Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Ann Surg Oncol ; 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39080131

RESUMEN

BACKGROUND: Numerous surgical techniques are currently available for minimally invasive left hepatic resection, each offering its own advantages and disadvantages. PATIENTS AND METHODS: This multimedia manuscript delves into the primary approaches for minimally invasive left hepatectomy, with a focus on particular topics such as left hepatic vein approach, transection and middle hepatic vein exposure, and Glissonean approach. We examine key factors that surgeons should consider when choosing among these methods and provide practical recommendations. RESULTS: To enhance understanding, our article includes video footage from multiple centres, showcasing expertly executed surgeries for each approach along with their main considerations. CONCLUSIONS: This multimedia resource will serve as a valuable guide for surgeons, aiding in the selection of the most suitable strategy for minimally invasive left hepatectomies, tailored to the specific needs of the patient and the characteristics of the lesion.

3.
Updates Surg ; 76(4): 1535-1541, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38507177

RESUMEN

Transduodenal Ampullectomy (TA) is a procedure for resecting low-malignancy ampullary tumors, with postoperative fistula as a notable complication. This study aims to clarify the indications for TA, outline the surgical robotic technique, and emphasize the importance of comprehensive complication management alongside the surgical approach. This multimedia article provides a detailed exposition of the robotic TA surgical technique, including the most important steps involved in exposing and reimplanting biliary and pancreatic ducts. The procedure encompasses the mobilization of the hepatic flexure of the colon, an extensive Kocher maneuver for duodenal mobilization, and ampulla exposure through a duodenal incision. Employing retraction loop sutures enhances surgical field visibility. Reconstruction involves securing pancreatic and biliary ducts to the duodenal mucosa, each tutored with a silicon catheter, and suturing for ampullectomy completion. The total operative time was 380 min. Final histopathology disclosed high-grade dysplasia with an isolated focus of adenocarcinoma (pT1), accompanied by clear resection margins. A postoperative duodenal fistula occurred, managed successfully through conservative treatment, utilizing subcutaneous drainage. Despite accurate robotic TA execution, complications may arise. This study underscores the importance of a comprehensive approach, incorporating meticulous surgical technique and effective complication management, to optimize patient outcomes.


Asunto(s)
Ampolla Hepatopancreática , Enfermedades Duodenales , Fístula Intestinal , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Robotizados , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Fístula Intestinal/cirugía , Fístula Intestinal/etiología , Complicaciones Posoperatorias/prevención & control , Ampolla Hepatopancreática/cirugía , Enfermedades Duodenales/cirugía , Enfermedades Duodenales/etiología , Duodeno/cirugía , Masculino , Adenocarcinoma/cirugía , Neoplasias del Conducto Colédoco/cirugía , Persona de Mediana Edad , Anciano , Femenino , Procedimientos Quirúrgicos del Sistema Digestivo/métodos
4.
Ann Surg Oncol ; 31(5): 3084-3085, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38315334

RESUMEN

BACKGROUND: Perihilar cholangiocarcinoma is a challenging technique to be performed by minimally invasive approach being the type III among the most complex procedure. Nowadays, the robotic approach is gaining increasing interest among the surgical community, and more and more series describing robotic liver resection have been reported. However, few cases of minimally invasive Bismuth type IIIA cholangiocarcinoma have been reported. Robotic approach allows for a better dissection and suture thanks to the flexible and precise instruments movements, overcoming some of the limitations of the laparoscopic technique. Therefore, robotic technique can facilitate some of the critical steps of a technically demanding procedure, such as the extended right hepatectomy for perihilar cholangiocarcinoma Bismuth IIIA type. METHODS: In this multimedia video we describe, for the first time in the literature, a full robotic surgical step-by-step technique with some tips and tricks for treating a perihilar cholangiocarcinoma Bismuth IIIA type, performing a radical extended right hemihepatectomy, including segment I combined with regional lymphadenectomy anf left bile duct reconstruction. A 55-year-old woman with obstructive jaundice (10 mg/dl) was referred to our center. The endobiliary brushing confirmed adenocarcinoma, and MRI/CT showed a focal perihilar lesion of 2 cm, including the main biliary duct bifurcation and extending up to the right duct (Bismuth Type IIIA hilar cholangiocarcinoma). After endoscopic biliary stents placement and 6 weeks after right portal vein embolization, the future liver remnant, including segments II and III, reached an enough hypertrophy volume with a ratio of 30%. A right hemihepatectomy with caudate lobe, including standard standard lymphadenectomy and left biliary duct reconstruction was performed. RESULTS: The operation lasted 670 min with an estimated blood loss of 350 ml. Postoperative pathological examination revealed a moderately differentiated adenocarcinoma pT1N0 with 15 retrieved nodes and free margins. The patient experienced a type A biliary fistula and was discharged on the 21st postoperative day without abdominal drainage. CONCLUSIONS: Through the tips and tricks presented in this multimedia article, we show the advantages of the robotic approach for performing correctly one of the most complex surgeries.1-7.


Asunto(s)
Neoplasias de los Conductos Biliares , Colangiocarcinoma , Tumor de Klatskin , Procedimientos Quirúrgicos Robotizados , Femenino , Humanos , Persona de Mediana Edad , Neoplasias de los Conductos Biliares/cirugía , Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Bismuto , Colangiocarcinoma/cirugía , Hepatectomía/métodos , Tumor de Klatskin/cirugía , Tumor de Klatskin/patología , Procedimientos Quirúrgicos Robotizados/métodos
6.
Ann Surg Oncol ; 31(3): 1916-1918, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38071705

RESUMEN

INTRODUCTION: The robotic approach is attracting increasing interest among the surgical community, and more and more series describing robotic pancreatoduodenectomy have been reported. Thus, surgeons performing robotic pancreatoduodenectomy should be confident with this critical step's potential scenarios. MATERIALS AND METHODS: According to Yosuke et al., there are three different levels of mesopancreas dissection. We describe the main steps for a safe mesopancreas dissection by robotic approach. RESULTS: This multimedia article provides, for the first time in literature, a comprehensive step-by-step overview of the mesopancreas dissection during robotic pancreatoduodenectomy (PD) and its three different levels according to tumor type. CONCLUSIONS: Through the tips and indications presented in this multimedia article, we aim to familiarize surgeons with the mesopancreas dissections levels according to type of malignancy and vascular anatomy.


Asunto(s)
Neoplasias Pancreáticas , Procedimientos Quirúrgicos Robotizados , Cirujanos , Humanos , Neoplasias Pancreáticas/cirugía , Disección , Pancreaticoduodenectomía
7.
BMC Surg ; 18(Suppl 1): 19, 2019 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-31074396

RESUMEN

BACKGROUND: Robotic thyroidectomy by transaxillary approach (RATS) is regarded as a feasible and safe alternative procedure in selected patients with benign disease or thyroid cancer of low risk, facilitating thyroidectomy with respect to conventional endoscopic approach and offering improved cosmetic results. The Da Vinci Xi surgical system (Intuitive Surgical, Sunnyvale, CA, USA) presents technical advantages over its previous generations, including overhead docking, more compact robotic arms, extended range of motion, and ability for camera to be docked in any arm. This construct supports dissection in smaller spaces with less arm interference and improved view. We present an initial experience of RATS on DVSS Xi in an academic Centre in Italy. METHODS: We conducted a prospective observational study, involving patients with thyroid disease and treated between April 2016 and January 2018. A modified thyroidectomy retractor (Modena retractor, CEATEC Medizintechnik, Germany) was used to lift a musculocutaneous flap and operate gasless. Instrument placement was recorded for each procedure. Each procedure description was broken down into three phases, creation of working space, machine docking with instrument positioning and endoscopic operating technique. Duration of cases was recorded. Patients selected were young women, BMI < 30, thyroid nodule < 5 cm, cytology TIR2 to TIR4 (TIR4:only nodules < 1 cm diameter). RESULTS: Twelve RATS were performed within the learning curve for the robotic technique, 10 lobectomies and 2 total thyroidectomies. No patients required reintervention. Mean duration of surgery was 198.9 min for lobectomy and 210 for thyroidectomy. The same surgical team performed all procedures. No patients presented surgery-related complications, mean stay was 3 days. Decrease in operating time was observed after 8 cases along with more precise preparation of working space. Four arms were used in the first 10 procedures then only three. No recurrent laryngeal nerve dysfunction, no seroma or haematoma were recorded. One patient had transient hypocalcaemia after total thyroidectomy. CONCLUSIONS: Since the early phases of a preliminary experience RATS appeared a safe alternative to open thyroidectomy. Uptake of technique was quick on Xi platform with few technical tweaks over techniques described for Si machines. Careful patient selection is crucial. TRIAL REGISTRATION: Retrospectively registered on 20 july 2018 . TRIAL REGISTRATION NUMBER: researchregistry4272. The Research Registry: https://www.researchregistry.com/browse-the-registry#home/registrationdetails/5b517f08dbc2045aefd7f9b4/.


Asunto(s)
Procedimientos Quirúrgicos Robotizados/métodos , Neoplasias de la Tiroides/cirugía , Tiroidectomía/métodos , Adulto , Disección , Endoscopía/métodos , Femenino , Humanos , Curva de Aprendizaje , Persona de Mediana Edad , Tempo Operativo , Estudios Prospectivos , Nódulo Tiroideo/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA