Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Ultrasound Med ; 41(1): 107-121, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33724514

RESUMEN

PURPOSE: To investigate whether phase-shift perfluoropetane (PFP) nanoemulsions can enhance pulsed high-intensity focused ultrasound (HIFU) ablation. METHODS: PFP was encapsulated by poly(lactic-co-glycolic acid) (PLGA) to form a nanometer-sized droplet (PLGA-PFP), which was added to an isolated perfused liver system. Meanwhile, phosphate-buffered saline (PBS) was used as a control. The perfused liver was exposed to HIFU (150 W, t = 3/5/10 s) at various duty cycles (DCs). The ultrasound images, cavitation emissions, and temperature were recorded. Rabbits with subcutaneous VX2 tumors were exposed to HIFU (150 W) at various DCs with or without PLGA-PFP. After ablation, necrosis volume and energy efficiency factor were calculated. Pathologic characteristics were observed. RESULTS: Compared to the PBS control, PLGA-PFP nanoemulsions markedly enhanced HIFU-induced necrosis volume in both perfused livers and subcutaneous VX2 tumor-bearing rabbits (P <.05). Inertial cavitation was much stronger in the pulsed-HIFU exposure at 10% than that in the continuous-wave HIFU exposure (P <.01). Peak temperature at 100% DC was significantly higher than that at 10% (P <.05). Compared to 100% DC HIFU exposure, the mean necrosis volume induced by 10 s exposure at 50% DC was significantly larger (P <.005) but lower at 10% DC in the isolated perfused livers (P <.05). In addition, the mean necrosis volume in subcutaneous VX2 tumor-bearing rabbits was significantly increased after HIFU exposure at 10% DC when compared to those at 100% DC (P <.05). Histopathologic analysis showed liquefaction necrosis in pulsed HIFU. CONCLUSION: PLGA-PFP nanoemulsions can enhance HIFU ablation in the isolated perfused livers and promote tumor ablation in the subcutaneous xenograft rabbit model. Appropriate pulsed HIFU exposure may increase the necrosis volume and reduce total ultrasound energy required for HIFU ablation.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Neoplasias , Animales , Fluorocarburos , Hígado/diagnóstico por imagen , Hígado/cirugía , Conejos
2.
Ultrasound Med Biol ; 43(3): 629-639, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28062179

RESUMEN

Uncontrolled hemorrhage after trauma to the liver can lead to death. The present study compared the effects of non-focused microbubble-enhanced ultrasound and high-intensity focused ultrasound on hepatic hemostasis in the injured liver. Blood perfusion level, serum liver enzyme levels and the aspartate transaminase/alanine transaminase ratio differed between the two types of treatment (all p values < 0.05). Hepatic cells in the microbubble-enhanced ultrasound group exhibited edema and compressed the hepatic sinus and blood vessels in the portal area. Coagulation and necrosis, inflammatory cell infiltration, and fibrous tissue encapsulation were observed in the high-intensity focused ultrasound group at later stages. The groups also differed in degree of ultrastructural damage and recovery time. Thus, microbubble-enhanced ultrasound has less of an impact on blood reperfusion and surrounding normal tissue than high-intensity focused ultrasound and is a better choice for the treatment of liver trauma.


Asunto(s)
Medios de Contraste , Hemostasis/fisiología , Aumento de la Imagen/métodos , Hígado/diagnóstico por imagen , Hígado/lesiones , Terapia por Ultrasonido/métodos , Animales , Modelos Animales de Enfermedad , Hígado/fisiopatología , Microburbujas , Conejos
3.
Int J Hyperthermia ; 33(3): 343-353, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27881031

RESUMEN

PURPOSE: To investigate whether cavitation enhances the degree of coagulation during pulsed high-intensity focussed ultrasound (HIFU) in an isolated liver perfusion system. METHODS: Isolated liver was treated by pulsed HIFU or continuous-wave HIFU with different portal vein flow rates. The cavitation emission during exposure was recorded, and real-time ultrasound images were used to observe changes in the grey scale. The coagulation size was measured and calculated. RESULTS: HIFU treatment led to complete coagulation necrosis and total cell destruction in the target regions. Compared to exposure at a duty cycle (DC) of 100%, the mean volumes of lesions induced by 6 s exposure at DCs of 50% and 10% were significantly larger (P < .01) but were smaller at a DC of 5%. The necrosis volume was negatively related to the perfusion rate in the pulsed HIFU at a DC of 50% for exposure durations of 4 and 6 s, while the perfusion flow rate did not affect the necrosis volume for exposure durations of 1, 2 and 3 s. For increased perfusion flow rates, there was no significant decrease in the cavitation activity for the pulsed-HIFU (P > .05). For continuous-wave HIFU exposure, there was a significant decrease in the necrosis volume and cavitation activity for exposure times of 1, 2, 3, 4, and 6 s with increasing portal perfusion rates. CONCLUSION: Perfusion flow rates negatively influence cavitation activity and coagulation volume. Ablation is significantly enhanced during pulsed HIFU exposure compared with continuous-wave HIFU.

4.
Nan Fang Yi Ke Da Xue Xue Bao ; 36(10): 1352-1356, 2016 Oct 20.
Artículo en Chino | MEDLINE | ID: mdl-27777197

RESUMEN

OBJECTIVE: To compare the effect of low-dose focused ultrasound pre-irradiation and microbubbles for enhancing the ablation effect of high intensity focused ultrasound (HIFU) on VX2 hepatic tumor in rabbits. METHODS: Fifty-five rabbits bearing VX2 hepatic tumor were randomly divided into low-dose pre-irradiation + HIFU ablation group, microbubbles+HIFU ablation group, and HIFU ablation group for corresponding treatments. The pathological changes in the tumors after low-dose irradiation, time for HIFU ablation, tumor volume with coagulative necrosis, energy efficiency factor (EEF), pathological changes in the ablated tumor, and sound channel of HIFU ablation were observed. RESULTS: Tumor cell edema, vacuolar changes in the cytoplasm and tumor interstitial vascular congestion were observed 24 h after low-dose pre-irradiation. The ablation time were significantly shorter, coagulative necrosis volume was larger, and EEF was lower in low-dose irradiation + HIFU ablation group and microbubbles+HIFU ablation group than in simple HIFU ablation group (P<0.05), but the differences between the former two groups were not significant. The effectiveness and stability of the synergistic effect of low-dose pre-irradiation were inferior to microbubbles, but the former ensured a better safety of the sound channel. CONCLUSION: Low-dose irradiation has comparable synergistic effect in HIFU with microbubbles with such advantages as non-invasiveness, high concentration and good safety, and can be a potentially new method to enhance the efficiency of HIFU.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Neoplasias Hepáticas/terapia , Microburbujas , Animales , Necrosis , Conejos , Carga Tumoral
5.
Biomed Res Int ; 2016: 7936902, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27419138

RESUMEN

Purpose. To investigate whether acoustic cavitation could increase the evaporation of a phase-shift inorganic perfluorohexane (PFH) nanoemulsion and enhance high intensity focused ultrasound (HIFU) ablation. Materials and Methods. PFH was encapsulated by mesoporous silica nanocapsule (MSNC) to form a nanometer-sized droplet (MSNC-PFH). It was added to a tissue-mimicking phantom, whereas phosphate buffered saline (PBS) was added as a control (PBS-control). HIFU (P ac = 150 W, t = 5/10 s) exposures were performed in both phantoms with various duty cycles (DC). US images, temperature, and cavitation emissions were recorded during HIFU exposure. HIFU-induced lesions were measured and calculated. Results. Compared to PBS-control, MSNC-PFH nanoemulsion could significantly increase the volume of HIFU-induced lesion (P < 0.01). Peak temperatures were 78.16 ± 5.64°C at a DC of 100%, 70.17 ± 6.43°C at 10%, 53.17 ± 4.54°C at 5%, and 42.00 ± 5.55°C at 2%, respectively. Inertial cavitation was much stronger in the pulsed-HIFU than that in the continuous-wave HIFU exposure. Compared to 100%-DC exposure, the mean volume of lesion induced by 5 s exposure at 10%-DC was significantly larger, but smaller at 2%-DC. Conclusions. MSNC-PFH nanoemulsion can significantly enhance HIFU ablation. Appropriate pulsed-HIFU exposure could significantly increase the volume of lesion and reduce total US energy required for HIFU ablation.


Asunto(s)
Fluorocarburos/química , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Nanocápsulas/química , Nanocápsulas/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Fluorocarburos/efectos de la radiación , Fluorocarburos/uso terapéutico , Gases/síntesis química , Gases/efectos de la radiación , Ondas de Choque de Alta Energía , Técnicas In Vitro , Compuestos Inorgánicos/química , Compuestos Inorgánicos/efectos de la radiación , Compuestos Inorgánicos/uso terapéutico , Ensayo de Materiales , Nanocápsulas/ultraestructura , Tamaño de la Partícula , Resultado del Tratamiento
6.
Ultrasound Med Biol ; 39(8): 1410-9, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23711500

RESUMEN

The aims of this study were to investigate the feasibility of accelerated tissue ablation using a peripheral scanning mode with high-intensity focused ultrasound (HIFU) and to explore the effect of flow rate on total energy consumption of the target tissues. Using a model of isolated porcine liver perfusion via the portal vein and hepatic artery, we conducted a scanning protocol along the periphery of the target tissues using linear-scanned HIFU to carefully adjust the varying focal depth, generator power, scanning velocity and line-by-line interval over the entire ablation range. Porcine livers were divided into four ablation groups: group 1, n = 12, with dual-vessel perfusion; group 2, n = 11, with portal vein perfusion alone; group 3, n = 10, with hepatic artery perfusion alone; and group 4, n = 11, control group with no-flow perfusion. The samples were cut open consecutively at a thickness of 3 mm, and the actual ablation ranges were calculated along the periphery of the target tissues after triphenyl tetrazolium chloride staining. Total energy consumption was calculated as the sum of the energy requirements at various focal depths in each group. On the basis of the pre-supposed scanning protocol, the peripheral region of the target tissue formed a complete coagulation necrosis barrier in each group with varying dose combinations, and the volume of the peripheral necrotic area did not differ significantly among the four groups (p > 0.05). Furthermore, total energy consumption in each group significantly decreased with the corresponding decrease in flow rate (p < 0.01). This study revealed that the complete peripheral necrosis barrier within the target tissues can defined using linear-scanned HIFU in an isolated porcine liver perfusion model. Additionally, the flow rate in the major hepatic vessels may play an important role in the use of the peripheral ablation mode, and this novel mode of ablation may enhance the therapeutic efficacy and tolerability of the treatment of large tumors using HIFU ablation.


Asunto(s)
Hepatectomía/métodos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Hígado/diagnóstico por imagen , Hígado/cirugía , Animales , Estudios de Factibilidad , Técnicas In Vitro , Perfusión , Porcinos , Ultrasonografía
7.
Ultrasound Med Biol ; 38(12): 2138-42, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23062369

RESUMEN

We explored the effectiveness, safety, and feasibility of focused ultrasound in terminating undesired pregnancy. A high-intensity focused ultrasound therapeutic unit was employed to terminate early pregnancies in rhesus macaques. B-mode ultrasound incorporated within the system was used to locate and study the gestational sacs of 6 rhesus macaques with gestation ages of 37 to 66 days, and varying modes of ultrasound exposure were adopted in the termination of the early pregnancies of the rhesus macaques. After focused ultrasound exposure, B-mode ultrasound of the gestational sacs showed significant lethal changes. Of the 6 rhesus macaques, 5 underwent complete abortions whereas 1 rhesus macaque underwent an incomplete abortion. The rhesus macaques resumed their menstrual cycles 50 days after focused-ultrasound treatment. The results suggested that focused ultrasound could be safe, feasible, and effective in terminating early pregnancies in rhesus macaques. As a novel physical method, it may be a promising ablation for a potentially clinical application.


Asunto(s)
Aborto Inducido/métodos , Terapia por Ultrasonido , Animales , Femenino , Edad Gestacional , Macaca mulatta , Proyectos Piloto , Embarazo
8.
Zhonghua Fu Chan Ke Za Zhi ; 46(6): 403-6, 2011 Jun.
Artículo en Chino | MEDLINE | ID: mdl-21781577

RESUMEN

OBJECTIVE: To explore the relationship between therapeutic dosage of ultrasound ablation in treatment of uterine fibroids and imaging characteristics of bloody supply of uterine fibroids by color Doppler ultrasound imaging. METHODS: One hundred and forty-two patients with 168 fibroids were treated by ultrasound ablation. Before treatment, bloody supply of fibroids were classified into grade 0 - 4 by ultrasonography. Three patients lost follow-up with contrast MRI exam within 1 month after treatment, so 165 fibroids were enrolled in this study. Bloody supplies were 9 fibroids in grade 0, 34 fibroids in grade 1, 35 fibroids in grade 2, 55 fibroids in grade 3 and 32 fibroids in grade 4. After 1 month treatment, the treated area without blood supply and ratio of ablation were measured by contrast MRI to evaluate the efficacy of thermal ablation and compare status of blood supple based different therapeutic dosage. According to International Reditherapy for Society (SIR) standard, adverse effect and score of pain were evaluated. RESULTS: (1) Ratio of ablation based: ratios of ablation were 79% in grade 0, 89% in grade 1, 92% in grade 2, 86% in grade 3, 71% in grade 4. It reached statistical difference when blood supply of grade 0 compared with those of grade 2 and 3 (P < 0.05) and blood supply of grade 4 compared with those of grade 1, 2, 3 (P < 0.05). (2) Factor of energy efficiency: factor of energy efficiency were 13.19 J/mm(3) in degree 0, 9.54 J/mm(3) in degree 1, 12.91 J/mm(3) in degree 2, 17.83 J/mm(3) in degree 3 and 28.10 J/mm(3) in degree 4. Factor of energy of ablation in degree 4 was significantly higher than those in degree 1, 2 and 3 blood supply (P < 0.05). It exhibit the positive relationship between blood supply and factor of energy of ablation (r = 0.354, P < 0.01). (3) Score of pain and adverse effect: nearly 85% (120/142) patients could tolerate this treatment very well. Those scores of pain were in range of 0 to 4. All patients did not extend their hospitalization and C to F of SIR standard was not recorded. CONCLUSION: blood supply of myoma measured by ultrasound could predict dosage of ultrasound ablation, it could help select indicated well patients.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Leiomioma/irrigación sanguínea , Leiomioma/terapia , Neoplasias Uterinas/irrigación sanguínea , Neoplasias Uterinas/terapia , Adulto , Femenino , Humanos , Leiomioma/diagnóstico por imagen , Imagen por Resonancia Magnética , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Dimensión del Dolor , Resultado del Tratamiento , Ultrasonografía Doppler en Color/métodos , Neoplasias Uterinas/diagnóstico por imagen , Neoplasias Uterinas/patología , Útero/irrigación sanguínea , Útero/diagnóstico por imagen , Útero/patología , Adulto Joven
9.
Radiology ; 236(3): 1034-40, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16055692

RESUMEN

The study was approved by the university ethics committee, and informed consent was obtained from all patients. The purpose of this study was to prospectively evaluate ultrasonographically guided high-intensity focused ultrasound in the treatment of patients with advanced-stage pancreatic cancer. Eight patients underwent high-intensity focused ultrasound ablation, and laboratory and radiologic examinations were performed after intervention. Changes in symptoms and survival time were noted at follow-up. No complications were observed, and preexisting severe back pain disappeared after intervention. Follow-up images revealed an absence of tumor blood supply and shrinkage of the ablated tumor. Four patients died, and four patients were alive at the time of this writing, with a median survival time of 11.25 months. The authors conclude that high-intensity focused ultrasound ablation is safe and feasible in the treatment of advanced pancreatic cancer.


Asunto(s)
Neoplasias Pancreáticas/terapia , Terapia por Ultrasonido/métodos , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Estudios Prospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional
10.
Breast Cancer Res Treat ; 92(1): 51-60, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15980991

RESUMEN

PURPOSE: To investigate the safety, efficacy and feasibility of using high-intensity focused ultrasound (HIFU) as a non-invasive treatment for patients with breast cancer. PATIENTS AND METHODS: Twenty-two patients with breast cancer were enrolled into this non-randomized prospective trial. Disease TNM stage was classified as stage I in 4 patients, stage II(A) in 9 patients, stage II(B) in 8 patients, and stage IV in 1 patient. Tumor size ranged from 2 to 4.8 cm in diameter (mean 3.4 cm). All patients received chemotherapy, radiation and tamoxifen, following HIFU for the primary lesions. Outcome measures included radiological and pathologic assessment of the treated tumor, cosmesis, and local recurrence. A cumulative survival rate is calculated by using the Kaplan-Meier method. RESULTS: No severe complications were encountered after HIFU. Post-operative imaging demonstrated positive response and regression of all treated lesions. Follow-up biopsy revealed coagulation necrosis of target tumor and subsequent replacement by fibroblastic tissue. After a median follow-up of 54.8 months, 1 patient died, 1 was lost to follow-up, and 20 were still alive. Two of 22 patients developed local recurrence. Five-year disease-free survival and recurrence-free survival were 95% and 89%, respectively. Cosmetic result was judged as good to excellent in 94% of patients. CONCLUSIONS: HIFU treatment is safe, effective, and feasible for patients with breast cancer. But, large-scale, multiple-center clinical trials will be needed to determine the future role of this novel modality.


Asunto(s)
Neoplasias de la Mama/terapia , Recurrencia Local de Neoplasia , Terapia por Ultrasonido/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Terapia Combinada , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Satisfacción del Paciente , Estudios Prospectivos , Inducción de Remisión , Análisis de Supervivencia , Resultado del Tratamiento , Ultrasonografía
11.
Radiology ; 235(2): 659-67, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15858105

RESUMEN

PURPOSE: To evaluate ultrasonographically (US)-guided high-intensity focused ultrasound ablation combined with transcatheter arterial chemoembolization (TACE) in the treatment of stage IVA hepatocellular carcinoma (HCC). MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. From November 1998 to May 2000, 50 consecutive patients with stage IVA HCC (TNM classification, T4N0-1M0) were alternately enrolled in one of two treatment groups: group 1 (n = 26), in which TACE was performed alone, and group 2 (n = 24), in which transcutaneous ablation of HCC with high-intensity focused ultrasound was performed 2-4 weeks after TACE. The tumors were 4-14 cm in diameter (mean, 10.5 cm). Immediate therapeutic effects were assessed at follow-up with Doppler US and computed tomography or magnetic resonance imaging. All patients were followed up for 3-24 months (mean, 8 months) to observe long-term therapeutic effects and complications in both groups. Tumor reduction rates, median survival time, and cumulative survival rates in both groups were calculated by using the unpaired Student t test and Kaplan-Meier method. RESULTS: No severe complication was observed after focused ultrasound ablation, and no unexpected side effects were noted after TACE. Follow-up images showed absence or reduction of blood supply in the lesions after focused ultrasound ablation when compared with blood supply after TACE alone. The median survival time was 11.3 months in group 2 and 4.0 months in group 1 (P = .004). The 6-month survival rate was 80.4%-85.4% in group 2 and 13.2% in group 1 (P = .002), and the 1-year survival rate was 42.9% and 0%, respectively. Median reductions in tumor size as a percentage of initial tumor volume at 1, 3, 6, and 12 months after treatment, respectively, were 28.6%, 35.0%, 50.0%, and 50.0% in group 2 and 4.8%, 7.7%, 10.0%, and 0% in group 1 (P < .01). CONCLUSION: The combination of high-intensity focused ultrasound ablation and TACE is a promising approach in patients with advanced-stage HCC, but large-scale randomized clinical trials are necessary for confirmation.


Asunto(s)
Carcinoma Hepatocelular/terapia , Quimioembolización Terapéutica , Neoplasias Hepáticas/terapia , Terapia por Ultrasonido/métodos , Adulto , Anciano , Calibración , Carcinoma Hepatocelular/irrigación sanguínea , Carcinoma Hepatocelular/mortalidad , Carcinoma Hepatocelular/patología , Cisplatino/administración & dosificación , Terapia Combinada , Relación Dosis-Respuesta a Droga , Doxorrubicina/administración & dosificación , Femenino , Estudios de Seguimiento , Humanos , Neoplasias Hepáticas/irrigación sanguínea , Neoplasias Hepáticas/mortalidad , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tasa de Supervivencia , Transductores , Resultado del Tratamiento
12.
Ann Surg Oncol ; 11(12): 1061-9, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15545506

RESUMEN

BACKGROUND: High intensity focused ultrasound (HIFU) is a noninvasive treatment modality that induces complete coagulative necrosis of a deep tumor through the intact skin. The current study was conducted to determine the safety, efficacy, and feasibility of extracorporeal HIFU in the treatment of patients with hepatocellular carcinoma (HCC). METHODS: A total of 55 patients with HCC with cirrhosis were enrolled in this prospective, nonrandomized clinical trial. Among them, 51 patients had unresectable HCC. Tumor size ranged from 4 to 14 cm in diameter with mean diameter of 8.14 cm. According to tumor, node, metastasis (TNM) classification, 15 patients corresponded to stage II, 16 to stage IIIA, and 24 to IIIC. All patients had HIFU, and the median number of HIFU session was 1.69. Safety and efficacy of HIFU were assessed in this trial. RESULTS: No severe side effect was observed in the patients treated with HIFU. Follow-up imaging showed an absence of tumor vascular supply and the shrinkage of treated lesions. Serum alpha-fetoprotein returned to normal level in 34% of patients. The overall survival rates at 6, 12, and 18 months were 86.1%, 61.5%, and 35.3%, respectively. The survival rates were significantly higher in patients in stage II than those in stage IIIA (P = .0132) and in stage IIIC (P = .0265). CONCLUSION: As a noninvasive therapy, HIFU appears to be effective, safe, and feasible in the treatment of patients with HCC. It may play an important role in the ablation of large tumors.


Asunto(s)
Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/terapia , Terapia por Ultrasonido/efectos adversos , Terapia por Ultrasonido/métodos , Adulto , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/patología , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Masculino , Persona de Mediana Edad , Necrosis , Estudios Prospectivos , Análisis de Supervivencia , Resultado del Tratamiento , Ultrasonografía
13.
Ultrasound Med Biol ; 30(4): 511-7, 2004 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15121253

RESUMEN

The theoretical possibility that exposure of a solid malignancy to high-intensity focused ultrasound (US), or HIFU, could lead to an increased rate of metastasis still remains. Using reverse transcriptase polymerase chain reaction (RT-PCR), the potential risk of hematogenous dissemination was assessed in HIFU-treated patients with solid malignancy. RT-PCR can demonstrate the presence or absence of specific RNA fragments. On the day before HIFU ablation, 5-mL peripheral blood samples were collected, and again 5 to 7 days after HIFU, from 26 enrolled patients (hepatocellular carcinoma, HCC: 10; osteosarcoma: 16). Total RNA was isolated and RT-PCR was performed to analyze the mRNA expression of (alpha-fetoprotein (AFP) and bone-specific alkaline phosphatase (BALP) genes. Positive AFP mRNA expression was preoperatively detected in 8 of 10 patients with HCC. In the postoperative specimens, positive expression was also detected in 8 of 10 patients. In 2 patients, circulating tumor cells were found preoperatively, but not postoperatively. Conversely, 2 patients with no circulating tumor cells preoperatively were found to have circulating tumor cells after HIFU. Of 16 osteosarcoma patients, 12 patients had circulating tumor cells and 4 had none. After HIFU treatment, 2 of the 12 patients had converted from presence to absence of circulating cells and the remaining 4 patients remained negative. It is concluded that patients undergoing complete HIFU ablation may demonstrate conversion from presence to absence of circulating tumor-specific marker mRNA, and that HIFU would not enhance the potential risk of metastasis in patients with malignant diseases.


Asunto(s)
Neoplasias/sangre , Células Neoplásicas Circulantes , Terapia por Ultrasonido/efectos adversos , Fosfatasa Alcalina/genética , Neoplasias Óseas/sangre , Neoplasias Óseas/terapia , Carcinoma Hepatocelular/sangre , Carcinoma Hepatocelular/terapia , Línea Celular Tumoral , Humanos , Neoplasias Hepáticas/sangre , Neoplasias Hepáticas/terapia , Neoplasias/terapia , Osteosarcoma/sangre , Osteosarcoma/terapia , ARN Mensajero/análisis , ARN Neoplásico/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , alfa-Fetoproteínas/genética
14.
Ultrasound Med Biol ; 30(2): 245-60, 2004 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-14998677

RESUMEN

The objective of this article is to introduce the early Chinese clinical experience of using extracorporeal focused ultrasound (US) surgery (FUS) for the treatment of solid tumors. From December 1997 to October 2001, a total of 1038 patients with solid tumors underwent FUS ablation in 10 Chinese hospitals. The tumors included primary and metastatic liver cancer, malignant bone tumors, breast cancer, soft tissue sarcomas, kidney cancer, pancreatic cancer, abdominal and pelvic malignant tumors, uterine myoma, benign breast tumors, hepatic hemangioma and other solid tumors. In this article, pathologic changes in tumors treated with FUS, real-time diagnostic imaging for targeting, monitoring and assessment of results by follow-up images are presented. Early clinical results and complications of the technique are also reported.


Asunto(s)
Neoplasias/terapia , Terapia por Ultrasonido/métodos , Anestesia/métodos , Neoplasias Óseas/diagnóstico por imagen , Neoplasias Óseas/cirugía , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Terapia Combinada , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Neoplasias/diagnóstico , Neoplasias/cirugía , Osteosarcoma/diagnóstico por imagen , Osteosarcoma/cirugía , Complicaciones Posoperatorias/etiología , Cuidados Preoperatorios/métodos , Neoplasias de los Tejidos Blandos/diagnóstico por imagen , Neoplasias de los Tejidos Blandos/cirugía , Tomografía Computarizada de Emisión de Fotón Único , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
15.
Ultrasound Med Biol ; 29(10): 1487-92, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14597346

RESUMEN

Proliferation, invasion, immortalization and metastasis are the main malignant characteristics of cancer. Previous studies have shown that high-intensity focused ultrasound (US), or HIFU, can induce irreversible damage both to breast cancer cells and to tumor blood vessels. However, light microscopy alone may not always show this clearly. In this study, molecular biologic techniques were used to examine any changes in molecular markers associated with malignant behavior after exposure to HIFU. A total of 48 women with breast cancer were randomized to a control group (mastectomy) and a HIFU group (HIFU followed by mastectomy). Immunohistochemical staining, messenger RNA (mRNA) in situ hybridization and telomere-repeat amplification protocol-enzyme-linked immunosorbent assay (TRAP-ELISA) techniques were used to detect tumor expression of proliferating cell nuclear antigen (PCNA), cell adhesion molecule CD44v6, matrix metalloproteinase-9 (MMP-9), erbB2 mRNA, and to measure telomerase activity in both groups. The results demonstrated that there were significant alterations in expression of PCNA, CD44v6, MMP-9, erbB2 mRNA, and a dramatic decrease in telomerase activity in the HIFU group. It is concluded that malignant tumor characteristics are arrested by HIFU, and that biologic factors are potential markers for assessing HIFU efficacy.


Asunto(s)
Biomarcadores de Tumor/metabolismo , Neoplasias de la Mama/terapia , Terapia por Ultrasonido , Biomarcadores de Tumor/genética , Neoplasias de la Mama/metabolismo , Terapia Combinada , Femenino , Regulación Neoplásica de la Expresión Génica , Glicoproteínas/metabolismo , Humanos , Receptores de Hialuranos/metabolismo , Mastectomía Radical Modificada , Metaloproteinasa 9 de la Matriz/metabolismo , Proteínas de Neoplasias/metabolismo , Antígeno Nuclear de Célula en Proliferación/metabolismo , ARN Mensajero/genética , ARN Neoplásico/genética , Receptor ErbB-2/biosíntesis , Receptor ErbB-2/genética , Telomerasa/metabolismo
16.
Ultrasound Med Biol ; 28(4): 535-42, 2002 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12049967

RESUMEN

The purpose of this study was to explore the sequential imaging and histologic alterations of tumor blood vessels in the patient with solid malignancies after extracorporeal treatment of high-intensity focused ultrasound (HIFU). A total of 164 patients underwent extracorporeal HIFU ablation of malignant solid tumors. After HIFU treatment, enhanced magnetic resonance imaging (MRI), color Doppler ultrasound (US) imaging, dynamic radionuclide scanning, digital subtraction angiography, and histologic study were performed to monitor the response of tumor vessels to HIFU ablation. Compared with tumor images in the patients before HIFU, clinical images showed an abrupt interruption, followed by the cessation of blood flow within the tumor vessels after HIFU treatment. The histologic examination indicated that not only the treated tumor cells showed coagulative necrosis, but also small tumor vessels were severely damaged by the HIFU treatment. The results strongly imply that the damaged tumor vessels might play a critical role in secondary tumor cell death, and then indirectly strengthen the destructive force of focused US beams on tumor tissue. It is concluded that tumor vessel damage can be induced by HIFU, which may be a promising strategy in the treatment of patients with solid malignancies.


Asunto(s)
Neoplasias/irrigación sanguínea , Neoplasias/terapia , Terapia por Ultrasonido/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...