Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Sci Food Agric ; 104(3): 1843-1852, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37870132

RESUMEN

BACKGROUND: The current techniques for determining carbon and nitrogen content to provide information about the nutritional status of plants are time-consuming and expensive. For this reason, the objective of this study was to develop an analytical method for the direct and simultaneous determination of nitrogen and carbon elemental content in soybean leaves using near-infrared spectroscopy and compare the performance of conventional (1100-2500 nm spectral range) and portable equipment (1100-1700 nm spectral range). Partial least-squares regression models were developed using 27 soybean leaf samples collected during the 2021 harvest and applied for the simultaneous determination of carbon and nitrogen in 13 samples collected during the 2022 harvest. RESULTS: The root-mean-square error of prediction values for nitrogen and carbon were low (2.42 g kg-1 and 4.37 g kg-1 respectively) for the benchtop method yielded low but higher for the portable method (3.82 g kg-1 and 10.7 g kg-1 respectively). The benchtop method did not show significant differences when compared with the reference method for determining nitrogen and carbon. In contrast, the portable methodology showed potential as a screening method for determining nitrogen levels, particularly in fieldwork. CONCLUSION: The methodologies evaluated in this study were implemented and evaluated under real crop monitoring conditions, using independent sets of calibration and prediction samples. Their utilization enables the acquisition of cost-effective, safe analytical data aligning with the principles of green analytical chemistry. © 2023 Society of Chemical Industry.


Asunto(s)
Glycine max , Nitrógeno , Nitrógeno/análisis , Carbono/análisis , Hojas de la Planta/química , Análisis de los Mínimos Cuadrados , Calibración
2.
Anal Chem ; 92(22): 14959-14966, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33112616

RESUMEN

In this work, the in-tip thermal infrared enthalpimetry (in-tip TIE) method is proposed for fast enthalpimetric analysis. In this method, the reactions inside the tips of a multichannel pipette were combined with temperature monitoring by an infrared camera. The filter paper was used inside the tips to retain reagents as solutions (wetted paper mode) or as solids (dried paper mode) to perform neutralization, redox, or precipitation reactions. The dried reagents inside the tips were obtained by oven drying a solution retained in the filter paper. The determination of the total acidity of the vinegar, ascorbic acid in vitamin C tablets, and chloride in soy sauces and saline inhalation solutions was performed as examples of the application of the proposed method. The agreement with reference methods ranged from 98 to 107%. The use of reagents dried inside the tip was feasible, leading to a simple aspiration of sample solution within the 12 tips of the pipette to perform a rapid analysis (1 min). Therefore, up to 720 measurements in 1 h were feasible for in-tip TIE over up to 12 measurements for the reference methods. Moreover, miniaturization reduced reagent consumption and residue generation. For example, for in-tip TIE, only 3.6 mL of residues was generated (n = 12) over 60-240 mL in reference methods (n = 3). Contrarily to other TIE methods, no microplates or stirring was required, opening possibilities for field analysis since the multichannel pipette and the infrared camera are both operated with batteries.

3.
Environ Monit Assess ; 187(6): 354, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25971521

RESUMEN

This research aimed at developing the Trophic Water Quality Index (TWQI) for subtropical temperate Brazilian lotic systems based on a review of the indicative values of diatom species obtained using multivariate analysis techniques and considering the environmental gradient defined by a series of measured physical, chemical, and microbiological variables. Sampling was conducted from 2005 to 2009 in the Pardo River Hydrographic Basin, Rio Grande do Sul (RS), Brazil, and in the Andreas Stream Hydrographic Basin, RS, from 2012 to 2013. A total of 140 biological samples and 211 abiotic samples were collected. Data were analyzed by cluster analysis based on the Ward method and canonical correspondence analysis (CCA). The results indicated that total phosphate, turbidity, ammonia nitrogen, electrical conductivity, dissolved oxygen, and thermotolerant coliforms showed a significant correlation with the sample ordination made by CCA, in relation to a gradient of eutrophication. Eutrophication was operationally defined in a broad sense, including the problem of organic pollution and eutrophication of the water. The determination of the different tolerance degrees to eutrophication of the diatom taxa was used to assign trophic values of 1, 2.5, and 4 to species, corresponding to levels of low, medium, and high tolerance, respectively. By using the trophic values obtained for each diatom species, the TWQI constituted a new technological tool for environmental monitoring studies and showed a consistent, robust, and objective database for water quality assessment in subtropical temperate Brazilian lotic systems.


Asunto(s)
Eutrofización , Contaminación del Agua/estadística & datos numéricos , Calidad del Agua/normas , Brasil , Diatomeas/clasificación , Monitoreo del Ambiente/métodos , Análisis Multivariante , Ríos
4.
J Anal Methods Chem ; 2015: 795102, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25861516

RESUMEN

A method for determination of propranolol hydrochloride in pharmaceutical preparation using near infrared spectrometry with fiber optic probe (FTNIR/PROBE) and combined with chemometric methods was developed. Calibration models were developed using two variable selection models: interval partial least squares (iPLS) and synergy interval partial least squares (siPLS). The treatments based on the mean centered data and multiplicative scatter correction (MSC) were selected for models construction. A root mean square error of prediction (RMSEP) of 8.2 mg g(-1) was achieved using siPLS (s2i20PLS) algorithm with spectra divided into 20 intervals and combination of 2 intervals (8501 to 8801 and 5201 to 5501 cm(-1)). Results obtained by the proposed method were compared with those using the pharmacopoeia reference method and significant difference was not observed. Therefore, proposed method allowed a fast, precise, and accurate determination of propranolol hydrochloride in pharmaceutical preparations. Furthermore, it is possible to carry out on-line analysis of this active principle in pharmaceutical formulations with use of fiber optic probe.

5.
Sensors (Basel) ; 13(4): 4258-71, 2013 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-23539030

RESUMEN

The main objective of this study was to use infrared spectroscopy to identify vegetable oils used as raw material for biodiesel production and apply multivariate analysis to the data. Six different vegetable oil sources--canola, cotton, corn, palm, sunflower and soybeans--were used to produce biodiesel batches. The spectra were acquired by Fourier transform infrared spectroscopy using a universal attenuated total reflectance sensor (FTIR-UATR). For the multivariate analysis principal component analysis (PCA), hierarchical cluster analysis (HCA), interval principal component analysis (iPCA) and soft independent modeling of class analogy (SIMCA) were used. The results indicate that is possible to develop a methodology to identify vegetable oils used as raw material in the production of biodiesel by FTIR-UATR applying multivariate analysis. It was also observed that the iPCA found the best spectral range for separation of biodiesel batches using FTIR-UATR data, and with this result, the SIMCA method classified 100% of the soybean biodiesel samples.


Asunto(s)
Biocombustibles/análisis , Aceites de Plantas/análisis , Espectroscopía Infrarroja por Transformada de Fourier/métodos , Análisis por Conglomerados , Análisis Multivariante , Análisis de Componente Principal , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...