Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Life Sci ; 349: 122718, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38754815

RESUMEN

Chronic obstructive pulmonary disease (COPD) is projected to become the third leading cause of death globally by 2030. Despite the limited treatment options available for advanced COPD, which are mostly restricted to costly lung transplants, physical ablation therapy offers promising alternatives. This technique focuses on ablating lesioned airway epithelium, reducing secretions and obstructions, and promoting normal epithelial regeneration, demonstrating significant therapeutic potential. Physical ablation therapy primarily involves thermal steam ablation, cryoablation, targeted lung denervation, and high-voltage pulsed electric field ablation. These methods help transform the hypersecretory phenotype, alleviate airway inflammation, and decrease the volume of emphysematous lung segments by targeting goblet cells and damaged lung areas. Compared to traditional treatments, endoscopic physical ablation offers fewer injuries, quicker recovery, and enhanced safety. However, its application in COPD remains limited due to inconsistent clinical outcomes, a lack of well-understood mechanisms, and the absence of standardized guidelines. This review begins by exploring the development of these ablation techniques and their current clinical uses in COPD treatment. It then delves into the therapeutic effects reported in recent clinical studies and discusses the underlying mechanisms. Finally, the review assesses the future prospects and challenges of employing ablation technology in COPD clinical practice, aiming to provide a practical reference and a theoretical basis for its use and inspire further research.


Asunto(s)
Técnicas de Ablación , Enfermedad Pulmonar Obstructiva Crónica , Enfermedad Pulmonar Obstructiva Crónica/terapia , Enfermedad Pulmonar Obstructiva Crónica/cirugía , Humanos , Técnicas de Ablación/métodos , Pulmón , Animales
2.
Bioelectrochemistry ; 158: 108726, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38733722

RESUMEN

Mucus hypersecretion resulting from excessive proliferation and metaplasia of goblet cells in the airways is the pathological foundation for Chronic obstructive pulmonary disease (COPD). Clinical trials have confirmed the clinical efficacy of pulsed electric field ablation (PFA) for COPD, but its underlying mechanisms is poorly understood. Cellular and animal models of COPD (rich in goblet cells) were established in this study to detect goblet cells' sensitivity to PFA. Schwan's equation was adopted to calculate the cells' transmembrane potential and the electroporation areas in the cell membrane. We found that goblet cells are more sensitive to low-intensity PFA (250 V/cm-500 V/cm) than BEAS-2B cells. It is attributed to the larger size of goblet cells, which allows a stronger transmembrane potential formation under the same electric field strength. Additionally, the transmembrane potential of larger-sized cells can reach the cell membrane electroporation threshold in more areas. Trypan blue staining confirmed that the cells underwent IRE rate was higher in goblet cells than in BEAS-2B cells. Animal experiments also confirmed that the airway epithelium of COPD is more sensitive to PFA. We conclude that lower-intensity PFA can selectively kill goblet cells in the COPD airway epithelium, ultimately achieving the therapeutic effect of treating COPD.


Asunto(s)
Electroporación , Células Caliciformes , Enfermedad Pulmonar Obstructiva Crónica , Células Caliciformes/patología , Enfermedad Pulmonar Obstructiva Crónica/patología , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/terapia , Animales , Humanos , Electroporación/métodos , Línea Celular , Potenciales de la Membrana , Masculino , Técnicas de Ablación/métodos , Electricidad , Ratones
3.
BMC Gastroenterol ; 22(1): 12, 2022 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-34996384

RESUMEN

BACKGROUND: X-ray cholangiography is of great value in the imaging of biliary tract diseases; however, occupational radiation exposure is unavoidable. Moreover, clinicians must manually inject the contrast dye, which may result in a relatively high incidence of adverse reactions due to unstable injection pressure. Thus, there is a need to develop a novel remote-controlled cholangiography injection device. METHODS: Patients with external biliary drainage requiring cholangiography were included. A remote-controlled injection device was developed with three major components: an injection pump, a pressure sensor, and a wireless remote-control panel. Image quality, adverse reactions, and radiation dose were evaluated. RESULTS: Different kinds of X-ray cholangiography were successfully and smoothly performed using this remote-controlled injection device in all patients. The incidence of adverse reactions in the device group was significantly lower than that in the manual group (4.17% vs. 13.9%, P = 0.001), and increasing the injection pressure increased the incidence of adverse reactions. In addition, the device helped operators avoid ionizing radiation completely. CONCLUSIONS: With good control of injection pressure (within 10 kPa), the remote-controlled cholangiography injection device could replace the need for the doctor to inject contrast agent with good security and effectivity. It is expected to be submitted for clinical application.


Asunto(s)
Enfermedades de las Vías Biliares , Colangiografía , China , Medios de Contraste/efectos adversos , Drenaje , Humanos
4.
Zhongguo Yi Liao Qi Xie Za Zhi ; 45(1): 22-25, 2021 Feb 08.
Artículo en Chino | MEDLINE | ID: mdl-33522171

RESUMEN

OBJECTIVE: In the context of coronavirus disease 2019 (COVID-19) pandemic, the subject was designed to develop a new tracheal intubation device based on magnetic navigation technology to improve the success rate of tracheal intubation and reduce the risk of occupational exposure of medical staff. METHODS: The new tracheal intubation device was designed with the uniqueness of the magnetic field environment and magnetic steering of magnetic navigation technology. And preliminary magnetic navigation tracheal intubation experiments were performed on the tracheal intubation simulator. RESULTS: Magnetic navigation tracheal intubation can successfully implement tracheal intubation, and the time required is lower than that of traditional laryngoscopy. CONCLUSIONS: The tracheal intubation based on magnetic navigation technology is feasible, with high efficiency and easy operation. That is expected to be widely used for tracheal intubation during treatment of patients outside the hospital in the future. At the same time, magnetic navigation endotracheal intubation technology will be the key technology for the development of endotracheal intubation robots.


Asunto(s)
COVID-19 , COVID-19/terapia , Diseño de Equipo , Estudios de Factibilidad , Humanos , Intubación Intratraqueal , Fenómenos Magnéticos , SARS-CoV-2 , Tecnología
5.
World J Gastroenterol ; 26(42): 6614-6625, 2020 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-33268950

RESUMEN

BACKGROUND: Although previous studies have confirmed the feasibility of magnetic compression anastomosis (MCA), there is still a risk of long-term anastomotic stenosis. For traditional MCA devices, a large device is associated with great pressure, and eventually increased leakage. AIM: To develop a novel MCA device to simultaneously meet the requirements of pressure and size. METHODS: Traditional nummular MCA devices of all possible sizes were used to conduct ileac anastomosis in rats. The mean (± SD) circumference of the ileum was 13.34 ± 0.12 mm. Based on short- and long-term follow-up results, we determined the appropriate pressure range and minimum size. Thereafter, we introduced a novel "fedora-type" MCA device, which entailed the use of a nummular magnet with a larger sheet metal. RESULTS: With traditional MCA devices, the anastomoses experienced stenosis and even closure during the long-term follow-up when the anastomat was smaller than Φ5 mm. However, the risk of leakage increased when it was larger than Φ4 mm. On comparison of the different designs, it was found that the "fedora-type" MCA device should be composed of a Φ4-mm nummular magnet with a Φ6-mm sheet metal. CONCLUSION: The diameter of the MCA device should be greater than 120% of the enteric diameter. The novel "fedora-type" MCA device controls the pressure and optimizes the size.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Digestivo , Anastomosis Quirúrgica , Animales , Intestinos/cirugía , Fenómenos Magnéticos , Magnetismo , Ratas
6.
World J Surg ; 44(4): 1062-1069, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31776650

RESUMEN

INTRODUCTION: Difficulties with liver transplantation (LT)-related surgical techniques are great challenges for young surgeons. Thus, young surgeons need to undergo systematic preclinical training. However, an optimal training system for LT is still lacking. This study aims to evaluate the safety and educational value of the Magnetic Spiderman (MS) during LT-related surgical techniques training, particularly during training for the preparation of the donor's liver and vascular reconstruction. METHODS: For the donor liver preparation training, the pulling force of the MS was measured using 16 porcine livers. Another 40 porcine livers were divided into two groups: MS group (used MS in the preparation of the liver) (n = 25) and manual group (took manual assistance in the preparation of the liver) (MA group, n = 15). In vascular reconstruction training, 25 pairs of porcine iliac veins were used to practice reconstruction. Five LT experts evaluated the MS for its use in LT-related surgical techniques training. RESULTS: During the donor liver preparation training, the number of assistants required in the MS group was significantly less than the number required in the MA group (0 vs. 1.8 ± 0.1; P < 0.001). However, the number of vasculature leaking points was similar between the two groups (0.2 ± 0.1 vs. 0.4 ± 0.2; P = 0.51). In vascular reconstruction training, the trainee alone could complete the vascular reconstruction training, with a reconstruction success rate of 80% (20/25). All five experts considered the MS a viable alternative to assistants, with the ability to facilitate single surgeon training for LT. Four out of five (80%) experts considered MS quite safe for surgery and effective at keeping the surgical field clear. CONCLUSION: MS can reduce the number of assistants to zero in LT-related techniques training without increasing the risk of the operation, thus facilitating training for LT.


Asunto(s)
Trasplante de Hígado/educación , Cirujanos/educación , Animales , Trasplante de Hígado/instrumentación , Procedimientos de Cirugía Plástica/educación , Porcinos
7.
Environ Toxicol Pharmacol ; 72: 103248, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31494514

RESUMEN

The characteristics of the PM2.5 concentration in surgical smoke produced by operating on different human tissues during hemihepatectomy were explored to provide a reference for protective measures. Our results showed that the highest concentration of PM2.5 produced by the electrosurgical knife was the liver tissue, followed by muscle, adipose, and vascular tissue. When the single-layer disposable medical mask, double-layer disposable medical mask, and surgical particulate respirator were used to cover the sampling port of the detector, the PM2.5 concentration for all tissue types could be reduced by approximately 40%, 55% and 75%, respectively. In the liver, the average concentration of PM2.5 produced by the ultrasonic scalpel was approximately twice that produced by the electrosurgical knife, suggesting that the air pollution around the chief surgeon caused by the ultrasonic scalpel is more serious than that caused by the electrosurgical knife. Much more protective work should be given for the liver-related surgery.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Hepatectomía , Exposición Profesional/análisis , Material Particulado/análisis , Tejido Adiposo/química , Adulto , Anciano , Electrocirugia/instrumentación , Femenino , Hepatectomía/instrumentación , Humanos , Hígado/química , Hígado/cirugía , Trasplante de Hígado , Masculino , Persona de Mediana Edad , Músculos/química , Exposición Profesional/prevención & control , Procedimientos Quirúrgicos Ultrasónicos/instrumentación , Ventiladores Mecánicos
8.
Sci Rep ; 9(1): 11947, 2019 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-31420571

RESUMEN

Biliary tract infection (BTI)-derived sepsis remains a serious problem with significant morbidity and mortality in the modern era of critical care management. Current animal models of BTI have relied mostly on injecting purified bacteria or their toxins into the biliary tract. These models do not fully reflect pathophysiology or disease processes of clinical cholangitis or cholecystitis. In the current study, we developed a novel model of BTI by performing cholecystocolonic anastomosis (CCA) in rabbits and characterized pathophysiologic changes in this model. This model is intended to mimic the clinical process of cholecystocolonic fistula with reflux cholangitis, a severe form of BTI. Adult male rabbits were subjected to BTI-derived sepsis through an anastomosis of the gall bladder to the colon (i.e., CCA). The animals were monitored for 7 days to record survival. In additional groups of animals, various bacterial, hemodynamic, histological and biochemical parameters were measured at 12, 24, 48 and 72 h after CCA. The anastomosis between the gallbladder and the colon required about 5-8 min to finish. The median survival time for rabbits after CCA was 96 h. The positive rates of bacterial culture at 72 h after CCA were 83.3% and 100% in the blood and liver, respectively. The most common microorganism was Escherichia coli followed by Enterococcus. Plasma Tumor Necrosis Factor-α (TNF-α), Lnterleukin-10 (IL-10), Lnterleukin-6 (IL-6), and High-mobility group box 1 protein (HMGB-1) levels were greatly elevated after CCA. The cardiac index and heart rate increased slightly at 12 h after CCA and then continued to decrease. Systemic hypotension developed 48 h after CCA. Histological studies showed reflux cholangitis with acute lung and kidney injury. Cholecystocolonic anastomosis produces polymicrobial sepsis in rabbits, which mimics many aspects of human BTI-derived sepsis. It is reproducible and easy to perform and may serve as an excellent model for future sepsis research.


Asunto(s)
Anastomosis Quirúrgica/efectos adversos , Bacteriemia/patología , Colangitis/patología , Colecistitis/patología , Modelos Animales de Enfermedad , Sepsis/patología , Anastomosis Quirúrgica/métodos , Animales , Bacteriemia/etiología , Bacteriemia/microbiología , Biomarcadores/metabolismo , Colangitis/etiología , Colangitis/microbiología , Colecistitis/etiología , Colecistitis/microbiología , Colon/microbiología , Colon/cirugía , Enterococcus/crecimiento & desarrollo , Enterococcus/patogenicidad , Escherichia coli/crecimiento & desarrollo , Escherichia coli/patogenicidad , Vesícula Biliar/microbiología , Vesícula Biliar/cirugía , Proteína HMGB1/metabolismo , Humanos , Interleucina-10/metabolismo , Interleucina-6/metabolismo , Riñón/microbiología , Riñón/patología , Hígado/microbiología , Hígado/patología , Pulmón/microbiología , Pulmón/patología , Masculino , Conejos , Sepsis/etiología , Sepsis/microbiología , Factor de Necrosis Tumoral alfa/metabolismo
9.
Lasers Surg Med ; 51(8): 720-726, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31090100

RESUMEN

BACKGROUND AND OBJECTIVE: Despite the successful application of laser in animal experiments and clinics, the adjustment of laser parameters during surgery is still unclear. This study aimed to investigate the effect of different 980-nm diode laser parameters in hepatectomy. This could provide a clear protocol for using 980-nm diode laser in hepatectomy. STUDY DESIGN/MATERIALS AND METHODS: In total, 48 Sprague-Dawley rats were used to explore the effects of different 980-nm diode laser parameters in hepatectomy, by setting different parameter combinations. The rats were randomly divided into eight groups, including the continuous wave group and quasi-continuous wave group. The effects were assessed in terms of liver resection speed, extent of intraoperative bleeding, and thermal damage. RESULTS: In the quasi-continuous wave group, there was a significant difference in resection speed at the different laser parameters (P < 0.001); however, there was no significant difference in intraoperative bleeding and thermal damage. In the continuous wave group, there was a significant difference in resection speed, intraoperative bleeding, and thermal damage at different parameters. CONCLUSION: The study showed that the average power determined hemostasis efficiency and thermal damage, and peak power determined the liver resection speed, whereas the pulse width and repetition frequency are not independent factors. When using 980-nm diode laser in hepatectomy, the average power should be decreased to prove hemostasis efficiency in delicate operations, and the peak power should be decreased to accelerate the procedure without worsening thermal damage. Lasers Surg. Med. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Pérdida de Sangre Quirúrgica/fisiopatología , Hepatectomía/métodos , Terapia por Láser/métodos , Láseres de Semiconductores/uso terapéutico , Hígado/patología , Animales , Biopsia con Aguja , China , Modelos Animales de Enfermedad , Hemostasis Quirúrgica/métodos , Hepatectomía/instrumentación , Inmunohistoquímica , Hígado/cirugía , Masculino , Tempo Operativo , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Sensibilidad y Especificidad
10.
J Surg Res ; 239: 166-172, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30836298

RESUMEN

BACKGROUND: To study the feasibility of laparo-endoscopic single-site (LESS) cholecystectomy through a 10-mm incision using a miniature magnetically anchored and controlled laparoscopy system and a grasper system. METHODS: The miniature magnetically anchored and controlled laparoscopy system consisted of a miniature magnetically anchored camera (MMAC), an external magnetic anchoring unit, and a vision output device. The camera weighed 9.8 g and measured Φ10 mm × 50 mm. The magnetically anchored and controlled grasper system consisted of a magnetically anchored grasper (MAG), an external magnetic anchoring unit, and a push-pull device. The MAG had a titanium alloy clip head and a magnetic tail. The laparoscopy system and grasper system were used simultaneously to perform LESS cholecystectomy through a single 10-mm incision in model canines. RESULTS: LESS cholecystectomy through a 10-mm incision using the MMAC and MAG was attempted in six dogs. The mean operative time was 85.75 ± 7.14 min. The operation was completed successfully in four cases, with failure occurring in one case due to gallbladder rupture and in another due to bile duct injury. The MMAC provided clear imaging, and the MAG provided sufficient exposure to perform the cholecystectomy. The use of multiple magnetically anchored and controlled instruments did not result in notable collisions. CONCLUSIONS: The designed MMAC and MAG system could be easily maneuvered. LESS cholecystectomy may be feasible through a single 10-mm incision with the simultaneous use of multiple magnetically anchored and controlled instruments.


Asunto(s)
Colecistectomía Laparoscópica/instrumentación , Enfermedades de la Vesícula Biliar/cirugía , Imanes , Cirugía Asistida por Video/instrumentación , Animales , Conductos Biliares/lesiones , Colecistectomía Laparoscópica/efectos adversos , Colecistectomía Laparoscópica/métodos , Perros , Diseño de Equipo , Estudios de Factibilidad , Vesícula Biliar/lesiones , Vesícula Biliar/cirugía , Humanos , Modelos Animales , Tempo Operativo , Complicaciones Posoperatorias/etiología , Rotura/etiología , Cirugía Asistida por Video/efectos adversos , Cirugía Asistida por Video/métodos
11.
Med Sci Monit ; 25: 2016-2023, 2019 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-30880792

RESUMEN

BACKGROUND The purpose of this study was to develop a remote-controlled injection device for T-tube cholangiography to avoid occupational exposure. MATERIAL AND METHODS The remote-controlled injection device has 3 major components: an injection pump, a pressure sensor, and a wireless remote-control panel. The feasibility and effectiveness of this device for T-tube cholangiography was evaluated in ex vivo porcine livers using a laparoscopic training platform and in in vivo canine experiments. RESULTS The contrast dye was successfully injected into the biliary tracts of the ex vivo porcine liver and canines by the designed device. The X-ray images clearly showed the anatomical structure of the bile ducts. No obvious adverse reaction was observed in the dogs during or after the procedure. All steps were controlled remotely, avoiding ionizing radiation exposure to the surgeons. CONCLUSIONS This novel remote-controlled injection device for T-tube cholangiography can assist operators in completing cholangiography remotely and protecting them from occupational exposure.


Asunto(s)
Administración Intravenosa/instrumentación , Colangiografía/métodos , Medios de Contraste/administración & dosificación , Administración Intravenosa/métodos , Animales , Conductos Biliares/diagnóstico por imagen , Colangiografía/instrumentación , Perros , Estudios de Factibilidad , Hígado/diagnóstico por imagen , Masculino , Complicaciones Posoperatorias , Porcinos
12.
Zhongguo Yi Liao Qi Xie Za Zhi ; 43(1): 17-20, 2019 Jan 30.
Artículo en Chino | MEDLINE | ID: mdl-30770684

RESUMEN

A motion unit for sucking robot with a stable motion, convenient operation and process simulation is introduced. The key parameters and process data of the sucking operation were obtained from the clinical work, which provided the basis for the design of the sucking robot motion unit. According to the points of sucking action, robotic thumb, forefinger and metacarpophalangeal joints were used to grip the suction tube, and the servo and arm structure were used to simulate the motion of the wrist and elbow to complete the rotation and push of the sputum suction tube. The feasibility is verified through the advanced sputum suction training model. The movement unit is stable in movement, and can smoothly complete the clamping, feeding, back off protection and rotating tube removal of the sputum suction tube, so as to achieve effective sputum suction.


Asunto(s)
Intubación Intratraqueal , Robótica , Cateterismo , Succión
13.
Oncol Lett ; 16(6): 7102-7116, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30546445

RESUMEN

The aim of the present study was to investigate the racial disparities in the presentation, treatment and survival time of patients with hepatocellular carcinoma (HCC) or intrahepatic cholangiocarcinoma (ICC) between Chinese and other racial groups from the Surveillance, Epidemiology, and End Results (SEER) database between January 1st 2004, and December 31st 2013. Key covariates, including clinical presentation, treatment and survival time, were recorded and compared, demonstrating the racial differences. Kaplan-Meier analysis and Cox regression models were performed to identify these disparities in survival time. A total of 30,954 patients were identified in the SEER database. Among these, 27,767 (89.7%) had HCC and 3,187 (10.3%) had ICC. In the HCC cohort, Chinese patients had the highest survival time. Compared with the mortality risk of Chinese patients, the mortality risk of Other Asian, non-Hispanic white, Hispanic and African-American patients increased by 16.8, 35.1, 28.3 and 33.3%, respectively. Compared with other groups, Chinese patients were more likely to present with localized stage, and without vascular invasion, adjacent invasion and metastasis. In the ICC cohort, the Chinese group had improved survival time, compared with the other groups following univariate analysis, although no significant differences were observed between Chinese and Other Asian and Hispanic patients following adjusting for contributing factors. Furthermore, there was no significant differences in the presentation between the groups, which differed from the HCC analysis. In conclusion, race/ethnicity was a significant independent prognostic factor in the HCC cohort, whereas it was not significant in the ICC cohort. The synergistic effect of contributing factors, including demographic, socioeconomic, biological and treatment differences, caused the racial disparity observed in primary liver cancer survival time.

14.
Zhongguo Yi Liao Qi Xie Za Zhi ; 42(1): 11-13, 2018 Jan 30.
Artículo en Chino | MEDLINE | ID: mdl-29862737

RESUMEN

A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.


Asunto(s)
Medios de Contraste/administración & dosificación , Jeringas , Humanos , Inyecciones , Complicaciones Posoperatorias
15.
J Forensic Leg Med ; 55: 76-86, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29471251

RESUMEN

The near-repeat effect is a well-known phenomenon in crime analysis. The classic research methods focus on two aspects. One is the geographical factor, which indicates the influence of a certain crime risk on other similar crime incidents in nearby places. The other is the social network, which demonstrates the contacts of the offenders and explain "near" as degrees instead of geographic distances. In our work, these coarse-grained patterns discovering methods are summarized as bundled-clues techniques. In this paper, we propose a knotted-clues method. Adopting a data science perspective, we make use of a data interpretative technology and discover that the near-repeat effect is not always so near in geographic or network structure. With this approach, we analyze the near-repeat patterns in all districts of the dataset, as well as in different crime types. Using open source data from Crimes in Chicago provided by Chicago Police Department, we find interesting relationships and patterns with our mining method, which have a positive effect on police deployment and decision making.


Asunto(s)
Crimen/estadística & datos numéricos , Minería de Datos/métodos , Chicago , Análisis por Conglomerados , Conducta Criminal , Interpretación Estadística de Datos , Conjuntos de Datos como Asunto , Humanos , Riesgo
16.
Can J Gastroenterol Hepatol ; 2018: 6181432, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30662889

RESUMEN

Background: To evaluate the AMP-activated protein kinase- (AMPK-) mediated signaling and NF-κB-related inflammatory pathways that contribute to cholestatic diseases in the bile duct ligation (BDL) rat model of chronic cholestasis and verify the protective role of 5-Aminoimidazole-4-carboxamide1-ß-D-ribofuranoside (AICAR) against hepatic injury and fibrosis triggered by cholestasis-related inflammation. Methods: Animals were randomly divided into three groups: sham-operated group, BDL group, and BDL+ AICAR group. Cholestatic liver injury was induced by common BDL. Two weeks later, rats in BDL+AICAR group started receiving AICAR treatment. Hepatic pathology was examined by haematoxylin and eosin (H&E) and sirius red staining and hydroxyproline assay was performed in evaluating the severity of hepatic cirrhosis. Real-time PCR and Western blot were performed for RNA gene expression of RNA and protein levels, respectively. Results: The BDL group showed liver injury as evidenced by histological changes and elevation in serum biochemicals, ductular reaction, fibrosis, and inflammation. The mRNA expression of canonical NF-κB inflammatory cytokines such as TNF-α, IL-1ß, TGF-ß, and the protein of noncanonical NF-κB, P100, and P52 was upregulated in the livers of BDL rats. The BDL rats with the administration of AICAR could induce AMPK activation inhibiting the noncanonical NF-κB pathway to attenuate liver injury and fibrosis in BDL rats. Conclusion: The BDL model of hepatic cholestatic injury resulting in activation of Kupffer cells and recruitment of immune cells might initiate an inflammatory response through activation of the NF-κB pathway. The AMPK activator AICAR significantly alleviated BDL-induced inflammation in rats by mainly inhibiting the noncanonical NF-κB pathway and thus protecting against hepatic injury and fibrosis triggered by BDL.


Asunto(s)
Proteínas Quinasas Activadas por AMP/efectos de los fármacos , Aminoimidazol Carboxamida/análogos & derivados , Colestasis/tratamiento farmacológico , FN-kappa B/efectos de los fármacos , Sustancias Protectoras/farmacología , Ribonucleótidos/farmacología , Transducción de Señal/efectos de los fármacos , Aminoimidazol Carboxamida/farmacología , Animales , Conductos Biliares/cirugía , Colestasis/etiología , Colestasis/metabolismo , Enfermedad Crónica , Modelos Animales de Enfermedad , Macrófagos del Hígado/efectos de los fármacos , Ligadura/efectos adversos , Hígado/patología , Cirrosis Hepática/etiología , Cirrosis Hepática/patología , Ratas
17.
J Surg Res ; 218: 271-276, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28985860

RESUMEN

BACKGROUND: Laparoscopic cholangiojejunostomy (LCJ) with hand-sewn technique is technically difficult and requires a long time to master. The purpose of this study was to assess the feasibility of LCJ using a novel magnetic compression device (MCD) in dogs. METHODS: The concept of the purse-string technique of the circular stapler was used to design a novel MCD for LCJ. To test the feasibility of this MCD in a more clinically relevant situation, four dogs were subjected to bile duct ligation. When the diameter of their bile ducts reached 10 mm, LCJ using MCD was performed. The anastomotic time and expelling time of the magnets were assessed. RESULTS: In the clinically relevant model of bile duct obstruction in dogs, LCJ created with this MCD yielded patent anastomoses. The LCJ procedure using this novel MCD was simple, and the mean anastomotic time was 12.9 ± 1.73 min. All animals recovered smoothly after the operation without complications. All magnets spontaneously passed through the rectum in 14.5 ± 2.08 d after LCJ. CONCLUSIONS: LCJ in dogs using this novel MCD is feasible.


Asunto(s)
Procedimientos Quirúrgicos del Sistema Biliar/instrumentación , Yeyunostomía/instrumentación , Laparoscopía/instrumentación , Magnetismo/instrumentación , Animales , Perros
18.
World J Gastroenterol ; 23(12): 2168-2174, 2017 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-28405144

RESUMEN

AIM: To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy. METHODS: The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models. RESULTS: Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min (38-45 min) in vitro and in 50 min (45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions. CONCLUSION: The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.


Asunto(s)
Laparoscopía/métodos , Magnetismo , Instrumentos Quirúrgicos , Animales , Colecistectomía , Modelos Animales de Enfermedad , Perros , Diseño de Equipo , Masculino , Miniaturización , Modelos Animales , Nefrectomía , Factores de Tiempo
19.
World J Gastroenterol ; 23(46): 8217-8226, 2017 Dec 14.
Artículo en Inglés | MEDLINE | ID: mdl-29290658

RESUMEN

AIM: To explore the possible relationship between fecal microbial communities and non-anastomotic stricture (NAS) after liver transplantation (LT). METHODS: A total of 30 subjects including 10 patients with NAS, 10 patients with no complications after LT, and 10 non-LT healthy individuals were enrolled. Fecal microbial communities were assessed by the 16S rRNA gene sequencing technology. RESULTS: Different from the uncomplicated and healthy groups, unbalanced fecal bacterium ratio existed in patients with NAS after LT. The results showed that NAS patients were associated with a decrease of Firmicutes and Bacteroidetes and an increase of Proteobacteria at the phylum level, with the proportion-ratio imbalance between potential pathogenic families including Enterococcaceae, Streptococcaceae, Enterobacteriaceae, Pseudomonadaceae and dominant families including Bacteroidaceae. CONCLUSION: The compositional shifts of the increase of potential pathogenic bacteria as well as the decrease of dominant bacteria might contribute to the incidence of NAS.


Asunto(s)
Bacterias/aislamiento & purificación , Enfermedades de las Vías Biliares/microbiología , Heces/microbiología , Microbioma Gastrointestinal , Trasplante de Hígado/efectos adversos , Adulto , Bacterias/genética , Bacterias/patogenicidad , Enfermedades de las Vías Biliares/etiología , Constricción Patológica/etiología , Constricción Patológica/microbiología , ADN Bacteriano/aislamiento & purificación , Disbiosis/etiología , Disbiosis/microbiología , Enfermedad Hepática en Estado Terminal/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , ARN Ribosómico 16S/genética , Análisis de Secuencia de ADN
20.
Minim Invasive Ther Allied Technol ; 25(6): 329-336, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27686287

RESUMEN

INTRODUCTION: The concept of magnetic compression technique (MCT) has been accepted by surgeons to solve a variety of surgical problems. In this study, we attempted to explore the feasibility of a splenorenal shunt using MCT in canine and cadaver. MATERIAL AND METHODS: The diameters of the splenic vein (SV), the left renal vein (LRV), and the vertical interval between them, were measured in computer tomography (CT) images obtained from 30 patients with portal hypertension and in 20 adult cadavers. The magnetic devices used for the splenorenal shunt were then manufactured based on the anatomic parameters measured above. The observation of the anatomical structure showed there were no special structural tissues or any important organs between SV and LRV. Then the magnetic compression splenorenal shunt procedure was performed in three dogs and five cadavers. Seven days later, the necrotic tissue between the two magnets was shed and the magnets were removed with the anchor wire. RESULTS: The feasibility of splenorenal shunt via MCT was successfully shown in both canine and cadaver, thus providing a theoretical support for future clinical application.


Asunto(s)
Magnetismo , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Derivación Esplenorrenal Quirúrgica/métodos , Animales , Cadáver , Perros , Estudios de Factibilidad , Femenino , Humanos , Masculino , Venas Renales/anatomía & histología , Venas Renales/cirugía , Vena Esplénica/anatomía & histología , Vena Esplénica/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...