Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 87
Filtrar
1.
Circ Cardiovasc Interv ; 17(4): e013196, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38626077

RESUMEN

BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P=0.02) and remodeling techniques (0.30±0.15 N; P=0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P=0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P=0.02) and triangular resectional techniques (0.36±0.27 N; P=0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P=0.02) or 6 neochordae (0.19±0.16 N; P=0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae (P=0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P=0.01) and 2 neochordae (0.29±0.18 N; P=0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Masculino , Animales , Ovinos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cuerdas Tendinosas/cirugía , Resultado del Tratamiento
2.
Sensors (Basel) ; 24(8)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38676166

RESUMEN

Shoe-based wearable sensor systems are a growing research area in health monitoring, disease diagnosis, rehabilitation, and sports training. These systems-equipped with one or more sensors, either of the same or different types-capture information related to foot movement or pressure maps beneath the foot. This captured information offers an overview of the subject's overall movement, known as the human gait. Beyond sensing, these systems also provide a platform for hosting ambient energy harvesters. They hold the potential to harvest energy from foot movements and operate related low-power devices sustainably. This article proposes two types of strategies (Strategy 1 and Strategy 2) for an energy-autonomous shoe-based system. Strategy 1 uses an accelerometer as a sensor for gait acquisition, which reflects the classical choice. Strategy 2 uses a piezoelectric element for the same, which opens up a new perspective in its implementation. In both strategies, the piezoelectric elements are used to harvest energy from foot activities and operate the system. The article presents a fair comparison between both strategies in terms of power consumption, accuracy, and the extent to which piezoelectric energy harvesters can contribute to overall power management. Moreover, Strategy 2, which uses piezoelectric elements for simultaneous sensing and energy harvesting, is a power-optimized method for an energy-autonomous shoe system.

3.
Atherosclerosis ; : 117518, 2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38627162

RESUMEN

BACKGROUND AND AIMS: There are a limited number of pharmacologic therapies for coronary artery disease, and few rodent models of occlusive coronary atherosclerosis and consequent myocardial infarction with which one can rapidly test new therapeutic approaches. Here, we characterize a novel, fertile, and easy-to-use HDL receptor (SR-B1)-based model of atherogenic diet-inducible, fatal coronary atherosclerosis, the SR-B1ΔCT/LDLR KO mouse. Additionally, we test intramyocardial injection of Stromal Cell-Derived Factor-1 alpha (SDF-1α), a potent angiogenic cytokine, as a possible therapy to rescue cardiac function in this mouse. METHODS: SR-B1ΔCT/LDLR KO mice were fed the Paigen diet or standard chow diet, and we determined the effects of the diets on cardiac function, histology, and survival. After two weeks of feeding either the Paigen diet (n = 24) or standard chow diet (n = 20), the mice received an intramyocardial injection of either SDF-1α or phosphate buffered saline (PBS). Cardiac function and angiogenesis were assessed two weeks later. RESULTS: When six-week-old mice were fed the Paigen diet, they began to die as early as 19 days later and 50% had died by 38 days. None of the mice maintained on the standard chow diet died by day 72. Hearts from mice on the Paigen diet showed evidence of cardiomegaly, myocardial infarction, and occlusive coronary artery disease. For the five mice that survived until day 28 that underwent an intramyocardial injection of PBS on day 15, the average ejection fraction (EF) decreased significantly from day 14 (the day before injection, 52.1 ± 4.3%) to day 28 (13 days after the injection, 30.6 ± 6.8%) (paired t-test, n = 5, p = 0.0008). Of the 11 mice fed the Paigen diet and injected with SDF-1α on day 15, 8 (72.7%) survived to day 28. The average EF for these 8 mice increased significantly from 48.2 ± 7.2% on day 14 to63.6 ± 6.9% on day 28 (Paired t-test, n = 8, p = 0.003). CONCLUSIONS: This new mouse model and treatment with the promising angiogenic cytokine SDF-1α may lead to new therapeutic approaches for ischemic heart disease.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38320627

RESUMEN

OBJECTIVE: The objective of this study is to evaluate survival for combined heart-lung transplant (HLTx) recipients across 4 decades at a single institution. We aim to summarize our contemporary practice based on more than 271 HLTx procedures over 40 years. METHODS: Data were collected from a departmental database and the United Network for Organ Sharing. Recipients younger than age 18 years, those undergoing redo HLTx, or triple-organ system transplantation were excluded, leaving 271 patients for analysis. The pioneering era was defined by date of transplant between 1981 and 2000 (n = 155), and the modern era between 2001 and 2022 (n = 116). Survival analysis was performed using cardinality matching of populations based on donor and recipient age, donor and recipient sex, ischemic time, and sex matching. RESULTS: Between 1981 and 2022, 271 HLTx were performed at a single institution. Recipients in the modern era were older (age 42 vs 34 y; P < .001) and had shorter waitlist times (78 vs 234 days; P < .001). Allografts from female donors were more common in the modern era (59% vs 39%; P = .002). In the matched survival analysis, 30-day survival (97% vs 84%; P = .005), 1-year survival (89% vs 77%; P = .041), and 10-year survival (53% vs 26%; P = .012) significantly improved in the modern era relative to the pioneering era, respectively. CONCLUSIONS: Long-term survival in HLTx is achievable with institutional experience and may continue to improve in the coming decades. Advances in mechanical circulatory support, improved maintenance immunosuppression, and early recognition and management of acute complications such as primary graft dysfunction and acute rejection have dramatically improved the prognosis for recipients of HLTx in our contemporary institutional experience.

6.
Cardiovasc Eng Technol ; 15(2): 224-231, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38238600

RESUMEN

PURPOSE: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation. METHODS: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism. An ex vivo porcine VSARR model with annular dilation and AR was developed (n = 4) and used for hemodynamic, echocardiography, and high-speed videography data collection. RESULTS: After ring annuloplasty repair using the EASE aortic ring, the regurgitant fraction decreased from 23.6 ± 6.9% from the VSARR model to 7.4 ± 5.6% (p = 0.05), which was similar to that measured from baseline with a regurgitant fraction of 10.2 ± 3.9% (p = 0.34). The leaflet coaptation height after annuloplasty repair also significantly increased from that measured in VSARR model (0.4 ± 0.1 cm) to 0.9 ± 0.1 cm (p = 0.0004), a level similar to that measured in baseline (1.1 ± 0.1 cm, p = 0.28). CONCLUSION: Using an ex vivo VSARR model, the EASE ring successfully reduced AR by reducing the annular diameter and improving leaflet coaptation. With its broad applicability and ease of use, this device has the potential to have a significant impact on patients suffering worldwide from AR due to root aneurysms.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Anuloplastia de la Válvula Cardíaca , Prótesis Valvulares Cardíacas , Hemodinámica , Impresión Tridimensional , Diseño de Prótesis , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Animales , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Anuloplastia de la Válvula Cardíaca/instrumentación , Sus scrofa , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Modelos Animales de Enfermedad , Modelos Cardiovasculares
7.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38258541

RESUMEN

OBJECTIVES: Artificial neochordae implantation is commonly used for mitral valve (MV) repair. However, neochordae length estimation can be difficult to perform. The objective was to assess the impact of neochordae length changes on MV haemodynamics and neochordal forces. METHODS: Porcine MVs (n = 6) were implanted in an ex vivo left heart simulator. MV prolapse (MVP) was generated by excising at least 2 native primary chordae supporting the P2 segments from each papillary muscle. Two neochordae anchored on each papillary muscle were placed with 1 tied to the native chord length (exact length) and the other tied with variable lengths from 2× to 0.5× of the native length (variable length). Haemodynamics, neochordal forces and echocardiography data were collected. RESULTS: Neochord implantation repair successfully eliminated mitral regurgitation with repaired regurgitant fractions of approximately 4% regardless of neochord length (P < 0.01). Leaflet coaptation height also significantly improved to a minimum height of 1.3 cm compared with that of MVP (0.9 ± 0.4 cm, P < 0.05). Peak and average forces on exact length neochordae increased as variable length neochordae lengths increased. Peak and average forces on the variable length neochordae increased with shortened lengths. Overall, chordal forces appeared to vary more drastically in variable length neochordae compared with exact length neochordae. CONCLUSIONS: MV regurgitation was eliminated with neochordal repair, regardless of the neochord length. However, chordal forces varied significantly with different neochord lengths, with a preferentially greater impact on the variable length neochord. Further validation studies may be performed before translating to clinical practices.


Asunto(s)
Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Animales , Porcinos , Válvula Mitral/cirugía , Cuerdas Tendinosas/cirugía , Diseño de Prótesis , Insuficiencia de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía
8.
Innovations (Phila) ; 19(1): 88-91, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38258625

RESUMEN

Heart transplantation utilizing deceased after circulatory death (DCD) donors has expanded the donor pool through the use of ex vivo normothermic perfusion. Compared with brain death donation, the conventional method of performing DCD heart transplantation includes an additional period of warm and cold ischemia. We have developed a beating heart implantation technique that obliviates the need for a second cardioplegic arrest and the associated reperfusion injury. We hypothesize this reproducible method may improve short-term and long-term outcomes to mirror results seen in brain death donors and provide details on how to perform beating heart transplantation.


Asunto(s)
Muerte Encefálica , Trasplante de Corazón , Humanos , Trasplante de Corazón/métodos , Donantes de Tejidos , Perfusión/métodos
9.
J Thorac Cardiovasc Surg ; 167(4): e78-e89, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37160219

RESUMEN

OBJECTIVE: Estimating neochord lengths during mitral valve repair is challenging, because approximation must be performed largely based on intuition and surgical experience. Little data exist on quantifying the effects of neochord length misestimation. We aimed to evaluate the impact of neochord length on papillary muscle forces and mitral valve hemodynamics, which is especially pertinent because increased forces have been linked to aberrant mitral valve biomechanics. METHODS: Porcine mitral valves (n = 8) were mounted in an ex vivo heart simulator, and papillary muscles were fixed to high-resolution strain gauges while hemodynamic data were recorded. We used an adjustable system to modulate neochord lengths. Optimal length was qualitatively verified by a single experienced operator, and neochordae were randomly lengthened or shortened in 1-mm increments up to ±5 mm from the optimal length. RESULTS: Optimal length neochordae resulted in the lowest peak composite papillary muscle forces (6.94 ± 0.29 N), significantly different from all lengths greater than ±1 mm. Both longer and shorter neochordae increased forces linearly according to difference from optimal length. Both peak papillary muscle forces and mitral regurgitation scaled more aggressively for longer versus shorter neochordae by factors of 1.6 and 6.9, respectively. CONCLUSIONS: Leveraging precision ex vivo heart simulation, we found that millimeter-level neochord length differences can result in significant differences in papillary muscle forces and mitral regurgitation, thereby altering valvular biomechanics. Differences in lengthened versus shortened neochordae scaling of forces and mitral regurgitation may indicate different levels of biomechanical tolerance toward longer and shorter neochordae. Our findings highlight the need for more thorough biomechanical understanding of neochordal mitral valve repair.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Animales , Porcinos , Músculos Papilares/cirugía , Insuficiencia de la Válvula Mitral/cirugía , Fenómenos Biomecánicos , Cuerdas Tendinosas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
10.
JTCVS Open ; 15: 164-172, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37808060

RESUMEN

Objective: This study aimed to biomechanically evaluate the force profiles on the anterior primary and secondary chordae after neochord repair for anterior valve prolapse with varied degrees of residual mitral regurgitation using an ex vivo heart simulator. Methods: The experiment used 8 healthy porcine mitral valves. Chordal forces were measured using fiber Bragg grating sensors on primary and secondary chordae from A2 segments. The anterior valve prolapse model was generated by excising 2 primary chordae at the A2 segment. Neochord repair was performed with 2 pairs of neochords. Varying neochord lengths simulated postrepair residual mitral regurgitation with regurgitant fraction at >30% (moderate), 10% to 30% (mild), and <10% (perfect repair). Results: Regurgitant fractions of baseline, moderate, mild, and perfect repair were 4.7% ± 0.8%, 35.8% ± 2.1%, 19.8% ± 2.0%, and 6.0% ± 0.7%, respectively (P < .001). Moderate had a greater peak force of the anterior primary chordae (0.43 ± 0.06 N) than those of baseline (0.19 ± 0.04 N; P = .011), mild (0.23 ± 0.05 N; P = .041), and perfect repair (0.21 ± 0.03 N; P = .006). In addition, moderate had a greater peak force of the anterior secondary chordae (1.67 ± 0.17 N) than those of baseline (0.64 ± 0.13 N; P = .003), mild (0.84 ± 0.24 N; P = .019), and perfect repair (0.68 ± 0.14 N; P = .001). No significant differences in peak and average forces on both primary and secondary anterior chordae were observed between the baseline and perfect repair as well as the mild and perfect repair. Conclusions: Moderate residual mitral regurgitation after neochord repair was associated with increased anterior primary and secondary chordae forces in our ex vivo anterior valve prolapse model. This difference in chordal force profile may influence long-term repair durability, providing biomechanical evidence in support of obtaining minimal regurgitation when repairing mitral anterior valve prolapse.

11.
Ann Cardiothorac Surg ; 12(4): 326-337, 2023 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-37554719

RESUMEN

Background: Several conduit configurations, such as straight graft (SG), Valsalva graft (VG), anticommissural plication (ACP), and the Stanford modification (SMOD) technique, have been described for the valve-sparing aortic root replacement (VSARR) procedure. Prior ex vivo studies have evaluated the impact of conduit configurations on root biomechanics, but the mock coronary artery circuits used could not replicate the physical properties of native coronary arteries. Moreover, the individual leaflet's biomechanics, including the fluttering phenomenon, were unclear. Methods: Porcine aortic roots with coronary arteries were explanted (n=5) and underwent VSARR using SG, VG, ACP, and SMOD for evaluation in an ex vivo left heart flow loop simulator. Additionally, 762 patients who underwent VSARR from 1993 through 2022 at our center were retrospectively reviewed. Analysis of variance was performed to evaluate differences between different conduit configurations, with post hoc Tukey's correction for pairwise testing. Results: SG demonstrated lower rapid leaflet opening velocity compared with VG (P=0.001) and SMOD (P=0.045) in the left coronary cusp (LCC), lower rapid leaflet closing velocity compared with VG (P=0.04) in the right coronary cusp (RCC), and lower relative opening force compared with ACP (P=0.04) in the RCC. The flutter frequency was lower in baseline compared with VG (P=0.02) and in VG compared with ACP (P=0.03) in the LCC. Left coronary artery mean flow was higher in SG compared with SMOD (P=0.02) and ACP (P=0.05). Clinically, operations using SG compared with sinus-containing graft was associated with shorter aortic cross-clamp and cardiopulmonary bypass time (P<0.001, <0.001). Conclusions: SG demonstrated hemodynamics and biomechanics most closely recapitulating those from the native root with significantly shorter intraoperative times compared with repair using sinus-containing graft. Future in vivo validation studies as well as correlation with comprehensive, comparative clinical study outcomes may provide additional invaluable insights regarding strategies to further enhance repair durability.

12.
JTCVS Tech ; 20: 45-54, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37555034

RESUMEN

Objectives: An increasing number of high-risk patients with previous mitral valve annuloplasty require transcatheter mitral valve replacement due to recurrent regurgitation. Annulus dilation with a transcatheter balloon is often performed before valve-in-ring transcatheter mitral valve replacement, which is believed to reduce misalignment and paravalvular leakage, yet little evidence exists to support this practice. Our objective was to generate intuitive annuloplasty ring analyses for improved valve-in-ring transcatheter mitral valve replacement planning. Methods: We generated a mathematical model that calculates image-tracked differential ring curvature to build quantifications for improved planning for valve-in-ring procedures. Carpentier-Edwards Physio M24 and M30 (n = 2 each), Physio II M24 and M26 (n = 3 each), LivaNova AnnuloFlex M26 (n = 2), and Edwards Geoform M28 (n = 2) rings were tested with a 30-mm Toray Inoue balloon inflated to maximum rated pressures. Results: Curvature variance reduces with larger ring sizes, indicating that larger rings are initially more circular than smaller ones. Evaluated semi-rigid and rigid rings showed little to no difference between pre- and post-dilation states. Annuloflex rings (flexible band) showed a postdilation variance reduction of 32.83% (P < .001) followed by an increase after 10 minutes of relaxation that was still reduced by 19.62% relative to the initial state (P < .001). Conclusions: We discovered that balloon dilation does not significantly deform evaluated semi-rigid or rigid rings at maximum rated balloon pressures. This may mean that dilation for these conditions before valve-in-ring transcatheter mitral valve replacement is unnecessary. Our mathematical approach creates a foundation for extended classification of this practice, providing meaningful quantification of ring geometry.

13.
Transplant Proc ; 55(7): 1674-1680, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37393169

RESUMEN

BACKGROUND: Both combined heart-kidney transplantation and ventricular assist devices (VADs) pose significant challenges, including sensitization, immunosuppressive treatment, and infrastructure demands. Despite these challenges, we hypothesized that the recipients of combined heart-kidney transplants with and without VADs would have equivalent survival. We aimed to compare the survival of heart-kidney transplant recipients with and without prior VAD placement. METHODS: We retrospectively analyzed all patients enrolled in the United Network for Organ Sharing database who underwent heart-kidney transplants. We created a matched cohort of patients undergoing heart-kidney transplantation with or without prior VAD using 1:1 nearest propensity-score matching with preoperative variables. RESULTS: In the propensity-matched cohort, 399 patients underwent heart-kidney transplantation with prior VAD, and 399 underwent heart-kidney transplantation without prior VAD. The estimated survival of heart--kidney recipients with prior VAD was 84.8% at one year, 81.2% at 3 years, and 75.3% at 5 years. The estimated survival of heart-kidney recipients without prior VAD was 86.8.7% at one year, 84.0% at 3 years, and 78.8% at 5 years. There was no statistically significant difference in the survival of heart-kidney transplant recipients with or without prior VAD at one year (P = .42; Figure 2), 3 years (P = .34), or 5 years (P = .30). CONCLUSION: Despite the increased challenge of heart-kidney transplantation in recipients with prior VAD, we demonstrated that these patients have similar survival to those who underwent heart-kidney transplantation without previous VAD placement.


Asunto(s)
Insuficiencia Cardíaca , Trasplante de Corazón , Corazón Auxiliar , Trasplante de Riñón , Humanos , Trasplante de Riñón/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Trasplante de Corazón/efectos adversos , Riñón , Insuficiencia Cardíaca/cirugía
14.
Bioengineering (Basel) ; 10(7)2023 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-37508869

RESUMEN

Cardiovascular diseases are the leading cause of morbidity and mortality in the United States. Cardiac tissue engineering is a direction in regenerative medicine that aims to repair various heart defects with the long-term goal of artificially rebuilding a full-scale organ that matches its native structure and function. Three-dimensional (3D) bioprinting offers promising applications through its layer-by-layer biomaterial deposition using different techniques and bio-inks. In this review, we will introduce cardiac tissue engineering, 3D bioprinting processes, bioprinting techniques, bio-ink materials, areas of limitation, and the latest applications of this technology, alongside its future directions for further innovation.

15.
JTCVS Open ; 14: 77-86, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37425479

RESUMEN

Objectives: Although bioprosthetic valves have excellent hemodynamic properties and can eliminate the need for lifelong anticoagulation therapy, these devices are associated with high rates of reoperation and limited durability. Although there are many distinct bioprosthesis designs, all bioprosthetic valves have historically featured a trileaflet pattern. This in silico study examines the biomechanical effect of modulating the number of leaflets in a bioprosthetic valve. Methods: Bioprosthetic valves with 2 to 6 leaflets were designed in Fusion 360 using quadratic spline geometry. Leaflets were modeled with standard mechanical parameters for fixed bovine pericardial tissue. A mesh of each design was structurally evaluated using finite element analysis software Abaqus CAE. Maximum von Mises stresses during valve closure were assessed for each leaflet geometry in both the aortic and mitral position. Results: Computational analysis demonstrated that increasing the number of leaflets is associated with reduction in leaflet stresses. Compared with the standard trileaflet design, a quadrileaflet pattern reduces leaflet maximum von Mises stresses by 36% in the aortic position and 38% in the mitral position. Maximum stress was inversely proportional to the square of the leaflet quantity. Surface area increased linearly and central leakage increased quadratically with leaflet quantity. Conclusions: A quadrileaflet pattern was found to reduce leaflet stresses while limiting increases in central leakage and surface area. These findings suggest that modulating the number of leaflets can allow for optimization of the current bioprosthetic valve design, which may translate to more durable valve replacement bioprostheses.

16.
18.
Heart ; 109(11): 887, 2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-37080763
20.
J Biosci Bioeng ; 135(6): 493-499, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36966053

RESUMEN

Cardiovascular disease, primarily caused by coronary artery disease, is the leading cause of death in the United States. While standard clinical interventions have improved patient outcomes, mortality rates associated with eventual heart failure still represent a clinical challenge. Macrorevascularization techniques inadequately address the microvascular perfusion deficits that persist beyond primary and secondary interventions. In this work, we investigate a photosynthetic oxygen delivery system that rescues the myocardium following acute ischemia. Using a simple microfluidic system, we encapsulated Synechococcus elongatus into alginate hydrogel microparticles (HMPs), which photosynthetically deliver oxygen to ischemic tissue in the absence of blood flow. We demonstrate that HMPs improve the viability of S. elongatus during the injection process and allow for simple oxygen diffusion. Adult male Wistar rats (n = 45) underwent sham surgery, acute ischemia reperfusion surgery, or a chronic ischemia reperfusion surgery, followed by injection of phosphate buffered saline (PBS), S. elongatus suspended in PBS, HMPs, or S. elongatus encapsulated in HMPs. Treatment with S. elongatus-HMPs mitigated cellular apoptosis and improved left ventricular function. Thus, delivery of S. elongatus encapsulated in HMPs improves clinical translation by utilizing a minimally invasive delivery platform that improves S. elongatus viability and enhances the therapeutic benefit of a novel photosynthetic system for the treatment of myocardial ischemia.


Asunto(s)
Cianobacterias , Hidrogeles , Ratas , Animales , Masculino , Microfluídica , Ratas Wistar , Miocardio , Oxígeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...