Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Phys Rev Lett ; 111(6): 067202, 2013 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-23971606

RESUMEN

Using an optimally coupled nanometer-scale SQUID, we measure the magnetic flux originating from an individual ferromagnetic Ni nanotube attached to a Si cantilever. At the same time, we detect the nanotube's volume magnetization using torque magnetometry. We observe both the predicted reversible and irreversible reversal processes. A detailed comparison with micromagnetic simulations suggests that vortexlike states are formed in different segments of the individual nanotube. Such stray-field free states are interesting for memory applications and noninvasive sensing.

2.
Phys Rev Lett ; 108(9): 097001, 2012 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-22463659

RESUMEN

We propose a transistorlike circuit including two serially connected segments of a narrow superconducting nanowire joint by a wider segment with a capacitively coupled gate in between. This circuit is made of amorphous NbSi film and embedded in a network of on-chip Cr microresistors ensuring a sufficiently high external electromagnetic impedance. Assuming a virtual regime of quantum phase slips (QPS) in two narrow segments of the wire, leading to quantum interference of voltages on these segments, this circuit is dual to the dc SQUID. Our samples demonstrated appreciable Coulomb blockade voltage (analog of critical current of the SQUIDs) and periodic modulation of this blockade by an electrostatic gate (analog of flux modulation in the SQUIDs). The model of this QPS transistor is discussed.

3.
Phys Rev Lett ; 102(9): 097004, 2009 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-19392556

RESUMEN

We investigate a quadratic-quartic anharmonic oscillator formed by a potential well between two potential barriers. We realize this novel potential with a dc SQUID at near-zero current bias and flux bias near half a flux quantum. Escape out of the central well can occur via tunneling through either of the two barriers. We find good agreement with a generalized double-path macroscopic quantum tunneling theory. We also demonstrate an "optimal line" in current and flux bias along which the oscillator, which can be operated as a phase qubit, is insensitive to decoherence due to low-frequency current fluctuations.

4.
Phys Rev Lett ; 96(16): 167001, 2006 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-16712260

RESUMEN

We show that the electrical impedance of a small-capacitance Josephson junction also includes, in addition to the capacitive term -i/(omega)CB, an inductive term i(omega)LB. Similar to the known Bloch capacitance CB(q), the Bloch inductance LB(q) also depends periodically on the quasicharge, q, and its maximum value achieved at q=e(mod 2e) always exceeds the value of the Josephson inductance of this junction LJ(phi) at fixed phi=0. The effect of the Bloch inductance on the dynamics of a single junction and a one-dimensional array is described.

5.
Vestn Khir Im I I Grek ; 164(4): 75-80, 2005.
Artículo en Ruso | MEDLINE | ID: mdl-16755743

RESUMEN

Latent dysfunction of the heart right ventricle and hypovolemia were assessed in 50 patients divided into 4 groups, operated on the heart, abdominal aorta and lungs. It was found that after revascularization of the myocardium the diastolic disorders prevailed. In patients operated for the heart valve (mitral and aortal) diseases prevailing were the systolic and pump dysfunction of the right ventricle. Insufficiency of the right ventricle in these groups was 13% and 22% respectively. After operations on the abdominal aorta a combination of the systolic and diastolic impairments of the right ventricle were observed. After extended resections of the lungs there was a characteristic combination of systolic, diastolic and pump dysfunctions. When the operation was followed by a decreased minute volume of circulation, its cause was hypovolemia in 29% of cases in the examined surgical patients. The investigation of the right ventricle functions with the help of pulmonary arterial volumetry can reveal their latent dysfunctions as well as hypovolemia in a considerable part of surgical patients.


Asunto(s)
Anestesia/métodos , Cuidados Críticos/métodos , Cuidados Posoperatorios , Disfunción Ventricular Derecha/diagnóstico , Disfunción Ventricular Derecha/prevención & control , Insuficiencia de la Válvula Aórtica/cirugía , Presión Sanguínea/fisiología , Cateterismo Cardíaco/métodos , Ecocardiografía , Femenino , Hemodinámica/fisiología , Humanos , Hipertensión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/cirugía
6.
Phys Rev Lett ; 91(19): 197002, 2003 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-14611603

RESUMEN

We observed current-voltage characteristics of superconducting single charge transistors with on-chip resistors of R approximately R(Q)=h/4e(2) approximately 6.45 kOmega, which are explained in terms of Cooper pair cotunneling. Both the effective strength of Josephson coupling and the cotunneling current are modulated by the gate-induced charge on the transistor island. For increasing values of the resistance R we found the Cooper pair current at small transport voltages to be dramatically suppressed.

7.
Phys Rev Lett ; 86(15): 3388-91, 2001 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-11327977

RESUMEN

A quantum electrometer is proposed which is based on charge modulation of the Josephson supercurrent in the Bloch transistor inserted in a superconducting ring. As this ring is inductively coupled to a high- Q resonance tank circuit, the variations of the charge on the transistor island are converted into variations of amplitude and phase of oscillations in the tank. These variations are amplified and then detected. At sufficiently low temperature of the tank the device sensitivity is determined by the energy resolution of the amplifier, that can be reduced down to the standard quantum limit of 1 / 2Planck's over 2pi. A "back-action-evading" scheme of subquantum limit measurements is proposed.

10.
Voen Med Zh ; (8): 47-9, 1991 Aug.
Artículo en Ruso | MEDLINE | ID: mdl-1755228

RESUMEN

On the basis of the analysis of medical publications and practical experience in surgical care to the wounded the article discusses the tactics of infusion and transfusion therapy that should be used at the stages of medical evacuation. The authors emphasize the importance of the infusion therapy nearness to the place of accident, the necessity to provide medical personnel with adequate facilities for this task, careful attitude for autologous blood of wounded, blood reinfusion during pleural puncture or thoracotomy [correction of teracotomia]. The schemes of infusion and transfusion therapy for each stage of medical evacuation are enclosed.


Asunto(s)
Transfusión Sanguínea , Primeros Auxilios , Fluidoterapia , Personal Militar , Traumatismos Torácicos/terapia , Transfusión de Sangre Autóloga , Hemorragia/terapia , Humanos , Cuidados Preoperatorios , U.R.S.S.
11.
Khirurgiia (Sofiia) ; 44(1): 1-3, 1991.
Artículo en Búlgaro | MEDLINE | ID: mdl-1942894

RESUMEN

The operation of choice for correction of secundum type atrial septal defect is cardiopulmonary bypass. Combination of atrial septal defect with partial anomalous pulmonary venous drainage is considered absolute indication for bypass operation. The authors apply an original method for closure of the defect without resorting to bypass. For a period of seven years they have operated 240 patients from 3 to 54 years of age. Eighty four patients have been operated by the covered method of professor Zorin and in 23 correction of venous sinus defect was performed.


Asunto(s)
Defectos del Tabique Interatrial/cirugía , Adolescente , Adulto , Niño , Preescolar , Tabiques Cardíacos/cirugía , Humanos , Métodos , Persona de Mediana Edad , Técnicas de Sutura
12.
Grud Serdechnososudistaia Khir ; (11): 45-8, 1990 Oct.
Artículo en Ruso | MEDLINE | ID: mdl-2285557

RESUMEN

A defective aortic valve removed from a cadaver was installed on a testing unit imitating systemic circulation. The defect (insufficiency of the valve) was corrected by means of valvular devices consisting of a thin elastic membrane which was flat and round in one case and shaped like a spherical vault in the other; the devices were fastened on the distal end of a catheter. The authors present the values of pressure in the heart, aorta and coronary arteries and the minute circulation volume before and after correction of the defect. It is concluded that the suggested valvular devices are efficient and further study is expedient.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica , Humanos
14.
Vestn Khir Im I I Grek ; 143(9): 104-7, 1989 Sep.
Artículo en Ruso | MEDLINE | ID: mdl-2617761

RESUMEN

A comparative analysis of effectiveness of anti-ischemic defense of the myocardium performed in operations on the heart in 128 patients has shown that use of ion-balanced solutions is preferential since it allows reducing intrahospital lethality related with acute cardiac insufficiency from 13.3% to 6.3%.


Asunto(s)
Soluciones Cardiopléjicas/administración & dosificación , Electrólitos/administración & dosificación , Paro Cardíaco Inducido , Cardiopatías/cirugía , Adolescente , Adulto , Calcio/administración & dosificación , Humanos , Isquemia/prevención & control , Magnesio/administración & dosificación , Persona de Mediana Edad , Potasio/administración & dosificación , Sodio/administración & dosificación
20.
Vestn Khir Im I I Grek ; 138(3): 3-6, 1987 Mar.
Artículo en Ruso | MEDLINE | ID: mdl-3617368

RESUMEN

Indirect isthmoplasty of the narrow portion of the aorta was performed in 79 patients. Immediate and nearest results have shown the effectiveness of the method in most patients. Remote results were studied in 55 patients, in 47 of them (85%) within the period of from 11 to 23 years after the operation. Unsatisfactory results were found in 28 patients (53%). In 18 patients (34%) the failure was caused by formation of an aneurysm in the site of plasty of the aorta with a synthetic flap. The frequency of the complication was found to depend on the term after surgery. In most cases (14) the aneurysms were formed because of disintegration of the suture material.


Asunto(s)
Coartación Aórtica/cirugía , Prótesis Vascular , Adolescente , Adulto , Aneurisma de la Aorta/etiología , Prótesis Vascular/efectos adversos , Niño , Preescolar , Humanos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...