Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Lasers Med Sci ; 28(3): 919-24, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-22869160

RESUMEN

This study aims to evaluate whether optical coherence tomography (OCT) using both the surface and the endoluminal technique is feasible to investigate the locations and degree of encrustation process in clinically used ureteral stents. After removal from patients, 14 polyurethane JJ stents were investigated. A fresh JJ served as a control. The external surfaces were examined using an endoscopic surface OCT whereas the intraluminal surfaces were investigated by an endoluminal radial OCT device. The focus was on detection of encrustation or crystalline sedimentation. In 12 female and two male patients, the median indwelling time of the ureteral catheter was 100 days (range, 19-217). Using the endoluminal OCT, the size and grade of intraluminal encrustation could be expressed as a percentage relating to the open lumen of the reference stent. The maximum encrustation observed resulted in a remaining unrestricted lumen of 15-35 % compared to the reference. The luminal reduction caused by encrustation was significantly higher at the proximal end of the ureteral stent as compared to its distal part. The extraluminal OCT investigations facilitated the characterization of extraluminal encrustation. OCT techniques were feasible and facilitated the detection of encrustation of double pigtail catheters on both the extra and intra luminal surface. Quantitative expression of the degree of intraluminal encrustation could be achieved, with the most dense and thickened occurrence of intraluminal incrustation in the upper curl of the JJ stent.


Asunto(s)
Stents/efectos adversos , Catéteres Urinarios/efectos adversos , Biopelículas/crecimiento & desarrollo , Cristalización , Remoción de Dispositivos , Femenino , Humanos , Masculino , Poliuretanos , Factores de Riesgo , Stents/microbiología , Factores de Tiempo , Tomografía de Coherencia Óptica , Catéteres Urinarios/microbiología
2.
J Biomed Opt ; 17(6): 068005, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22734791

RESUMEN

Laparoscopic/robotic partial nephrectomy (LPN) is increasingly considered for small renal tumors (RT). This demands new compatible surgical tools for RT-resection, such as lasers, to optimize cutting and coagulation. This work aims to characterize ex vivo handling requirements for six medically approved laser devices emitting different light wavelengths (940, 1064, 1318, 1470, 1940, and 2010 nm) amenable for LPN. Incisions were made by laser fibers driven by a computer-controlled stepping motor allowing precise linear movement with a preset velocity at a fixed fiber-tip distance to tissue. Optical parameters were measured on 200 µm tissue slices. Cutting quality depended on power output, fiber velocity and fiber-tip distance to tissue. Contact manner is suitable for cutting while a noncontact manner (5 mm distance) induces coagulation. Ablation threshold differs for each wavelength. Ablation depth is proportional to power output (within limit) while axial and superficial coagulation remains mostly constant. Increased fiber velocity compromises the coagulation quality. Optical parameters of porcine kidney tissue demonstrate that renal absorption coefficient follows water absorption in the 2 µm region while for other spectral regions (900 to 1500 and 1 µm) the tissue effects are influenced by other chromophores and scattering. Tissue color changes demonstrate dependencies on irradiance, scan velocity, and wavelength. Current results clearly demonstrate that surgeons considering laser-assisted RT excisions should be aware of the mentioned technical parameters (power output, fiber velocity and fiber-tip tissue-distance) rather than wavelength only.


Asunto(s)
Terapia por Láser/métodos , Nefrectomía/métodos , Absorción , Animales , Diseño de Equipo , Hemostasis , Isquemia/patología , Riñón/patología , Neoplasias Renales/terapia , Laparoscopía/métodos , Terapia por Láser/instrumentación , Rayos Láser , Nefrectomía/instrumentación , Óptica y Fotónica/métodos , Perfusión , Reproducibilidad de los Resultados , Porcinos
4.
Urol Int ; 84(1): 119-21, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20173383

RESUMEN

A 74-year-old man with metastatic renal cell carcinoma and a history of cardiac failure was treated with sunitinib malate. MUGA echocardiography could not detect a relevant change in the ejection fraction although the clinical situation of the patient worsened dramatically. The only parameter to hint at the deteriorated cardiac function was plasma N-terminal pro-brain natriuretic peptide (BNP). Finally, the patient died after only one cycle of sunitinib treatment. We propose to prospectively include BNP for the early detection of cardiovascular decompensation in high-risk patients. Future studies concerning the relevance of BNP in drug-related cardiotoxicity are urgently needed.


Asunto(s)
Carcinoma de Células Renales/complicaciones , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/tratamiento farmacológico , Indoles/uso terapéutico , Neoplasias Renales/complicaciones , Péptido Natriurético Encefálico/sangre , Pirroles/uso terapéutico , Anciano , Carcinoma de Células Renales/sangre , Carcinoma de Células Renales/tratamiento farmacológico , Ecocardiografía/métodos , Humanos , Neoplasias Renales/sangre , Neoplasias Renales/tratamiento farmacológico , Neoplasias Pulmonares/secundario , Masculino , Metástasis de la Neoplasia , Pronóstico , Estudios Retrospectivos , Sunitinib , Trombosis/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA