Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Rev Sci Instrum ; 94(7)2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37477554

RESUMEN

Laser-driven x-ray backlighting can be used to image fast dynamic processes like the propagation of laser-driven shock waves in matter. We demonstrate and evaluate the feasibility of operating the JUNGFRAU detector designed by PSI, a direct detecting x-ray detector, in environments with extreme electromagnetic pulses. The electromagnetic pulse-protective housing is specifically designed for this detector and optimized for pump-probe experiments at the Petawatt High-Energy Laser for Heavy Ion EXperiments (PHELIX) facility at the GSI Helmholtzzentrum für Schwerionenforschung GmbH. The beryllium x-ray entrance window of the protective housing has a high x-ray transmission of 94% at 8 keV. Measurements have shown that the housing simultaneously provides a relative damping of the electromagnetic field on average higher than 1000 in the frequency range of 100 MHz to 5 GHz. The results demonstrate the feasibility of operating digital detectors in experiments where strong electromagnetic pulses are present.

3.
J Imaging ; 7(9)2021 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-34564104

RESUMEN

X-ray backlighters allow the capture of sharp images of fast dynamic processes due to extremely short exposure times. Moiré imaging enables simultaneously measuring the absorption and differential phase-contrast (DPC) of these processes. Acquiring images with one single shot limits the X-ray photon flux, which can result in noisy images. Increasing the photon statistics by repeating the experiment to gain the same image is not possible if the investigated processes are dynamic and chaotic. Furthermore, to reconstruct the DPC and transmission image, an additional measurement captured in absence of the object is required. For these reference measurements, shot-to-shot fluctuations in X-ray spectra and a source position complicate the averaging of several reference images for noise reduction. Here, two approaches of processing multiple reference images in combination with one single object image are evaluated regarding the image quality. We found that with only five reference images, the contrast-to-noise ratio can be improved by approximately 13% in the DPC image. This promises improvements for short-exposure single-shot acquisitions of rapid processes, such as laser-produced plasma shock-waves in high-energy density experiments at backlighter X-ray sources such as the PHELIX high-power laser facility.

4.
Opt Express ; 22(24): 29505-14, 2014 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-25606884

RESUMEN

We used time-resolved shadowgraphy to characterize the pre-plasma formation in solid-target interaction experiments with micrometer-scale accuracy. We performed quantitative measurements of the plasma density for amplified spontaneous emission (ASE) levels ranging from 2 · 10(-7) to 10(-10) backed with 2-dimensional hydrodynamic simulations. We find that ASE levels above 10(-9) are able to create a significant pre-plasma plume that features a plasma canal driving a self-focusing of the laser beam. For ASE levels of 10(-10), no ASE pre-plasma could be detected.


Asunto(s)
Electricidad , Rayos Láser , Gases em Plasma/química , Simulación por Computador , Procesamiento de Imagen Asistido por Computador , Electricidad Estática , Factores de Tiempo
5.
Opt Lett ; 35(4): 450-2, 2010 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-20160780

RESUMEN

This Letter reports on the optimization of a tabletop nickel-like molybdenum transient collisionally excited soft x-ray laser (SXRL) at 18.9 nm performed by a double-pulse single-beam grazing incidence pumping (DGRIP). This scheme allows for the first time, to our knowledge, the full control of the pump laser parameters including the pre-pulse duration optimally generating the SXRL amplifier under a grazing incidence. The single-beam geometry of the collinear double-pulse propagation guarantees the ideal overlap of the pre-pulse and main pulse from shot to shot resulting in a more efficient and highly stable SXRL output. SXRL energies up to 2.2 microJ are obtained with a total pump energy less than 1 J for several hours at a 10 Hz repetition rate without realignment under once optimized double pumping pulse parameters including energy ratio, time delay, pre-pulse and main pulse durations, and line focus width.

6.
Opt Express ; 16(14): 10398-404, 2008 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-18607451

RESUMEN

An optimized pumping geometry for transient collisionally excited soft X-ray lasers is presented, similar to the geometry proposed by [1]. In contrast to usual approaches, where a nanosecond pre-pulse is assumed to provide the optimal plasma preparation and a picosecond pulse performs the final heating- and excitation process, two pulses of equal duration in the range around 10 picoseconds are applied. Both pulses are produced in the front end of the CPA pump laser. They are focused onto the target with the same spherical mirror under non-normal incidence geometry, optimized for efficient traveling wave excitation for the main-pulse. A first experiment was performed on Ni-like palladium (14.7 nm) at less than 500mJ total pulse energy on the target. This proves that this configuration is at least as favorable as the standard GRIP scheme, providing much simpler and more reliable operation.

7.
Phys Rev E Stat Nonlin Soft Matter Phys ; 75(4 Pt 2): 045401, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17500953

RESUMEN

The effects of the incidence angle of the main pump (MP) pulse in non-normal pumping geometry and the influence of the MP duration are investigated experimentally and theoretically for a transient collisionally pumped (TCE) x-ray laser in Ni-like Zr at 45 degrees and 72 degrees incidence angle on the target. The way they transfer to the x-ray laser output depends on the preplasma conditions, most notably on the average ionization distribution at the arrival of the MP. Moreover, contrary to previous grazing incidence pumping results, it is found that the shortest attainable MP maximizes the output. Modeling of the experimental results is performed with EHYBRID code. The results are important for scaling high repetition-rate non-normal incidence pumped lasers to sub- 10nm wavelengths.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA