiac thoracic vessels, lungs, and airways. Currently, the applications of CT have increased, owing to technological advancements in hardware and software as well as several dose-reduction measures. In the previously published part 1 of the guideline by the Asian Society of Cardiovascular Imaging Congenital Heart Disease Study Group, we reviewed the prerequisite technical knowledge for clinical applications in a user-friendly and vendor-specific manner. Herein, we present the second part of our guideline on contemporary clinical applications of pediatric cardiothoracic CT for CHD based on the consensus of experts from the Asian Society of Cardiovascular Imaging CHD Study Group. This guideline describes up-to-date clinical applications effectively in a systematic fashion.


Asunto(s)
Cardiopatías Congénitas , Niño , Consenso , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Tomografía Computarizada por Rayos X
8.
Int J Cardiovasc Imaging ; 37(7): 2303-2310, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33656630

RESUMEN

The aim of this study is to explore the feasibility of using a non-sedation protocol for the evaluation of neonatal congenital heart disease by using 16-cm wide-detector CT with a low radiation dose. Thirty-four neonates (group 1) were enrolled to undergo cardiac CT without sedation between August 2018 and March 2019. The control group (group 2) comprising 20 inpatient neonates was sedated. Cardiac CT was performed using 16-cm area detector 320-row CT with free breathing and prospective ECG-triggering scan mode. The examination completion time, radiation dose, and image quality were compared between the groups. The results of cardiac CT for patients in group 1 who underwent surgery were compared with surgical findings. Intergroup differences in body weight, age, examination completion time, radiation dose, and image quality evaluation were not significant. There was no significant difference in oxygen saturation before and after the examination in group 1. In all, 98 separate cardiovascular abnormalities in 27 group 1 patients were confirmed using surgical reports. The overall sensitivity, specificity, positive predictive value, and negative predictive value of cardiac CT were 94.90%, 100.0%, 100.0%, and 98.53%. The non-sedation protocol can be applied in neonates with congenital heart disease by using 16-cm wide-detector CT with a low radiation dose. Based on the image quality obtained, non-sedative examination did not extend the examination completion time and helped avoid the possible side effects of sedative drugs.


Asunto(s)
Cardiopatías Congénitas , Tomografía Computarizada por Rayos X , Niño , Angiografía Coronaria , Estudios de Factibilidad , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Humanos , Recién Nacido , Valor Predictivo de las Pruebas , Estudios Prospectivos , Dosis de Radiación
9.
Quant Imaging Med Surg ; 10(2): 485-495, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32190573

RESUMEN

BACKGROUND: This study aimed to investigate the associations between cardiac strain, cardiac torsion, ventricular volumes, and ventricular ejection fraction, with N-terminal pro-B-type natriuretic peptide (NT-proBNP) levels in Fontan patients who were age- and gender-matched with healthy control subjects. METHODS: Cardiovascular magnetic resonance (CMR) studies performed in 22 (15 male, 7 female) patients with single-ventricle physiology (all morphological left ventricles) palliated with Fontan and 17 (10 male, 7 female) age- and gender-matched healthy children volunteers were retrospectively analyzed. Serum NT-proBNP levels were obtained in Fontan subjects. Standard post-processing of CMR images included systemic ventricular end-diastolic and end-systolic volumes, stroke volume, cardiac mass, atrioventricular regurgitation, and ejection fraction. CMR tissue tracking (TT) software was used to quantify global longitudinal strain (GLS), global radial strain (GRS), and global circumferential strain (GCS) and torsion of the systemic ventricle. Pearson and Spearman correlation coefficients were used in comparisons of correlations between NT-proBNP and functional parameters in repair Fontan patients. Intra-observer and inter-observer variability of CMR strain and torsion values were determined from 10 randomly selected Fontan subjects and 10 randomly selected control subjects. RESULTS: GLS was significantly lower in Fontan patients than in control subjects (-15.19±2.94 vs. -19.97±1.70; P<0.001). GLS was not significantly different between normal NT-proBNP levels and high NT-proBNP levels in Fontan patients (-15.59±2.72 vs. -14.62±3.32; P=0.462). The GCS of repair Fontan patients was not significantly lower than that of the control group (-16.76±3.27 vs. -17.88±2.26; P=0.235). GCS was significantly different between normal and high NT-proBNP levels group in Fontan patients (-17.95±2.43 vs. -15.04±3.67; P=0.036). The peak systolic torsion and peak systolic torsion rates were significantly lower in Fontan patients than in control subjects (0.81±0.41 vs. 1.07±0.36, P=0.044; 7.36±3.41 vs. 9.85±2.61, P=0.017). Peak systolic torsion was significantly lower in Fontan patients with normal NT-proBNP levels than in high NT-proBNP subjects (0.67±0.43 vs. 1.01±0.29; P=0.036). GCS and torsion were more strongly correlated with NT-proBNP in the patient group (r=0.541 for GCS; r=0.588 for torsion, P<0.01). The parameters of strain and torsion could be reproduced with sufficient accuracy by intra-observer agreement(biases =0.04 for GLS; biases =0.66 for GCS; biases =1.03 for GRS; biases =0.04 for torsion) and inter-observer agreement (biases =0.32 for GLS; biases =0.85 for GCS; biases =1.52 for GRS; biases =0.18 for torsion). CONCLUSIONS: GLS is an earlier marker of contractile dysfunction in repair Fontan patients. Peak systolic torsion may be a biomarker for determining subclinical dysfunction, as it is more strongly correlated with serum biomarkers of ventricular function than ventricular size or ejection fraction.

10.
J Magn Reson Imaging ; 52(1): 129-138, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31975534

RESUMEN

BACKGROUND: Right ventricular dilation and dysfunction is a common long-term complication in patients with repaired pulmonary stenosis (rPS). Additionally, abnormal right and left ventricular interactions have been reported in right-sided heart defect after intervention, including in pulmonary stenosis. PURPOSE: To analyze ventricular strain, remodeling, and left and right ventricular interactions in rPS patients with preserved right ventricular ejection fraction (RVEF) compared with healthy children using cardiac magnetic resonance. STUDY TYPE: A cross-sectional study. POPULATION: In all, 34 rPS patients and 10 healthy children volunteers (controls). FIELD STRENGTH/SEQUENCE: 3.0T/2D balanced steady-state free precession (2D b-SSFP) cine, late gadolinium enhancement (LGE), and 2D phase contrast (2D-PC). ASSESSMENT: Pulmonary regurgitation (PR) fractions of the main pulmonary artery, biventricular volumes, masses, function, and cardiac strain. STATISTICAL TESTS: Mann-Whitney U-test, t-test, Pearson correlation coefficients, Spearman's correlation coefficients, and intraclass correlation coefficients analysis were performed. RESULTS: For group analysis, the right ventricular (RV) global circumferential strain and radial strain were significantly increased in patients when compared with controls (-13.57 ± 2.69 vs. -5.91 ± 3.16, P < 0.001; 25.31 ± 8.12 vs. 9.87 ± 5.32, P < 0.001, respectively). The fraction of PR displayed moderate correlation with right ventricular end-diastolic volume index (RVEDVi) (r = 0.452, P = 0.022). RVEDVi and mass index were larger in patients vs. control (104.92 ± 27.46 vs. 85.15 ± 11.98, P = 0.016; 18.28 ± 4.95g/m2 vs. 11.67 ± 2.14 g/m2 , P < 0.001, respectively). Patients presented with preserved left ventricular ejection function, but was lower than healthy controls (60.89% ± 4.89% vs. 65.95% ± 4.56%, P = 0.006). Regional circumferential strain of segment 3 of left ventricle (LV) were significantly decreased in patients (-7.79 ± 6.52 vs. -13.56 ± 3.22, P = 0.003). DATA CONCLUSION: Compensated increased RV strain, myocardial remodeling of RV, and adverse right and left ventricular interactions occur in rPS patients with preserved RVEF. The decreased interventricular septum strain may lead to impaired LV function due to RV dilation as a result of PR. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 3 J. Magn. Reson. Imaging 2020;52:129-138.


Asunto(s)
Ventrículos Cardíacos , Estenosis de la Válvula Pulmonar , Tetralogía de Fallot , Disfunción Ventricular Derecha , Niño , Medios de Contraste , Estudios Transversales , Gadolinio , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/cirugía , Volumen Sistólico , Disfunción Ventricular Derecha/diagnóstico por imagen , Función Ventricular Derecha
11.
BMC Med Imaging ; 19(1): 97, 2019 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-31847826

RESUMEN

BACKGROUND: Abernethy malformation is a rare congenital abnormality. Imaging examination is an important method for the diagnosis. The purpose of this study was to demonstrate manifestations of multi-slice computed tomography (MSCT) in Abernethy malformation and its diagnostic accuracy. METHODS: Fourteen children with Abernethy malformation were admitted to our center in China between July 2011 and January 2018. All 14 patients (eight males and six females) received MSCT and digital subtraction angiography (DSA) while eight patients also received ultrasound. The patients' age ranged from 1 to 14 (median age 8 years old). The clinical records of the patients were retrospectively reviewed. MSCT raw data were transferred to an Advantage Windows 4.2 or 4.6 workstation (General Electric Medical Systems, Waukesha, WI). We compared the findings of MSCT with DSA and surgical results in order to ascertain diagnostic accuracy. RESULTS: Three cases had type Ib Abernethy malformation and eleven cases had type II. Two cases of type II Abernethy malformation were misdiagnosed as type Ib using MSCT. Comparing the findings of MSCT with DSA and surgical results, the accuracy of MSCT was 85.7% (12/14), in which 100.0% (3/3) were type Ib and 81.8% (9/11) were type II. Clinical information included congenital heart disease, pulmonary hypertension, diffuse pulmonary arteriovenous fistula, abnormal liver function, hepatic nodules, elevated blood ammonia, and hepatic encephalopathy. Eleven cases were treated after diagnosis. One patient with Abernethy malformation type Ib (1/3) underwent liver transplantation. Seven patients with Abernethy malformation type II (7/11) were treated by shunt occlusion, received laparoscopy, or were treated with open surgical ligation. Another three patients (3/11) with Abernethy malformation type II were treated by interventional portocaval shunt occlusion under DSA. CONCLUSION: MSCT attains excellent capability in diagnosing type II Abernethy malformation and further shows the location of the portocaval shunt. DSA can help when it is hard to determine diagnosis between Abernethy type Ib and II using MSCT.


Asunto(s)
Sistema Porta/anomalías , Malformaciones Vasculares/diagnóstico por imagen , Adolescente , Angiografía de Substracción Digital , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Sistema Porta/diagnóstico por imagen , Sistema Porta/cirugía , Estudios Retrospectivos , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X , Malformaciones Vasculares/cirugía
13.
Echocardiography ; 36(1): 133-141, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30515879

RESUMEN

BACKGROUND: Challenges remain in quantitative evaluation of right ventricular (RV) function by echocardiography. Multiple-view assessment is believed to provide a more comprehensive quantification of RV function than conventional single-view analysis. Peak systolic longitudinal RV strain (RVLS) measured by speckle tracking echocardiography (STE) has clinical and prognostic value. No study has investigated RV systolic function in the repaired tetralogy of Fallot (rTOF) using a standardized four-view iRotate model from one apical view. Herein, we examined the feasibility and accuracy of the four-view analysis from apical window in quantitation of RVLS among children with rTOF. METHODS: Thirty-seven children with rTOF and 37 age- and gender-matched controls were prospectively enrolled. Tricuspid annular plane systolic excursion (TAPSE) and tricuspid annular peak systolic velocity (TDI-S' ) and fractional area change(FAC) were obtained. RVLS of four free-walls were analyzed by dedicated RV speckle tracking software. Echocardiographic parameters were compared with the right ventricular ejection fraction (RVEF) measured by the cardiac magnetic resonance (CMR) in children with rTOF. RESULTS: Multi-view RVLS analysis from apical window was feasible in 35 children with rTOF and all the controls. Compared with age- and gender-matched controls, RVLS of the anterior, lateral, inferior-a, and inferior-b walls were significantly reduced in children with rTOF (P < 0.001). RVLS of the anterior, lateral, inferior-a, and inferior-b walls correlated well with CMR-RVEF in children with rTOF (r = -0.667, -0.743, -0.808, -0.695, P < 0.001). CONCLUSIONS: Multi-view analysis of RVLS from apical window can be applied to evaluate the RV function in children with rTOF. RVLS of the inferior wall-a in the aortic view is a novel and accurate indicator of RV function because of its good reproducibility and strong correlation with CMR-RVEF.


Asunto(s)
Ecocardiografía/métodos , Complicaciones Posoperatorias/diagnóstico por imagen , Tetralogía de Fallot/cirugía , Disfunción Ventricular Derecha/diagnóstico por imagen , Preescolar , Estudios de Factibilidad , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Lactante , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados , Disfunción Ventricular Derecha/fisiopatología , Función Ventricular Derecha/fisiología
14.
Indian J Pediatr ; 85(9): 729-737, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29313307

RESUMEN

OBJECTIVE: To examine the features of cardiac rhabdomyomas and tuberous sclerosis in fetuses and infants using magnetic resonance imaging (MRI) and to determine whether MRI is an effective tool to facilitate early detection of tuberous sclerosis complex (TSC). METHODS: Fifteen patients with TSC were evaluated by ultrafast or standard MRI between June 2005 and September 2016. Fifteen patients were divided into two groups. Group A included five cases in utero and followed in infancy with gestational ages from 26 + 1 to 38 + 2 wk. Group B included ten cases aged from 36 d to 18-mo-old. RESULTS: There were 11 and 10 cardiac lesions of prenatal and postnatal period respectively in five subjects of Group A and 27 cardiac lesions in ten subjects of Group B. There were more than 31 prenatal brain lesions and 30 postnatal brain lesions in Group A and 169 lesions in Group B. Standard postnatal brain MRI confirmed the prenatal study of Group A. At 1 y follow up of Group A, there was partial regression of 2 cardiac lesions, complete regression of 1 cardiac lesion, no obvious regression of 8 cardiac lesions. CONCLUSIONS: When one or multiple cardiac tumors are detected by ultrasound in fetal period or some specific clinical manifestations are presented in infancy, fetal ultrafast MRI or standard MRI is suggested to make early diagnosis of TSC.


Asunto(s)
Neoplasias Cardíacas/diagnóstico por imagen , Diagnóstico Prenatal , Rabdomioma/diagnóstico por imagen , Esclerosis Tuberosa/diagnóstico por imagen , Preescolar , Femenino , Humanos , Lactante , Imagen por Resonancia Magnética , Embarazo , Estudios Retrospectivos
15.
J Comput Assist Tomogr ; 41(6): 983-989, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28448421

RESUMEN

OBJECTIVE: The aim of this study was to present relationship between partial anomalous left pulmonary artery (PALPA) and the tracheobronchial tree and patterns of the tracheobronchial tree assessed by multislice computed tomography (MSCT). METHODS: Nine patients were assessed by MSCT. The relationships between the tracheobronchial tree and PALPA and different tracheobronchial patterns, location of tracheobronchial stenosis, severity of stenosis, and associated cardiac defects were evaluated. The results of MSCT for these patients were compared with the operative findings. RESULTS: The anatomy of PALPA was clearly identified by MSCT in all 9 patients. Three relationships between PALPA and the tracheobronchial tree were noted. In addition, 3 patterns of tracheobronchial tree anatomy were also demonstrated. The PALPA arose from the right pulmonary artery, forming a pulmonary sling (n = 2). The PALPA, which arose from the proximal right pulmonary artery, went below the tracheal bifurcation and passed anterior (n = 1) or inferior-anterior (n = 6) to the proximal left main bronchus. Three patterns of the tracheobronchial tree were presented with normal (n = 5), normal pattern with right tracheal bronchus (n = 3), and bridging bronchus (n = 1). The rate of tracheobronchial stenosis was 56% (5/9).Five patients underwent operation, and at that time, the relationship between PALPA and the tracheobronchial tree defined on MSCT was confirmed. CONCLUSIONS: The PALPA can be associated with tracheobronchial anomalies and airway compression depending on its orientation to the airway. Noninvasive imaging modalities such as MSCT will be helpful for making further management decisions.


Asunto(s)
Bronquios/anomalías , Bronquios/diagnóstico por imagen , Tomografía Computarizada Multidetector , Arteria Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen , Tráquea/anomalías , Tráquea/diagnóstico por imagen , Preescolar , Femenino , Humanos , Lactante , Masculino , Estudios Retrospectivos
16.
Br J Radiol ; 90(1070): 20160669, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27925466

RESUMEN

OBJECTIVE: To the assess image quality, contrast dose and radiation dose in cardiac CT in children with congenital heart disease (CHD) using low-concentration iodinated contrast agent and low tube voltage and current in comparison with standard dose protocol. METHODS: 110 patients with CHD were randomized to 1 of the 2 scan protocols: Group A (n = 45) with 120 mA tube current and contrast agent of 270 mgI/ml in concentration (Visipaque™; GE Healthcare Ireland, Co., Cork, UK); and Group B (n = 65) with the conventional 160 mA and 370 mgI/ml concentration contrast (Iopamiro®; Shanghai Bracco Sine Pharmaceutical Corp Ltd, Shanghai, China). Both groups used 80 kVp tube voltage and were reconstructed with 70% adaptive statistical iterative reconstruction algorithm. The CT value and noise in aortic arch were measured and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A five-point scale was used to subjectively evaluate image quality. Contrast and radiation dose were recorded. RESULTS: There was no difference in age and weight between the two groups (all p > 0.05). The iodine load and radiation dose in Group A were statistically lower (3976 ± 747 mgI vs 5763 ± 1018 mgI in iodine load and 0.60 ± 0.08 mSv vs 0.77 ± 0.10 mSv in effective dose; p < 0.001). However, image noise, CT value, CNR, SNR and subjective image quality for the two groups were similar (all p > 0.05), and with good agreement between the two observers. Comparing the surgery results, the diagnostic accuracy for extracardiac and intracardiac defects for Group A was 96% and 92%, respectively, while the corresponding numbers for Group B were 95% and 93%. CONCLUSION: Compared with the standard dose protocol, the use of low tube voltage (80 kVp), low tube current (120 mA) and low-concentration iodinated contrast agent (270 mgI/ml) enables a reduction of 30% in iodine load and 22% in radiation dose while maintaining compatible image quality and diagnostic accuracy. Advances in knowledge: The new cardiac CT scanning protocol can largely reduce the adverse effects of radiation and contrast media to children. Meanwhile, it also can be used effectively to examine complex CHD.


Asunto(s)
Cardiopatías Congénitas/diagnóstico por imagen , Adolescente , Algoritmos , Niño , Preescolar , Medios de Contraste , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Estudios Prospectivos , Dosis de Radiación , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Ácidos Triyodobenzoicos
17.
Int J Cardiovasc Imaging ; 32(6): 991-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26897005

RESUMEN

To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p < 0.001). The mean CNR and SD were 28.19 ± 13.00 and 15.75 ± 3.61HU, respectively. The image quality scores were 4.31 ± 0.36 and 4.29 ± 0.41 from reviewer 1 and 2 respectively with an excellent agreement between them (Kappa = 0.85). The detection rate for the origins of the left and right coronary arteries was 96 and 90 %, respectively. The detection rates of the origins of left coronary artery and right coronary artery in all cases were 96 % (78/81) and 90 % (73/81), respectively. Twenty cases of conotruncal anomalies and ALCAPA were validated surgically and the accuracy of cardiac CT diagnosis was 95 % (19/20). The overall deformity based sensitivity, specificity, positive predictive value and negative predictive value were 94.0.1, 99.9, 98.6, 99.5 % respectively, by CCT, and 88.2, 99.9, 97.8, 99.0 %, respectively, by echocardiography. Prospective ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Electrocardiografía , Cardiopatías Congénitas/diagnóstico por imagen , Tomografía Computarizada Multidetector , Dosis de Radiación , Exposición a la Radiación , Factores de Edad , Técnicas de Imagen Sincronizada Cardíacas/instrumentación , Angiografía por Tomografía Computarizada/instrumentación , Angiografía Coronaria/instrumentación , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Femenino , Cardiopatías Congénitas/fisiopatología , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Tomografía Computarizada Multidetector/instrumentación , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Tomógrafos Computarizados por Rayos X
18.
Eur Radiol ; 26(1): 138-46, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25994196

RESUMEN

OBJECTIVES: To investigate the feasibility of ultrashort echo time (UTE) magnetic resonance imaging (MRI) for the diagnosis of skull fractures. METHODS: The skull fracture models of ten Bama pigs and 364 patients with craniocerebral trauma were subjected to computed tomography (CT), UTE and conventional MRI sequences. The accuracy of UTE imaging in skull fracture diagnosis was analysed using receiver operating characteristic (ROC) curve analysis, McNemar's test and Kappa values. Differences among CT, UTE imaging and anatomical measurement (AM) values for linear fractures (LFs) and depressed fractures (DFs) were compared using one-way ANOVA and a paired-samples t-test. RESULTS: UTE imaging clearly demonstrated skull structures and fractures. The accuracy, validity and reliability of UTE MRI were excellent, with no significant differences between expert readings (P > 0.05; Kappa, 0.899). The values obtained for 42 LFs and 13 DFs in the ten specimens were not significantly different among CT, UTE MRI and AMs, while those obtained for 55 LFs and ten DFs in 44 patients were not significantly different between CT and UTE MRI (P > 0.05). CONCLUSIONS: UTE MRI sequences are feasible for the evaluation of skull structures and fractures, with no radiation exposure, particularly for paediatric and pregnant patients. KEY POINTS: Despite ionising radiation, CT is standard for skull fracture assessment. Conventional MRI cannot depict skull structures. 3D-UTE sequences clearly demonstrate skull structures and fractures. UTE plus conventional MRI are superior to CT in craniocerebral trauma assessment. Paediatric and pregnant patients will benefit from this imaging modality.


Asunto(s)
Imagen Eco-Planar/métodos , Imagenología Tridimensional/métodos , Fracturas Craneales/diagnóstico , Adolescente , Adulto , Anciano , Animales , Niño , Preescolar , Modelos Animales de Enfermedad , Estudios de Factibilidad , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Curva ROC , Reproducibilidad de los Resultados , Porcinos , Porcinos Enanos , Tomografía Computarizada por Rayos X , Adulto Joven
19.
World J Pediatr ; 11(4): 326-30, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26454437

RESUMEN

BACKGROUND: The clinical management of children with renal tumors including Wilms' tumor, clear cell sarcoma, rhabdoid tumor and other renal tumors in our center was designed according to the National Wilms' Tumor Study Group protocols. METHODS: A total of 142 consecutive patients who had been diagnosed as having renal tumors at Shanghai Children's Medical Center were reviewed retrospectively in the period of December 1998 and September 2012. Diagnosis and treatment were decided by a multidisciplinary team including oncologists, surgeons, pathologists and sub-specialized radiologists. RESULTS: The median age of the patients at the time of diagnosis was 27 months. The tumor stages of the patients were as follows: stage I 24.6%, stage II 23.2%, stage III 32.3%, stage IV 14.1%, and stage V 5.6%. Favorable histology was diagnosed in 80.3%, anaplasia in 4.2%, clear cell sarcoma in 9.8%, rhabdoid tumor in 4.9%, and other renal tumors in 0.7% of the patients. The event-free and overall 5-year survival rates were 80% and 83%, respectively. Tumor relapse and progress was seen in 25 patients (17.6%). The median relapse time was 6 months (range: 2-37 months). Seven relapsing patients were retreated and four of them got second complete remission (three in stage II, one in stage I). CONCLUSION: A multi-disciplinary team work model is feasible in developing countries, and the renal tumors protocols basically from developed countries are safe in developing countries.


Asunto(s)
Neoplasias Renales/terapia , Adolescente , Niño , Preescolar , China/epidemiología , Terapia Combinada , Países en Desarrollo , Diagnóstico por Imagen , Femenino , Humanos , Lactante , Neoplasias Renales/epidemiología , Neoplasias Renales/patología , Masculino , Estadificación de Neoplasias , Grupo de Atención al Paciente , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
20.
Pediatr Radiol ; 44(7): 803-9, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24706163

RESUMEN

BACKGROUND: Absent pulmonary valve is a rare cardiovascular anomaly that can result in profound tracheobronchial compression. OBJECTIVE: To demonstrate the advantage of multi-slice CT in diagnosing tracheobronchial compression, its severity as related to the adjacent dilated pulmonary arteries, and associated lung and cardiac lesions. MATERIALS AND METHODS: We included children with absent pulmonary valve who were reviewed by multi-slice CT during a 17-year period. The number and locations of stenoses and lung lesions were noted and the severity of stenosis was categorized. The diameter of the pulmonary artery was measured and associated cardiac defects were demonstrated. RESULTS: Thirty-one children (14 girls and 17 boys) were included. Of these, 29 had ventricular septal defect and 2 had an intact ventricular septum. Twenty-nine children (94%) had tracheobronchial compression, judged to be mild in nine children (31%), moderate in 10 (34%) and severe in 10 (34%). The different locations of the stenosis (carina, main bronchi, lobar and segmental bronchi) were observed. And the number and location of lung lesions demonstrated that the right middle and left upper and lower lobes were often affected. The diameter of the pulmonary artery in these children was well above normal published values, and Spearman rank correlation analysis showed a correlation between the size of the pulmonary artery and the severity of the tracheobronchial stenosis. Nineteen children (61%) underwent surgery and 4 of these children had a multi-slice CT post-operative follow-up study. CONCLUSION: Absent pulmonary valve can cause significant morbidity and mortality in children. Multi-slice CT can accurately depict areas of tracheobronchial compression, associated lung lesions and cardiac defects, helping to direct the surgeon.


Asunto(s)
Enfermedades Bronquiales/diagnóstico por imagen , Tomografía Computarizada Multidetector , Válvula Pulmonar/anomalías , Estenosis Traqueal/diagnóstico por imagen , Enfermedades Bronquiales/etiología , Niño , Preescolar , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/etiología , Femenino , Cardiopatías Congénitas/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Lactante , Recién Nacido , Masculino , Arteria Pulmonar/diagnóstico por imagen , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Estenosis Traqueal/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...